Yoshiyuki Shimizu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yoshiyuki Shimizu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Kazuya Tachibana
Department of Anesthesiology, Osaka Prefectural Hospital Organization, Osaka Women's and Children's Hospital, 840 Murodo-cho, Izumi, Osaka 594-1101, Japan
2 shared publications - Hirofumi Hamaba
Department of Anesthesiology, Osaka Prefectural Hospital Organization, Osaka Women's and Children's Hospital, Izumi, Osaka, Japan
1 shared publication - Jun Takeshita
Department of Anesthesiology, Osaka Prefectural Hospital Organization, Osaka Women’s and Children’s Hospital, Izumi, Japan
1 shared publication - Kazue Moon
Department of Critical Care, Osaka Women's and Children's Hospital, 840, Murodo-cho, Izumi, Osaka, Japan
1 shared publication - Muneyuki Takeuchi
Department of Critical Care, Osaka Women's and Children's Hospital, 840, Murodo-cho, Izumi, Osaka, Japan
1 shared publication - Takeshi Hatachi
Department of Critical Care, Osaka Women's and Children's Hospital, 840, Murodo-cho, Izumi, Osaka, Japan
1 shared publication
Latest Publications
- Open Access
- 22 October 2018
- Published by Springer Nature in JA Clinical Reports
- Vol. 4 (1) , 1-4
Predicting extubation readiness by monitoring the electrical activity of the diaphragm after prolonged mechanical ventilation: a pediatric case report
The intensity of the electrical activity of the diaphragm (Edi) correlates with inspiratory effort. The ratio of tidal volume to the Edi is known as neuroventilatory efficiency (NVE) and is used as an index for ventilation efficiency. Here, we present a case showing that Edi and NVE may be effective parameters to predict successful extubation. A 6-month-old female infant required prolonged mechanical ventilation after cardiac surgery. Fifty-two days after surgery, her trachea was extubated but required reintubation. Edi monitoring was initiated to assess diaphragm function. The Edi was > 70 mcV just after the reintubation, and her NVE was 1.0 mL/mcV, but gradually decreased. On day 59, her Edi values during the spontaneous breathing trials were 13 mcV with the improvement of NVE (2.5 mL/mcV) and her trachea was extubated without complications. The Edi and NVE were valuable for deciding the extubation readiness in a long-term mechanically ventilated patient.
- 22 October 2018
- Published by Springer Nature in JA Clinical Reports
- Vol. 4 (1) , 1-4
Open AccessPredicting extubation readiness by monitoring the electrical activity of the diaphragm after prolonged mechanical ventilation: a pediatric case report
The intensity of the electrical activity of the diaphragm (Edi) correlates with inspiratory effort. The ratio of tidal volume to the Edi is known as neuroventilatory efficiency (NVE) and is used as an index for ventilation efficiency. Here, we present a case showing that Edi and NVE may be effective parameters to predict successful extubation. A 6-month-old female infant required prolonged mechanical ventilation after cardiac surgery. Fifty-two days after surgery, her trachea was extubated but required reintubation. Edi monitoring was initiated to assess diaphragm function. The Edi was > 70 mcV just after the reintubation, and her NVE was 1.0 mL/mcV, but gradually decreased. On day 59, her Edi values during the spontaneous breathing trials were 13 mcV with the improvement of NVE (2.5 mL/mcV) and her trachea was extubated without complications. The Edi and NVE were valuable for deciding the extubation readiness in a long-term mechanically ventilated patient.