Dimitrios Brouzas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dimitrios Brouzas has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
Antonios Charakidas
5 shared publicationsMaria Dettoraki
4 shared publicationsMarilita M Moschos
4 shared publicationsMichael Apostolopoulos
National and Kapodistrian University of Athens
4 shared publicationsChryssanthi Koutsandrea
First Department of Ophthalmology, National and Kapodistrian University of Athens, 154 Mesogion Avenue, 11527, Athens, Greece
3 shared publicationsIoannis Ladas
3 shared publications
Latest Publications
- Open Access
- 12 August 2021
- Published by Springer Nature in Cureus
- Vol. 13 (8) , e17138
Correlation Between Central Corneal Thickness and Radial Peripapillary Capillary Density, in Patients With Ocular Hypertension
Purpose To investigate any possible relationship between the central corneal thickness and the radial peripapillary capillary density detected by optical coherence tomography (OCT) angiography in eyes with ocular hypertension. Materials and methods In this observational study, 135 eyes were examined. OCT angiography of the optic disc (4.5 mm) and ultrasound corneal pachymetry were performed in all cases. Age, medical treatment for ocular hypertension, sex, and retinal nerve fiber layer thickness were evaluated. The main indices of blood flow were also examined. Spearman correlation coefficients were used to explore the association between two continuous variables. Results A directly proportional significance regarding the correlation between central corneal thickness and radial peripapillary network was indicated in eyes with ocular hypertension (p =.036). Conclusions Central corneal thickness and radial peripapillary capillary density constitute two essential screening parameters for patients with ocular hypertension.
- 12 August 2021
- Published by Springer Nature in Cureus
- Vol. 13 (8) , e17138
Open AccessCorrelation Between Central Corneal Thickness and Radial Peripapillary Capillary Density, in Patients With Ocular Hypertension
Purpose To investigate any possible relationship between the central corneal thickness and the radial peripapillary capillary density detected by optical coherence tomography (OCT) angiography in eyes with ocular hypertension. Materials and methods In this observational study, 135 eyes were examined. OCT angiography of the optic disc (4.5 mm) and ultrasound corneal pachymetry were performed in all cases. Age, medical treatment for ocular hypertension, sex, and retinal nerve fiber layer thickness were evaluated. The main indices of blood flow were also examined. Spearman correlation coefficients were used to explore the association between two continuous variables. Results A directly proportional significance regarding the correlation between central corneal thickness and radial peripapillary network was indicated in eyes with ocular hypertension (p =.036). Conclusions Central corneal thickness and radial peripapillary capillary density constitute two essential screening parameters for patients with ocular hypertension.
- Open Access
- 1 September 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 2679-2686
Large Retinectomies for Retinal Detachment Complicated by Proliferative Vitreoretinopathy: Anatomical and Functional Outcome of Silicone Oil versus Perfluoropropane Gas
Purpose: To assess the anatomic and functional outcomes of eyes undergoing vitrectomy and large retinectomy for the management of retinal detachment (RD) complicated by advanced proliferative vitreoretinopathy (PVR). Methods: A total of 66 eyes of 63 patients with RD complicated by PVR were treated with vitrectomy and 180° or more retinectomy and silicone oil (n=46) or perfluoropropane gas (n=20) were used as intraocular tamponades. Results: Retinal reattachment was achieved in 89.39% (59 eyes) of the cases. The mean follow-up was 33.7 months (range 12– 76 months). In gas-filled eyes, the final anatomic success rate was 85% (17 eyes) and in silicone oil-filled eyes was 91.3% (42 eyes) (p=0.46). After the initial retinectomy, the total anatomic success rate was 80.3% (53/66 eyes), 70% in gas-filled eyes (14/20 eyes) and 84.79% in silicone oil-filled eyes (39/46 eyes) (p=0.19). Visual acuity (VA) improved in 37 (56.06%) eyes, remained the same in 19 (28.78%) eyes and became worse in 10 (15.15%) cases. Best corrected VA was ≥ 20/200 in 22 eyes 33.33%. The final VA was associated with the preoperative VA (r=0.68), the preoperative status of the macula influence significantly the final visual acuity (p< 0.0001) and there is statistically significant difference in the final visual acuity between eyes with and without anatomic success (p< 0.05). Conclusion: The large circumferential retinectomies can be beneficial in eyes with RD complicated by advanced PVR. No significant difference was found in anatomic success rate, and rate of complications between eyes with silicone oil tamponade and long acting gas undergoing large retinectomy. Regarding the final BCVA, slight difference was found in favor of gas-filled eyes.
- 1 September 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 2679-2686
Open AccessLarge Retinectomies for Retinal Detachment Complicated by Proliferative Vitreoretinopathy: Anatomical and Functional Outcome of Silicone Oil versus Perfluoropropane Gas
Purpose: To assess the anatomic and functional outcomes of eyes undergoing vitrectomy and large retinectomy for the management of retinal detachment (RD) complicated by advanced proliferative vitreoretinopathy (PVR). Methods: A total of 66 eyes of 63 patients with RD complicated by PVR were treated with vitrectomy and 180° or more retinectomy and silicone oil (n=46) or perfluoropropane gas (n=20) were used as intraocular tamponades. Results: Retinal reattachment was achieved in 89.39% (59 eyes) of the cases. The mean follow-up was 33.7 months (range 12– 76 months). In gas-filled eyes, the final anatomic success rate was 85% (17 eyes) and in silicone oil-filled eyes was 91.3% (42 eyes) (p=0.46). After the initial retinectomy, the total anatomic success rate was 80.3% (53/66 eyes), 70% in gas-filled eyes (14/20 eyes) and 84.79% in silicone oil-filled eyes (39/46 eyes) (p=0.19). Visual acuity (VA) improved in 37 (56.06%) eyes, remained the same in 19 (28.78%) eyes and became worse in 10 (15.15%) cases. Best corrected VA was ≥ 20/200 in 22 eyes 33.33%. The final VA was associated with the preoperative VA (r=0.68), the preoperative status of the macula influence significantly the final visual acuity (p< 0.0001) and there is statistically significant difference in the final visual acuity between eyes with and without anatomic success (p< 0.05). Conclusion: The large circumferential retinectomies can be beneficial in eyes with RD complicated by advanced PVR. No significant difference was found in anatomic success rate, and rate of complications between eyes with silicone oil tamponade and long acting gas undergoing large retinectomy. Regarding the final BCVA, slight difference was found in favor of gas-filled eyes.
- Open Access
- 1 December 2018
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 12, 2597-2606
Home-based visual field test for glaucoma screening comparison with Humphrey perimeter
Purpose: To present a home-based visual field examination method using a PC monitor or virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter, in order to assess the possibility of glaucoma screening through the Internet. Materials and methods: Software implementing a supra-threshold algorithm for the central 24° (52 points) of visual field at three threshold levels: 1) -4 db, 2) -8 db, and 3) -12 db, from the age-expected sensitivity was used for the purpose of testing. The software uses the web camera as a “virtual photometer” in order to detect room luminosity and allows self-testing using a computer monitor or virtual reality glasses using an Android smartphone with a 6-inch display. The software includes an expert system to analyze the visual field image and validate the reliability of the results. It also allows the physician to combine the results from two or more tests into a single test in order to achieve higher statistical accuracy of the final result. A total of ten patients, 20 eyes tested×52 points per eye=1,040 visual field test points, were compared point to point to those obtained using the Humphrey perimeter for the same patients, as they appeared randomly and consecutively at the glaucoma department within hours. Results: Good receiver operating characteristic/area under the curve coefficient was found, ranging from 0.762 to 0.837 (PConclusion: The home-based visual field test exhibits a reasonable receiver operating characteristic curve when compared to the Humphrey perimeter, without the need of specialized equipment. The test may be useful for glaucoma screening.
- 1 December 2018
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 12, 2597-2606
Open AccessHome-based visual field test for glaucoma screening comparison with Humphrey perimeter
Purpose: To present a home-based visual field examination method using a PC monitor or virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter, in order to assess the possibility of glaucoma screening through the Internet. Materials and methods: Software implementing a supra-threshold algorithm for the central 24° (52 points) of visual field at three threshold levels: 1) -4 db, 2) -8 db, and 3) -12 db, from the age-expected sensitivity was used for the purpose of testing. The software uses the web camera as a “virtual photometer” in order to detect room luminosity and allows self-testing using a computer monitor or virtual reality glasses using an Android smartphone with a 6-inch display. The software includes an expert system to analyze the visual field image and validate the reliability of the results. It also allows the physician to combine the results from two or more tests into a single test in order to achieve higher statistical accuracy of the final result. A total of ten patients, 20 eyes tested×52 points per eye=1,040 visual field test points, were compared point to point to those obtained using the Humphrey perimeter for the same patients, as they appeared randomly and consecutively at the glaucoma department within hours. Results: Good receiver operating characteristic/area under the curve coefficient was found, ranging from 0.762 to 0.837 (PConclusion: The home-based visual field test exhibits a reasonable receiver operating characteristic curve when compared to the Humphrey perimeter, without the need of specialized equipment. The test may be useful for glaucoma screening.
- 23 October 2017
- Published by Springer Nature in International Ophthalmology
- Vol. 38 (6) , 2349-2356
“Double scleral tunnel in tandem” technique for glaucoma drainage tube implants
To describe a new technique of Ahmed glaucoma valve implantation in patients with refractory glaucoma and present the long-term results.
- 23 October 2017
- Published by Springer Nature in International Ophthalmology
- Vol. 38 (6) , 2349-2356
“Double scleral tunnel in tandem” technique for glaucoma drainage tube implants
To describe a new technique of Ahmed glaucoma valve implantation in patients with refractory glaucoma and present the long-term results.
- Open Access
- 1 August 2017
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 11, 1431-1443
Visual field examination method using virtual reality glasses compared with the Humphrey perimeter
Purpose: To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter. Materials and methods: Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter. Results: High correlation coefficient (r=0.808, PConclusion: Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use.
- 1 August 2017
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 11, 1431-1443
Open AccessVisual field examination method using virtual reality glasses compared with the Humphrey perimeter
Purpose: To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter. Materials and methods: Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter. Results: High correlation coefficient (r=0.808, PConclusion: Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use.
- 16 August 2016
- Published by Springer Nature in International Ophthalmology
- Vol. 37 (3) , 643-648
Postoperative eccentric macular holes after vitrectomy and internal limiting membrane peeling
The purpose of this study was to describe the incidence, clinical characteristics, and outcome of eccentric macular holes presenting after vitrectomy and internal limiting membrane (ILM) peeling for the treatment of macular pathology and discuss the pathogenesis of holes formation. A retrospective, noncomparative, interventional case-series study of five patients who developed eccentric macular holes postoperatively following vitrectomy in 198 consecutive patients who underwent ILM peeling for idiopathic macular hole and epiretinal membrane formation between 2008 and 2015. Five patients (2.5 %) developed full-thickness eccentric macular holes postoperatively. Three patients presented with a single eccentric macular hole, one patient had an eccentric hole after a failed idiopathic macular hole surgery and one patient developed four eccentric macular holes. The mean diameter of the holes was 584 μm (range 206–1317 μm) and the average time of holes formation after vitrectomy was 27.7 weeks (range 1–140 weeks). Postoperative best-corrected visual acuity ranged from “counting fingers” to 20/25. The eyes with the holes distant from the fovea had the best final visual acuity. No further intervention was attempted and no complications occurred. The mean follow-up time was 26.8 months. The postoperative macular holes after vitrectomy and ILM peeling were variable in number, size, and time of appearance but remained stable and were not associated with any complications. The pathogenesis of macular holes is most consistent with contraction of the residual ILM or secondary epimacular proliferation probably stimulated by ILM peeling.
- 16 August 2016
- Published by Springer Nature in International Ophthalmology
- Vol. 37 (3) , 643-648
Postoperative eccentric macular holes after vitrectomy and internal limiting membrane peeling
The purpose of this study was to describe the incidence, clinical characteristics, and outcome of eccentric macular holes presenting after vitrectomy and internal limiting membrane (ILM) peeling for the treatment of macular pathology and discuss the pathogenesis of holes formation. A retrospective, noncomparative, interventional case-series study of five patients who developed eccentric macular holes postoperatively following vitrectomy in 198 consecutive patients who underwent ILM peeling for idiopathic macular hole and epiretinal membrane formation between 2008 and 2015. Five patients (2.5 %) developed full-thickness eccentric macular holes postoperatively. Three patients presented with a single eccentric macular hole, one patient had an eccentric hole after a failed idiopathic macular hole surgery and one patient developed four eccentric macular holes. The mean diameter of the holes was 584 μm (range 206–1317 μm) and the average time of holes formation after vitrectomy was 27.7 weeks (range 1–140 weeks). Postoperative best-corrected visual acuity ranged from “counting fingers” to 20/25. The eyes with the holes distant from the fovea had the best final visual acuity. No further intervention was attempted and no complications occurred. The mean follow-up time was 26.8 months. The postoperative macular holes after vitrectomy and ILM peeling were variable in number, size, and time of appearance but remained stable and were not associated with any complications. The pathogenesis of macular holes is most consistent with contraction of the residual ILM or secondary epimacular proliferation probably stimulated by ILM peeling.
- 1 January 2016
- Published by Elsevier in Prostaglandins & Other Lipid Mediators
- Vol. 122, 69-72
“Association between platelet activating factor acetylhydrolase and diabetic retinopathy: Does inflammation affect the retinal status?”
- 1 January 2016
- Published by Elsevier in Prostaglandins & Other Lipid Mediators
- Vol. 122, 69-72
“Association between platelet activating factor acetylhydrolase and diabetic retinopathy: Does inflammation affect the retinal status?”
- Open Access
- 28 July 2015
- Published by Springer Nature in BMC Anesthesiology
- Vol. 15 (1) , 108
Generalized seizures and transient contralateral hemiparesis following retrobulbar anesthesia: a case report
Retrobulbar block is a local anesthetic technique widely used for intraocular surgery. Although retrobulbar anesthesia is considered to be relatively safe, a number of serious adverse events have been reported. To our knowledge, immediate onset of generalized seizures with contralateral hemiparesis after retrobulbar anesthesia has not been reported. A 62-year-old Caucasian healthy male with a right eye retinal detachment was admitted for pars plana vitrectomy. During retrobulbar anesthesia with ropivacaine and before needle withdrawal, the patient developed twitching of the face which rapidly progressed to generalized tonic-clonic seizures. Arterial oxygen saturation decreased to 75 %. Chin lift was performed and 100 % oxygen was administrated via face mask, which increased saturation to 99 %. Midazolam 2 mg was administrated intravenously to control seizures. After cessation of seizures, left-sided hemiparesis was evident. Brain computed tomography and electroencephalogram were normal 3 h later. The patient underwent pars plana vitrectomy under general anesthesia 4 days later. Serious complications of local anesthesia for ophthalmic surgery are uncommon. We present a case in which generalized tonic-clonic seizures developed during retrobulbar anesthesia, followed by transient contralateral hemiparesis. The early onset of seizures indicated intra-arterial injection of the anesthetic. Our case suggested the need for close monitoring during the performance of retrobulbar anesthesia and the presence of well-trained personnel for early recognition and immediate management of the complications.
- 28 July 2015
- Published by Springer Nature in BMC Anesthesiology
- Vol. 15 (1) , 108
Open AccessGeneralized seizures and transient contralateral hemiparesis following retrobulbar anesthesia: a case report
Retrobulbar block is a local anesthetic technique widely used for intraocular surgery. Although retrobulbar anesthesia is considered to be relatively safe, a number of serious adverse events have been reported. To our knowledge, immediate onset of generalized seizures with contralateral hemiparesis after retrobulbar anesthesia has not been reported. A 62-year-old Caucasian healthy male with a right eye retinal detachment was admitted for pars plana vitrectomy. During retrobulbar anesthesia with ropivacaine and before needle withdrawal, the patient developed twitching of the face which rapidly progressed to generalized tonic-clonic seizures. Arterial oxygen saturation decreased to 75 %. Chin lift was performed and 100 % oxygen was administrated via face mask, which increased saturation to 99 %. Midazolam 2 mg was administrated intravenously to control seizures. After cessation of seizures, left-sided hemiparesis was evident. Brain computed tomography and electroencephalogram were normal 3 h later. The patient underwent pars plana vitrectomy under general anesthesia 4 days later. Serious complications of local anesthesia for ophthalmic surgery are uncommon. We present a case in which generalized tonic-clonic seizures developed during retrobulbar anesthesia, followed by transient contralateral hemiparesis. The early onset of seizures indicated intra-arterial injection of the anesthetic. Our case suggested the need for close monitoring during the performance of retrobulbar anesthesia and the presence of well-trained personnel for early recognition and immediate management of the complications.
- Open Access
- 12 March 2015
- Published by Springer Nature in BMC Ophthalmology
- Vol. 15 (1) , 1-3
Intravitreal cilium associated with retinal detachment 40 years following penetrating eye injury: a case report
The presence of an intraocular cilium is very rare and the response of the eye to the cilium is variable. We present the case of a patient with a cilium found in the vitreous cavity during vitrectomy for rhegmatogenous retinal detachment 40 years following penetrating eye injury. To our knowledge, this is the longest reported presence of a cilium in the vitreous cavity. A 70-year-old Caucasian woman presented to the emergency department of our hospital complaining of sudden visual impairment and floaters of her right eye initiated 2 weeks earlier. Ophthalmic history included a penetrating injury of the right eye with a sharp metallic object 40 years ago and an uncomplicated phacoemulsification surgery in the same eye 2 years earlier. Fundoscopy revealed an inferior macula off rhegmatogenous retinal detachment. No inflammation was present. During vitrectomy and under scleral indentation at 5-o’clock position, a cilium was found at far retinal periphery. One end of the cilium was embedded in the retina, whereas the other end floated freely in the vitreous. The cilium was removed through the pars plana sclerotomy with intraocular foreign body forceps. The procedure was completed without any complications. Penetrating eye injury is the most possible cause of cilium entrance in vitreous cavity in this case, which suggests that cilium can be well tolerated in vitreous cavity for as long as 40 years.
- 12 March 2015
- Published by Springer Nature in BMC Ophthalmology
- Vol. 15 (1) , 1-3
Open AccessIntravitreal cilium associated with retinal detachment 40 years following penetrating eye injury: a case report
The presence of an intraocular cilium is very rare and the response of the eye to the cilium is variable. We present the case of a patient with a cilium found in the vitreous cavity during vitrectomy for rhegmatogenous retinal detachment 40 years following penetrating eye injury. To our knowledge, this is the longest reported presence of a cilium in the vitreous cavity. A 70-year-old Caucasian woman presented to the emergency department of our hospital complaining of sudden visual impairment and floaters of her right eye initiated 2 weeks earlier. Ophthalmic history included a penetrating injury of the right eye with a sharp metallic object 40 years ago and an uncomplicated phacoemulsification surgery in the same eye 2 years earlier. Fundoscopy revealed an inferior macula off rhegmatogenous retinal detachment. No inflammation was present. During vitrectomy and under scleral indentation at 5-o’clock position, a cilium was found at far retinal periphery. One end of the cilium was embedded in the retina, whereas the other end floated freely in the vitreous. The cilium was removed through the pars plana sclerotomy with intraocular foreign body forceps. The procedure was completed without any complications. Penetrating eye injury is the most possible cause of cilium entrance in vitreous cavity in this case, which suggests that cilium can be well tolerated in vitreous cavity for as long as 40 years.
- Open Access
- 1 March 2014
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 8, 523-8
Visual field examination using a video projector: comparison with Humphrey perimeter
Visual field examination using a video projector: comparison with Humphrey perimeter Dimitrios Brouzas, Stylianos Tsapakis, Eirini Nitoda, Marilita M Moschos First Department of Ophthalmology, Medical School, University of Athens, Greece Purpose: To present a method of visual field examination using a video projector. Also, we compare our results with those of a Humphrey perimeter, which is accepted as standard in automated perimetry. Materials and methods: Software implementing a full-threshold 4-2-step staircase algorithm for the central 30-2 of the visual field (76 points) has been developed and tested in nine eyes of seven patients using an Epson TW 700 video projector. The results were compared to those obtained from the same patients using the Humphrey perimeter. Results: High correlation between the video projector visual fields and those of the Humphrey perimeter was found. The point-to-point correlation coefficient ranged from 0.75 to 0.90, with P<0.0001 for each eye. Conclusion: Visual field examination results using a video projector have high correlation with those of a Humphrey perimeter. The method is possibly suitable for clinical use. Keywords: visual fields, video projector, computerized perimetry, automated perimetry, visual field software
- 1 March 2014
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 8, 523-8
Open AccessVisual field examination using a video projector: comparison with Humphrey perimeter
Visual field examination using a video projector: comparison with Humphrey perimeter Dimitrios Brouzas, Stylianos Tsapakis, Eirini Nitoda, Marilita M Moschos First Department of Ophthalmology, Medical School, University of Athens, Greece Purpose: To present a method of visual field examination using a video projector. Also, we compare our results with those of a Humphrey perimeter, which is accepted as standard in automated perimetry. Materials and methods: Software implementing a full-threshold 4-2-step staircase algorithm for the central 30-2 of the visual field (76 points) has been developed and tested in nine eyes of seven patients using an Epson TW 700 video projector. The results were compared to those obtained from the same patients using the Humphrey perimeter. Results: High correlation between the video projector visual fields and those of the Humphrey perimeter was found. The point-to-point correlation coefficient ranged from 0.75 to 0.90, with P<0.0001 for each eye. Conclusion: Visual field examination results using a video projector have high correlation with those of a Humphrey perimeter. The method is possibly suitable for clinical use. Keywords: visual fields, video projector, computerized perimetry, automated perimetry, visual field software