Martin Kober
Martin Kober has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Frank Rinderknecht
German Aerospace Center (DLR), Institute of Vehicle Concepts, 70569 Stuttgart, Germany
3 shared publications - Julian Schwab
German Aerospace Center (DLR), Institute of Vehicle Concepts, 70569 Stuttgart, Germany
2 shared publications - Lars Heber
DLR Institut für Fahrzeugkonzepte
2 shared publications - Oliver Schauerte
Volkswagen AG
2 shared publications - Tjark Siefkes
Institute of Vehicle Concepts, German Aerospace Center (DLR), Pfaffenwaldring 38-40, 70569 Stuttgart, Germany
2 shared publications Aina Rossello
German Aerospace Center (DLR), Institute of Vehicle Concepts, Stuttgart, Germany
1 shared publication
Latest Publications
- 14 September 2024
- Published by Springer Nature
- p. 497-614
Bauweisen des Antriebsstranges
- 14 September 2024
- Published by Springer Nature
- p. 337-442
Bauweisen der Karosserie
- Open Access
Experimental Analysis of the Long-Term Stability of Thermoelectric Generators under Thermal Cycling in Air and Argon Atmosphere
It is estimated that 72% of the worldwide primary energy consumption is lost as waste heat. Thermoelectric Generators (TEGs) are a possible solution to convert a part of this energy into electricity and heat for space heating. However, for their deployment a proven long-term operation is required. Therefore, this research investigates the long-term stability of TEGs on system level in air and argon atmosphere under thermal cycling up to 543 K. The layout of the examined test objects resembles a TEG in stack design. The results show that the maximal output power of the test object in air reaches a plateau at 57% of the initial power after 50 cycles caused by an increased electrical resistance of the system. Whereas the test object in argon atmosphere shows no significant degradation of electrical power or resistance. The findings represent a step towards the understanding of the long-term stability of TEGs and can be used as a guideline for design decisions.
Open AccessExperimental Analysis of the Long-Term Stability of Thermoelectric Generators under Thermal Cycling in Air and Argon Atmosphere
It is estimated that 72% of the worldwide primary energy consumption is lost as waste heat. Thermoelectric Generators (TEGs) are a possible solution to convert a part of this energy into electricity and heat for space heating. However, for their deployment a proven long-term operation is required. Therefore, this research investigates the long-term stability of TEGs on system level in air and argon atmosphere under thermal cycling up to 543 K. The layout of the examined test objects resembles a TEG in stack design. The results show that the maximal output power of the test object in air reaches a plateau at 57% of the initial power after 50 cycles caused by an increased electrical resistance of the system. Whereas the test object in argon atmosphere shows no significant degradation of electrical power or resistance. The findings represent a step towards the understanding of the long-term stability of TEGs and can be used as a guideline for design decisions.
- Open Access
Exergy Analysis of the Prevailing Residential Heating System and Derivation of Future CO2-Reduction Potential
The residential heating sector accounts for a large share of the worldwide annual primary energy consumption. In order to reduce CO2-emissions, it is therefore particularly important to analyse this sector for potential efficiency improvements. In Europe, natural gas boilers are the most widely used heating technology since they are cost-effective and can be installed in any type of building. The energy efficiency of these boilers is already high. However, in their internal process, heat is generated at a high temperature level which is only used for space heating and therefore a high amount of exergy remains unused. This research aims to develop the potential of using the exergy to further improve the efficiency of the systems. A novel combination of methods is applied to analyse the thermodynamic behaviour of gas-fired boilers in detail and over the cycle of a year. The analysis is performed in two steps: In the first step a system is examined in stationary operating points. This is carried out through an experimental setup and a three-dimensional numerical simulation. In the second step, the obtained data is applied to a transient annual building simulation. The results show the temporal distribution and total amount of the annual exergy loss for a common residential building. The exergy loss accumulates to 16,271 kWh per year, which shows the high potential to partially convert the exergy to electrical energy and significantly reduce the external electricity demand and CO2-emissions of the building. Based on this, new technologies such as Thermoelectric Generators can be developed, which can enable this potential.
Open AccessExergy Analysis of the Prevailing Residential Heating System and Derivation of Future CO2-Reduction Potential
The residential heating sector accounts for a large share of the worldwide annual primary energy consumption. In order to reduce CO2-emissions, it is therefore particularly important to analyse this sector for potential efficiency improvements. In Europe, natural gas boilers are the most widely used heating technology since they are cost-effective and can be installed in any type of building. The energy efficiency of these boilers is already high. However, in their internal process, heat is generated at a high temperature level which is only used for space heating and therefore a high amount of exergy remains unused. This research aims to develop the potential of using the exergy to further improve the efficiency of the systems. A novel combination of methods is applied to analyse the thermodynamic behaviour of gas-fired boilers in detail and over the cycle of a year. The analysis is performed in two steps: In the first step a system is examined in stationary operating points. This is carried out through an experimental setup and a three-dimensional numerical simulation. In the second step, the obtained data is applied to a transient annual building simulation. The results show the temporal distribution and total amount of the annual exergy loss for a common residential building. The exergy loss accumulates to 16,271 kWh per year, which shows the high potential to partially convert the exergy to electrical energy and significantly reduce the external electricity demand and CO2-emissions of the building. Based on this, new technologies such as Thermoelectric Generators can be developed, which can enable this potential.
- Open Access
- 13 February 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (5) , 2928-2936
The High Potential for Waste Heat Recovery in Hybrid Vehicles: A Comparison Between the Potential in Conventional and Hybrid Powertrains
In future mobility, the mix of different drive trains will probably be much more diverse than it is today. According to a large number of scenario analyses, a predominant number of vehicles will continue to be based on the internal combustion engine (ICE), while an increasing number of hybrid vehicles are expected. To achieve the required reductions in CO2 emissions it is necessary to investigate all potential technologies for efficiency improvement. Therefore in this work the potential of waste heat recovery is examined for conventional and hybrid vehicles. Due to the fact that in an internal combustion engine approximately 2/3 of the fuel's chemical energy dissipates as waste heat, the potential for the recovery of this energy in all ICE driven powertrains is, in principle, high. The results of this work show that in hybrid vehicles the highest share of the energy supplied by the fuel is lost in the exhaust gas. In order to further elaborate this result, we conduct an exemplary examination of two comparable vehicles of the compact class within the worldwide harmonized light duty test cycle. Measurement data from the two vehicles at the roller dynamometer is used. The result shows that the averaged exhaust gas heat flow of the conventional vehicle is 5.0 kW. For the hybrid vehicle, driving in the charge sustaining mode, the averaged exhaust gas heat flow results in 8.1 kW. The comparison shows that the temperature level of this exhaust gas is even higher than that of the conventional vehicle. In addition, this work shows that through the higher temperatures, the exergy in the exhaust gas is higher in hybrid vehicles even if the combustion engine works with a higher efficiency. In the exemplary comparison the averaged exergy of the exhaust gas is 3.2 kW for the conventional and 5.7 kW for the hybrid vehicle. As a result of this work, the high potential for waste heat recovery in hybrid vehicles could be demonstrated.
- 13 February 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (5) , 2928-2936
Open AccessThe High Potential for Waste Heat Recovery in Hybrid Vehicles: A Comparison Between the Potential in Conventional and Hybrid Powertrains
In future mobility, the mix of different drive trains will probably be much more diverse than it is today. According to a large number of scenario analyses, a predominant number of vehicles will continue to be based on the internal combustion engine (ICE), while an increasing number of hybrid vehicles are expected. To achieve the required reductions in CO2 emissions it is necessary to investigate all potential technologies for efficiency improvement. Therefore in this work the potential of waste heat recovery is examined for conventional and hybrid vehicles. Due to the fact that in an internal combustion engine approximately 2/3 of the fuel's chemical energy dissipates as waste heat, the potential for the recovery of this energy in all ICE driven powertrains is, in principle, high. The results of this work show that in hybrid vehicles the highest share of the energy supplied by the fuel is lost in the exhaust gas. In order to further elaborate this result, we conduct an exemplary examination of two comparable vehicles of the compact class within the worldwide harmonized light duty test cycle. Measurement data from the two vehicles at the roller dynamometer is used. The result shows that the averaged exhaust gas heat flow of the conventional vehicle is 5.0 kW. For the hybrid vehicle, driving in the charge sustaining mode, the averaged exhaust gas heat flow results in 8.1 kW. The comparison shows that the temperature level of this exhaust gas is even higher than that of the conventional vehicle. In addition, this work shows that through the higher temperatures, the exergy in the exhaust gas is higher in hybrid vehicles even if the combustion engine works with a higher efficiency. In the exemplary comparison the averaged exergy of the exhaust gas is 3.2 kW for the conventional and 5.7 kW for the hybrid vehicle. As a result of this work, the high potential for waste heat recovery in hybrid vehicles could be demonstrated.
- Open Access
- 7 February 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (5) , 2910-2919
Holistic Development of Thermoelectric Generators for Automotive Applications
One of the major challenges of the future automotive development is to achieve the required reductions of the CO2emissions. Therefore, it is necessary to investigate all potential technologies for efficiency improvement. In a combustion engine, about 2/3 of the chemical energy of the fuel is dissipated as waste heat. Due to its high temperature level, the waste heat in the exhaust gas is very promising for the technology of thermoelectric generators (TEG). In this work the methodology for a holistic TEG optimization for automotive vehicle applications will be presented. Thereby, all system interactions between the vehicle and the TEG are modelled and the CO2reduction can be optimized within the vehicle system. Moreover the costs are calculated for each TEG design, and the method realizes an optimization of the cost–benefit ratio in a direct way. The optimization method is applied with a highly integrated TEG design, which has been developed to be compact and lightweight. Through the combination of improvements in TEG design and system optimization, a gravimetric power density of 267 W/kg and a volumetric power density of 478 W/dm^3 could be achieved. These power densities are about 900% and 700%, respectively, higher than the state of the art. The optimization method was applied exemplarily to a conventional vehicle (Volkswagen Golf VII) and a hybrid vehicle (Opel Ampera/Chevrolet Volt). As a result, reductions in consumption and CO2emissions of up to 2.2% for the conventional and 3.4% for the hybrid vehicle could be achieved within the worldwide harmonized light duty driving test cycle. The cost–benefit optimum is 81.3 €/(g/km) for the conventional vehicle and 54.8 €/(g/km) for the hybrid vehicle in charge sustaining mode.
- 7 February 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (5) , 2910-2919
Open AccessHolistic Development of Thermoelectric Generators for Automotive Applications
One of the major challenges of the future automotive development is to achieve the required reductions of the CO2emissions. Therefore, it is necessary to investigate all potential technologies for efficiency improvement. In a combustion engine, about 2/3 of the chemical energy of the fuel is dissipated as waste heat. Due to its high temperature level, the waste heat in the exhaust gas is very promising for the technology of thermoelectric generators (TEG). In this work the methodology for a holistic TEG optimization for automotive vehicle applications will be presented. Thereby, all system interactions between the vehicle and the TEG are modelled and the CO2reduction can be optimized within the vehicle system. Moreover the costs are calculated for each TEG design, and the method realizes an optimization of the cost–benefit ratio in a direct way. The optimization method is applied with a highly integrated TEG design, which has been developed to be compact and lightweight. Through the combination of improvements in TEG design and system optimization, a gravimetric power density of 267 W/kg and a volumetric power density of 478 W/dm^3 could be achieved. These power densities are about 900% and 700%, respectively, higher than the state of the art. The optimization method was applied exemplarily to a conventional vehicle (Volkswagen Golf VII) and a hybrid vehicle (Opel Ampera/Chevrolet Volt). As a result, reductions in consumption and CO2emissions of up to 2.2% for the conventional and 3.4% for the hybrid vehicle could be achieved within the worldwide harmonized light duty driving test cycle. The cost–benefit optimum is 81.3 €/(g/km) for the conventional vehicle and 54.8 €/(g/km) for the hybrid vehicle in charge sustaining mode.
- Open Access
- 5 February 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (5) , 2902-2909
Thermoelectric Generators for Automotive Applications: Holistic Optimization and Validation by a Functional Prototype
Current research has led to a significant improvement at the system level of thermoelectric generators (TEG) for automotive applications. The previously low power density could be increased considerably up to 267 W/kg and 478 W/dm3. In addition, the cost–benefit ratio of the technology in the overall system of the vehicle was improved through intensive optimizations on system level. The results presented so far are based on measurement data of single thermoelectric modules (TEM) and simulation of the TEG system. In this paper the high simulative increases at the system level, achieved through a holistic optimization method, are validated by a functional prototype, completely equipped with TEM. Thereby, a functional prototype has been developed and built successfully and measured on a hot gas test bench. In the experiment all TEM show a stable power output and the highest gravimetric power density of automotive TEG systems known to the authors could be measured. Further tests will be performed with the functional prototype as described in the outlook. In addition to the successful tests, the simulation is validated with the detailed measurement data. After adapting the measurement method of the TEM for providing more accurate TEM measurement data as input for the simulation, a suitable match could be achieved between the TEG simulation and the experiment. In the measurement points performed so far, the accuracy of the simulated temperatures reaches more than 95%. The accuracy of the simulated output power is more than 97%.
- 5 February 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (5) , 2902-2909
Open AccessThermoelectric Generators for Automotive Applications: Holistic Optimization and Validation by a Functional Prototype
Current research has led to a significant improvement at the system level of thermoelectric generators (TEG) for automotive applications. The previously low power density could be increased considerably up to 267 W/kg and 478 W/dm3. In addition, the cost–benefit ratio of the technology in the overall system of the vehicle was improved through intensive optimizations on system level. The results presented so far are based on measurement data of single thermoelectric modules (TEM) and simulation of the TEG system. In this paper the high simulative increases at the system level, achieved through a holistic optimization method, are validated by a functional prototype, completely equipped with TEM. Thereby, a functional prototype has been developed and built successfully and measured on a hot gas test bench. In the experiment all TEM show a stable power output and the highest gravimetric power density of automotive TEG systems known to the authors could be measured. Further tests will be performed with the functional prototype as described in the outlook. In addition to the successful tests, the simulation is validated with the detailed measurement data. After adapting the measurement method of the TEM for providing more accurate TEM measurement data as input for the simulation, a suitable match could be achieved between the TEG simulation and the experiment. In the measurement points performed so far, the accuracy of the simulated temperatures reaches more than 95%. The accuracy of the simulated output power is more than 97%.