Thomas Gösling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thomas Gösling has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Christian Krettek
Professor em., Trauma Department, Hannover Medical School, Hannover, Germany
11 shared publications Stefan Hankemeier
3 shared publicationsTobias Hufner
3 shared publicationsFriedrich Wahl
2 shared publicationsM. Richter
Medizinische Hochschule Hannover
2 shared publicationsT. Hufner
Hannover Medical School, Hannover, Germany
2 shared publications
Latest Publications
- 30 May 2010
- Published by Springer Nature in Der Chirurg
- Vol. 81 (7) , 657-680
Diagnostik und Therapie primärer Knochentumoren
Primary bone tumors can be either benign or malignant. Metastization is a characteristic feature of malignant bone tumors. Malignant tumors are characterized by a local aggressive and destructive behavior. The behavior of a tumor is dependent on its entity, the differentiation grade and localization and these factors are of decisive importance for the correct therapy. Even benign tumors can behave very aggressively. Different stages are defined. Patient history and conventional radiographs are the most powerful primary diagnostic tools. Many tumors show typical characteristics and if a malignant lesion is suspected a biopsy should be carried out. Several quality standards have to be respected when making the biopsy. The approach to malignant tumors is always interdisciplinary. Several biological as well as alloplastic reconstruction techniques exist. The treatment of primary malignant bone tumors requires a lot of experience and should only be done in specialized centers.
- 30 May 2010
- Published by Springer Nature in Der Chirurg
- Vol. 81 (7) , 657-680
Diagnostik und Therapie primärer Knochentumoren
Primary bone tumors can be either benign or malignant. Metastization is a characteristic feature of malignant bone tumors. Malignant tumors are characterized by a local aggressive and destructive behavior. The behavior of a tumor is dependent on its entity, the differentiation grade and localization and these factors are of decisive importance for the correct therapy. Even benign tumors can behave very aggressively. Different stages are defined. Patient history and conventional radiographs are the most powerful primary diagnostic tools. Many tumors show typical characteristics and if a malignant lesion is suspected a biopsy should be carried out. Several quality standards have to be respected when making the biopsy. The approach to malignant tumors is always interdisciplinary. Several biological as well as alloplastic reconstruction techniques exist. The treatment of primary malignant bone tumors requires a lot of experience and should only be done in specialized centers.
- 22 April 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 129 (11) , 1521-1526
Computer-assisted antetorsion control prevents malrotation in femoral nailing: an experimental study and preliminary clinical case series
Materials and methods The effect of fluoroscopy-based navigation for femoral fracture reduction on the prevention of malrotation was examined in an experimental setting followed by a first case series. Eleven cadaver femurs were used. All femurs were reduced by closed methods. An optoelectronic navigation system was utilized to check for fragment reduction and alignment. Fluoroscopic control without navigation was used as the control group. The Six Sigma Analysis [offset capability index (C pk) = 1.3] was used to compare the probability of outliers of more than 15°. In the clinical case series the same navigation tool was used in ten non-consecutive patients with femoral fractures. Torsional differences between both legs were measured postoperatively by CT scan. Results The highest malrotation in the navigated group was 7.0° for the cadaver testings, while two femurs in the control group showed a difference of more than 10° (10.3°, 17.4°). Only the navigated group showed a sufficient offset capability index (C pk-navigated = 1.83; C pk-conventional = 0.59). In the clinical series nine femurs were successfully reduced by navigation control. The average malrotation was 6.6°. No patient had a torsional difference of more than 10°. Conclusion Navigated femoral nailing reduces the risk for outliers of postoperative torsional differences and might avoid revision surgery for malrotation. Level of evidence IV.
- 22 April 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 129 (11) , 1521-1526
Computer-assisted antetorsion control prevents malrotation in femoral nailing: an experimental study and preliminary clinical case series
Materials and methods The effect of fluoroscopy-based navigation for femoral fracture reduction on the prevention of malrotation was examined in an experimental setting followed by a first case series. Eleven cadaver femurs were used. All femurs were reduced by closed methods. An optoelectronic navigation system was utilized to check for fragment reduction and alignment. Fluoroscopic control without navigation was used as the control group. The Six Sigma Analysis [offset capability index (C pk) = 1.3] was used to compare the probability of outliers of more than 15°. In the clinical case series the same navigation tool was used in ten non-consecutive patients with femoral fractures. Torsional differences between both legs were measured postoperatively by CT scan. Results The highest malrotation in the navigated group was 7.0° for the cadaver testings, while two femurs in the control group showed a difference of more than 10° (10.3°, 17.4°). Only the navigated group showed a sufficient offset capability index (C pk-navigated = 1.83; C pk-conventional = 0.59). In the clinical series nine femurs were successfully reduced by navigation control. The average malrotation was 6.6°. No patient had a torsional difference of more than 10°. Conclusion Navigated femoral nailing reduces the risk for outliers of postoperative torsional differences and might avoid revision surgery for malrotation. Level of evidence IV.
- 1 October 2006
- Published by Wolters Kluwer Health
- Vol. 61 (4) , 900-904
Overdistraction of the Fracture Eases Reduction in Delayed Femoral Nailing: Results of Intraoperative Force Measurements
(Initial) primary external fixation of femoral shaft fractures followed by secondary intramedullary nailing is a concept of damage control orthopedics. We hypothesized that external fixation with overdistraction of the fracture might reduce reduction forces and shorten reduction time during the secondary nailing. An experimental study on seven patients with eight fractures of the femoral shaft was conducted. Intraoperative reduction forces were determined in all patients using a load cell. The amount of distraction was measured on the latest radiographs before nailing. The reduction time was recorded as an indirect indicator of the intricacy of reposition. Reduction forces and reduction times were compared between those fractures fixed with shortening (Group A) and those fixed in distraction (Group B). Three femurs showed some shortening and five femurs showed some distraction within the fracture. The maximum measured distraction force along the shaft axis was 396 N. On average the maximal force was 336 N (+/- 51.9 N) in Group A and 200 N (+/- 43.1 N) in Group B. This difference is statistically significant (p = 0.007). The average reduction time was 28.3 minutes (+/- 21.8 minutes) in Group A and 5.8 minutes (+/- 4.0 minutes) in Group B. This difference shows a trend toward significance (p = 0.056). Fracture shortening leads to higher restraining forces and consequently prolonged reduction time in delayed nailing. Overdistraction should be performed as soon as possible under careful soft-tissue monitoring.
- 1 October 2006
- Published by Wolters Kluwer Health
- Vol. 61 (4) , 900-904
Overdistraction of the Fracture Eases Reduction in Delayed Femoral Nailing: Results of Intraoperative Force Measurements
(Initial) primary external fixation of femoral shaft fractures followed by secondary intramedullary nailing is a concept of damage control orthopedics. We hypothesized that external fixation with overdistraction of the fracture might reduce reduction forces and shorten reduction time during the secondary nailing. An experimental study on seven patients with eight fractures of the femoral shaft was conducted. Intraoperative reduction forces were determined in all patients using a load cell. The amount of distraction was measured on the latest radiographs before nailing. The reduction time was recorded as an indirect indicator of the intricacy of reposition. Reduction forces and reduction times were compared between those fractures fixed with shortening (Group A) and those fixed in distraction (Group B). Three femurs showed some shortening and five femurs showed some distraction within the fracture. The maximum measured distraction force along the shaft axis was 396 N. On average the maximal force was 336 N (+/- 51.9 N) in Group A and 200 N (+/- 43.1 N) in Group B. This difference is statistically significant (p = 0.007). The average reduction time was 28.3 minutes (+/- 21.8 minutes) in Group A and 5.8 minutes (+/- 4.0 minutes) in Group B. This difference shows a trend toward significance (p = 0.056). Fracture shortening leads to higher restraining forces and consequently prolonged reduction time in delayed nailing. Overdistraction should be performed as soon as possible under careful soft-tissue monitoring.
- Open Access
- 19 January 2006
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 24 (3) , 333-338
Forces and torques during fracture reduction: Intraoperative measurements in the femur
Reduction is a crucial step in fracture treatment. We determined intraoperative peak forces and torques during fracture reduction in seven patients with eight fractures of the femoral shaft. All fractures were temporarily stabilized by external fixation. Force and torque measurements were performed during the subsequent intramedullary nailing procedure. A three‐dimensional load cell was attached to the distal femur fragment using two Schanz screws. All forces and torques were registered on‐line during the reduction process. The maximum resulting force was 411 N, the maximum resulting torque 74 N · m. The highest force was observed along the shaft axis with 396 N for distraction. The maximum torque value was measured around the frontal axis, being 74 N · m for antecurvature. These results may assist the development of new reduction techniques and devices. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 24:333–338, 2006
- 19 January 2006
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 24 (3) , 333-338
Open AccessForces and torques during fracture reduction: Intraoperative measurements in the femur
Reduction is a crucial step in fracture treatment. We determined intraoperative peak forces and torques during fracture reduction in seven patients with eight fractures of the femoral shaft. All fractures were temporarily stabilized by external fixation. Force and torque measurements were performed during the subsequent intramedullary nailing procedure. A three‐dimensional load cell was attached to the distal femur fragment using two Schanz screws. All forces and torques were registered on‐line during the reduction process. The maximum resulting force was 411 N, the maximum resulting torque 74 N · m. The highest force was observed along the shaft axis with 396 N for distraction. The maximum torque value was measured around the frontal axis, being 74 N · m for antecurvature. These results may assist the development of new reduction techniques and devices. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 24:333–338, 2006
- 1 November 2005
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 19 (10) , 744-747
Minimally Invasive Exchange Tibial Nailing for a Broken Solid Nail
We present a minimally invasive technique for the removal of a broken solid tibial nail. A special device was invented that minimizes the extraction difficulties. After minimal over-reaming, the device is slid in an antegrade fashion over the nail and locked. Retraction is safe and easy. This article is an illustrative case-presentation describing the device and the surgical technique.
- 1 November 2005
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 19 (10) , 744-747
Minimally Invasive Exchange Tibial Nailing for a Broken Solid Nail
We present a minimally invasive technique for the removal of a broken solid tibial nail. A special device was invented that minimizes the extraction difficulties. After minimal over-reaming, the device is slid in an antegrade fashion over the nail and locked. Retraction is safe and easy. This article is an illustrative case-presentation describing the device and the surgical technique.
- 1 October 2005
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 439 (&NA;) , 207-214
Single Lateral Locked Screw Plating of Bicondylar Tibial Plateau Fractures
We prospectively followed a case series of 68 patients with 69 AO/ASIF 41-C-type fractures treated with the Less Invasive Stabilization System for the proximal lateral tibia. We assessed malreduction, secondary loss of reduction, and infection rates in patients with a locked screw plate for unilateral fixation of bicondylar fractures. Sixty-two (91%) patients returned for final followup (range, 11-13 months). Malreduction and malalignment were defined as an intraarticular step-off of 2 mm or greater, or as a malalignment in the frontal or sagittal plane greater than 5°. Fourteen fractures were open. Primary bone grafting was done in 13 patients. Significant malreduction was seen in 16 patients. There were four superficial infections and one deep infection. One fracture did not heal, and nine patients had substantial loss of reduction. Unilateral locked screw plating is a good alternative for treatment of problematic fractures of the tibial plateau that are associated with soft tissue damage and metaphyseal comminution. The reduction technique for exact alignment is demanding. Level of Evidence: Therapeutic Study, Level IV (case series). See Guidelines for Authors for a complete description of levels of evidence.
- 1 October 2005
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 439 (&NA;) , 207-214
Single Lateral Locked Screw Plating of Bicondylar Tibial Plateau Fractures
We prospectively followed a case series of 68 patients with 69 AO/ASIF 41-C-type fractures treated with the Less Invasive Stabilization System for the proximal lateral tibia. We assessed malreduction, secondary loss of reduction, and infection rates in patients with a locked screw plate for unilateral fixation of bicondylar fractures. Sixty-two (91%) patients returned for final followup (range, 11-13 months). Malreduction and malalignment were defined as an intraarticular step-off of 2 mm or greater, or as a malalignment in the frontal or sagittal plane greater than 5°. Fourteen fractures were open. Primary bone grafting was done in 13 patients. Significant malreduction was seen in 16 patients. There were four superficial infections and one deep infection. One fracture did not heal, and nine patients had substantial loss of reduction. Unilateral locked screw plating is a good alternative for treatment of problematic fractures of the tibial plateau that are associated with soft tissue damage and metaphyseal comminution. The reduction technique for exact alignment is demanding. Level of Evidence: Therapeutic Study, Level IV (case series). See Guidelines for Authors for a complete description of levels of evidence.
- 1 August 2005
- Published by Springer Nature in Der Chirurg
- Vol. 76 (8) , 789-794
Indikation zur Entfernung von Tibiamarknägeln
Die routinemäßige Entfernung von Tibiamarknägeln nach Frakturheilung war jahrelang empfohlen. Das Ziel dieser Studie war es, Empfehlungen zur Indikationsstellung für die Entfernung von Tibiamarknägeln zu erarbeiten. Es wurde eine retrospektive Analyse von 69 isolierten Implantatentfernungen nach Frakturheilung durchgeführt. Hierzu wurden Akten und Röntgenaufnahmen der Patienten untersucht. Als Follow-up erfolgte ein Telefoninterview bei 44 (64%) Patienten. Von den 26 Patienten, die vor der Operation Beschwerden hatten, gaben 19 (73%) eine Verbesserung der Symptomatik an. 11% (n=5) aller Patienten berichteten jedoch über eine Verschlechterung der Symptomatik durch die Operation. 3 Patienten (17%), die zuvor beschwerdefrei waren, hatten Beschwerden durch die Operation. In der vorliegenden Studie hatten weder die Nageltiefe noch der Gebrauch einer Verschlusskappe noch die Qualifikation des Operateurs noch das Intervall zwischen Nagelinsertion und Entfernung Einfluss auf die Operationszeit. Die routinemäßige Entfernung von Tibiamarknägeln bei asymptomatischen Patienten sollte kritisch mit diesen diskutiert werden. Tibial nail removal has been suggested as a routine procedure for both symptomatic and asymptomatic patients. The aim of this study was to define guidelines for the removal of tibial nails. A retrospective study on the isolated removal of 69 tibial nails after fracture consolidation was done. A review of the patient charts and radiographs was performed. Forty-four patients (64%) were available for the follow-up interview. Preoperatively, 26 patients (59%) had local complaints. Of these 26 patients, 73% reported an improvement, and 8% reported an aggravation of their local complaints. Of the 18 patients who were asymptomatic before surgery, 17% reported long-term complaints at follow-up. We conclude that routine removal of tibial nails should be discussed critically in asymptomatic patients.
- 1 August 2005
- Published by Springer Nature in Der Chirurg
- Vol. 76 (8) , 789-794
Indikation zur Entfernung von Tibiamarknägeln
Die routinemäßige Entfernung von Tibiamarknägeln nach Frakturheilung war jahrelang empfohlen. Das Ziel dieser Studie war es, Empfehlungen zur Indikationsstellung für die Entfernung von Tibiamarknägeln zu erarbeiten. Es wurde eine retrospektive Analyse von 69 isolierten Implantatentfernungen nach Frakturheilung durchgeführt. Hierzu wurden Akten und Röntgenaufnahmen der Patienten untersucht. Als Follow-up erfolgte ein Telefoninterview bei 44 (64%) Patienten. Von den 26 Patienten, die vor der Operation Beschwerden hatten, gaben 19 (73%) eine Verbesserung der Symptomatik an. 11% (n=5) aller Patienten berichteten jedoch über eine Verschlechterung der Symptomatik durch die Operation. 3 Patienten (17%), die zuvor beschwerdefrei waren, hatten Beschwerden durch die Operation. In der vorliegenden Studie hatten weder die Nageltiefe noch der Gebrauch einer Verschlusskappe noch die Qualifikation des Operateurs noch das Intervall zwischen Nagelinsertion und Entfernung Einfluss auf die Operationszeit. Die routinemäßige Entfernung von Tibiamarknägeln bei asymptomatischen Patienten sollte kritisch mit diesen diskutiert werden. Tibial nail removal has been suggested as a routine procedure for both symptomatic and asymptomatic patients. The aim of this study was to define guidelines for the removal of tibial nails. A retrospective study on the isolated removal of 69 tibial nails after fracture consolidation was done. A review of the patient charts and radiographs was performed. Forty-four patients (64%) were available for the follow-up interview. Preoperatively, 26 patients (59%) had local complaints. Of these 26 patients, 73% reported an improvement, and 8% reported an aggravation of their local complaints. Of the 18 patients who were asymptomatic before surgery, 17% reported long-term complaints at follow-up. We conclude that routine removal of tibial nails should be discussed critically in asymptomatic patients.
- 1 February 2005
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 43 (1) , 115-120
Robot-assisted fracture reduction: A preliminary study in the femur shaft
Reduction in femoral shaft fractures can be difficult to achieve with minimally invasive techniques. Malalignment and high intra-operative radiation exposure can result. The hypothesis was that robot-assisted fracture reduction could improve the quality of reduction while reducing the amount of radiation exposure. A robot system was developed that allows fracture manipulation with a joystick as input device. The system provides the surgeon with haptic and metric feedback. Fifteen synthetic femurs were broken and reduced by simulated open (group A) and closed techniques (group B). These techniques were compared with the robot-assisted reduction with (group C) and without (group D) haptic and metric information. An image intensifier was simulated with two orthogonal cameras. All reduction techniques showed minor malalignment. In group C, the alignment was: procurvatum/recurvatum 0.6° (0–2.0°); varus/valgus 0.8° (0–3.0°); and axial rotation 0.8° (0–3.1°). A significant difference was seen between the groups (two-way ANOVA, p<0.001). Axial rotation was significantly lower in group C than in group B (1.9°; p<0.001). The residual varus and valgus deviation was higher in group C compared with group A (0.4°, p=0.03). The median number of simulated radiographs was significantly less in group C (35) compared with group D (72; p<0.001) and group B (49; p=0.01). Robot-assisted fracture reduction of the femur provides high precision in alignment while reducing the amount of intraoperative imaging. Further research in this field is worthwhile.
- 1 February 2005
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 43 (1) , 115-120
Robot-assisted fracture reduction: A preliminary study in the femur shaft
Reduction in femoral shaft fractures can be difficult to achieve with minimally invasive techniques. Malalignment and high intra-operative radiation exposure can result. The hypothesis was that robot-assisted fracture reduction could improve the quality of reduction while reducing the amount of radiation exposure. A robot system was developed that allows fracture manipulation with a joystick as input device. The system provides the surgeon with haptic and metric feedback. Fifteen synthetic femurs were broken and reduced by simulated open (group A) and closed techniques (group B). These techniques were compared with the robot-assisted reduction with (group C) and without (group D) haptic and metric information. An image intensifier was simulated with two orthogonal cameras. All reduction techniques showed minor malalignment. In group C, the alignment was: procurvatum/recurvatum 0.6° (0–2.0°); varus/valgus 0.8° (0–3.0°); and axial rotation 0.8° (0–3.1°). A significant difference was seen between the groups (two-way ANOVA, p<0.001). Axial rotation was significantly lower in group C than in group B (1.9°; p<0.001). The residual varus and valgus deviation was higher in group C compared with group A (0.4°, p=0.03). The median number of simulated radiographs was significantly less in group C (35) compared with group D (72; p<0.001) and group B (49; p=0.01). Robot-assisted fracture reduction of the femur provides high precision in alignment while reducing the amount of intraoperative imaging. Further research in this field is worthwhile.