JHJürgen Höher

Jürgen Höher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jürgen Höher has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Press-fit fixation using autologous bone in the tibial canal causes less enlargement of bone tunnel diameter in ACL reconstruction - a CT scan analysis three months postoperatively

    by Ralph Akoto, Jonas Müller-Hübenthal, Maurice Balke, Malte Albers, Bertil Bouillon, Philip Helm, Marc Banerjee, Jürgen Höher

    Bone tunnel enlargement is a phenomenon present in all anterior cruciate ligament (ACL)- reconstruction techniques. It was hypothesized that press-fit fixation using a free autograft bone plug reduces the overall tunnel size in the tibial tunnel. In a prospective cohort study twelve patients who underwent primary ACL reconstruction using an autologous quadriceps tendon graft and adding a free bone block for press-fit fixation (PF) in the tibial tunnel were matched to twelve patients who underwent ACL reconstruction with a hamstring graft and interference screw fixation (IF). The diameters of the bone tunnels were analysed by a multiplanar reconstruction technique (MPR) in a CT scan three months postoperatively. Manual and instrumental laxity (Lachman test, Pivot-shift test, Rolimeter) and functional outcome scores (International Knee Documentation Committee sore, Tegner activity level) were measured after one year follow up. In the PF group the mean bone tunnel diameter at the level of the joint entrance was not significantly enlarged. One and two centimeter distal to the bone tunnel diameter was reduced by 15 % (p = .001). In the IF group the bone tunnel at the level of the joint entrance was enlarged by 14 % (p = .001). One and two centimeter distal to the joint line the IF group showed a widening of the bone tunnel by 21 % (p < .001) One and two centimeter below the joint line the bone tunnel was smaller in the PF group when compared to the IF group (p < .001). No significant difference for laxity test and functional outcome scores could be shown. This study demonstrates that press-fit fixation with free autologous bone plugs in the tibial tunnel results in significantly smaller diameter of the tibial tunnel compared to interference screw fixation.


  • Kniegelenklaxizität beim vorderen Kreuzbandersatz

    by C. Offerhaus, M. Balke, M. Braas, D. Pennig, S. Gick, J. Höher

    Die Verwendung einer Interferenzschraube zur femoralen Fixation beim vorderen Kreuzbandersatz (VKB-Ersatz) mit Hamstring-Sehnen führt oft zu einer Rotation des Transplantats um die Schraube, was dessen endgültige Position im Bohrkanal erheblich beeinflusst.


  • Open Access

    The fabella syndrome - a rare cause of posterolateral knee pain: a review of the literature and two case reports

    by Arne Driessen, Maurice Balke, Christoph Offerhaus, William James White, Sven Shafizadeh, Christoph Becher, Bertil Bouillon, Jürgen Höher

    The purpose of this article was to evaluate the risks and benefits of non-operative treatment versus surgical excision of a fabella causing posterolateral knee pain. We performed a systematic review of literature and also present two case reports. Twelve publications were found in a PubMed literature review searching the word “fabella syndrome”. Non-operative treatment and surgical excision of the fabella has been described. Two patients presented to our outpatient clinic with persisting posterolateral knee pain. In both cases the presence of a fabella was identified, located in close proximity to the posterolateral femoral condyle. All other common causes of intra- and extra articular pathologies possibly causing the posterolateral knee pain were excluded. Following failure to respond to physiotherapy both patients underwent arthroscopy which excluded other possible causes for posterolateral knee pain. The decision was made to undertake surgical excision of the fabella in both cases without complication. Both patients were examined 6 month and one year after surgery with the Tegner activity score, the Visual Analogue Scale (VAS), and International Knee Documentation Committee Score (IKDC). Consistent posterolateral pain during exercise might indicate the presence of a fabella syndrome. Resecting the fabella can be indicated and is a minor surgical procedure with minimal risk. Despite good results in the literature posterolateral knee pain can persist and prevent return to a high level of sports. Level of evidence: IV, case reports and analysis of literature.


  • Rolimeter measurements are suitable as substitutes to stress radiographs in the evaluation of posterior knee laxity

    by Jürgen Höher, Ralph Akoto, Philip Helm, Sven Shafizadeh, Bertil Bouillon, Maurice Balke

    Purpose: The quantification of posterior knee laxity is crucial in the evaluation of injuries to the posterior cruciate ligament (PCL) as it has important implications to the treatment for these injuries. The objective of this study was to compare the test results of stress radiography and instrumented drawer testing (Rolimeter) for the assessment of posterior knee laxity in patients with PCL injury.Methods: In 45 patients with an injury to the PCL, lateral radiographs of both knees were obtained under anterior and posterior tibial load (150 N) using a standardized approach. Patients with injury of the ACL to either knee were excluded from the study. During the same clinic visit, an instrumented measurement of anterior–posterior knee laxity was performed at 90° of knee flexion by an experienced examiner using the Rolimeter device. The mean side‐to‐side differences (SSD) of both (radiographic and instrumented) measurements were compared to each other, and the correlation was calculated using the Pearson coefficient.Results: The SSD (affected/healthy side) of posterior translation determined from the radiographs was 8.2 ± 3.2 mm, and the SSD of the instrumented measurement testing was 7.6 ± 3.2 mm. The mean difference between radiographic and Rolimeter test results was 1.8 ± 1.5 mm. The Pearson's correlation coefficient revealed a good correlation between both measurements of 0.74.Conclusions: It may be suggested by the results of this study that under the absence of an ACL injury and a fixed posterior drawer sign, the Rolimeter is a suitable tool to assess the posterior laxity of the knee in the clinical setting. Its advantages are the absence of radiation to the patient, its availability, and the low cost. Therefore, the Rolimeter device may serve as a valuable alternative to stress radiography in the evaluation of PCL‐injured patients.Level of evidence: II.


  • Kniegelenklaxizität beim vorderen Kreuzbandersatz

    by C. Offerhaus, M. Balke, M. Braas, D. Pennig, S. Gick, J. Höher

    Die Verwendung einer Interferenzschraube zur femoralen Fixation beim vorderen Kreuzbandersatz (VKB-Ersatz) mit Hamstring-Sehnen führt oft zu einer Rotation des Transplantats um die Schraube, was dessen endgültige Position im Bohrkanal erheblich beeinflusst.


  • Impact of tendon suturing on the interference fixation strength of quadrupled hamstring tendon grafts

    by Jürgen Höher, Christoph Offerhaus, Eric Steenlage, Andreas Weiler, Sven Scheffler

    Interference screw fixation of soft tissue grafts has been a widely used fixation technique for cruciate ligament reconstruction. Suturing of the graft construct prior to graft fixation has been proposed to increase fixation strength; however, the effect on mechanical properties has not been well characterized. The goal of this study was to determine whether uniform suturing of the tendon graft affects (1) ultimate fixation strength of the hamstring tendon graft and (2) motion of the tendon in the bone tunnel during cyclic loading when comparing sutured grafts vs. unsutured grafts. Eight pairs of matched mature porcine tibias (age p < 0.05. Elongation at the tendon–bone interface during sub-maximal cyclic loading was 2.4 ± 1.4 mm (unsutured) vs. 2.0 ± 0.7 mm (sutured) (p > 0.05). Failure load of the grafts without sutures (634 ± 86 N) was significantly lower than with the sutures (837 ± 183 N). Ultimate stiffness of group A (283 ± 34 N/mm) was lower than that of group B (331 ± 51 N/mm); however, this was not statistically significant (p = 0.051). This study confirms that suturing of the graft construct before interference screw fixation may increase ultimate failure load. However, an improvement of structural properties in response to cyclic loading with sub-maximal loads could not be confirmed. Clinicians using interference screw fixation may suture the graft to improve fixation strength; however, suturing does not appear to allow a more aggressive rehabilitation after surgery.


  • Tips and Tricks in Arthroscopic Surgery

    by Mohsen Hussein, Jürgen Höher, Rainer Sieboldl, Peter Faunø, Svend Erik Christiansen, Bent Lund, Martin Lind