Rainer Glöckl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rainer Glöckl has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Klaus Kenn
Institute for Pulmonary Rehabilitation, Schoen Klinik Berchtesgadener Land, Schoenau am Koenigssee, Germany
5 shared publicationsInga Jarosch
Institute for Pulmonary Rehabilitation, Schoen Klinik Berchtesgadener Land, Schoenau am Koenigssee, Germany
4 shared publications- Klaus Kenn
Schön Klinik Berchtesgadener Land
3 shared publications Tessa Schneeberger
Institute for Pulmonary Rehabilitation, Schoen Klinik Berchtesgadener Land, Schoenau am Koenigssee, Germany
3 shared publications- Inga Jarosch
Department of Respiratory Medicine and Pulmonary Rehabilitation, Schoen Klinik Berchtesgadener Land, Schoenau am Koenigssee, Germany
2 shared publications K. Schultz
Klinik Bad Reichenhall, Zentrum für Rehabilitation, Pneumologie und Orthopädie der DRV Bayern Süd, Bad Reichenhall
2 shared publications
Latest Publications
- 16 February 2022
- Published by Springer Nature in Pneumo-News
- Vol. 14 (1) , 30-39
Rehabilitation bei Post-COVID-19-Patienten - individuell und zielgerichtet
- 16 February 2022
- Published by Springer Nature in Pneumo-News
- Vol. 14 (1) , 30-39
Rehabilitation bei Post-COVID-19-Patienten - individuell und zielgerichtet
- 7 September 2020
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 56 (suppl 64)
Whole-body vibration training versus conventional balance training in patients with severe COPD – a randomized, controlled trial
Background: Whole-body vibration training (WBVT) performed on a vibration platform can significantly improve physical performance in COPD patients. It has been suggested that an important mechanism of this improvement is based on an improvement in balance. Aim of this study was to investigate the effects of WBVT versus conventional balance training on exercise performance. Methods: 48 patients with severe COPD (FEV1: 37±7 %pred.) and low exercise performance (6-minute walk distance (6MWD): 55±10 %pred.) were included in a randomized controlled trial during a 3-week inpatient pulmonary rehabilitation. All patients completed a standardized endurance and strength training program. Additionally, patients performed 4 different balance exercises 3x/week for 2x1 minute each either on a vibration platform (Galileo) at varying frequencies (5 - 26 Hz) (WBVT) or on a conventional therapy tool inducing an instable surface (CON). Results: 6MWD improved significantly in both groups (WBVT: 48±46m, p<0.001 vs. CON: 39±32m; p<0.001). Muscular performance during a two-legged jump increased significantly more in the WBVT group (+2.3±2.5 W/kg vs. -0.1±2.0 W/kg, p=0.001). Static balance performance also improved significantly more after WBVT (path length in Rombergstand: -38 mm vs. +41mm, tandem stand: -168 mm vs. +1 mm, single leg stance: -150mm vs. +2 mm; all group differences p<0.05). The 4-meter Gait Speed Test also increased significantly only within the WBVT group (0.08±0.14m/s², p=0.012 vs. 0.01±0.11m/s², p=0.71). Conclusion: WBVT can improve balance and muscular performance significantly more compared to conventional balance training.
- 7 September 2020
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 56 (suppl 64)
Whole-body vibration training versus conventional balance training in patients with severe COPD – a randomized, controlled trial
Background: Whole-body vibration training (WBVT) performed on a vibration platform can significantly improve physical performance in COPD patients. It has been suggested that an important mechanism of this improvement is based on an improvement in balance. Aim of this study was to investigate the effects of WBVT versus conventional balance training on exercise performance. Methods: 48 patients with severe COPD (FEV1: 37±7 %pred.) and low exercise performance (6-minute walk distance (6MWD): 55±10 %pred.) were included in a randomized controlled trial during a 3-week inpatient pulmonary rehabilitation. All patients completed a standardized endurance and strength training program. Additionally, patients performed 4 different balance exercises 3x/week for 2x1 minute each either on a vibration platform (Galileo) at varying frequencies (5 - 26 Hz) (WBVT) or on a conventional therapy tool inducing an instable surface (CON). Results: 6MWD improved significantly in both groups (WBVT: 48±46m, p<0.001 vs. CON: 39±32m; p<0.001). Muscular performance during a two-legged jump increased significantly more in the WBVT group (+2.3±2.5 W/kg vs. -0.1±2.0 W/kg, p=0.001). Static balance performance also improved significantly more after WBVT (path length in Rombergstand: -38 mm vs. +41mm, tandem stand: -168 mm vs. +1 mm, single leg stance: -150mm vs. +2 mm; all group differences p<0.05). The 4-meter Gait Speed Test also increased significantly only within the WBVT group (0.08±0.14m/s², p=0.012 vs. 0.01±0.11m/s², p=0.71). Conclusion: WBVT can improve balance and muscular performance significantly more compared to conventional balance training.
- 28 September 2019
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 54 (suppl 63) , PA1229
Comparison of continuous versus various demand oxygen delivery systems during standardized walking in COPD – a single-blinded, randomized, cross-over study
Background: Supplemental oxygen is a recommended therapy option in hypoxemic COPD patients. Usually, supplemental oxygen is provided by continuous flow (CF). However, demand oxygen delivery systems (DODS) that provide an oxygen bolus only during inhalation have gained increasing interest as they prolong oxygen cylinder life. However, there is a lack of evidence if different DODS devices and are equivalent CF. Methods: Hypoxemic COPD patients that were on oxygen therapy were included in this prospective single-blinded, randomized, cross-over trial. Patient performed 3 endurance shuttle walk tests (ESWT) at 85% of their maximum walking speed in random order under following conditions: (A) with CF (ESWT-CF), (B) with a DODS based on liquid oxygen (ESWT-DL) and (C) an oxygen concentrator (ESWT-DC). The primary outcome was oxygen saturation at ESWT isotime. Secondary outcomes were the total ESWT duration, heart rate (HR) and breathing frequency (BF) at isotime and end-exercise dyspnea. Results: 70 patients (FEV1 32±9%) completed the study. Oxygen saturation at ESWT isotime was not clinically different between devices: 90±5% (CF), 88±6% (DL) and 89±5% (DC). Also total walking distance was similar: 349±320m (CF), 338±290m (DL) and 315±267m (DC) (p=n.s.). HR, BF and dyspnea were also comparable at isotime. Conclusion: Oxygen supplementation via DODS (based on liquid oxygen or as a concentrator) yielded comparable physiological effects and exercise performance in hypoxemic COPD. Since single subjects showed clinically relevant differences between devices, individual oxygen saturation testing should be recommended.
- 28 September 2019
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 54 (suppl 63) , PA1229
Comparison of continuous versus various demand oxygen delivery systems during standardized walking in COPD – a single-blinded, randomized, cross-over study
Background: Supplemental oxygen is a recommended therapy option in hypoxemic COPD patients. Usually, supplemental oxygen is provided by continuous flow (CF). However, demand oxygen delivery systems (DODS) that provide an oxygen bolus only during inhalation have gained increasing interest as they prolong oxygen cylinder life. However, there is a lack of evidence if different DODS devices and are equivalent CF. Methods: Hypoxemic COPD patients that were on oxygen therapy were included in this prospective single-blinded, randomized, cross-over trial. Patient performed 3 endurance shuttle walk tests (ESWT) at 85% of their maximum walking speed in random order under following conditions: (A) with CF (ESWT-CF), (B) with a DODS based on liquid oxygen (ESWT-DL) and (C) an oxygen concentrator (ESWT-DC). The primary outcome was oxygen saturation at ESWT isotime. Secondary outcomes were the total ESWT duration, heart rate (HR) and breathing frequency (BF) at isotime and end-exercise dyspnea. Results: 70 patients (FEV1 32±9%) completed the study. Oxygen saturation at ESWT isotime was not clinically different between devices: 90±5% (CF), 88±6% (DL) and 89±5% (DC). Also total walking distance was similar: 349±320m (CF), 338±290m (DL) and 315±267m (DC) (p=n.s.). HR, BF and dyspnea were also comparable at isotime. Conclusion: Oxygen supplementation via DODS (based on liquid oxygen or as a concentrator) yielded comparable physiological effects and exercise performance in hypoxemic COPD. Since single subjects showed clinically relevant differences between devices, individual oxygen saturation testing should be recommended.
- Open Access
- 28 December 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (12) , e0209069
A randomized cross-over trial on the direct effects of oxygen supplementation therapy using different devices on cycle endurance in hypoxemic patients with Interstitial Lung Disease
In patients with interstitial lung disease (ILD) a cardinal feature is exercise intolerance, often associated with significant dyspnea and severe hypoxemia. Supplemental oxygen therapy may be offered during exercise. The Oxymizer is a nasal cannula with an incorporated reservoir with the potential to deliver higher oxygen doses to the patient. The primary aim was to investigate the effect of supplemental oxygen delivered via Oxymizer compared to a conventional nasal cannula (CNC) in patients with ILD during constant work rate tests (CWRT). Secondary aim was to evaluate effects on oxygen saturation (SpO2), dyspnea and heart rate at isotime. In this randomized crossover study 24 ILD patients established on long-term oxygen treatment were included. Patients performed four cycling CWRT at 70% of their peak work rate; twice with the Oxymizer and twice with the CNC. Twenty-one patients finished all CWRTs (age 60 ± 10.9 years, VC 55.4 ± 23.0%predicted). Cycle endurance time was significantly higher while using the Oxymizer compared to CNC (718 ± 485 vs. 680 ± 579 seconds, p = 0.02), and SpO2 at isotime was significantly higher while using the Oxymizer (85.5 ± 6.7 vs. 82.8± 7.2, p = 0.01). Fifteen of the 21 (71%) patients cycled longer with the Oxymizer. There were no significant differences for dyspnea and heart rate. Supplemental oxygen provided by the Oxymizer significantly, but modestly, improved cycle endurance time and SpO2 at isotime in ILD patients compared to CNC.
- 28 December 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (12) , e0209069
Open AccessA randomized cross-over trial on the direct effects of oxygen supplementation therapy using different devices on cycle endurance in hypoxemic patients with Interstitial Lung Disease
In patients with interstitial lung disease (ILD) a cardinal feature is exercise intolerance, often associated with significant dyspnea and severe hypoxemia. Supplemental oxygen therapy may be offered during exercise. The Oxymizer is a nasal cannula with an incorporated reservoir with the potential to deliver higher oxygen doses to the patient. The primary aim was to investigate the effect of supplemental oxygen delivered via Oxymizer compared to a conventional nasal cannula (CNC) in patients with ILD during constant work rate tests (CWRT). Secondary aim was to evaluate effects on oxygen saturation (SpO2), dyspnea and heart rate at isotime. In this randomized crossover study 24 ILD patients established on long-term oxygen treatment were included. Patients performed four cycling CWRT at 70% of their peak work rate; twice with the Oxymizer and twice with the CNC. Twenty-one patients finished all CWRTs (age 60 ± 10.9 years, VC 55.4 ± 23.0%predicted). Cycle endurance time was significantly higher while using the Oxymizer compared to CNC (718 ± 485 vs. 680 ± 579 seconds, p = 0.02), and SpO2 at isotime was significantly higher while using the Oxymizer (85.5 ± 6.7 vs. 82.8± 7.2, p = 0.01). Fifteen of the 21 (71%) patients cycled longer with the Oxymizer. There were no significant differences for dyspnea and heart rate. Supplemental oxygen provided by the Oxymizer significantly, but modestly, improved cycle endurance time and SpO2 at isotime in ILD patients compared to CNC.
- 28 August 2018
- Published by Springer Nature in Pneumo-News
- Vol. 10 (5) , 13-14
Raucherjahre zählen bei COPD-Entstehung mehr als tägliche Zigaretten
- 28 August 2018
- Published by Springer Nature in Pneumo-News
- Vol. 10 (5) , 13-14
Raucherjahre zählen bei COPD-Entstehung mehr als tägliche Zigaretten
- 1 August 2018
- Published by Elsevier in Respiratory Physiology & Neurobiology
- Vol. 254, 64-72
Cerebral oxygen availability during exercise in COPD patients with cognitive impairment
- 1 August 2018
- Published by Elsevier in Respiratory Physiology & Neurobiology
- Vol. 254, 64-72
Cerebral oxygen availability during exercise in COPD patients with cognitive impairment
- 22 June 2018
- Published by Springer Nature in Pneumo-News
- Vol. 10 (4) , 21-22
Putzmittel sind schädlich — vor allem für die Frauenlungen
- 22 June 2018
- Published by Springer Nature in Pneumo-News
- Vol. 10 (4) , 21-22
Putzmittel sind schädlich — vor allem für die Frauenlungen
- Open Access
- 14 April 2018
- Published by Springer Nature in Pneumo-News
- Vol. 10 (2) , 18
Musikhören beim Gehtraining reduziert Dyspnoe bei COPD
- 14 April 2018
- Published by Springer Nature in Pneumo-News
- Vol. 10 (2) , 18
Open AccessMusikhören beim Gehtraining reduziert Dyspnoe bei COPD
- 14 April 2018
- Published by Springer Nature in Pneumo-News
- Vol. 10 (2) , 19-20
Multimodale Reha bei Lungenfibrose effektiv
- 14 April 2018
- Published by Springer Nature in Pneumo-News
- Vol. 10 (2) , 19-20
Multimodale Reha bei Lungenfibrose effektiv