Rizza Pua
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rizza Pua has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Seungryong Cho
Korea Advanced Institute of Science and Technology
3 shared publications Duchang Heo
Korea Electrotechnol Res Inst, Ansan 15588, South Korea
2 shared publicationsKee Hyun Kim
Korea Electrotechnol Res Inst, Ansan 15588, South Korea
2 shared publications- Leening P. Liu
University of Pennsylvania
2 shared publications - Nadav Shapira
University of Pennsylvania
2 shared publications - Peter Benjamin Noël
Department of Radiology Perelman School of Medicine University of Pennsylvania Philadelphia Pennsylvania USA
2 shared publications
Latest Publications
- Open Access
Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation
Objectives: Evaluate the reproducibility, temperature sensitivity, and radiation dose requirements of spectral CT thermometry in tissue-mimicking phantoms to establish its utility for non-invasive temperature monitoring of thermal ablations. Materials and Methods: Three liver mimicking phantoms embedded with temperature sensors were individually scanned with a dual-layer spectral CT at different radiation dose levels during heating and cooling (35 to 80 °C). Physical density maps were reconstructed from spectral results using a range of reconstruction parameters. Thermal volumetric expansion was then measured at each temperature sensor every 5°C in order to establish a correlation between physical density and temperature. Linear regressions were applied based on thermal volumetric expansion for each phantom, and coefficient of variation for fit parameters was calculated to characterize reproducibility of spectral CT thermometry. Additionally, temperature sensitivity was determined to evaluate the effect of acquisition parameters, reconstruction parameters, and image denoising. The resulting minimum radiation dose to meet the clinical temperature sensitivity requirement was determined for each slice thickness, both with and without additional denoising. Results: Thermal volumetric expansion was robustly replicated in all three phantoms, with a correlation coefficient variation of only 0.43%. Similarly, the coefficient of variation for the slope and intercept were 9.6% and 0.08%, respectively, indicating reproducibility of the spectral CT thermometry. Temperature sensitivity ranged from 2 to 23 °C, decreasing with increased radiation dose, slice thickness, and iterative reconstruction level. To meet the clinical requirement for temperature sensitivity, the minimum required radiation dose ranged from 20, 30, and 57 mGy for slice thickness of 2, 3, and 5 mm, respectively, but was reduced to 2 mGy with additional denoising. Conclusions: Spectral CT thermometry demonstrated reproducibility across three liver-mimicking phantoms and illustrated the clinical requirement for temperature sensitivity can be met for different slice thicknesses. Moreover, additional denoising enables the use of more clinically relevant radiation doses, facilitating the clinical translation of spectral CT thermometry. The reproducibility and temperature accuracy of spectral CT thermometry enable its clinical application for non-invasive temperature monitoring of thermal ablation.
Open AccessReproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation
Objectives: Evaluate the reproducibility, temperature sensitivity, and radiation dose requirements of spectral CT thermometry in tissue-mimicking phantoms to establish its utility for non-invasive temperature monitoring of thermal ablations. Materials and Methods: Three liver mimicking phantoms embedded with temperature sensors were individually scanned with a dual-layer spectral CT at different radiation dose levels during heating and cooling (35 to 80 °C). Physical density maps were reconstructed from spectral results using a range of reconstruction parameters. Thermal volumetric expansion was then measured at each temperature sensor every 5°C in order to establish a correlation between physical density and temperature. Linear regressions were applied based on thermal volumetric expansion for each phantom, and coefficient of variation for fit parameters was calculated to characterize reproducibility of spectral CT thermometry. Additionally, temperature sensitivity was determined to evaluate the effect of acquisition parameters, reconstruction parameters, and image denoising. The resulting minimum radiation dose to meet the clinical temperature sensitivity requirement was determined for each slice thickness, both with and without additional denoising. Results: Thermal volumetric expansion was robustly replicated in all three phantoms, with a correlation coefficient variation of only 0.43%. Similarly, the coefficient of variation for the slope and intercept were 9.6% and 0.08%, respectively, indicating reproducibility of the spectral CT thermometry. Temperature sensitivity ranged from 2 to 23 °C, decreasing with increased radiation dose, slice thickness, and iterative reconstruction level. To meet the clinical requirement for temperature sensitivity, the minimum required radiation dose ranged from 20, 30, and 57 mGy for slice thickness of 2, 3, and 5 mm, respectively, but was reduced to 2 mGy with additional denoising. Conclusions: Spectral CT thermometry demonstrated reproducibility across three liver-mimicking phantoms and illustrated the clinical requirement for temperature sensitivity can be met for different slice thicknesses. Moreover, additional denoising enables the use of more clinically relevant radiation doses, facilitating the clinical translation of spectral CT thermometry. The reproducibility and temperature accuracy of spectral CT thermometry enable its clinical application for non-invasive temperature monitoring of thermal ablation.
- Open Access
Impact of patient habitus and acquisition protocol on iodine quantification in dual source photon-counting CT
Objective Evaluation of iodine quantification accuracy with varying iterative reconstruction level, patient habitus, and acquisition mode on a first-generation dual-source photon-counting computed tomography (PCCT) system. Methods A multi-energy CT phantom (20 cm diameter/small) was imaged with and without an extension ring (30 by 40 cm/large). It was equipped with various iodine inserts (0.2, 0.5, 1.0, 2.0, 5.0, 10.0, 15.0 mg/ml) and scanned over a range of radiation dose levels (CTDIvol 0.5, 0.8, 1.2, 1.6, 2.0, 4.0, 6.0, 10.0, 15.0 mGy) using four different acquisition modes: single source 120 kVp (SS120), 140 kVp (SS140) and dual-source 120 kVp (DS120), 140 kVp (DS140). Iodine density maps were produced with different levels of iterative reconstruction (QIR 0, 2, 4). To assess the agreement between nominal and measured iodine concentrations, root mean square error (RMSE) and Bland-Altman plots were generated by grouping different radiation dose levels (ultra-low: < 1.5 mGy; low: 1.5 – 5 mGy; medium: 5 – 15 mGy) and iodine concentrations (low: < 5 mg/ml; high: 5 – 15 mg/ml). Results Overall, quantification of iodine concentrations was accurate and reliable even at ultra-low radiation dose levels. With low and high iodine concentrations, RMSE ranged from 0.25 to 0.37, 0.20 to 0.38, and 0.25 to 0.37 mg/ml for ultra-low, low, and medium radiation dose levels, respectively. Similarly, for the three acquisition modes (SS120, SS140, DS 120, DS140), RMSE was stable at 0.31, 0.28, 0.33 and 0.30 mg/ml, respectively. Considering all levels of radiation dose, acquisition mode, and iodine concentration, the accuracy of iodine quantification was higher for the phantom without extension ring (RMSE 0.21 mg/ml) and did not vary across different levels of iterative reconstruction. Conclusions The first-generation PCCT allows for accurate iodine quantification over a wide range of iodine concentrations and radiation dose levels. Even very small concentrations of iodine can be quantified accurately at different simulated patient sizes. Stable accuracy across iterative reconstruction levels may allow further radiation exposure reductions without affecting quantitative results. Summary Clinical photon-counting CT provides excellent iodine quantification performance for a wide range of parameters (patient habitus, acquisition parameters, and iterative reconstruction modes) due to its excellent ultra-low dose performance. Key Results First-generation PCCTs are capable of accurately quantifying iodine over a wide range of radiation dose levels and iodine concentrations. Further radiation exposure reductions may be possible given stable accuracy across iterative reconstruction levels. In the future, accurate and precise iodine quantification will allow for the development of spectral-based biomarkers.
Open AccessImpact of patient habitus and acquisition protocol on iodine quantification in dual source photon-counting CT
Objective Evaluation of iodine quantification accuracy with varying iterative reconstruction level, patient habitus, and acquisition mode on a first-generation dual-source photon-counting computed tomography (PCCT) system. Methods A multi-energy CT phantom (20 cm diameter/small) was imaged with and without an extension ring (30 by 40 cm/large). It was equipped with various iodine inserts (0.2, 0.5, 1.0, 2.0, 5.0, 10.0, 15.0 mg/ml) and scanned over a range of radiation dose levels (CTDIvol 0.5, 0.8, 1.2, 1.6, 2.0, 4.0, 6.0, 10.0, 15.0 mGy) using four different acquisition modes: single source 120 kVp (SS120), 140 kVp (SS140) and dual-source 120 kVp (DS120), 140 kVp (DS140). Iodine density maps were produced with different levels of iterative reconstruction (QIR 0, 2, 4). To assess the agreement between nominal and measured iodine concentrations, root mean square error (RMSE) and Bland-Altman plots were generated by grouping different radiation dose levels (ultra-low: < 1.5 mGy; low: 1.5 – 5 mGy; medium: 5 – 15 mGy) and iodine concentrations (low: < 5 mg/ml; high: 5 – 15 mg/ml). Results Overall, quantification of iodine concentrations was accurate and reliable even at ultra-low radiation dose levels. With low and high iodine concentrations, RMSE ranged from 0.25 to 0.37, 0.20 to 0.38, and 0.25 to 0.37 mg/ml for ultra-low, low, and medium radiation dose levels, respectively. Similarly, for the three acquisition modes (SS120, SS140, DS 120, DS140), RMSE was stable at 0.31, 0.28, 0.33 and 0.30 mg/ml, respectively. Considering all levels of radiation dose, acquisition mode, and iodine concentration, the accuracy of iodine quantification was higher for the phantom without extension ring (RMSE 0.21 mg/ml) and did not vary across different levels of iterative reconstruction. Conclusions The first-generation PCCT allows for accurate iodine quantification over a wide range of iodine concentrations and radiation dose levels. Even very small concentrations of iodine can be quantified accurately at different simulated patient sizes. Stable accuracy across iterative reconstruction levels may allow further radiation exposure reductions without affecting quantitative results. Summary Clinical photon-counting CT provides excellent iodine quantification performance for a wide range of parameters (patient habitus, acquisition parameters, and iterative reconstruction modes) due to its excellent ultra-low dose performance. Key Results First-generation PCCTs are capable of accurately quantifying iodine over a wide range of radiation dose levels and iodine concentrations. Further radiation exposure reductions may be possible given stable accuracy across iterative reconstruction levels. In the future, accurate and precise iodine quantification will allow for the development of spectral-based biomarkers.
- 20 April 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11792, 117920T-9
A feasibility study of metal artifacts reduction using weighted iterative reconstruction algorithm for frequency split metal artifact reduction
The sinogram inpainting based methods such as normalized metal artifact reduction (NMAR) shows good performance in reducing the metal artifacts. However, these methods wipe away the structures near the metal which are severely corrupted by artifacts. The proposed method using a weight to lower metal corrupted pixels during the iteration instead of using an inpainting method to conserve the structures. Then, the proposed method was complementarily used with NMAR to generate a corrected image using the frequency split method. The titanium inserted XCAT phantoms were simulated from the 80kVp of energy. The metals were segmented from the filtered backprojection image using the threshold from the projection data. Afterwards, they were projected to acquire the metal sinogram index and the metal subtracted projection data. A weight map is generated from the scale factor and the log of the original raw data which has the metal index. The metal subtracted projection data were iteratively reconstructed. During the iteration, the step size of the update term was affected by a weight map, and the contributions of the metal present sinogram were lowered. Finally, using the frequency split approach, the corrected image was generated from the proposed and NMAR results. It was possible to lower the artifacts while conserving the structures in the proposed method. This work indicates the weighted iterative reconstruction can be complementarily used with the existing FSMAR approach.
- 20 April 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11792, 117920T-9
A feasibility study of metal artifacts reduction using weighted iterative reconstruction algorithm for frequency split metal artifact reduction
The sinogram inpainting based methods such as normalized metal artifact reduction (NMAR) shows good performance in reducing the metal artifacts. However, these methods wipe away the structures near the metal which are severely corrupted by artifacts. The proposed method using a weight to lower metal corrupted pixels during the iteration instead of using an inpainting method to conserve the structures. Then, the proposed method was complementarily used with NMAR to generate a corrected image using the frequency split method. The titanium inserted XCAT phantoms were simulated from the 80kVp of energy. The metals were segmented from the filtered backprojection image using the threshold from the projection data. Afterwards, they were projected to acquire the metal sinogram index and the metal subtracted projection data. A weight map is generated from the scale factor and the log of the original raw data which has the metal index. The metal subtracted projection data were iteratively reconstructed. During the iteration, the step size of the update term was affected by a weight map, and the contributions of the metal present sinogram were lowered. Finally, using the frequency split approach, the corrected image was generated from the proposed and NMAR results. It was possible to lower the artifacts while conserving the structures in the proposed method. This work indicates the weighted iterative reconstruction can be complementarily used with the existing FSMAR approach.
- 14 October 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (30) , 9328-9339
Data-specific mask-guided image reconstruction for diffuse optical tomography
Conventional approaches in diffuse optical tomography (DOT) image reconstruction often address the ill-posed inverse problem via regularization with a constant penalty parameter, which uniformly smooths out the solution. In this study, we present a data-specific mask-guided scheme that incorporates a prior mask constraint into the image reconstruction framework. The prior mask was created from the DOT data itself by exploiting the multi-measurement vector formulation. We accordingly propose two methods to integrate the prior mask into the reconstruction process. First, as a soft prior by exploiting a spatially varying regularization. Second, as a hard prior by imposing a region-of-interest-limited reconstruction. Furthermore, the latter method iterates between discrete and continuous steps to update the mask and optical parameters, respectively. The proposed methods showed enhanced optical contrast accuracy, improved spatial resolution, and reduced noise level in DOT reconstructed images compared with the conventional approaches such as the modified Levenberg–Marquardt approach and the l 1 -regularization based sparse recovery approach.
- 14 October 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (30) , 9328-9339
Data-specific mask-guided image reconstruction for diffuse optical tomography
Conventional approaches in diffuse optical tomography (DOT) image reconstruction often address the ill-posed inverse problem via regularization with a constant penalty parameter, which uniformly smooths out the solution. In this study, we present a data-specific mask-guided scheme that incorporates a prior mask constraint into the image reconstruction framework. The prior mask was created from the DOT data itself by exploiting the multi-measurement vector formulation. We accordingly propose two methods to integrate the prior mask into the reconstruction process. First, as a soft prior by exploiting a spatially varying regularization. Second, as a hard prior by imposing a region-of-interest-limited reconstruction. Furthermore, the latter method iterates between discrete and continuous steps to update the mask and optical parameters, respectively. The proposed methods showed enhanced optical contrast accuracy, improved spatial resolution, and reduced noise level in DOT reconstructed images compared with the conventional approaches such as the modified Levenberg–Marquardt approach and the l 1 -regularization based sparse recovery approach.
- 10 February 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (5) , 1461-1470
Convolutional neural network-based approach to estimate bulk optical properties in diffuse optical tomography
Deep learning has been actively investigated for various applications such as image classification, computer vision, and regression tasks, and it has shown state-of-the-art performance. In diffuse optical tomography (DOT), the accurate estimation of the bulk optical properties of a medium is paramount because it directly affects the overall image quality. In this work, we exploit deep learning to propose a novel, to the best of our knowledge, convolutional neural network (CNN)-based approach to estimate the bulk optical properties of a highly scattering medium such as biological tissue in DOT. We validated the proposed method by using experimental, as well as, simulated data. For performance assessment, we compared the results of the proposed method with those of existing approaches. The results demonstrate that the proposed CNN-based approach for bulk optical property estimation outperforms existing methods in terms of estimation accuracy, with lower computation time.
- 10 February 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (5) , 1461-1470
Convolutional neural network-based approach to estimate bulk optical properties in diffuse optical tomography
Deep learning has been actively investigated for various applications such as image classification, computer vision, and regression tasks, and it has shown state-of-the-art performance. In diffuse optical tomography (DOT), the accurate estimation of the bulk optical properties of a medium is paramount because it directly affects the overall image quality. In this work, we exploit deep learning to propose a novel, to the best of our knowledge, convolutional neural network (CNN)-based approach to estimate the bulk optical properties of a highly scattering medium such as biological tissue in DOT. We validated the proposed method by using experimental, as well as, simulated data. For performance assessment, we compared the results of the proposed method with those of existing approaches. The results demonstrate that the proposed CNN-based approach for bulk optical property estimation outperforms existing methods in terms of estimation accuracy, with lower computation time.