Peter Trueb
Research Subjects
Peter Trueb has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
B. A. Sobott
School of Physics, The University of Melbourne, Victoria 3010, Australia
2 shared publicationsC. Broennimann
DECTRIS Ltd, 5400 Baden, Switzerland
2 shared publicationsM. Kobas
DECTRIS Ltd, 5400 Baden, Switzerland
2 shared publications- Catherine Dejoie
European Synchrotron Radiation Facility
1 shared publication Christian Broennimann
DECTRIS Ltd., Täfernweg 1, CH-5405, Baden-Dättwil, Switzerland
1 shared publicationChristian Brönnimann
DECTRIS Ltd
1 shared publication
Latest Publications
- Open Access
- 1 March 2019
- Published by Springer Nature in Nature Physics
- Vol. 15 (3) , 302
π ≈ 3.141, not only now, but forever
- 1 March 2019
- Published by Springer Nature in Nature Physics
- Vol. 15 (3) , 302
Open Accessπ ≈ 3.141, not only now, but forever
- Open Access
- 13 September 2017
- Published by Wiley in Medical Physics
- Vol. 44 (9) , e207-e214
Assessment of the spectral performance of hybrid photon counting x‐ray detectors
Purpose: Hybrid Photon Counting (HPC) detectors profoundly improved x‐ray diffraction experiments at third generation synchrotron facilities. Enabling the simultaneous measurement of x‐ray intensities in multiple energy bins, they also have many potential applications in the field of medical imaging. A prerequisite for this is a clean spectral response. To quantify how efficiently HPC detectors are able to assign photons to the correct energy bin, a quantity called Spectral Efficiency (SE) is introduced. This figure of merit measures the number of x‐rays with correctly assigned energy normalized to the number of incoming photons.Methods: A prototype HPC detector has been used to perform precision measurements of x‐ray spectra at the BESSY synchrotron. The detector consists of a novel ASIC with pixels of 75 × 75 μm2 size and a 750 μm thick CdTe sensor. The experimental data are complemented by the results of a Monte‐Carlo (MC) simulation, which not only includes the physical detection process but also pulse pile‐up at high photon fluxes. The spectra and the measured photon flux are used to infer the Spectral Efficiency.Results: In the energy range from 10 to 60 keV, both the Quantum Efficiency and the Spectral Efficiency were precisely measured and simulated. Good agreement between simulation and experiment has been achieved. For the small pixels of the prototype detector, a SE between 15% and 77% has been determined. The MC simulation is used to predict the SE for various pixel sizes at different photon fluxes. For a typical flux of 5∙107 photons/mm2/s used in human Computed Tomography (CT), the highest SE is achieved for pixel sizes in the range between 150 × 150 μm2 and 300 × 300 μm2.Conclusions: The Spectral Efficiency turns out to be a useful figure of merit to quantify the spectral performance of HPC detectors. It allows a quantitative comparison of detectors with different sensor and ASIC configurations over a broad range of x‐ray energies and fluxes. The maximization of the SE is a prerequisite for a successful usage of HPC detectors in the field of medical imaging.
- 13 September 2017
- Published by Wiley in Medical Physics
- Vol. 44 (9) , e207-e214
Open AccessAssessment of the spectral performance of hybrid photon counting x‐ray detectors
Purpose: Hybrid Photon Counting (HPC) detectors profoundly improved x‐ray diffraction experiments at third generation synchrotron facilities. Enabling the simultaneous measurement of x‐ray intensities in multiple energy bins, they also have many potential applications in the field of medical imaging. A prerequisite for this is a clean spectral response. To quantify how efficiently HPC detectors are able to assign photons to the correct energy bin, a quantity called Spectral Efficiency (SE) is introduced. This figure of merit measures the number of x‐rays with correctly assigned energy normalized to the number of incoming photons.Methods: A prototype HPC detector has been used to perform precision measurements of x‐ray spectra at the BESSY synchrotron. The detector consists of a novel ASIC with pixels of 75 × 75 μm2 size and a 750 μm thick CdTe sensor. The experimental data are complemented by the results of a Monte‐Carlo (MC) simulation, which not only includes the physical detection process but also pulse pile‐up at high photon fluxes. The spectra and the measured photon flux are used to infer the Spectral Efficiency.Results: In the energy range from 10 to 60 keV, both the Quantum Efficiency and the Spectral Efficiency were precisely measured and simulated. Good agreement between simulation and experiment has been achieved. For the small pixels of the prototype detector, a SE between 15% and 77% has been determined. The MC simulation is used to predict the SE for various pixel sizes at different photon fluxes. For a typical flux of 5∙107 photons/mm2/s used in human Computed Tomography (CT), the highest SE is achieved for pixel sizes in the range between 150 × 150 μm2 and 300 × 300 μm2.Conclusions: The Spectral Efficiency turns out to be a useful figure of merit to quantify the spectral performance of HPC detectors. It allows a quantitative comparison of detectors with different sensor and ASIC configurations over a broad range of x‐ray energies and fluxes. The maximization of the SE is a prerequisite for a successful usage of HPC detectors in the field of medical imaging.
- 1 January 2016
- Published by Springer Nature
- p. 995-1027
Hybrid Pixel Photon Counting X-Ray Detectors for Synchrotron Radiation
- 1 January 2016
- Published by Springer Nature
- p. 995-1027
Hybrid Pixel Photon Counting X-Ray Detectors for Synchrotron Radiation
- Open Access
- 9 April 2015
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 22 (3) , 701-707
Bunch mode specific rate corrections for PILATUS3 detectors
PILATUS X-ray detectors are in operation at many synchrotron beamlines around the world. This article reports on the characterization of the new PILATUS3 detector generation at high count rates. As for all counting detectors, the measured intensities have to be corrected for the dead-time of the counting mechanism at high photon fluxes. The large number of different bunch modes at these synchrotrons as well as the wide range of detector settings presents a challenge for providing accurate corrections. To avoid the intricate measurement of the count rate behaviour for every bunch mode, a Monte Carlo simulation of the counting mechanism has been implemented, which is able to predict the corrections for arbitrary bunch modes and a wide range of detector settings. This article compares the simulated results with experimental data acquired at different synchrotrons. It is found that the usage of bunch mode specific corrections based on this simulation improves the accuracy of the measured intensities by up to 40% for high photon rates and highly structured bunch modes. For less structured bunch modes, the instant retrigger technology of PILATUS3 detectors substantially reduces the dependency of the rate correction on the bunch mode. The acquired data also demonstrate that the instant retrigger technology allows for data acquisition up to 15 million photons per second per pixel.
- 9 April 2015
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 22 (3) , 701-707
Open AccessBunch mode specific rate corrections for PILATUS3 detectors
PILATUS X-ray detectors are in operation at many synchrotron beamlines around the world. This article reports on the characterization of the new PILATUS3 detector generation at high count rates. As for all counting detectors, the measured intensities have to be corrected for the dead-time of the counting mechanism at high photon fluxes. The large number of different bunch modes at these synchrotrons as well as the wide range of detector settings presents a challenge for providing accurate corrections. To avoid the intricate measurement of the count rate behaviour for every bunch mode, a Monte Carlo simulation of the counting mechanism has been implemented, which is able to predict the corrections for arbitrary bunch modes and a wide range of detector settings. This article compares the simulated results with experimental data acquired at different synchrotrons. It is found that the usage of bunch mode specific corrections based on this simulation improves the accuracy of the measured intensities by up to 40% for high photon rates and highly structured bunch modes. For less structured bunch modes, the instant retrigger technology of PILATUS3 detectors substantially reduces the dependency of the rate correction on the bunch mode. The acquired data also demonstrate that the instant retrigger technology allows for data acquisition up to 15 million photons per second per pixel.
- 25 February 2015
- Published by Springer Nature
- p. 1-29
Hybrid Pixel Photon Counting X-Ray Detectors for Synchrotron Radiation
- 25 February 2015
- Published by Springer Nature
- p. 1-29
Hybrid Pixel Photon Counting X-Ray Detectors for Synchrotron Radiation
- Open Access
- 16 March 2012
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 19 (3) , 347-351
Improved count rate corrections for highest data quality with PILATUS detectors
The PILATUS detector system is widely used for X-ray experiments at third-generation synchrotrons. It is based on a hybrid technology combining a pixelated silicon sensor with a CMOS readout chip. Its single-photon-counting capability ensures precise and noise-free measurements. The counting mechanism introduces a short dead-time after each hit, which becomes significant for rates above 10(6) photons s(-1) pixel(-1). The resulting loss in the number of counted photons is corrected for by applying corresponding rate correction factors. This article presents the results of a Monte Carlo simulation which computes the correction factors taking into account the detector settings as well as the time structure of the X-ray beam at the synchrotron. The results of the simulation show good agreement with experimentally determined correction factors for various detector settings at different synchrotrons. The application of accurate rate correction factors improves the X-ray data quality acquired at high photon fluxes. Furthermore, it is shown that the use of fast detector settings in combination with an optimized time structure of the X-ray beam allows for measurements up to rates of 10(7) photons s(-1) pixel(-1).
- 16 March 2012
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 19 (3) , 347-351
Open AccessImproved count rate corrections for highest data quality with PILATUS detectors
The PILATUS detector system is widely used for X-ray experiments at third-generation synchrotrons. It is based on a hybrid technology combining a pixelated silicon sensor with a CMOS readout chip. Its single-photon-counting capability ensures precise and noise-free measurements. The counting mechanism introduces a short dead-time after each hit, which becomes significant for rates above 10(6) photons s(-1) pixel(-1). The resulting loss in the number of counted photons is corrected for by applying corresponding rate correction factors. This article presents the results of a Monte Carlo simulation which computes the correction factors taking into account the detector settings as well as the time structure of the X-ray beam at the synchrotron. The results of the simulation show good agreement with experimentally determined correction factors for various detector settings at different synchrotrons. The application of accurate rate correction factors improves the X-ray data quality acquired at high photon fluxes. Furthermore, it is shown that the use of fast detector settings in combination with an optimized time structure of the X-ray beam allows for measurements up to rates of 10(7) photons s(-1) pixel(-1).