Grazia Maria Deriu has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Controlling Infectious Risk in Transfusion: Assessing the Effectiveness of Skin Disinfection in Blood Donors

    by Antonella Arghittu, Marco Dettori, Grazia Maria Deriu, Serena Soddu, Pietro Carmelo Manca, Anna Angela Carboni, Irene Collu, Alessandra Palmieri, Giovanna Deiana, Antonio Azara, et al.

    Bacterial infectious risk is a major problem in transfusion medicine. The type of micro-organisms isolated during bacterial contamination of blood products indicates that the donor’s skin is its main source. In this context, the primary measures to reduce this risk are: (a) optimal disinfection of the donor’s arm and (b) satellite bag diversion of the initial volume of blood collected. This work aimed to verify the effectiveness of skin disinfection of the blood donor’s venipuncture site. Two methodological approaches were used: (a) qualitative and quantitative microbiological testing of the skin at the collection site, before and post-disinfection; (b) qualitative microbiological testing of the first deviated blood. Pre-disinfection testing showed skin microbial load values between 3 and >200 CFU/plate. More than two-thirds of the isolates were Gram-positive bacteria (77.8%) of which 57.7% were staphylococci. Among Gram-negative bacteria, Pseudomonadaceae, Enterobacteriaceae, and Acinetobacter spp. were isolated from the blood donors (BDs). Post-disinfection, a 100% reduction in microbial load was observed in 84.4% of BDs. Microbiological testing of the first blood diverted sample revealed the presence of microbial flora in 1.9% samples; of the isolates, 83.3% were non-aureus staphylococci. This study highlights the importance of the correct application of skin disinfection procedures in order to ensure blood safety.


  • Open Access

    Ten-Year Evaluation of Thermal Comfort in Operating Rooms

    by Giovanna Deiana, Antonella Arghittu, Marco Dettori, Maria Grazia Deriu, Alessandra Palmieri, Antonio Azara, Paolo Castiglia, Maria Dolores Masia

    The microclimate is a particularly important environmental aspect in operating rooms (ORs), where more than in other hospital environments, it is extremely important, and at the same time extremely difficult, to reconcile the needs of different types of occupants (patients and operators). Moreover, unsuitable microclimatic conditions may affect the onset of infection. The present study aimed to analyze the periodic monitoring of the microclimatic conditions carried out in ORs over 10 years, to verify the adequacy of the thermal comfort conditions for all occupants. The evaluation of thermal comfort was carried out using the Fanger indices and the standards required by current legislation and specific guidelines. Non-compliant values for at least one parameter were found in 98.8% of the examinations performed in the ORs. A condition of thermal discomfort was calculated for 3.6% of healthcare professionals and 98.3% of patients. The monitoring of microclimatic conditions is particularly important in the OR as an indicator of inadequate functioning of the air conditioning system, which might affect the thermal comfort of all occupants and lead to microbial contamination of the room.


  • Open Access

    Environmental Surveillance of Legionella spp. in an Italian University Hospital Results of 10 Years of Analysis

    by Giovanna Deiana, Antonella Arghittu, Marco Dettori, Maria Dolores Masia, Maria Grazia Deriu, Andrea Piana, Maria Rosaria Muroni, Paolo Castiglia, Antonio Azara

    The occurrence of Legionella spp. in the water distribution systems of large hospitals and other healthcare facilities is considered particularly dangerous, due to the critical nature of the hospitalized patients. The aim of this study is to present a pluri-annual environmental surveillance in a large university hospital assessing the prevalence of Legionella spp. and underlining its variability over the years. The samples of water were collected in accordance with the Italian National Guidelines and the sampling sites considered in this study were selected favoring wards with very high-risk patients and with patients at increased risk. The laboratory analyzed a total of 305 water samples deriving from 24 different sampling points. Legionella spp. were detected in 39.4% of samples, the majority of which were contaminated by Legionella pneumophila serogroups 2–14 (68.7%). Statistically significant differences were found among different seasons with a linear trend in positive proportion from summer to spring. Several experimental interventions to prevent and reduce Legionella colonization were attempted, but there is no a definitive method for the complete eradication of this microorganism. The permanent monitoring of hospital water distribution systems is fundamental to preventing the potential risk of nosocomial Legionellosis and to implementing procedures to minimize the risk of Legionella spp. colonization.


  • Open Access

    ATP Bioluminescence for Assessing the Efficacy of the Manual Cleaning Procedure during the Reprocessing of Reusable Surgical Instruments

    by Maria Dolores Masia, Marco Dettori, Grazia Maria Deriu, Sabina Bellu, Lisa Arcadu, Antonio Azara, Andrea Piana, Alessandra Palmieri, Antonella Arghittu, Paolo Castiglia

    Achieving sterilization by adopting proper practices is essential to ensure that surgical instruments do not transmit microorganisms to patients. As the effectiveness of sterilization mandates effective cleaning, it is necessary to verify the success of cleaning procedures. In this study, we used the adenosine triphosphate (ATP) bioluminescence method for assessing the efficacy of the manual cleaning procedure during the reprocessing of reusable surgical instruments. The ATP bioluminescence assay was performed on 140 surgical instruments of 12 different types, both before being cleaned (baseline) and after each of the cleaning procedures (i.e., decontamination, manual washing, drying, and visual inspection). For each instrument, two swabs were used as follows: one to sample the entire surface (test point 1) and the other to sample the most difficult part of the surface to clean (test point 2). Overall, for each type of instrument, there was a decrease in contamination ranging from 99.6 to >99.9% (log reduction from 2.40 to 3.76). Thus, in order to standardize the assessment of cleanliness, it may be useful to introduce the bioluminescence method into the daily routine or, at least, at regular time intervals as a complementary check combined with visual inspection. This would allow real-time verification of the achievement of an adequate level of cleanliness.


  • Open Access

    Microbial Monitoring as a Tool for Preventing Infectious Risk in the Operating Room: Results of 10 Years of Activity

    by Maria Dolores Masia, Marco Dettori, Grazia Maria Deriu, Serena Soddu, Michela Deriu, Antonella Arghittu, Antonio Azara, Paolo Castiglia

    Environmental microbial contamination in the operating room (OR) can favour contamination of the surgical wound, posing the risk of infection of the surgical site. Thus, environmental monitoring is a useful tool for assessing environmental health and the effectiveness and efficiency of the measures adopted to control the risk of infection in the OR. This work aimed to analyse the long term environmental quality of 18 ORs throughout Sardinia, Italy, through the quantitative and qualitative characterisation of the microbial flora present in the air and on surfaces, in order to evaluate the trend over time, including in relation to any control measures adopted. The results of the sampling carried out in the period from January 2010 to December 2019 have been extrapolated from the archive-database of the Laboratory of the Hygiene and Control of Hospital Infections Unit of the University Hospital in Sassari. During the period in question, 188 air evaluations were carried out, both in empty rooms and during surgery, and 872 surface samples were taken. When the air was monitored, it emerged that significant contamination was detectable in a reduced number of examinations and a limited number of rooms. Microbial load values higher than the reference values may have been mainly determined by sub-optimal operation/maintenance of the air conditioning system. Surface testing showed a good level of sanitisation, given the low percentage of non-compliant values detected. The possibility of having data available on environmental quality is a useful educational and training tool both for those responsible for sanitisation procedures and the surgical team, in order to increase awareness of the effects of a lack of compliance with behavioural standards.


  • Open Access

    Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    by Maria Teresa Montagna, Osvalda De Giglio, Maria Luisa Cristina, Christian Napoli, Claudia Pacifico, Antonella Agodi, Tatjana Baldovin, Beatrice Casini, Maria Anna Coniglio, Marcello Mario D’errico, et al.

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.