Jingyi Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jingyi Wu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Biaohu Liu
Department of Ultrasound, First Affiliated Hospital of Wannan Medical College, Wuhu, People’s Republic of China
2 shared publications- Xia Zhang
Department of Ultrasound Medicine The First Affiliated Hospital of Wannan Medical College Wuhu City Anhui Province China
2 shared publications Bozheng Li
Department of Ultrasound, First Affiliated Hospital of Wannan Medical College, Wuhu, People’s Republic of China
1 shared publicationCaiyun Ding
Department of Physiology, Wannan Medical College, Wuhu, People’s Republic of China
1 shared publication- Caiyun Ding
Department of Physiology, Wannan Medical College, Wuhu, Anhui, China
1 shared publication Chencheng Su
Department of Ultrasound, First Affiliated Hospital of Wannan Medical College, Wuhu, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
- 3 July 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
The value of right ventricular pulmonary artery coupling in determining the prognosis of patients with sepsis
The outcomes of patients with sepsis are influenced by the contractile function of the right ventricle (RV), but the impact of cardiopulmonary interaction in ICU-mortality of sepsis patients remains unclear. This study aims to investigate the ICU-mortality impact of right ventricular-pulmonary artery (RV-PA) coupling in patients with sepsis. We employed echocardiography to assess patients with sepsis within the initial 24 h of their admission to the ICU. RV-PA coupling was evaluated using the tricuspid annular plane systolic excursion (TAPSE) to pulmonary artery systolic pressure (PASP) ratio. A total of 92 subjects were enrolled, with 55 survivors and 37 non-survivors. TAPSE/PASP ratio assessed mortality with an area under the curve (AUC) of 0.766 (95% CI 0.670–0.862) and the optimal cutoff value was 0.495 mm/mmHg. We constructed a nomogram depicting the TAPSE/PASP in conjunction with IL-6 and Lac for the joint prediction of sepsis prognosis, and demonstrated the highest predictive capability (AUC = 0.878, 95% CI 0.809–0.948). In conclusion, the TAPSE/PASP ratio demonstrated prognostic value for ICU mortality in sepsis patients. The nomogram, which combines the TAPSE/PASP, IL-6, and LAC, demonstrated enhanced predictive efficacy for the prognosis of sepsis patients.
- 3 July 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Open AccessThe value of right ventricular pulmonary artery coupling in determining the prognosis of patients with sepsis
The outcomes of patients with sepsis are influenced by the contractile function of the right ventricle (RV), but the impact of cardiopulmonary interaction in ICU-mortality of sepsis patients remains unclear. This study aims to investigate the ICU-mortality impact of right ventricular-pulmonary artery (RV-PA) coupling in patients with sepsis. We employed echocardiography to assess patients with sepsis within the initial 24 h of their admission to the ICU. RV-PA coupling was evaluated using the tricuspid annular plane systolic excursion (TAPSE) to pulmonary artery systolic pressure (PASP) ratio. A total of 92 subjects were enrolled, with 55 survivors and 37 non-survivors. TAPSE/PASP ratio assessed mortality with an area under the curve (AUC) of 0.766 (95% CI 0.670–0.862) and the optimal cutoff value was 0.495 mm/mmHg. We constructed a nomogram depicting the TAPSE/PASP in conjunction with IL-6 and Lac for the joint prediction of sepsis prognosis, and demonstrated the highest predictive capability (AUC = 0.878, 95% CI 0.809–0.948). In conclusion, the TAPSE/PASP ratio demonstrated prognostic value for ICU mortality in sepsis patients. The nomogram, which combines the TAPSE/PASP, IL-6, and LAC, demonstrated enhanced predictive efficacy for the prognosis of sepsis patients.
- Open Access
- 16 May 2023
- Published by Wolters Kluwer Health in Shock
- Vol. 60 (1) , 11-17
RESPIRATORY VARIABILITY OF VALVULAR PEAK SYSTOLIC VELOCITY AS A NEW INDICATOR OF FLUID RESPONSIVENESS IN PATIENTS WITH SEPTIC SHOCK
Objective: The aim of this study was to evaluate the reliability and feasibility of pulse Doppler measurements of peak velocity respiratory variability of mitral and tricuspid valve rings during systole as new dynamic indicators of fluid responsiveness in patients with septic shock. Methods: Transthoracic echocardiography (TTE) was performed to measure the respiratory variability of aortic velocity-time integral (∆VTI), respiratory variability of tricuspid annulus systolic peak velocity (∆RVS), respiratory variability of mitral annulus systolic peak velocity (∆LVS), and other related indicators. Fluid responsiveness was defined as a 10% increase in cardiac output after fluid expansion, assessed by TTE. Results: A total of 33 patients with septic shock were enrolled in this study. First, there was no significant difference in the population characteristics between the fluid responsiveness positive group (n = 17) and the fluid responsiveness negative group (n = 16) (P > 0.05). Second, Pearson correlation test showed that ∆RVS, ∆LVS, and TAPSE with the relative increase in cardiac output after fluid expansion (R = 0.55, P = 0.001; R = 0.40, P = 0.02; R = 0.36, P = 0.041). Third, multiple logistic regression analysis demonstrated that ∆RVS, ∆LVS, and TAPSE were significantly correlated with fluid responsiveness in patients with septic shock. Fourth, receiver operating characteristic (ROC) curve analysis revealed that ∆VTI, ∆LVS, ∆RVS, and TAPSE had good predictive ability for fluid responsiveness in patients with septic shock. The area under the curve (AUC) of ∆VTI, ∆LVS, ∆RVS, and TAPSE for predicting fluid responsiveness was 0.952, 0.802, 0.822, and 0.713, respectively. The sensitivity (Se) values were 1.00, 0.73, 0.81, and 0.83, whereas the specificity (Sp) values were 0.84, 0.91, 0.76, and 0.67, respectively. The optimal thresholds were 0.128, 0.129, 0.130, and 13.9 mm, respectively. Conclusion: Tissue Doppler ultrasound evaluation of respiratory variability of mitral and tricuspid annular peak systolic velocity could be a feasible and reliable method for the simple assessment of fluid responsiveness in patients with septic shock.
- 16 May 2023
- Published by Wolters Kluwer Health in Shock
- Vol. 60 (1) , 11-17
Open AccessRESPIRATORY VARIABILITY OF VALVULAR PEAK SYSTOLIC VELOCITY AS A NEW INDICATOR OF FLUID RESPONSIVENESS IN PATIENTS WITH SEPTIC SHOCK
Objective: The aim of this study was to evaluate the reliability and feasibility of pulse Doppler measurements of peak velocity respiratory variability of mitral and tricuspid valve rings during systole as new dynamic indicators of fluid responsiveness in patients with septic shock. Methods: Transthoracic echocardiography (TTE) was performed to measure the respiratory variability of aortic velocity-time integral (∆VTI), respiratory variability of tricuspid annulus systolic peak velocity (∆RVS), respiratory variability of mitral annulus systolic peak velocity (∆LVS), and other related indicators. Fluid responsiveness was defined as a 10% increase in cardiac output after fluid expansion, assessed by TTE. Results: A total of 33 patients with septic shock were enrolled in this study. First, there was no significant difference in the population characteristics between the fluid responsiveness positive group (n = 17) and the fluid responsiveness negative group (n = 16) (P > 0.05). Second, Pearson correlation test showed that ∆RVS, ∆LVS, and TAPSE with the relative increase in cardiac output after fluid expansion (R = 0.55, P = 0.001; R = 0.40, P = 0.02; R = 0.36, P = 0.041). Third, multiple logistic regression analysis demonstrated that ∆RVS, ∆LVS, and TAPSE were significantly correlated with fluid responsiveness in patients with septic shock. Fourth, receiver operating characteristic (ROC) curve analysis revealed that ∆VTI, ∆LVS, ∆RVS, and TAPSE had good predictive ability for fluid responsiveness in patients with septic shock. The area under the curve (AUC) of ∆VTI, ∆LVS, ∆RVS, and TAPSE for predicting fluid responsiveness was 0.952, 0.802, 0.822, and 0.713, respectively. The sensitivity (Se) values were 1.00, 0.73, 0.81, and 0.83, whereas the specificity (Sp) values were 0.84, 0.91, 0.76, and 0.67, respectively. The optimal thresholds were 0.128, 0.129, 0.130, and 13.9 mm, respectively. Conclusion: Tissue Doppler ultrasound evaluation of respiratory variability of mitral and tricuspid annular peak systolic velocity could be a feasible and reliable method for the simple assessment of fluid responsiveness in patients with septic shock.
- 6 November 2019
- Published by Springer Nature in Irish Journal of Medical Science (1971 -)
- Vol. 189 (2) , 661-668
Evaluation of diaphragm ultrasound in predicting extubation outcome in mechanically ventilated patients with COPD
To explore the value of the right hemi-diaphragmatic excursion (DE) and its variation in predicting extubation outcome in mechanically ventilated patients with COPD.
- 6 November 2019
- Published by Springer Nature in Irish Journal of Medical Science (1971 -)
- Vol. 189 (2) , 661-668
Evaluation of diaphragm ultrasound in predicting extubation outcome in mechanically ventilated patients with COPD
To explore the value of the right hemi-diaphragmatic excursion (DE) and its variation in predicting extubation outcome in mechanically ventilated patients with COPD.