Arno Buecker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arno Buecker has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Elmar Spuentrup
5 shared publicationsJoop J. van Vaals
From the *Clinic of Diagnostic Radiology and †Department of Laboratory Animal Science, University Hospital, Aachen, Germany; and ‡Philips Medical Systems, Best, The Netherlands
4 shared publicationsRolf W. Günther
4 shared publications- Tobias Schaeffter
Physikalisch‐Technische Bundesanstalt Berlin Germany
4 shared publications Alexander Ruebben
2 shared publicationsArndt Glowinski
Clinic of Diagnostic Radiology, University of Technology Aachen, Aachen, Germany
2 shared publications
Latest Publications
- 1 January 2006
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 15 (2) , 65-70
Safety of MRI‐guided vascular interventions
Longer electrically conducting parts are needed for various instruments such as pacemakers, defibrillators, deep brain stimulators and interventional instruments. Magnetic resonance imaging in the presence of these instruments can be potentially harmful, due to resonance effects and heating of conducting wires. A review of the literature revealed that neither manufacturers of pacemakers and defibrillators nor the FDA consider these medical instruments to be MR-safe, despite the fact that there are some reports about MR scanning of pacemaker patients without critical incidents. MR-guided angiographic interventions require not only high quality real-time imaging, but also MR compatible and MR-safe instruments. Consequently, metallic guidewires as used for angiographic interventions were examined during in vitro experiments in the MR environment. Heating of guidewires to>70 degrees was reported during in vitro experiments. Our own in vivo experiments using commercially available metallic guidewires observed heating to up to 35 degrees at the guidewire tip, despite the cooling effect of blood flowing around the guidewire. Moreover, we saw the development of sparks at the end of the guidewire if it was bent inside of the MR scanner and touched to the animal. But it was not possible to reliably repeat these heating results. We conclude that longer metallic parts have to be avoided inside the MR scanner to guarantee patient safety. In order to exploit more sophisticated technologies such as active tip tracking, solutions without the need for conducting wires have to be further developed before interventional MR can safely move into the clinical setting.
- 1 January 2006
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 15 (2) , 65-70
Safety of MRI‐guided vascular interventions
Longer electrically conducting parts are needed for various instruments such as pacemakers, defibrillators, deep brain stimulators and interventional instruments. Magnetic resonance imaging in the presence of these instruments can be potentially harmful, due to resonance effects and heating of conducting wires. A review of the literature revealed that neither manufacturers of pacemakers and defibrillators nor the FDA consider these medical instruments to be MR-safe, despite the fact that there are some reports about MR scanning of pacemaker patients without critical incidents. MR-guided angiographic interventions require not only high quality real-time imaging, but also MR compatible and MR-safe instruments. Consequently, metallic guidewires as used for angiographic interventions were examined during in vitro experiments in the MR environment. Heating of guidewires to>70 degrees was reported during in vitro experiments. Our own in vivo experiments using commercially available metallic guidewires observed heating to up to 35 degrees at the guidewire tip, despite the cooling effect of blood flowing around the guidewire. Moreover, we saw the development of sparks at the end of the guidewire if it was bent inside of the MR scanner and touched to the animal. But it was not possible to reliably repeat these heating results. We conclude that longer metallic parts have to be avoided inside the MR scanner to guarantee patient safety. In order to exploit more sophisticated technologies such as active tip tracking, solutions without the need for conducting wires have to be further developed before interventional MR can safely move into the clinical setting.
- 1 November 2005
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 40 (11) , 700-704
A Feasibility Study of Contrast Enhancement of Acute Myocardial Infarction in Multislice Computed Tomography
Late enhancement magnetic resonance imaging (MRI) of myocardial infarction (MI) is clinically established. There are no reports on MI assessment using state-of-the-art multislice CT technology. For this reason, animal experiments were conducted to examine the applicability of contrast-enhanced ECG-gated multislice computed tomography (MSCT) for the detection of acute MI. The results were correlated with MRI and postmortem tissue staining. Acute MI was induced in 14 pigs by balloon occlusion of the LAD. In 8 animals, the LAD was reperfused after 45 minutes. In 6 animals, the LAD was permanently blocked. MR imaging was performed 15 minutes after the administration of 0.2 mmol Gd-DTPA/kg/bodyweight. Subsequently, 16-slice MSCT was performed at various timepoints after injecting 120 mL of iodinated contrast medium. 2,3,5-Triphenyltetrazolin-chloride (TTC) staining was acquired for all hearts investigated. Correlation analysis was applied to compare the area of MI derived from MRI, MSCT, and TTC. The reperfused infarcts were compared with the nonreperfused infarcts using an unpaired t test. Mean infarct area as measured by TTC staining was 18.3% ± 7.8% of the left ventricular area. Good correlation of the spatial extent of the infarcted area was found for TTC and MRI as well as for TTC and MSCT data obtained 5 minutes postcontrast injection. MSCT imaging demonstrated a significant difference in density (P < 0.001) between nonreperfused (47.0 ± 6.6 HU) and reperfused (116.4 ± 19.8 HU) infarction. In our pilot study, contrast-enhanced MSCT was feasible to assess myocardial viability in pigs. MSCT also affords differentiation of nonreperfused and reperfused acute MI. MI sizes derived from MSCT imaging correlate well to those obtained with MRI and TTC.
- 1 November 2005
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 40 (11) , 700-704
A Feasibility Study of Contrast Enhancement of Acute Myocardial Infarction in Multislice Computed Tomography
Late enhancement magnetic resonance imaging (MRI) of myocardial infarction (MI) is clinically established. There are no reports on MI assessment using state-of-the-art multislice CT technology. For this reason, animal experiments were conducted to examine the applicability of contrast-enhanced ECG-gated multislice computed tomography (MSCT) for the detection of acute MI. The results were correlated with MRI and postmortem tissue staining. Acute MI was induced in 14 pigs by balloon occlusion of the LAD. In 8 animals, the LAD was reperfused after 45 minutes. In 6 animals, the LAD was permanently blocked. MR imaging was performed 15 minutes after the administration of 0.2 mmol Gd-DTPA/kg/bodyweight. Subsequently, 16-slice MSCT was performed at various timepoints after injecting 120 mL of iodinated contrast medium. 2,3,5-Triphenyltetrazolin-chloride (TTC) staining was acquired for all hearts investigated. Correlation analysis was applied to compare the area of MI derived from MRI, MSCT, and TTC. The reperfused infarcts were compared with the nonreperfused infarcts using an unpaired t test. Mean infarct area as measured by TTC staining was 18.3% ± 7.8% of the left ventricular area. Good correlation of the spatial extent of the infarcted area was found for TTC and MRI as well as for TTC and MSCT data obtained 5 minutes postcontrast injection. MSCT imaging demonstrated a significant difference in density (P < 0.001) between nonreperfused (47.0 ± 6.6 HU) and reperfused (116.4 ± 19.8 HU) infarction. In our pilot study, contrast-enhanced MSCT was feasible to assess myocardial viability in pigs. MSCT also affords differentiation of nonreperfused and reperfused acute MI. MI sizes derived from MSCT imaging correlate well to those obtained with MRI and TTC.
- 1 November 2004
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 39 (11) , 656-660
Use of a Nonmetallic Guide Wire for Magnetic Resonance-Guided Coronary Artery Catheterization
Rationale and Objectives: Metallic guide wires can be subject to substantial heating when used in the magnetic resonance (MR) environment. Therefore, animal experiments were performed to test the feasibility of a non-metallic and MR-safe guide wire with passive markers for catheterization of coronary arteries under MR guidance. Materials and Methods: Self-made guide wires consisting of a resin-microparticle compound covered by polytetrafluoroethylene were used to catheterize both coronary arteries of swine together with a non-braided catheter. Time needed for catheterization was recorded. Results: MR-guided coronary artery catheterization with passive visualization of a self-made non-metallic guide wire is possible. In average 141 seconds (SD 68) were needed to manipulate the guide wire together with a catheter from the carotid artery into the left or right coronary artery ostium. Conclusion: Standard nitinol guide wires have to be considered unsafe for MR-guided interventions due to possible heating of electrical conducting structures in the MR environment. Passive visualization techniques allow MR-guided catheterization of small arteries like coronaries. However, there is the substantial disadvantage of obscuring the underlying anatomy of small vessels by the passive markers needed for real-time MR guidance.
- 1 November 2004
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 39 (11) , 656-660
Use of a Nonmetallic Guide Wire for Magnetic Resonance-Guided Coronary Artery Catheterization
Rationale and Objectives: Metallic guide wires can be subject to substantial heating when used in the magnetic resonance (MR) environment. Therefore, animal experiments were performed to test the feasibility of a non-metallic and MR-safe guide wire with passive markers for catheterization of coronary arteries under MR guidance. Materials and Methods: Self-made guide wires consisting of a resin-microparticle compound covered by polytetrafluoroethylene were used to catheterize both coronary arteries of swine together with a non-braided catheter. Time needed for catheterization was recorded. Results: MR-guided coronary artery catheterization with passive visualization of a self-made non-metallic guide wire is possible. In average 141 seconds (SD 68) were needed to manipulate the guide wire together with a catheter from the carotid artery into the left or right coronary artery ostium. Conclusion: Standard nitinol guide wires have to be considered unsafe for MR-guided interventions due to possible heating of electrical conducting structures in the MR environment. Passive visualization techniques allow MR-guided catheterization of small arteries like coronaries. However, there is the substantial disadvantage of obscuring the underlying anatomy of small vessels by the passive markers needed for real-time MR guidance.
- 1 May 2004
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 39 (5) , 250-253
New Metallic MR Stents for Artifact-Free Coronary MR Angiography
The objective of this study was to investigate the potential for artifact-free coronary magnetic resonance angiography (cMRA) in the presence of dedicated metallic MR stents in vitro and in a swine model. All investigations were performed at 1.5 T, applying a standard cMRA gradient echo sequence with a T2 preparation pulse. Two prototypes of each hand-woven, mechanically woven, and lasered Aachen Resonance Coronary MR Stents made out of an MR-compatible metallic alloy and dilated to 2.5 mm and 4 mm were examined in a water bath. Artifact behavior was judged independently by 2 radiologists as showing "no artifacts" for all tested stent types. Signal-to-noise ratios inside and outside of the stents were measured yielding a Pearson correlation coefficient of 0.98 (y = 1.22 + 0.92x). Nineteen stents (8 hand woven, 3 mechanically woven, 8 lasered) were deployed in coronary arteries of 19 domestic pigs and were examined by cMRA. Artifact behavior of the stents was analyzed by measuring the signal-to-noise ratio at the stent positions and compared with signal-to-noise ratio measurements outside of the stents, yielding a Pearson correlation coefficient of 0.90 (y = -0.75 + 1.06x). All 3 prototypes of coronary MR stents allowed complete visualization of the stent lumen and consequently determination of stent patency by cMRA.
- 1 May 2004
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 39 (5) , 250-253
New Metallic MR Stents for Artifact-Free Coronary MR Angiography
The objective of this study was to investigate the potential for artifact-free coronary magnetic resonance angiography (cMRA) in the presence of dedicated metallic MR stents in vitro and in a swine model. All investigations were performed at 1.5 T, applying a standard cMRA gradient echo sequence with a T2 preparation pulse. Two prototypes of each hand-woven, mechanically woven, and lasered Aachen Resonance Coronary MR Stents made out of an MR-compatible metallic alloy and dilated to 2.5 mm and 4 mm were examined in a water bath. Artifact behavior was judged independently by 2 radiologists as showing "no artifacts" for all tested stent types. Signal-to-noise ratios inside and outside of the stents were measured yielding a Pearson correlation coefficient of 0.98 (y = 1.22 + 0.92x). Nineteen stents (8 hand woven, 3 mechanically woven, 8 lasered) were deployed in coronary arteries of 19 domestic pigs and were examined by cMRA. Artifact behavior of the stents was analyzed by measuring the signal-to-noise ratio at the stent positions and compared with signal-to-noise ratio measurements outside of the stents, yielding a Pearson correlation coefficient of 0.90 (y = -0.75 + 1.06x). All 3 prototypes of coronary MR stents allowed complete visualization of the stent lumen and consequently determination of stent patency by cMRA.
- Open Access
- 23 July 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 106 (4) , 511-515
Magnetic Resonance–Guided Placement of Atrial Septal Closure Device in Animal Model of Patent Foramen Ovale
Background — Percutaneous closure of the patent foramen ovale (PFO) is usually performed under x-ray in combination with ultrasound guidance. We tested the feasibility of applying magnetic resonance (MR) guidance for percutaneous closure of PFO in an animal model, thus avoiding the disadvantage of ionizing radiation. Methods and Results — Real-time MRI with radial or spiral k-space filling (15 frames per second) on an interventional 1.5-T high-field whole-body system was exploited to examine the feasibility of MR-guided closure of the PFO in 7 piglets weighing ≈14 kg. A specially designed prototype nonmagnetic closure device was introduced via the femoral vein. The short bore of the magnet and in-room monitors allowed for visualization and steering of the catheter with the loaded occluder. Catheterization of the left atrium and, finally, correct placement of the device was possible in all animals. Deployment of the device was depicted by real-time MR, and initial misplacement, which occurred in 2 animals, was easily detected and corrected. Conclusions — Real-time MR guidance of PFO closure, without the use of ionizing radiation, is feasible in an animal model.
- 23 July 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 106 (4) , 511-515
Open AccessMagnetic Resonance–Guided Placement of Atrial Septal Closure Device in Animal Model of Patent Foramen Ovale
Background — Percutaneous closure of the patent foramen ovale (PFO) is usually performed under x-ray in combination with ultrasound guidance. We tested the feasibility of applying magnetic resonance (MR) guidance for percutaneous closure of PFO in an animal model, thus avoiding the disadvantage of ionizing radiation. Methods and Results — Real-time MRI with radial or spiral k-space filling (15 frames per second) on an interventional 1.5-T high-field whole-body system was exploited to examine the feasibility of MR-guided closure of the PFO in 7 piglets weighing ≈14 kg. A specially designed prototype nonmagnetic closure device was introduced via the femoral vein. The short bore of the magnet and in-room monitors allowed for visualization and steering of the catheter with the loaded occluder. Catheterization of the left atrium and, finally, correct placement of the device was possible in all animals. Deployment of the device was depicted by real-time MR, and initial misplacement, which occurred in 2 animals, was easily detected and corrected. Conclusions — Real-time MR guidance of PFO closure, without the use of ionizing radiation, is feasible in an animal model.
- Open Access
- 23 July 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 16 (2) , 201-208
Simultaneous real‐time visualization of the catheter tip and vascular anatomy for MR‐guided PTA of iliac arteries in an animal model
Purpose: To examine the feasibility of simultaneous MR real‐time active tip tracking and near real‐time depiction of the vascular anatomy for percutaneous angioplasty of iliac arteries under MR guidance.Materials and Methods: Nine surgically created stenoses of external iliac arteries in pigs were dilated with MR‐compatible balloon catheters (Cordis, Roden, The Netherlands). These catheters were equipped with a microcoil for active tracking of the catheter tip with an in‐plane update rate of 10 positions per second. The procedures were performed on an interventional 1.5 T Gyroscan ACS‐NT scanner (Philips, Best, The Netherlands). Real‐time calculation of images acquired by radial k‐space filling was performed on a specially designed backprojector exploiting the sliding window reconstruction technique (Philips Research Laboratories, Hamburg, Germany). The image update rate was 20 frames per second using a radial gradient‐echo technique (TR = 12 msec, TE = 3.3 msec, 300 radials). MR angiography and X‐ray digital subtraction angiography on the X‐ray system positioned in‐line next to the interventional MR system served as control for the angioplasty results.Results: Real‐time guidance and positioning of the balloon catheters was possible. The actual position of the catheter tip was indicated in the MR images without any time delay for the reconstruction of the anatomical MR images, which were updated with a rate of 20 frames per second. This yielded a combination of a roadmap and fluoroscopy image, in which the catheter position and the anatomical background image both were continuously updated in real time. Six out of nine stenoses were successfully dilated. The effects of the angioplasty could be visualized by the real‐time MR technique, as was proven by X‐ray digital subtraction angiography.Conclusion: Active tip tracking simultaneous with MRI of the vascular anatomy—both in real time—is possible with the applied technique, enabling MR‐guided percutaneous dilatation (PTA) of iliac arteries. J. Magn. Reson. Imaging 2002;16:201–208.
- 23 July 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 16 (2) , 201-208
Open AccessSimultaneous real‐time visualization of the catheter tip and vascular anatomy for MR‐guided PTA of iliac arteries in an animal model
Purpose: To examine the feasibility of simultaneous MR real‐time active tip tracking and near real‐time depiction of the vascular anatomy for percutaneous angioplasty of iliac arteries under MR guidance.Materials and Methods: Nine surgically created stenoses of external iliac arteries in pigs were dilated with MR‐compatible balloon catheters (Cordis, Roden, The Netherlands). These catheters were equipped with a microcoil for active tracking of the catheter tip with an in‐plane update rate of 10 positions per second. The procedures were performed on an interventional 1.5 T Gyroscan ACS‐NT scanner (Philips, Best, The Netherlands). Real‐time calculation of images acquired by radial k‐space filling was performed on a specially designed backprojector exploiting the sliding window reconstruction technique (Philips Research Laboratories, Hamburg, Germany). The image update rate was 20 frames per second using a radial gradient‐echo technique (TR = 12 msec, TE = 3.3 msec, 300 radials). MR angiography and X‐ray digital subtraction angiography on the X‐ray system positioned in‐line next to the interventional MR system served as control for the angioplasty results.Results: Real‐time guidance and positioning of the balloon catheters was possible. The actual position of the catheter tip was indicated in the MR images without any time delay for the reconstruction of the anatomical MR images, which were updated with a rate of 20 frames per second. This yielded a combination of a roadmap and fluoroscopy image, in which the catheter position and the anatomical background image both were continuously updated in real time. Six out of nine stenoses were successfully dilated. The effects of the angioplasty could be visualized by the real‐time MR technique, as was proven by X‐ray digital subtraction angiography.Conclusion: Active tip tracking simultaneous with MRI of the vascular anatomy—both in real time—is possible with the applied technique, enabling MR‐guided percutaneous dilatation (PTA) of iliac arteries. J. Magn. Reson. Imaging 2002;16:201–208.
- 16 April 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 105 (15) , 1772-1775
Artifact-Free In-Stent Lumen Visualization by Standard Magnetic Resonance Angiography Using a New Metallic Magnetic Resonance Imaging Stent
Background — Metallic stents cause susceptibility and radiofrequency artifacts on MR images, which, up to now, have not allowed for complete visualization of the stent lumen by MR angiography. The aim of this study was to investigate the potential of a new dedicated renal MRI stent for artifact-free in-stent lumen visualization in vitro and in a swine model. Methods and Results — In vitro investigations were performed with prototypes of balloon-expandable Aachen Resonance Renal MRI Stents dilated to diameters of 3 to 6 mm and placed in an aqueous gadolinium solution (1:25). Phase-contrast and contrast-enhanced T 1 -weighted gradient echo images were acquired. Renal MRI stents (n=12) were deployed in the renal arteries of 6 pigs. Renal arteries were examined with phase-contrast angiography and with flow measurements before and after stent placement in the stented area, respectively. Additionally, a contrast-enhanced, T 1 -weighted, spoiled-gradient echo sequence after administration of 0.2 mmol gadolinium-DTPA/kg body weight was performed after stent placement. The visibility of artifacts was analyzed on in vitro and in vivo images by two investigators who knew the stent positions. Stent positions were determined visually (in vitro) or by x-ray angiography (animal experiments). No artifacts were detected independent of the applied imaging sequence and the stent orientation to the main magnetic field. Conclusion — The examined prototypes of fully MR-compatible MRI stents allow artifact-free visualization of the stent lumen with phase-contrast and contrast-enhanced T 1 -weighted angiography, as well as phase-contrast flow measurements in the stented area.
- 16 April 2002
- Published by Wolters Kluwer Health in Circulation
- Vol. 105 (15) , 1772-1775
Artifact-Free In-Stent Lumen Visualization by Standard Magnetic Resonance Angiography Using a New Metallic Magnetic Resonance Imaging Stent
Background — Metallic stents cause susceptibility and radiofrequency artifacts on MR images, which, up to now, have not allowed for complete visualization of the stent lumen by MR angiography. The aim of this study was to investigate the potential of a new dedicated renal MRI stent for artifact-free in-stent lumen visualization in vitro and in a swine model. Methods and Results — In vitro investigations were performed with prototypes of balloon-expandable Aachen Resonance Renal MRI Stents dilated to diameters of 3 to 6 mm and placed in an aqueous gadolinium solution (1:25). Phase-contrast and contrast-enhanced T 1 -weighted gradient echo images were acquired. Renal MRI stents (n=12) were deployed in the renal arteries of 6 pigs. Renal arteries were examined with phase-contrast angiography and with flow measurements before and after stent placement in the stented area, respectively. Additionally, a contrast-enhanced, T 1 -weighted, spoiled-gradient echo sequence after administration of 0.2 mmol gadolinium-DTPA/kg body weight was performed after stent placement. The visibility of artifacts was analyzed on in vitro and in vivo images by two investigators who knew the stent positions. Stent positions were determined visually (in vitro) or by x-ray angiography (animal experiments). No artifacts were detected independent of the applied imaging sequence and the stent orientation to the main magnetic field. Conclusion — The examined prototypes of fully MR-compatible MRI stents allow artifact-free visualization of the stent lumen with phase-contrast and contrast-enhanced T 1 -weighted angiography, as well as phase-contrast flow measurements in the stented area.
- 7 March 2002
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 174 (3) , 283-285
Real-time-MR guidance for placement of a self-made fully MR-compatible atrial septal occluder: in vitro test
Purpose: This in vitro study investigated the feasibility to visualize the placement of three different atrial septal occluder systems using real-time MR control. Methods: The experiments were performed on an interventional 1.5 T high field whole body system. Real-time MR imaging was achieved by radial or spiral k-space filling in conjunction with the sliding window reconstruction technique yielding an imaging speed of 15 frames per second. The CardioSeal, Amplatzer Septal Occluder and a specially designed MR-compatible closure device were tested in a water bath. A punctured plastic wall served as model for the atrial septal defect. Results: The delivery systems of the CardioSeal and Amplatzer Occluder were ferromagnetic and caused substantial artifacts, making the device placement impossible, even if the magnetic forces would have been acceptable. The self-made prototype caused only minor susceptibility artifacts allowing its visualization on the MR images. The MR imaging techniques applied enabled real-time control of the occluder including steering through the artificial septal foramen and visualization of the occluder deployment. Conclusion: Real-time MR imaging allows for guidance and placement of an MR-compatible septal occluder in vitro suggesting the feasibility to perform atrial septal occlusion under MR-guidance in vivo as well. Zielsetzung: Ziel der In-vitro-Studie war es, die Möglichkeit der Echtzeit-MR-Kontrolle zur Platzierung dreier verschiedener Vorhofseptumverschlusssysteme zu untersuchen. Methoden: Die Untersuchungen wurden an einem interventionellen 1,5 T Ganzkörperkernspintomographen durchgeführt. Die radiale oder spirale k-Raumabtastung in Verbindung mit der Rekonstruktionstechnik des gleitenden Fensters erbrachte eine Bildwiederholrate von 15 Bildern pro Sekunde. Die Verschlusssysteme CardioSeal, Amplatzer Septal Occluder und ein selbst produziertes MR-kompatibles System wurden in einem Wasserbad getestet. Eine senkrecht im Wasserbad befestigte Plastikwand mit einem ausgestanzten Loch diente als Modell für den Vorhofseptumdefekt. Ergebnisse: Die Abwurfsysteme des CardioSeal und Amplatz Occluders waren jeweils ferromagnetisch und erzeugten derartig große Bildartefakte, dass eine Platzierung auch bei Vernachlässigung der magnetischen Anziehungskräfte nicht möglich war. Der selbst hergestellte Prototyp des voll MR-kompatiblen Systems ließ sich aufgrund seines kleinen Suszeptibilitätsartefakts gut auf den MR-Bildern darstellen. Die angewandten MR-Techniken erlaubten eine Echtzeitkontrolle der Sondierung des künstlichen Septumdefektes und der Freisetzung des Verschlusssystems. Schlussfolgerung: Die MR-gesteuerte Platzierung eines MR-kompatiblen Septumokluders ist unter Echtzeitbedingungen in vitro möglich, was die Machbarkeit einer solchen Intervention in vivo nahelegt.
- 7 March 2002
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 174 (3) , 283-285
Real-time-MR guidance for placement of a self-made fully MR-compatible atrial septal occluder: in vitro test
Purpose: This in vitro study investigated the feasibility to visualize the placement of three different atrial septal occluder systems using real-time MR control. Methods: The experiments were performed on an interventional 1.5 T high field whole body system. Real-time MR imaging was achieved by radial or spiral k-space filling in conjunction with the sliding window reconstruction technique yielding an imaging speed of 15 frames per second. The CardioSeal, Amplatzer Septal Occluder and a specially designed MR-compatible closure device were tested in a water bath. A punctured plastic wall served as model for the atrial septal defect. Results: The delivery systems of the CardioSeal and Amplatzer Occluder were ferromagnetic and caused substantial artifacts, making the device placement impossible, even if the magnetic forces would have been acceptable. The self-made prototype caused only minor susceptibility artifacts allowing its visualization on the MR images. The MR imaging techniques applied enabled real-time control of the occluder including steering through the artificial septal foramen and visualization of the occluder deployment. Conclusion: Real-time MR imaging allows for guidance and placement of an MR-compatible septal occluder in vitro suggesting the feasibility to perform atrial septal occlusion under MR-guidance in vivo as well. Zielsetzung: Ziel der In-vitro-Studie war es, die Möglichkeit der Echtzeit-MR-Kontrolle zur Platzierung dreier verschiedener Vorhofseptumverschlusssysteme zu untersuchen. Methoden: Die Untersuchungen wurden an einem interventionellen 1,5 T Ganzkörperkernspintomographen durchgeführt. Die radiale oder spirale k-Raumabtastung in Verbindung mit der Rekonstruktionstechnik des gleitenden Fensters erbrachte eine Bildwiederholrate von 15 Bildern pro Sekunde. Die Verschlusssysteme CardioSeal, Amplatzer Septal Occluder und ein selbst produziertes MR-kompatibles System wurden in einem Wasserbad getestet. Eine senkrecht im Wasserbad befestigte Plastikwand mit einem ausgestanzten Loch diente als Modell für den Vorhofseptumdefekt. Ergebnisse: Die Abwurfsysteme des CardioSeal und Amplatz Occluders waren jeweils ferromagnetisch und erzeugten derartig große Bildartefakte, dass eine Platzierung auch bei Vernachlässigung der magnetischen Anziehungskräfte nicht möglich war. Der selbst hergestellte Prototyp des voll MR-kompatiblen Systems ließ sich aufgrund seines kleinen Suszeptibilitätsartefakts gut auf den MR-Bildern darstellen. Die angewandten MR-Techniken erlaubten eine Echtzeitkontrolle der Sondierung des künstlichen Septumdefektes und der Freisetzung des Verschlusssystems. Schlussfolgerung: Die MR-gesteuerte Platzierung eines MR-kompatiblen Septumokluders ist unter Echtzeitbedingungen in vitro möglich, was die Machbarkeit einer solchen Intervention in vivo nahelegt.
- 1 June 2001
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 12 (6) , 753-756
Real-time MR Guidance for Inferior Vena Cava Filter Placement in an Animal Model
- 1 June 2001
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 12 (6) , 753-756
Real-time MR Guidance for Inferior Vena Cava Filter Placement in an Animal Model