Christian Grünzweig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christian Grünzweig has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Jacopo Valsecchi
Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen, Switzerland
4 shared publications - Markus Strobl
PSI Center for Neutron and Muon Sciences, Villigen PSI, Switzerland
3 shared publications - Ralph P. Harti
Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen, Switzerland
3 shared publications - David Mannes
PSI Center for Neutron and Muon Sciences Paul Scherrer Institute Villigen Switzerland
2 shared publications J. Hovind
Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, Switzerland
2 shared publicationsM. Strobl
Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, Switzerland
2 shared publications
Latest Publications
- Open Access
- 22 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-7
3D sub-pixel correlation length imaging
Quantitative 2D neutron dark-field-imaging with neutron grating interferometry has been used to characterize structures in the size range below the imaging resolution. We present the first 3D quantitative neutron dark-field imaging experiment. We characterize sub-pixel structure sizes below the imaging resolution in tomography by quantitatively analyzing the change in dark-field contrast with varying neutron wavelength. This proof of principle experiment uses a dedicated reference sample with four different solutions of microspheres, each with a different diameter. The result is a 3D tomogram featuring a real space scattering function in each voxel. The presented experiment is expected to mark the path for future material science research through the individual quantification of small-angle scattering structures in each voxel of a volume of a bulk inhomogeneous sample material.
- 22 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-7
Open Access3D sub-pixel correlation length imaging
Quantitative 2D neutron dark-field-imaging with neutron grating interferometry has been used to characterize structures in the size range below the imaging resolution. We present the first 3D quantitative neutron dark-field imaging experiment. We characterize sub-pixel structure sizes below the imaging resolution in tomography by quantitatively analyzing the change in dark-field contrast with varying neutron wavelength. This proof of principle experiment uses a dedicated reference sample with four different solutions of microspheres, each with a different diameter. The result is a 3D tomogram featuring a real space scattering function in each voxel. The presented experiment is expected to mark the path for future material science research through the individual quantification of small-angle scattering structures in each voxel of a volume of a bulk inhomogeneous sample material.
- Open Access
- 22 August 2019
- Published by Springer Nature in Nature Communications
- Vol. 10 (1) , 1-9
Visualization and quantification of inhomogeneous and anisotropic magnetic fields by polarized neutron grating interferometry
The intrinsic magnetic moment of a neutron, combined with its charge neutrality, is a unique property which allows the investigation of magnetic phenomena in matter. Here we present how the utilization of a cold polarized neutron beam in neutron grating interferometry enables the visualization and characterization of magnetic properties on a microscopic scale in macroscopic samples. The measured signal originates from the phase shift induced by the magnetic potential. Our method enables the detection of previously inaccessible magnetic field gradients, in the order of T cm−1, extending the probed range by an order of magnitude. We visualize and quantify the phase shift induced by a well-defined square shaped uniaxial magnetic field and validate our experimental findings with theoretical calculations based on Hall probe measurements of the magnetic field distribution. This allows us to further extend our studies to investigations of inhomogeneous and anisotropic magnetic field distribution.
- 22 August 2019
- Published by Springer Nature in Nature Communications
- Vol. 10 (1) , 1-9
Open AccessVisualization and quantification of inhomogeneous and anisotropic magnetic fields by polarized neutron grating interferometry
The intrinsic magnetic moment of a neutron, combined with its charge neutrality, is a unique property which allows the investigation of magnetic phenomena in matter. Here we present how the utilization of a cold polarized neutron beam in neutron grating interferometry enables the visualization and characterization of magnetic properties on a microscopic scale in macroscopic samples. The measured signal originates from the phase shift induced by the magnetic potential. Our method enables the detection of previously inaccessible magnetic field gradients, in the order of T cm−1, extending the probed range by an order of magnitude. We visualize and quantify the phase shift induced by a well-defined square shaped uniaxial magnetic field and validate our experimental findings with theoretical calculations based on Hall probe measurements of the magnetic field distribution. This allows us to further extend our studies to investigations of inhomogeneous and anisotropic magnetic field distribution.
- Open Access
- 14 December 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 17845
Visualizing the heterogeneous breakdown of a fractal microstructure during compaction by neutron dark-field imaging
Structural properties of cohesive powders are dominated by their microstructural composition. Powders with a fractal microstructure show particularly interesting properties during compaction where a microstructural transition and a fractal breakdown happen before compaction and force transport. The study of this phenomenon has been challenging due to its long-range effect and the subsequent necessity to characterize these microstructural changes on a macroscopic scale. For the detailed investigation of the complex nature of powder compaction for various densification states along with the heterogeneous breakdown of the fractal microstructure we applied neutron dark-field imaging in combination with a variety of supporting techniques with various spatial resolutions, field-of-views and information depths. We used scanning electron microscopy to image the surface microstructure in a small field-of-view and X-ray tomography to image density variations in 3D with lower spatial resolution. Non-local spin-echo small-angle neutron scattering results are used to evaluate fitting models later used as input parameters for the neutron dark-field imaging data analysis. Finally, neutron dark-field imaging results in combination with supporting measurements using scanning electron microscopy, X-ray tomography and spin-echo small angle scattering allowed us to comprehensively study the heterogeneous transition from a fractal to a homogeneous microstructure of a cohesive powder in a quantitative manner.
- 14 December 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 17845
Open AccessVisualizing the heterogeneous breakdown of a fractal microstructure during compaction by neutron dark-field imaging
Structural properties of cohesive powders are dominated by their microstructural composition. Powders with a fractal microstructure show particularly interesting properties during compaction where a microstructural transition and a fractal breakdown happen before compaction and force transport. The study of this phenomenon has been challenging due to its long-range effect and the subsequent necessity to characterize these microstructural changes on a macroscopic scale. For the detailed investigation of the complex nature of powder compaction for various densification states along with the heterogeneous breakdown of the fractal microstructure we applied neutron dark-field imaging in combination with a variety of supporting techniques with various spatial resolutions, field-of-views and information depths. We used scanning electron microscopy to image the surface microstructure in a small field-of-view and X-ray tomography to image density variations in 3D with lower spatial resolution. Non-local spin-echo small-angle neutron scattering results are used to evaluate fitting models later used as input parameters for the neutron dark-field imaging data analysis. Finally, neutron dark-field imaging results in combination with supporting measurements using scanning electron microscopy, X-ray tomography and spin-echo small angle scattering allowed us to comprehensively study the heterogeneous transition from a fractal to a homogeneous microstructure of a cohesive powder in a quantitative manner.
- Open Access
- 25 October 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 15754
Dynamic volume magnetic domain wall imaging in grain oriented electrical steel at power frequencies with accumulative high-frame rate neutron dark-field imaging
The mobility of magnetic domains forms the link between the basic physical properties of a magnetic material and its global characteristics such as permeability and saturation field. Most commonly, surface domain structure are studied using magneto-optical Kerr microscopy. The limited information depth of approx. 20 nanometers, however, allows only for an indirect interpretation of the internal volume domain structures. Here we show how accumulative high-frame rate dynamic neutron dark-field imaging is able for the first time to visualize the dynamic of the volume magnetic domain structures in grain oriented electrical steel laminations at power frequencies. In particular we studied the volume domain structures with a spatial resolution of ∼100 μm and successfully quantified domain sizes, wall velocities, domain annihilation and its duration and domain wall multiplication in real time recordings at power frequencies of 10, 25 and 50 Hz with ±262.5 A/m and ±525 A/m (peak to peak) applied field.
- 25 October 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 15754
Open AccessDynamic volume magnetic domain wall imaging in grain oriented electrical steel at power frequencies with accumulative high-frame rate neutron dark-field imaging
The mobility of magnetic domains forms the link between the basic physical properties of a magnetic material and its global characteristics such as permeability and saturation field. Most commonly, surface domain structure are studied using magneto-optical Kerr microscopy. The limited information depth of approx. 20 nanometers, however, allows only for an indirect interpretation of the internal volume domain structures. Here we show how accumulative high-frame rate dynamic neutron dark-field imaging is able for the first time to visualize the dynamic of the volume magnetic domain structures in grain oriented electrical steel laminations at power frequencies. In particular we studied the volume domain structures with a spatial resolution of ∼100 μm and successfully quantified domain sizes, wall velocities, domain annihilation and its duration and domain wall multiplication in real time recordings at power frequencies of 10, 25 and 50 Hz with ±262.5 A/m and ±525 A/m (peak to peak) applied field.
- Open Access
- 1 March 2018
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 51 (2) , 386-394
A Monte Carlo approach for scattering correction towards quantitative neutron imaging of polycrystals
The development of neutron imaging from a qualitative inspection tool towards a quantitative technique in materials science has increased the requirements for accuracy significantly. Quantifying the thickness or the density of polycrystalline samples with high accuracy using neutron imaging has two main problems: (i) the scattering from the sample creates artefacts on the image and (ii) there is a lack of specific reference attenuation coefficients. This work presents experimental and simulation results to explain and approach these problems. Firstly, a series of neutron radiography and tomography experiments of iron, copper and vanadium are performed and serve as a reference. These materials were selected because they attenuate neutrons mainly through coherent (Fe and Cu) and incoherent (V) scattering. Secondly, an ad hoc Monte Carlo model was developed, based on beamline, sample and detector parameters, in order to simulate experiments, understand the physics involved and interpret the experimental data. The model, developed in the McStas framework, uses a priori information about the sample geometry and crystalline structure, as well as beamline settings, such as spectrum, geometry and detector type. The validity of the simulations is then verified with experimental results for the two problems that motivated this work: (i) the scattering distribution in transmission imaging and (ii) the calculated attenuation coefficients.
- 1 March 2018
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 51 (2) , 386-394
Open AccessA Monte Carlo approach for scattering correction towards quantitative neutron imaging of polycrystals
The development of neutron imaging from a qualitative inspection tool towards a quantitative technique in materials science has increased the requirements for accuracy significantly. Quantifying the thickness or the density of polycrystalline samples with high accuracy using neutron imaging has two main problems: (i) the scattering from the sample creates artefacts on the image and (ii) there is a lack of specific reference attenuation coefficients. This work presents experimental and simulation results to explain and approach these problems. Firstly, a series of neutron radiography and tomography experiments of iron, copper and vanadium are performed and serve as a reference. These materials were selected because they attenuate neutrons mainly through coherent (Fe and Cu) and incoherent (V) scattering. Secondly, an ad hoc Monte Carlo model was developed, based on beamline, sample and detector parameters, in order to simulate experiments, understand the physics involved and interpret the experimental data. The model, developed in the McStas framework, uses a priori information about the sample geometry and crystalline structure, as well as beamline settings, such as spectrum, geometry and detector type. The validity of the simulations is then verified with experimental results for the two problems that motivated this work: (i) the scattering distribution in transmission imaging and (ii) the calculated attenuation coefficients.
- Open Access
- 13 December 2017
- Published by MDPI AG in Journal of Imaging
- Vol. 3 (4) , 64
Small Angle Scattering in Neutron Imaging—A Review
Conventional neutron imaging utilizes the beam attenuation caused by scattering and absorption through the materials constituting an object in order to investigate its macroscopic inner structure. Small angle scattering has basically no impact on such images under the geometrical conditions applied. Nevertheless, in recent years different experimental methods have been developed in neutron imaging, which enable to not only generate contrast based on neutrons scattered to very small angles, but to map and quantify small angle scattering with the spatial resolution of neutron imaging. This enables neutron imaging to access length scales which are not directly resolved in real space and to investigate bulk structures and processes spanning multiple length scales from centimeters to tens of nanometers.
- 13 December 2017
- Published by MDPI AG in Journal of Imaging
- Vol. 3 (4) , 64
Open AccessSmall Angle Scattering in Neutron Imaging—A Review
Conventional neutron imaging utilizes the beam attenuation caused by scattering and absorption through the materials constituting an object in order to investigate its macroscopic inner structure. Small angle scattering has basically no impact on such images under the geometrical conditions applied. Nevertheless, in recent years different experimental methods have been developed in neutron imaging, which enable to not only generate contrast based on neutrons scattered to very small angles, but to map and quantify small angle scattering with the spatial resolution of neutron imaging. This enables neutron imaging to access length scales which are not directly resolved in real space and to investigate bulk structures and processes spanning multiple length scales from centimeters to tens of nanometers.
- Open Access
- 10 December 2017
- Published by MDPI AG in Journal of Imaging
- Vol. 3 (4) , 60
Performance of the Commercial PP/ZnS:Cu and PP/ZnS:Ag Scintillation Screens for Fast Neutron Imaging
Fast neutron imaging has a great potential as a nondestructive technique for testing large objects. The main factor limiting applications of this technique is detection technology, offering relatively poor spatial resolution of images and low detection efficiency, which results in very long exposure times. Therefore, research on development of scintillators for fast neutron imaging is of high importance. A comparison of the light output, gamma radiation sensitivity and spatial resolution of commercially available scintillator screens composed of PP/ZnS:Cu and PP/ZnS:Ag of different thicknesses are presented. The scintillators were provided by RC Tritec AG company and the test performed at the NECTAR facility located at the FRM II nuclear research reactor. It was shown that light output increases and the spatial resolution decreases with the scintillator thickness. Both compositions of the scintillating material provide similar light output, while the gamma sensitivity of PP/ZnS:Cu is significantly higher as compared to PP/ZnS:Ag-based scintillators. Moreover, we report which factors should be considered when choosing a scintillator and what are the limitations of the investigated types of scintillators.
- 10 December 2017
- Published by MDPI AG in Journal of Imaging
- Vol. 3 (4) , 60
Open AccessPerformance of the Commercial PP/ZnS:Cu and PP/ZnS:Ag Scintillation Screens for Fast Neutron Imaging
Fast neutron imaging has a great potential as a nondestructive technique for testing large objects. The main factor limiting applications of this technique is detection technology, offering relatively poor spatial resolution of images and low detection efficiency, which results in very long exposure times. Therefore, research on development of scintillators for fast neutron imaging is of high importance. A comparison of the light output, gamma radiation sensitivity and spatial resolution of commercially available scintillator screens composed of PP/ZnS:Cu and PP/ZnS:Ag of different thicknesses are presented. The scintillators were provided by RC Tritec AG company and the test performed at the NECTAR facility located at the FRM II nuclear research reactor. It was shown that light output increases and the spatial resolution decreases with the scintillator thickness. Both compositions of the scintillating material provide similar light output, while the gamma sensitivity of PP/ZnS:Cu is significantly higher as compared to PP/ZnS:Ag-based scintillators. Moreover, we report which factors should be considered when choosing a scintillator and what are the limitations of the investigated types of scintillators.
- 18 April 2016
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 70 (4) , 353-360
Real-Time Neutron Imaging to Detect Origin of Blocking in Drug Injection Devices
Non-destructive testing is a common method for root cause investigations of malfunction of mechanical devices, e.g. medical devices for drug dose delivery. Radiography is a method that has the advantage that it is possible to see through the sample. In this work we are using neutron radiography to observe drug distribution in drug injection devices during the injection process and as post injection examination. Using neutrons it is possible to show small amounts of liquid in capillaries and foam bubbles are shown with great contrast compared to metal and glass. The investigation has two parts optimized for high spatial and temporal resolution respectively. Using high spatial resolution it is possible to resolve the thin films of drug product in foam and even to detect the drug residues in the injection needle. Switching to high temporal resolution we demonstrate that it is possible to follow the injection process. Spatio-temporal data sets of the injection process were acquired using remotely triggered injection devices and a camera allowing sub-second frame rates. The motion analysis required the application of an edge preserving spatio-temporal denoising filter to improve the signal to noise ratio. After filtering it is possible to detect relevant edges and extract motion curves from the spatio-temporal data.
- 18 April 2016
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 70 (4) , 353-360
Real-Time Neutron Imaging to Detect Origin of Blocking in Drug Injection Devices
Non-destructive testing is a common method for root cause investigations of malfunction of mechanical devices, e.g. medical devices for drug dose delivery. Radiography is a method that has the advantage that it is possible to see through the sample. In this work we are using neutron radiography to observe drug distribution in drug injection devices during the injection process and as post injection examination. Using neutrons it is possible to show small amounts of liquid in capillaries and foam bubbles are shown with great contrast compared to metal and glass. The investigation has two parts optimized for high spatial and temporal resolution respectively. Using high spatial resolution it is possible to resolve the thin films of drug product in foam and even to detect the drug residues in the injection needle. Switching to high temporal resolution we demonstrate that it is possible to follow the injection process. Spatio-temporal data sets of the injection process were acquired using remotely triggered injection devices and a camera allowing sub-second frame rates. The motion analysis required the application of an edge preserving spatio-temporal denoising filter to improve the signal to noise ratio. After filtering it is possible to detect relevant edges and extract motion curves from the spatio-temporal data.
- Open Access
- 10 September 2015
- Published by Elsevier in Physics Procedia
- Vol. 69, 413-419
Determination of Bulk Magnetic Volume Properties by Neutron Dark-Field Imaging
- 10 September 2015
- Published by Elsevier in Physics Procedia
- Vol. 69, 413-419
Open AccessDetermination of Bulk Magnetic Volume Properties by Neutron Dark-Field Imaging
- 1 May 2007
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 78 (5) , 053708
Highly absorbing gadolinium test device to characterize the performance of neutron imaging detector systems
We report on the fabrication and application of a novel neutron imaging test device made of gadolinium. It is designed for a real time evaluation of the spatial resolution, resolution direction, and distortions of a neutron imaging detector system. Measurements of the spatial resolution of Li6F doped ZnS scintillator screens with different thicknesses and of imaging plates were performed. The obtained results are in good agreement with comparison measurements using the standard knife edge detection method.
- 1 May 2007
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 78 (5) , 053708
Highly absorbing gadolinium test device to characterize the performance of neutron imaging detector systems
We report on the fabrication and application of a novel neutron imaging test device made of gadolinium. It is designed for a real time evaluation of the spatial resolution, resolution direction, and distortions of a neutron imaging detector system. Measurements of the spatial resolution of Li6F doped ZnS scintillator screens with different thicknesses and of imaging plates were performed. The obtained results are in good agreement with comparison measurements using the standard knife edge detection method.