    π ≈ 3.141, not only now, but forever

    by Peter Trueb

  • Open Access

    Assessment of the spectral performance of hybrid photon counting x‐ray detectors

    by Peter Trueb, Pietro Zambon, Christian Broennimann

    Purpose: Hybrid Photon Counting (HPC) detectors profoundly improved x‐ray diffraction experiments at third generation synchrotron facilities. Enabling the simultaneous measurement of x‐ray intensities in multiple energy bins, they also have many potential applications in the field of medical imaging. A prerequisite for this is a clean spectral response. To quantify how efficiently HPC detectors are able to assign photons to the correct energy bin, a quantity called Spectral Efficiency (SE) is introduced. This figure of merit measures the number of x‐rays with correctly assigned energy normalized to the number of incoming photons.Methods: A prototype HPC detector has been used to perform precision measurements of x‐ray spectra at the BESSY synchrotron. The detector consists of a novel ASIC with pixels of 75 × 75 μm2 size and a 750 μm thick CdTe sensor. The experimental data are complemented by the results of a Monte‐Carlo (MC) simulation, which not only includes the physical detection process but also pulse pile‐up at high photon fluxes. The spectra and the measured photon flux are used to infer the Spectral Efficiency.Results: In the energy range from 10 to 60 keV, both the Quantum Efficiency and the Spectral Efficiency were precisely measured and simulated. Good agreement between simulation and experiment has been achieved. For the small pixels of the prototype detector, a SE between 15% and 77% has been determined. The MC simulation is used to predict the SE for various pixel sizes at different photon fluxes. For a typical flux of 5∙107 photons/mm2/s used in human Computed Tomography (CT), the highest SE is achieved for pixel sizes in the range between 150 × 150 μm2 and 300 × 300 μm2.Conclusions: The Spectral Efficiency turns out to be a useful figure of merit to quantify the spectral performance of HPC detectors. It allows a quantitative comparison of detectors with different sensor and ASIC configurations over a broad range of x‐ray energies and fluxes. The maximization of the SE is a prerequisite for a successful usage of HPC detectors in the field of medical imaging.


  • Open Access

    Bunch mode specific rate corrections for PILATUS3 detectors

    by P. Trueb, C. Dejoie, M. Kobas, P. Pattison, D. J. Peake, V. Radicci, B. A. Sobott, D. A. Walko, C. Broennimann

    PILATUS X-ray detectors are in operation at many synchrotron beamlines around the world. This article reports on the characterization of the new PILATUS3 detector generation at high count rates. As for all counting detectors, the measured intensities have to be corrected for the dead-time of the counting mechanism at high photon fluxes. The large number of different bunch modes at these synchrotrons as well as the wide range of detector settings presents a challenge for providing accurate corrections. To avoid the intricate measurement of the count rate behaviour for every bunch mode, a Monte Carlo simulation of the counting mechanism has been implemented, which is able to predict the corrections for arbitrary bunch modes and a wide range of detector settings. This article compares the simulated results with experimental data acquired at different synchrotrons. It is found that the usage of bunch mode specific corrections based on this simulation improves the accuracy of the measured intensities by up to 40% for high photon rates and highly structured bunch modes. For less structured bunch modes, the instant retrigger technology of PILATUS3 detectors substantially reduces the dependency of the rate correction on the bunch mode. The acquired data also demonstrate that the instant retrigger technology allows for data acquisition up to 15 million photons per second per pixel.


  • Open Access

    Improved count rate corrections for highest data quality with PILATUS detectors

    by P. Trueb, B. A. Sobott, R. Schnyder, T. Loeliger, M. Schneebeli, M. Kobas, R. P. Rassool, D. J. Peake, C. Broennimann

    The PILATUS detector system is widely used for X-ray experiments at third-generation synchrotrons. It is based on a hybrid technology combining a pixelated silicon sensor with a CMOS readout chip. Its single-photon-counting capability ensures precise and noise-free measurements. The counting mechanism introduces a short dead-time after each hit, which becomes significant for rates above 10(6) photons s(-1) pixel(-1). The resulting loss in the number of counted photons is corrected for by applying corresponding rate correction factors. This article presents the results of a Monte Carlo simulation which computes the correction factors taking into account the detector settings as well as the time structure of the X-ray beam at the synchrotron. The results of the simulation show good agreement with experimentally determined correction factors for various detector settings at different synchrotrons. The application of accurate rate correction factors improves the X-ray data quality acquired at high photon fluxes. Furthermore, it is shown that the use of fast detector settings in combination with an optimized time structure of the X-ray beam allows for measurements up to rates of 10(7) photons s(-1) pixel(-1).