CFCheng Fang

Cheng Fang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cheng Fang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Compact Photoacoustic Sensing Probe Using Surface-Micromachined Optical Ultrasound Transducer (SMOUT)

    by Cheng Fang, Xuan Li, Borui Li, Jun Zou

    In this paper, we report an innovative compact photoacoustic (PA) sensing probe based on a surface-micromachined optical ultrasound transducer (SMOUT). Owing to its excellent optical transparency, the excitation light can propagate through the SMOUT to the target, enabling the use of a single optical fiber for both excitation and reception. In addition, the SMOUT provides high acoustic sensitivity and good optical uniformity. For demonstration, a prototype PA sensing probe using the SMOUT has been designed, fabricated, and experimentally characterized. Red-dye solutions with different concentrations and a piece of black tape embedded at various depths in biological tissue are used as sensing targets, and the probe performance is validated by the experimental results. Overall, the compact and sensitive SMOUT-based probe shows strong potential for a wide range of PA sensing applications, and its uniform mass production makes it amenable to be arranged into 1-D and 2-D planar or spherical arrays for imaging applications.

  • Fiber-Tip Surface-Micromachined Optical Ultrasound Transducer (SMOUT) Probe for Acoustic Detection Induced by Ultrahigh Dose Rate (UHDR) Electron Beam

    by Cheng Fang, Borui Li, Dale W. Litzenberg, Issam El Naqa, Wei Zhang, Xueding Wang, Jun Zou

    !Online dose mapping is essential for safe and accurate beam delivery in FLASH radiation therapy (RT). While ionizing radiation acoustic imaging (iRAI) enables real-time, deep tissue dose measurement and beam localization for RT, previous piezoelectric acoustic sensors have suffered from electronic noise and neutron damage from ultra-high dose rate radiation (UHDR) beam. Described here is an innovative single-element full-optical surface-micromachined optical ultrasound transducer (SMOUT) mounted on an optical fiber tip to detect acoustic waves induced by UHDR beam. The design and fabrication of the fiber-tip SMOUT probe (diameter = 400 μm) have been demonstrated, and its optical and acoustic characteristics, as well as transmittance to the FLASH electron beam and imaging capability have been characterized. Experimental results show that the fiber-tip SMOUT probe has optical resonance wavelength (ORW) ~ 773 nm, acoustic central frequency ~ 300 kHz and −6 dB acoustic bandwidth ~ 160 kHz, and dose rate independent single pulse noise equivalent dose ~ 5.19 cGy. More importantly, the fiber-tip SMOUT probe exhibits negligible disturbance to FLASH irradiation. After 1-D scanning the fiber-tip SMOUT probe, the 2-D dose distribution of the FLASH electron beam can be mapped with high consistency. These findings highlight the potential of SMOUT based iRAI for mapping the dose distribution under UHDR beam, which is an important step toward practical implementation of iRAI-based online dosimetry in FLASH RT.

  • Open Access

    Pressure and Temperature Dependence of Optical Resonance Wavelength (ORW) of Large-Element Surface-Micromachined Optical Ultrasound Transducers (SMOUTs)

    by Kaustubh Upadhyay, Cheng Fang, Zhiyu Yan, Xuan Li, Jun Zou

    This paper investigates optical resonance wavelength (ORW) shifts in large-element, fiber-tip surface-micromachined optical ultrasound transducers (SMOUTs) induced by changes in ambient pressure and temperature. The displacement behavior of the SMOUT top membrane under varying pressure and temperature conditions is analyzed and modeled, and simulation results are presented for fiber-tip SMOUTs with four diameters (200, 400, 600, and 800 µm). Fabricated and assembled fiber-tip SMOUTs are experimentally characterized using two dedicated setups to measure their reflectivity spectra and ORW shifts over ambient pressures from 80 kPa to 120 kPa and temperatures from 25 °C to 45 °C. The experimental data show good agreement with the simulation results. These findings provide a solid basis for active control and compensation of ORW shifts via pressure and temperature adjustment. By stabilizing the reflectivity spectrum and minimizing ORW drift, the use of non-tunable high-power light sources to interrogate arrays of fiber-tip SMOUTs with enhanced operational stability and sensitivity is enabled.


  • Open Access

    Fine-Tuning of Optical Resonance Wavelength of Surface-Micromachined Optical Ultrasound Transducer Arrays for Single-Wavelength Light Source Readout

    by Zhiyu Yan, Cheng Fang, Jun Zou

    This article reports the fine-tuning of the optical resonance wavelength (ORW) of surface-micromachined optical ultrasound transducer (SMOUT) arrays to enable ultrasound data readout with non-tunable interrogation light sources for photoacoustic computed tomography (PACT). Permanent ORW tuning is achieved by material deposition onto or subtraction from the top diaphragm of each element with sub-nanometer resolution. For demonstration, a SMOUT array is first fabricated, and its ORW is tuned for readout with an 808 nm laser diode (LD). Experiments are conducted to characterize the optical and acoustic performances of the elements within the center region of the SMOUT array. Two-dimensional and three-dimensional PACT (photoacoustic computed tomography) is also performed to evaluate the imaging performance of the ORW-tuned SMOUT array. The results show that the ORW tuning does not degrade the optical, acoustic, and overall imaging performances of the SMOUT elements. As a result, the fine-tuning method enables new SMOUT-based PACT systems that are low cost, compact, powerful, and even higher speed, with parallel readout capability.


  • A Low-Cost Handheld Photoacoustic (PA) Probe for Rapid and Non-Destructive Detection of Watermelon Ripeness

    by Eric Zou, Cheng Fang, Dezhen Song

    For improving the quality and profitability of watermelon production, rapid and non-destructive detection of watermelon ripeness is important. Conventional acoustic and optical testing methods are based on indirect measurements, which require complex modeling and suffer from low accuracy. This paper reports the initial investigation of using photoacoustics (PA), a hybrid modality of light and sound, for non-destructive detection of watermelon rind thickness and inner flesh redness, the two visual hallmarks of watermelon ripeness. A new low-cost handheld PA probe is designed and fabricated to enable rapid and reliable PA measurements in air by simply touching the watermelon surface. The data acquisition capability of the PA probe is tested on personal watermelon samples with different rind thickness and embedded red-ink solutions to simulate different levels of flesh redness. The rind thickness and flesh redness are estimated based on the time-of-flight and correlation with the peak-to-peak amplitude of the acquired PA signal, respectively. The captured PA signals are also used to differentiate the rind thickness and flesh redness with Machine Learning. The results show that the new PA probe could provide a promising solution for rapid and non-destructive detection of the ripeness of watermelons, especially those in the field before harvesting.


  • An Optically Transparent Focused P(VDF-TrFE) Transducer for Photoacoustic Microscopy (PAM)

    by Cheng Fang, Zijie Zhao, Jie Fang, Jun Zou

    This paper reports a new optically-transparent focused P(VDF-TrFE) (poly(vinylidene fluoride-co-trifluoroethylene)) transducer for photoacoustic microscopy (PAM), which is fabricated by a new process based on pre-cutting and direct-lamination. Compared with the previous fabrication process, it is simpler, and makes it possible to achieve a high numerical aperture (NA) without stretching the (brittle) piezoelectric film. For demonstration, a prototype transducer has been fabricated with a 10-μm-thick 70/30 P(VDF-TrFE) film laminated onto a plano-concave glass lens with an acoustic NA of 0.64. Experimental characterizations show that the transducer has an optical transmittance of 88.6% (@ 532 nm), an acoustic center frequency and -3 dB bandwidth of 24 MHz and 29 MHz, respectively. Using the new optically-transparent focused P(VDF-TrFE) transducer, a PAM setup has been built to carry imaging experiments on different targets. Based on the experimental results, it can be concluded that the optically-transparent focused P(VDF-TrFE) transducer could be useful for the development of new PAM systems for different imaging applications.


  • Open Access

    A Wideband Noise and Harmonic Distortion Canceling Low-Noise Amplifier for High-Frequency Ultrasound Transducers

    by Yuxuan Tang, Yulang Feng, He Hu, Cheng Fang, Hao Deng, Runxi Zhang, Jun Zou, Jinghong Chen

    This paper presents a wideband low-noise amplifier (LNA) front-end with noise and distortion cancellation for high-frequency ultrasound transducers. The LNA employs a resistive shunt-feedback structure with a feedforward noise-canceling technique to accomplish both wideband impedance matching and low noise performance. A complementary CMOS topology was also developed to cancel out the second-order harmonic distortion and enhance the amplifier linearity. A high-frequency ultrasound (HFUS) and photoacoustic (PA) imaging front-end, including the proposed LNA and a variable gain amplifier (VGA), was designed and fabricated in a 180 nm CMOS process. At 80 MHz, the front-end achieves an input-referred noise density of 1.36 nV/sqrt (Hz), an input return loss (S11) of better than −16 dB, a voltage gain of 37 dB, and a total harmonic distortion (THD) of −55 dBc while dissipating a power of 37 mW, leading to a noise efficiency factor (NEF) of 2.66.


  • A Focused Optically Transparent PVDF Transducer for Photoacoustic Microscopy

    by Cheng Fang, He Hu, Jun Zou

    This papers reports the development of a novel focused optically-transparent ultrasound transducer with a wide bandwidth for photoacoustic microscopy (PAM). It consists of a 9- $\mu \text{m}$ -thick polyvinylidene fluoride (PVDF) film coated with Indium-tin oxide (ITO) and metal electrodes, which is laminated onto a concave glass lens. A new fabrication process was developed to ensure the formation of continuous ITO coatings on the curved transducer surface without fracturing. Both optical and acoustic experiments were conducted to characterize the performance of the transducer. The testing results show that the transducer has an optical transmittance of 60% (@ 532 nm), an acoustic center frequency of 24 MHz, and an acoustic bandwidth of 26 MHz. With an acoustic numerical aperture (NA) of 0.23, it provides a 0.13-mm acoustic focal spot and a 1.6-mm focal depth. For demonstration, a PAM setup was built for conducting PA imaging on different targets. In contrast to existing PAM systems, the use of the optically-transparent focused transducer allows a simpler and more compact configuration and easier alignment of the optical excitation and acoustic focal points. Such features are especially useful for the development of miniaturized PAM systems for handheld, wearable and even endoscopic applications.