Hideki Ito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hideki Ito has a total of 160 co-authors. Here are the top co-authors by number of shared publications:
- Masato Mutsuga
Nagoya University Graduate School of Medicine
7 shared publications Akihiko Usui
Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Tokai National Higher Education and Research System , Nagoya, Japan
4 shared publicationsGoro Miyakoda
First Institute of New Drug Discovery, Otsuka Pharmaceutical Co., Ltd., Tokushima, Japan
4 shared publications- Yoshiyuki Tokuda
Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
4 shared publications - Akihiko Usui
Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
3 shared publications Akio Matsuura
Division of Cardiovascular Surgery, Ichinomiya Municipal Hospital, 2-2-22 Bunkyo, Ichinomiya, Aichi 491-8558, Japan
3 shared publications
Latest Publications
- Open Access
- 16 December 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 67 (1)
Impact of direct mesenteric perfusion on malperfusion in acute type A aortic dissection repair
OBJECTIVES: Mesenteric malperfusion in acute aortic dissection remains a life-threatening complication with no standardized treatment strategy. This study aimed to describe and evaluate the outcomes of our integrated approach combining exploratory laparotomy, immediate mesenteric reperfusion, and central aortic repair. METHODS: We retrospectively reviewed patients with acute aortic dissection with a preoperative diagnosis of mesenteric malperfusion who were treated between August 2011 and November 2022. Our surgical approach was to establish cardiopulmonary bypass, followed by exploratory laparotomy with mesenteric artery flow assessment using Doppler ultrasound and direct perfusion if needed, central aortic repair, and subsequent mesenteric artery reconstruction. The primary end-point was the 30-day operative mortality. RESULTS: Among 217 patients with acute aortic dissection, 12 (5.5%) had mesenteric malperfusion on preoperative computed tomography. Ten patients underwent exploratory laparotomy, where Doppler ultrasonography revealed reduced mesenteric blood flow in five patients (2.3% of the total 217 patients). These patients underwent direct perfusion of the mesenteric artery via a side branch of the cardiopulmonary bypass circuit. Doppler ultrasound confirmed the restoration of mesenteric blood flow in all perfused patients. No bowel resections were required. The operative mortality in patients with mesenteric malperfusion was 20%. The causes of death were stroke (n = 1) and acute myocardial infarction (n = 1). CONCLUSIONS: Our integrated surgical strategy combining central aortic repair with concurrent exploratory laparotomy and immediate mesenteric perfusion demonstrated technical feasibility in managing mesenteric malperfusion during aortic repair. Further prospective studies with larger cohorts are warranted to validate these findings.
- 16 December 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 67 (1)
Open AccessImpact of direct mesenteric perfusion on malperfusion in acute type A aortic dissection repair
OBJECTIVES: Mesenteric malperfusion in acute aortic dissection remains a life-threatening complication with no standardized treatment strategy. This study aimed to describe and evaluate the outcomes of our integrated approach combining exploratory laparotomy, immediate mesenteric reperfusion, and central aortic repair. METHODS: We retrospectively reviewed patients with acute aortic dissection with a preoperative diagnosis of mesenteric malperfusion who were treated between August 2011 and November 2022. Our surgical approach was to establish cardiopulmonary bypass, followed by exploratory laparotomy with mesenteric artery flow assessment using Doppler ultrasound and direct perfusion if needed, central aortic repair, and subsequent mesenteric artery reconstruction. The primary end-point was the 30-day operative mortality. RESULTS: Among 217 patients with acute aortic dissection, 12 (5.5%) had mesenteric malperfusion on preoperative computed tomography. Ten patients underwent exploratory laparotomy, where Doppler ultrasonography revealed reduced mesenteric blood flow in five patients (2.3% of the total 217 patients). These patients underwent direct perfusion of the mesenteric artery via a side branch of the cardiopulmonary bypass circuit. Doppler ultrasound confirmed the restoration of mesenteric blood flow in all perfused patients. No bowel resections were required. The operative mortality in patients with mesenteric malperfusion was 20%. The causes of death were stroke (n = 1) and acute myocardial infarction (n = 1). CONCLUSIONS: Our integrated surgical strategy combining central aortic repair with concurrent exploratory laparotomy and immediate mesenteric perfusion demonstrated technical feasibility in managing mesenteric malperfusion during aortic repair. Further prospective studies with larger cohorts are warranted to validate these findings.
- Open Access
- 6 June 2024
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 28 (1) , 83-89
Usefulness of bicarbonate-based Impella purge solution in a patient with heparin-induced thrombocytopenia: the first case report of long-term management in Japan
Percutaneous mechanical circulatory support utilizing micro-axial flow pumps, such as the Impella group of devices, has become a life-saving technique in the treatment of refractory cardiogenic shock, with ever-increasing success rates. A 30-year-old man presented with acute decompensated heart failure and a severely reduced left ventricular ejection fraction (17%). Despite initial treatment with inotropic drugs and intra-aortic balloon pump support, his hemodynamic status remained unstable. Transition to Impella CP mechanical circulatory support was made on day 6 owing to persistently low systolic blood pressure. A significant decline in platelet count prompted suspicion of heparin-induced thrombocytopenia (HIT), later confirmed by positive platelet-activated anti-platelet factor 4/heparin antibody and a 4Ts score of 6 points. Argatroban was initially used as the purge solution, but owing to complications, a switch to Impella 5.0 and a bicarbonate-based purge solution (BBPS) was performed. Despite additional veno-arterial extracorporeal membrane oxygenation support on day 24, the patient, aiming for ventricular assist device treatment and heart transplantation, died from infection and multiple organ failure. Remarkably, the Impella CP continued functioning normally until the patient’s demise, indicating stable Impella pump performance using BBPS. This case highlights the usefulness of BBPS as an alternative to conventional Impella heparin purge solution when HIT occurs.
- 6 June 2024
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 28 (1) , 83-89
Open AccessUsefulness of bicarbonate-based Impella purge solution in a patient with heparin-induced thrombocytopenia: the first case report of long-term management in Japan
Percutaneous mechanical circulatory support utilizing micro-axial flow pumps, such as the Impella group of devices, has become a life-saving technique in the treatment of refractory cardiogenic shock, with ever-increasing success rates. A 30-year-old man presented with acute decompensated heart failure and a severely reduced left ventricular ejection fraction (17%). Despite initial treatment with inotropic drugs and intra-aortic balloon pump support, his hemodynamic status remained unstable. Transition to Impella CP mechanical circulatory support was made on day 6 owing to persistently low systolic blood pressure. A significant decline in platelet count prompted suspicion of heparin-induced thrombocytopenia (HIT), later confirmed by positive platelet-activated anti-platelet factor 4/heparin antibody and a 4Ts score of 6 points. Argatroban was initially used as the purge solution, but owing to complications, a switch to Impella 5.0 and a bicarbonate-based purge solution (BBPS) was performed. Despite additional veno-arterial extracorporeal membrane oxygenation support on day 24, the patient, aiming for ventricular assist device treatment and heart transplantation, died from infection and multiple organ failure. Remarkably, the Impella CP continued functioning normally until the patient’s demise, indicating stable Impella pump performance using BBPS. This case highlights the usefulness of BBPS as an alternative to conventional Impella heparin purge solution when HIT occurs.
- Open Access
- 19 April 2024
- Published by IntechOpen
Cardiac Reshaping Net for Dilated Cardiomyopathy
Dilated cardiomyopathy (DCM) is an intractable disease that progressively worsens with cardiac enlargement and heart failure. There are approximately 20,000 patients designated with intractable disease who have moderate or severe heart failure symptoms even with appropriate medical treatment, making it the most common target disease for heart transplantation in Japan. Sixty percent of designated DCM patients are over the age of 60. If we can extend their healthy life expectancy by 5 to 10 years, we can reduce the number of patients who are candidates for heart transplantation. We have developed a patient-specific cardiac reshaping net (PS-CRN) to prevent progressive cardiac enlargement (=cardiac remodeling), which is the major factor in worsening heart failure. We have conducted three first-in-human clinical trials. The past and present of the “cardiac support net therapy” will be reviewed.
- 19 April 2024
- Published by IntechOpen
Open AccessCardiac Reshaping Net for Dilated Cardiomyopathy
Dilated cardiomyopathy (DCM) is an intractable disease that progressively worsens with cardiac enlargement and heart failure. There are approximately 20,000 patients designated with intractable disease who have moderate or severe heart failure symptoms even with appropriate medical treatment, making it the most common target disease for heart transplantation in Japan. Sixty percent of designated DCM patients are over the age of 60. If we can extend their healthy life expectancy by 5 to 10 years, we can reduce the number of patients who are candidates for heart transplantation. We have developed a patient-specific cardiac reshaping net (PS-CRN) to prevent progressive cardiac enlargement (=cardiac remodeling), which is the major factor in worsening heart failure. We have conducted three first-in-human clinical trials. The past and present of the “cardiac support net therapy” will be reviewed.
- Open Access
- 31 October 2023
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 37 (5)
Development of novel waxy bone haemostatic agents composed of biodegradable polymers with osteogenic-enhancing peptides in rabbit models
The use of bone wax (BW) is controversial for sternal haemostasis because it increases the risk of wound infection and inhibits bone healing. We developed new waxy bone haemostatic agents made from biodegradable polymers containing peptides and evaluated them using rabbit models. We designed 2 types of waxy bone haemostatic agents: peptide wax (PW) and non-peptide wax (NPW), which used poly(ε-caprolactone)-based biodegradable polymers with or without an osteogenesis-enhancing peptide, respectively. Rabbits were randomly divided into 4 groups based on treatment with BW, NPW, PW or no treatment. In a tibial defect model, the bleeding amount was measured and bone healing was evaluated by micro-computed tomography over 16 weeks. Bone healing in a median sternotomy model was assessed for 2 weeks using X-ray, micro-computed tomography, histological examination and flexural strength testing. The textures of PW and NPW (n = 12 each) were similar to that of BW and achieved a comparable degree of haemostasis. The crevice area of the sternal fracture line in the BW group was significantly larger than that in other groups (n = 10 each). The PW group demonstrated the strongest sternal flexural strength (n = 10), with complete tibial healing at 16 weeks. No groups exhibited wound infection, including osteomyelitis. Waxy biodegradable haemostatic agents showed satisfactory results in haemostasis and bone healing in rabbit models and may be an effective alternative to BW.
- 31 October 2023
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 37 (5)
Open AccessDevelopment of novel waxy bone haemostatic agents composed of biodegradable polymers with osteogenic-enhancing peptides in rabbit models
The use of bone wax (BW) is controversial for sternal haemostasis because it increases the risk of wound infection and inhibits bone healing. We developed new waxy bone haemostatic agents made from biodegradable polymers containing peptides and evaluated them using rabbit models. We designed 2 types of waxy bone haemostatic agents: peptide wax (PW) and non-peptide wax (NPW), which used poly(ε-caprolactone)-based biodegradable polymers with or without an osteogenesis-enhancing peptide, respectively. Rabbits were randomly divided into 4 groups based on treatment with BW, NPW, PW or no treatment. In a tibial defect model, the bleeding amount was measured and bone healing was evaluated by micro-computed tomography over 16 weeks. Bone healing in a median sternotomy model was assessed for 2 weeks using X-ray, micro-computed tomography, histological examination and flexural strength testing. The textures of PW and NPW (n = 12 each) were similar to that of BW and achieved a comparable degree of haemostasis. The crevice area of the sternal fracture line in the BW group was significantly larger than that in other groups (n = 10 each). The PW group demonstrated the strongest sternal flexural strength (n = 10), with complete tibial healing at 16 weeks. No groups exhibited wound infection, including osteomyelitis. Waxy biodegradable haemostatic agents showed satisfactory results in haemostasis and bone healing in rabbit models and may be an effective alternative to BW.
- 9 June 2021
- Published by Wiley in Geriatrics & Gerontology International
- Vol. 21 (8) , 748-749
Agreement on dementia severity levels between the 8‐item and 21‐item Dementia Assessment Sheet for Community‐based Integrated Care System
- 9 June 2021
- Published by Wiley in Geriatrics & Gerontology International
- Vol. 21 (8) , 748-749
Agreement on dementia severity levels between the 8‐item and 21‐item Dementia Assessment Sheet for Community‐based Integrated Care System
- 20 May 2020
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 68 (12) , 1594-1595
Upper thoracoabdominal aortic repair through partial posterior incision of the diaphragm via left thoracotomy
During surgical repair of a thoracoabdominal aortic aneurysm, division of the diaphragm should be minimized to avoid pulmonary complications. We herein describe a modified exposure technique that avoids ordinary circumferential division of the diaphragm. The diaphragm was detached from the aneurysm at the level of the aortic hiatus via a modified anterior lateral thoracotomy incision through the pleural space. The diaphragmatic incision around the aneurysm was extended posteriorly. This partial division of the diaphragm provided sufficient exposure of the distal anastomosis site for thoracoabdominal aneurysms that do not extend below the upper part of the abdomen.
- 20 May 2020
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 68 (12) , 1594-1595
Upper thoracoabdominal aortic repair through partial posterior incision of the diaphragm via left thoracotomy
During surgical repair of a thoracoabdominal aortic aneurysm, division of the diaphragm should be minimized to avoid pulmonary complications. We herein describe a modified exposure technique that avoids ordinary circumferential division of the diaphragm. The diaphragm was detached from the aneurysm at the level of the aortic hiatus via a modified anterior lateral thoracotomy incision through the pleural space. The diaphragmatic incision around the aneurysm was extended posteriorly. This partial division of the diaphragm provided sufficient exposure of the distal anastomosis site for thoracoabdominal aneurysms that do not extend below the upper part of the abdomen.
- Open Access
- 8 February 2020
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 58 (2) , 395-397
Modified sutureless repair using left atrial appendage flap for acquired left-sided pulmonary vein stenosis
Pulmonary vein stenosis is a well-known complication after radiofrequency catheter ablation of atrial fibrillation. Although surgical repair is indicated for younger patients and patients with multiple stenoses, the appropriate procedure for acquired pulmonary vein stenosis has not been established. In this study, we report the successful outcome of our modified sutureless technique using a left atrial appendage flap for left-sided pulmonary vein stenosis after radiofrequency catheter ablation.
- 8 February 2020
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 58 (2) , 395-397
Open AccessModified sutureless repair using left atrial appendage flap for acquired left-sided pulmonary vein stenosis
Pulmonary vein stenosis is a well-known complication after radiofrequency catheter ablation of atrial fibrillation. Although surgical repair is indicated for younger patients and patients with multiple stenoses, the appropriate procedure for acquired pulmonary vein stenosis has not been established. In this study, we report the successful outcome of our modified sutureless technique using a left atrial appendage flap for left-sided pulmonary vein stenosis after radiofrequency catheter ablation.
- Open Access
- 1 June 2019
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 5 (2) , 152-155
The efficacy of immediate bridging thoracic endovascular aortic repair for ruptured infected thoracic aortic aneurysms
- 1 June 2019
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 5 (2) , 152-155
Open AccessThe efficacy of immediate bridging thoracic endovascular aortic repair for ruptured infected thoracic aortic aneurysms
- Open Access
- 24 November 2018
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 82 (12) , 2998-3004
Strategy of Cardiovascular Surgery for Patients With Dementia as Evaluated by Mini-Mental State Examination
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 24 November 2018
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 82 (12) , 2998-3004
Open AccessStrategy of Cardiovascular Surgery for Patients With Dementia as Evaluated by Mini-Mental State Examination
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies