SFS. H. Fu

S. H. Fu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


S. H. Fu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Zhen-Feng Ding

    School of Physics, Dalian University of Technology , Dalian 116024, China

    8 shared publications
  • Y. R. Yang

    Bolun Middle School 2 , Dalian 16031, China

    2 shared publications
  • L C Tian

    Lanzhou Institute of Physics, Lanzhou 730000, People’s Republic of China

    1 shared publication
  • Licheng Tian

    Key Laboratory of Materials Modification by Laser, Ion, and Electron Beams (Ministry of Education), Dalian University of Technology, Dalian, China

    1 shared publication
  • Yujun Ke

    Key Laboratory of Materials Modification by Laser, Ion, and Electron Beams (Ministry of Education), Dalian University of Technology, Dalian, China

    1 shared publication

Latest Publications

  • Open Access

    Self-mode transition, oscillation and inverse hysteresis in ECR discharges

    by Z. F. Ding, Y. R. Yang, S. H. Fu

    Positive and negative feedback of microwave (MW) ECR (electron cyclotron resonance) discharges in cross magnetic field were manipulated by a three-stub coaxial tuner. Unstable ECR discharges in the positive feedback region, such as the self-mode transition between the ordinary (O)-wave mode and extraordinary (X) one, inverse hysteresis, and oscillation, were investigated using a time-resolved MW power meter, high speed camera, and thermocouple. In the positive feedback region, the self-O → X wave mode discharge transition can be driven under the “hot” wall condition, while the counterpart, namely the self-X → O wave mode transition, is observable for the “cold” wall; the inverse hysteresis and oscillation take place at low and moderate gas flow rates, respectively. The mechanism underlying the self-mode transitions and instabilities is the discharge shift due to the gas heating effect. For MW ECR discharges to become stable, as indicated in previous experiments, they should be mismatched in the negative feedback region.


  • Size Optimization of Disk Antenna for 5-cm ECR Ion Thruster

    by Shenghui Fu, Zhenfeng Ding

    In a 2.45-GHz electron cyclotron resonance (ECR) ion thruster powered with a disk antenna in a cross magnetic field configuration, the optimized diameters of the disk antennae for the lowest breakdown power and the highest ion beam current were experimentally determined. The two optimized diameters are both in the medium region but do not coincide. The underlying mechanisms are discussed from the perspective of the vertical component of the microwave electric field in the ECR layer with respect to the static magnetic field and the charged-particle loss to the antenna and the chamber sidewall.


  • Open Access

    Effects of ion extraction on discharges in gridded ion source

    by Y. R. Yang, S. H. Fu, Z. F. Ding

    Effects of ion extraction on gridded ion source discharge or the coupling between ion extraction and gridded ion source discharge are investigated for the first time by correlating the ratio of the ion impingement current (Ia) to ion beam current (Ib) with the total gray values extracted from images of discharge glows with and without ion extraction. The results indicate that, under equal power and gas pressure, discharges with high and low Ia/Ib values in the presence of ion extraction are, respectively, more intensive and weaker than those without ion extraction. The competing factors behind the coupling between ion extraction and ion source discharge are ion loss and energetic secondary γ-electron injection from the accelerator grid, which weakens and enhances ion source discharge, respectively.


  • Effects of secondary γ-electrons from accelerator grid under ion impingement in gridded ion sources

    by S H Fu, L C Tian, Z F Ding

    Thus far, effects of secondary γ-electrons emitted from accelerator grids (AGs) of gridded ion sources on ionization in discharge chambers have not been studied. The presence and induced processes of such secondary electrons in a microwave electron cyclotron resonance gridded ion source are confirmed by the consistent explanations of: (1) the observed jump of ion beam current ( I b ) in case of a low-density plasma appearing at the chamber’s radial center due to the microwave skin effect; (2) the evolution of glow images recorded from the end-view of the ion source during the jump of I b ; (3) the over-large jump step of I b with increasing microwave power; (4) the pattern appearing on the temperature sticker exposed to the discharge operated in the regime where the arrayed energetic-electron beamlets are injected into the discharge chamber; (5) the measured step-increment in the voltage drop across the screen grid (SG) sheath. A positive feedback loop composed of involved processes is established to elucidate the underlying mechanism. Energetic γ-electrons from the AG and warm δ -electrons from the opposite antenna do not produce direct excitation and ionization, but they enhance the electrical confinement of cold electrons by elevating the voltage drop across the sheaths at the antenna and SG, thus leading to the jump of I b . The energetic γ-electrons-based model can be also modified to explain abnormal results observed in the other gridded ion sources. Energetic γ-electrons from AGs should be taken into account in understanding gridded ion sources.


  • Effects of gas adsorbed on solid surface during gas breakdown in electron cyclotron resonance discharges

    by S H Fu, Z F Ding

    The microwave breakdown power ( P wb ) in an ECR plasma source was not merely determined by pressure (gas flow rate), but found to vary with the time interval between two successive breakdowns. The measured P wb dropped rapidly from a high value at a short time interval to a low level at a long time interval. The obtained dependence of P wb on pressure (gas flow rate) exhibited distinct features: the normal monotonicity and abnormal non-monotonicity at the short and long time intervals, respectively. The effective zone in the antenna’s surface, bombarded by hot electrons heated in the ECR layer, was validated by (1) masking the antenna with a film having a variable radius; (2) calculating the distribution of the vertical component of the microwave electric field with respect to the static magnetic field; and (3) imaging glows of transient breakdown discharges with a fast camera. The reduction in P wb was mainly attributed to the enhanced emission of δ -electrons from the gas-adsorbed antenna under the bombardment of energetic electrons coming from the ECR layer. The correlation between the dynamic gas coverage and the emission coefficient of δ -electrons was established to understand the abnormal ECR breakdown features.


  • Comment on ‘Coincident ion acceleration and electron extraction for space propulsion using the self-bias formed on a set of RF biased grids bounding a plasma source’

    by S H Fu, Z F Ding

    The neutralizer-free ion thruster based on radio frequency (RF) acceleration was proposed as an attractive approach. This comment presents problems arising from such RF acceleration. Two mayor limitations in developing the neutralizer-free RF ion thruster into a practical technology are found to be involved with the grounded grid: (a) the high frequency bias required by low ion impingement from the upstream; (b) serious backstreaming of electron due to the grounded grid that cannot establish a potential barrier. Limitation (a) will degrade the ion production efficiency and cause more serious thermal deformation of the biased grids, especially for large-sized RF ion thrusters. Limitation (b) is the Achilles’ heel of a neutralizer-free RF-biased ion thruster: it in fact operates from the very beginning in the failure mode occurring in the final stage of seriously-eroded DC (direct current) biased ion thruster. The backstreaming electrons will substantially reduce the lifetime of neutralizer-free RF ion thrusters. In the current stage, the RF acceleration is not a promising neutralizer-free technology.


  • Characteristics of microwave ECR ion thruster powered with plate antenna in cross-magnetic field: Standing wave, skin effect, and mode transition

    by S. H. Fu, Z. F. Ding

    In a 2.45 GHz electron cyclotron resonance xenon ion source powered with circular plate-antenna, a rapid evolution of radial plasma-profile with discharge power in a region below 35 W and the abrupt jump of ion beam current accompanied by sudden radial-expansion of discharge glow were observed. Based on analyses about quantified glow images captured from the end-view of the discharge chamber and the ion beam current against the discharge power, the fast evolution of the radial plasma-profile is attributed to the counteraction of standing wave and the skin effect, the coincidence of enhanced microwave absorption in the electron plasma resonance layer, and the transverse magnetic confinement of electrons. The jump of ion beam current and the sudden radial-expansion of discharge glow are confirmed to be originated from the extraordinary-wave discharge at the electron cyclotron resonance layer beyond the plate antenna when the skin effect is dominant.


  • Design Optimization and Experiment of 5-cm ECR Ion Thruster

    by Shenghui Fu, Zhenfeng Ding, Yujun Ke, Licheng Tian

    A cross magnetic field configuration (CMFC) was selected to design a microwave electron cyclotron resonance (ECR) ion thruster with a chamber diameter of 5 cm. The design was performed using the COMSOL Multiphysics software. Based on the commercially available arc-shaped samarium-cobalt magnet, the balanced optimization of CMFC was achieved at the frequency of 2.45 GHz. In Xe ion extraction discharge excited with the originally selected rod antenna, arcing on its front end was confirmed. The arcing problem was solved by replacing with a circular plate antenna. In terms of Xe ion extraction, 5-cm CMFC ECR ion thruster was shown to be better than its counterparts. COMSOL plasma simulation was used to reproduce two opposite discharge profiles observed in experiments.