Virginia Di Taranto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Virginia Di Taranto has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Vincenzo Campanella
Department of Clinical Sciences and Traslational Medicine, Dental School, University of Rome “Tor Vergata”, 00133 Rome, Italy
9 shared publications A. Libonati
Department of Surgical Sciences, Dental School, Catholic University of Our Lady of Good Counsel of Tirane, Tirane, Albania
5 shared publicationsG. Gallusi
Department of Clinical Sciences and Translational Medicine, Dental School, University of Rome "Tor Vergata", Rome, Italy
4 shared publicationsG. Marzo
Department of Life, Health and Environmental Sciences, Dental School, University of L'Aquila, L'Aquila, Italy
4 shared publicationsR. Nardi
Department of Clinical Sciences and Translational Medicine, Dental School, University of Rome "Tor Vergata", Rome, Italy
4 shared publicationsA. Mea
Department of Clinical Sciences and Translational Medicine, Dental School, University of Rome "Tor Vergata", Rome, Italy
3 shared publications
Latest Publications
- Open Access
- 17 August 2026
- Published by Wiley in International Journal of Paediatric Dentistry
- Vol. 36 (6) , 875-882
Comparing Digital and Fluorescent Imaging for Detecting White Spot Lesions in Orthodontic Patients
Background: To perform orthodontic movements, brackets and ligatures must be placed on the teeth that facilitate plaque accumulation, which can lead to the formation of demineralization lesions. Aim: The purpose of this comparative study was to detect and measure WSLs using digital and fluorescence‐based methods in patients with malocclusions treated with fixed orthodontic appliances (brackets). Design: Seventeen patients, age 10–20 years old, 10 girls (58.8%), 7 boys (41.2%), and 273 teeth were analyzed. Their selection was based on six criteria: 1) no vestibular caries or fillings, 2) no dental fluorosis, 3) no hypocalcified teeth, 4) no tetracycline‐stained teeth, 5) no endocrine disorders, and 6) no participation in other experiments. Results: Digital photography identified a higher number of WSLs than VistaCam Proof at both time points, while agreement between methods was low (Kappa = 0.33 at T0; 0.17 at T1), indicating different lesion detection profiles. Conclusions: Digital photography and VistaCam Proof showed different WSL detection patterns and low inter‐method agreement. These findings suggest that the two methods are not interchangeable in longitudinal orthodontic monitoring. In the absence of an independent reference standard, the findings should be interpreted in terms of differences in lesion detection and agreement between methods rather than diagnostic performance.
- 17 August 2026
- Published by Wiley in International Journal of Paediatric Dentistry
- Vol. 36 (6) , 875-882
Open AccessComparing Digital and Fluorescent Imaging for Detecting White Spot Lesions in Orthodontic Patients
Background: To perform orthodontic movements, brackets and ligatures must be placed on the teeth that facilitate plaque accumulation, which can lead to the formation of demineralization lesions. Aim: The purpose of this comparative study was to detect and measure WSLs using digital and fluorescence‐based methods in patients with malocclusions treated with fixed orthodontic appliances (brackets). Design: Seventeen patients, age 10–20 years old, 10 girls (58.8%), 7 boys (41.2%), and 273 teeth were analyzed. Their selection was based on six criteria: 1) no vestibular caries or fillings, 2) no dental fluorosis, 3) no hypocalcified teeth, 4) no tetracycline‐stained teeth, 5) no endocrine disorders, and 6) no participation in other experiments. Results: Digital photography identified a higher number of WSLs than VistaCam Proof at both time points, while agreement between methods was low (Kappa = 0.33 at T0; 0.17 at T1), indicating different lesion detection profiles. Conclusions: Digital photography and VistaCam Proof showed different WSL detection patterns and low inter‐method agreement. These findings suggest that the two methods are not interchangeable in longitudinal orthodontic monitoring. In the absence of an independent reference standard, the findings should be interpreted in terms of differences in lesion detection and agreement between methods rather than diagnostic performance.
- Open Access
- 9 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11372
SEM Evaluation of the Hybrid Layer of Two Universal Adhesives on Sound and DI Type II Affected Dentin
Universal nanofilled adhesives were recently introduced in restorative dentistry to simplify clinical procedures and improve adhesion in different clinical situation. This study investigated the effectiveness of two universal adhesives on both sound and dentinogenesis imperfecta type II (DI-II)-affected teeth. To evaluate the effectiveness of adhesion on both sound and DI-II-affected teeth, four samples, two sound extracted molars and two extracted molars affected by DI-II were selected. Coronal enamel and dentin were exposed, and the samples were used for testing two different universal adhesives, Universal Bond (Tokuyama) and All-Bond Universal (Bisco). After the adhesive procedures, the samples were stored in saline at room temperature for one week prior to SEM investigation for the interfacial bonding layer. The samples were longitudinally sectioned into two parts, obtaining two sections for the evaluation of the adhesive interface to the SEM. The SEM-morphology of the hybrid layer on the enamel was similar for the two universal adhesives tested. The study of the hybrid layer on sound dentin confirmed the great versatility of All-Bond Universal and Universal Bond adhesives in managing adhesion even on pathological dental substrates. Both universal adhesives tested showed encouraging results on DI-II-affected dentin, creating an effective hybrid layer even on the atubular and less mineralized altered dentin.
- 9 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11372
Open AccessSEM Evaluation of the Hybrid Layer of Two Universal Adhesives on Sound and DI Type II Affected Dentin
Universal nanofilled adhesives were recently introduced in restorative dentistry to simplify clinical procedures and improve adhesion in different clinical situation. This study investigated the effectiveness of two universal adhesives on both sound and dentinogenesis imperfecta type II (DI-II)-affected teeth. To evaluate the effectiveness of adhesion on both sound and DI-II-affected teeth, four samples, two sound extracted molars and two extracted molars affected by DI-II were selected. Coronal enamel and dentin were exposed, and the samples were used for testing two different universal adhesives, Universal Bond (Tokuyama) and All-Bond Universal (Bisco). After the adhesive procedures, the samples were stored in saline at room temperature for one week prior to SEM investigation for the interfacial bonding layer. The samples were longitudinally sectioned into two parts, obtaining two sections for the evaluation of the adhesive interface to the SEM. The SEM-morphology of the hybrid layer on the enamel was similar for the two universal adhesives tested. The study of the hybrid layer on sound dentin confirmed the great versatility of All-Bond Universal and Universal Bond adhesives in managing adhesion even on pathological dental substrates. Both universal adhesives tested showed encouraging results on DI-II-affected dentin, creating an effective hybrid layer even on the atubular and less mineralized altered dentin.
- Open Access
Is Dental Amalgam a Higher Risk Factor rather than Resin-Based Restorations for Systemic Conditions? A Systematic Review
Objective: The aim of this study was to confirm the hypothesis that patients with one or more amalgam restorations have an increased risk for systemic diseases rather than patients with resin-based restorations. Data: The data search produced an initial 3568 total number of records. All titles and abstract were reviewed by five independent examiners, and only 36 records were selected for full text in depth examination. Out of these, only nine publications matched the inclusion criteria and were included in this systematic review. Sources: Electronic databases (MEDLINE, Scopus, Embase, and Web of Knowledge) were searched up to June 2019. In addition, a manual search was carried out on journals related to this topic. Study selection: All selected human clinical studies compared patients with dental amalgam restorations to patients with non-amalgam restorations on restorative material related diseases/health conditions with at least 50 patients and a reasonable follow up. The systemic effects of dental restorations were analyzed. As for any systemic effects, there was no difference between amalgam and composite restoration. Conclusions: With the limitations of the few available randomized controlled trials (RCTs) on the matter, amalgam restorations, similarly to other modern resin-based materials, were not related to an increased risk of systemic diseases or conditions. Clinical significance: On the basis of the available RCTs, amalgam restorations, if compared with resin-based fillings, do not show an increased risk for systemic diseases. There is still insufficient evidence to exclude or demonstrate any direct influence on general health. The removal of old amalgam restorations and their substitution with more modern adhesive restorations should be performed only when clinically necessary and not just for material concerns. In order to better evaluate the safety of dental amalgam compared to other more modern restorative materials, further RCTs that consider important parameters such as long and uniform follow up periods, number of restorations per patient, and sample populations representative of chronic or degenerative diseases are needed.
Open AccessIs Dental Amalgam a Higher Risk Factor rather than Resin-Based Restorations for Systemic Conditions? A Systematic Review
Objective: The aim of this study was to confirm the hypothesis that patients with one or more amalgam restorations have an increased risk for systemic diseases rather than patients with resin-based restorations. Data: The data search produced an initial 3568 total number of records. All titles and abstract were reviewed by five independent examiners, and only 36 records were selected for full text in depth examination. Out of these, only nine publications matched the inclusion criteria and were included in this systematic review. Sources: Electronic databases (MEDLINE, Scopus, Embase, and Web of Knowledge) were searched up to June 2019. In addition, a manual search was carried out on journals related to this topic. Study selection: All selected human clinical studies compared patients with dental amalgam restorations to patients with non-amalgam restorations on restorative material related diseases/health conditions with at least 50 patients and a reasonable follow up. The systemic effects of dental restorations were analyzed. As for any systemic effects, there was no difference between amalgam and composite restoration. Conclusions: With the limitations of the few available randomized controlled trials (RCTs) on the matter, amalgam restorations, similarly to other modern resin-based materials, were not related to an increased risk of systemic diseases or conditions. Clinical significance: On the basis of the available RCTs, amalgam restorations, if compared with resin-based fillings, do not show an increased risk for systemic diseases. There is still insufficient evidence to exclude or demonstrate any direct influence on general health. The removal of old amalgam restorations and their substitution with more modern adhesive restorations should be performed only when clinically necessary and not just for material concerns. In order to better evaluate the safety of dental amalgam compared to other more modern restorative materials, further RCTs that consider important parameters such as long and uniform follow up periods, number of restorations per patient, and sample populations representative of chronic or degenerative diseases are needed.
- Open Access
- 29 February 2020
- Published by Springer Nature in Research Square
Microbial Leakage Evaluation Of Warm Gutta – Percha Techniques
Background: To compare bacterial leakage of MicroHeat and continuous wave with and without endodontic sealer. Methods: Thirty – eight single – rooted extracted mandibular premolars were selected and randomly divided into four experimental groups (n=8) and two control groups (n=3). Teeth were prepared with Mtwo NiTi files and obturated with MicroHeat or System B with or without endodontic sealer. Three teeth were used as positive controls (Ct+) and three intact teeth served as negative controls (Ct-). All samples were tested for bacterial infiltration every day for 60 days. Results: On day 32 overall contamination value was 62,5% for Mseal, 75% for Mnoseal, 75% for SBseal and 37,8% for SBnoseal; after 60 days, the final contamination result was 100% for Mseal, Mnoseal and SBseal and 87,5% for SBnoseal. Conclusions: At the end of the observation period, groups showed no statistically significant differences.
- 29 February 2020
- Published by Springer Nature in Research Square
Open AccessMicrobial Leakage Evaluation Of Warm Gutta – Percha Techniques
Background: To compare bacterial leakage of MicroHeat and continuous wave with and without endodontic sealer. Methods: Thirty – eight single – rooted extracted mandibular premolars were selected and randomly divided into four experimental groups (n=8) and two control groups (n=3). Teeth were prepared with Mtwo NiTi files and obturated with MicroHeat or System B with or without endodontic sealer. Three teeth were used as positive controls (Ct+) and three intact teeth served as negative controls (Ct-). All samples were tested for bacterial infiltration every day for 60 days. Results: On day 32 overall contamination value was 62,5% for Mseal, 75% for Mnoseal, 75% for SBseal and 37,8% for SBnoseal; after 60 days, the final contamination result was 100% for Mseal, Mnoseal and SBseal and 87,5% for SBnoseal. Conclusions: At the end of the observation period, groups showed no statistically significant differences.
- 20 February 2020
- Vol. 34, 39-47
EFFECT OF PRESSURE AND LIGHT CURING OF COMPOSITE MICRO HARDNESS
The aim of this study is to evaluate the micro hardness Vickers of a composite micro hybrid polymerized under constant pressure. Twelve experimental samples were made equally divided into two groups: an experimental group and a control. Enamel plus HRi (Micerium) microbiotic composite resin, UD3 colour, was inserted into a syringe heater (ENA HEAT Composite Heating Conditioner) so that the material could be brought to a temperature of 39 degrees C. A defined amount of composite resin is taken from the syringe with a Heidemann spatula and placed between two slides, previously cleaned with 90 degrees alcohol. The samples are then inserted one at a time into a special device for constant pressure application. Vickers hardness measurements were made on the top of surfaces. The mean value of the samples belonging to the experimental group is 56.81 +/- 0.71. The mean value of the control samples is 52.02 +/- 2. The results obtained allow us to state that applying a constant pressure during the cementation phase of indirect adhesive restorations allows to obtain better mechanical characteristics of the composite used as a cementing agent.
- 20 February 2020
- Vol. 34, 39-47
EFFECT OF PRESSURE AND LIGHT CURING OF COMPOSITE MICRO HARDNESS
The aim of this study is to evaluate the micro hardness Vickers of a composite micro hybrid polymerized under constant pressure. Twelve experimental samples were made equally divided into two groups: an experimental group and a control. Enamel plus HRi (Micerium) microbiotic composite resin, UD3 colour, was inserted into a syringe heater (ENA HEAT Composite Heating Conditioner) so that the material could be brought to a temperature of 39 degrees C. A defined amount of composite resin is taken from the syringe with a Heidemann spatula and placed between two slides, previously cleaned with 90 degrees alcohol. The samples are then inserted one at a time into a special device for constant pressure application. Vickers hardness measurements were made on the top of surfaces. The mean value of the samples belonging to the experimental group is 56.81 +/- 0.71. The mean value of the control samples is 52.02 +/- 2. The results obtained allow us to state that applying a constant pressure during the cementation phase of indirect adhesive restorations allows to obtain better mechanical characteristics of the composite used as a cementing agent.
- 20 February 2020
- Vol. 34, 49-54
DENTINAL SUBSTRATE VARIABILITY AND BONDING EFFECTIVENESS: SEM INVESTIGATION
Though the literature reports a well-documented scientific evidence of the performance of modern adhesive systems on normal dentin, few researches are available on the interaction between adhesives and compromised dentin. In this study, the authors analyzed the microscopic structural aspects of the adhesive interface on two common altered dentin substrates: dentin contaminated by metallic oxides and caries affected dentin. Thirty teeth were selected and divided in three groups of ten teeth according to the different dentin substrate they had: (A) normal dentin, (B) caries-affected dentin and (C) dentin contaminated by metallic oxides. The experimental cavity preparation was realised exposing in each sample, portion of pathologic dentin and portion of sound dentin as control. Each cavity was restored with micro-hybrid composite, with total etching and a two-step adhesive system. Each sample was sectioned in two halves analysed with two SEM micro-morphological methods: direct observation and decalcification. SEM investigations were able to show the difference in thickness and morphology of the adhesive interface with the two different dentin variables. Caries affected dentin determined the formation of less distinctive resin tags with few micro-tags. Discoloured dentin showed a poor infiltration with few resin tags probably due to alterations in the tubular structures. The micro-morphological variability of dentin substrate influences the clinical efficacy of bonding restorations determining significant differences in the qualitative and quantitative aspects of resin tags.
- 20 February 2020
- Vol. 34, 49-54
DENTINAL SUBSTRATE VARIABILITY AND BONDING EFFECTIVENESS: SEM INVESTIGATION
Though the literature reports a well-documented scientific evidence of the performance of modern adhesive systems on normal dentin, few researches are available on the interaction between adhesives and compromised dentin. In this study, the authors analyzed the microscopic structural aspects of the adhesive interface on two common altered dentin substrates: dentin contaminated by metallic oxides and caries affected dentin. Thirty teeth were selected and divided in three groups of ten teeth according to the different dentin substrate they had: (A) normal dentin, (B) caries-affected dentin and (C) dentin contaminated by metallic oxides. The experimental cavity preparation was realised exposing in each sample, portion of pathologic dentin and portion of sound dentin as control. Each cavity was restored with micro-hybrid composite, with total etching and a two-step adhesive system. Each sample was sectioned in two halves analysed with two SEM micro-morphological methods: direct observation and decalcification. SEM investigations were able to show the difference in thickness and morphology of the adhesive interface with the two different dentin variables. Caries affected dentin determined the formation of less distinctive resin tags with few micro-tags. Discoloured dentin showed a poor infiltration with few resin tags probably due to alterations in the tubular structures. The micro-morphological variability of dentin substrate influences the clinical efficacy of bonding restorations determining significant differences in the qualitative and quantitative aspects of resin tags.
- Open Access
- 1 February 2020
- Published by Taylor & Francis in Clinical, Cosmetic and Investigational Dentistry
- Vol. ume 12, 17-24
CAD/CAM Customized Glass Fiber Post and Core With Digital Intraoral Impression: A Case Report
Background: After endodontic treatment, a proper restorative technique is necessary to ensure coronal seal and protection of residual dental structure; teeth which have lost two or more walls need to be restored with posts to increase retention and stability of final restoration. Posts can be distinguished in prefabricated and customized, which are manufactured by lost wax technique or CAD-CAM. Purpose: Digital dentistry has been developed to increase workflow precision and to accelerate production process; use of CAD-CAM to realize customized posts was limited to scanning plaster models obtained from traditional impressions. Patients and Methods: In the reported case an intraoral scan was used to mill a post and core restoration on an endodontically treated inferior premolar; this operative protocol was based on previous in vitro experiments that confirmed the ability of 3shape Trios scanner to read post-space up to 9 mm in depth. Results: The digital technique allows us to convert the concave surface of the root canal into the convex surface of the post, and realize an anatomical post and core that improves the biomechanics of the endodontically treated tooth reducing the possibility of root fractures. Conclusion: The use of an intraoral digital scanner represents an opportunity for the clinician as it speeds up the production of an anatomical post and core restorations.
- 1 February 2020
- Published by Taylor & Francis in Clinical, Cosmetic and Investigational Dentistry
- Vol. ume 12, 17-24
Open AccessCAD/CAM Customized Glass Fiber Post and Core With Digital Intraoral Impression: A Case Report
Background: After endodontic treatment, a proper restorative technique is necessary to ensure coronal seal and protection of residual dental structure; teeth which have lost two or more walls need to be restored with posts to increase retention and stability of final restoration. Posts can be distinguished in prefabricated and customized, which are manufactured by lost wax technique or CAD-CAM. Purpose: Digital dentistry has been developed to increase workflow precision and to accelerate production process; use of CAD-CAM to realize customized posts was limited to scanning plaster models obtained from traditional impressions. Patients and Methods: In the reported case an intraoral scan was used to mill a post and core restoration on an endodontically treated inferior premolar; this operative protocol was based on previous in vitro experiments that confirmed the ability of 3shape Trios scanner to read post-space up to 9 mm in depth. Results: The digital technique allows us to convert the concave surface of the root canal into the convex surface of the post, and realize an anatomical post and core that improves the biomechanics of the endodontically treated tooth reducing the possibility of root fractures. Conclusion: The use of an intraoral digital scanner represents an opportunity for the clinician as it speeds up the production of an anatomical post and core restorations.
- 1 May 2019
- Vol. 33 (3) , 51-61
COMPARATIVE ANALYSIS OF CLEANING ABILITY OF TWO ROTARY INSTRUMENT SYSTEMS: MTWO AND PROTAPER UNIVERSAL. AN IN VITRO SCANNING ELECTRON MICROSCOPIC STUDY
This study is to compare the cleaning effectiveness of two Ni-Ti files systems. Thirty single-rooted human teeth were selected and two NiTi rotary systems were used. Group A: canal shaping with ProTaper (R) Universal (Dentsply Tulsa Dental Specialties, Tulsa, OK) (PTU); Group B: (n=15) canal shaping with Mtwo Ni-Ti instruments (Sweden & Martina, Padova, Italy) and apical finishing with Mtwo Apical Ni-Ti instruments (Sweden & Martina, Padova, Italy). The amount of debris and smear layer were quantified on a basis of a numerical evaluation scale. The data established for scoring the debris and the smear layer was recorded separately and statistically analysed using the Kruskal-Wallis test. No significant differences were found for debris. Mtwo instruments resulted in significantly less smear layer (P<0.05) compared with ProTaper (R) Universal. Under the conditions of this study, Mtwo resulted in significantly less smear layer compared with canal preparation with ProTaper (R) Universal.
- 1 May 2019
- Vol. 33 (3) , 51-61
COMPARATIVE ANALYSIS OF CLEANING ABILITY OF TWO ROTARY INSTRUMENT SYSTEMS: MTWO AND PROTAPER UNIVERSAL. AN IN VITRO SCANNING ELECTRON MICROSCOPIC STUDY
This study is to compare the cleaning effectiveness of two Ni-Ti files systems. Thirty single-rooted human teeth were selected and two NiTi rotary systems were used. Group A: canal shaping with ProTaper (R) Universal (Dentsply Tulsa Dental Specialties, Tulsa, OK) (PTU); Group B: (n=15) canal shaping with Mtwo Ni-Ti instruments (Sweden & Martina, Padova, Italy) and apical finishing with Mtwo Apical Ni-Ti instruments (Sweden & Martina, Padova, Italy). The amount of debris and smear layer were quantified on a basis of a numerical evaluation scale. The data established for scoring the debris and the smear layer was recorded separately and statistically analysed using the Kruskal-Wallis test. No significant differences were found for debris. Mtwo instruments resulted in significantly less smear layer (P<0.05) compared with ProTaper (R) Universal. Under the conditions of this study, Mtwo resulted in significantly less smear layer compared with canal preparation with ProTaper (R) Universal.
- 1 January 2019
- Vol. 20 (1) , 73-78
Clinical antibacterial effectiveness Healozone Technology after incomplete caries removal
Aim Aim of this study was to evaluate the local effects of ozone gas on bacteria present within deep carious lesions after selective caries excavation. Materials and methods The present study included 75 patients who had at least two Class caries with deep lesion D2 and/or D3. The cavities were divided into 2 groups: the ozone group received treatment with Healozone X4, while the control group did not receive any treatment. Dentin samples were taken from both groups using two sterile multi-blade drills at 800 rpm without irrigation. The drills were then stored in separate tubes, each containing 5ml of RTF (Reduced Transport Fluid) and placed in culture for the next two hours. A total microbial count of the CFU of Streptococcus Mutans and Lactobacillus was performed. Conclusions From the analysis of data on the dentin samples treated with ozone, there is a decrease in the bacterial load present in the infected carious dentin.
- 1 January 2019
- Vol. 20 (1) , 73-78
Clinical antibacterial effectiveness Healozone Technology after incomplete caries removal
Aim Aim of this study was to evaluate the local effects of ozone gas on bacteria present within deep carious lesions after selective caries excavation. Materials and methods The present study included 75 patients who had at least two Class caries with deep lesion D2 and/or D3. The cavities were divided into 2 groups: the ozone group received treatment with Healozone X4, while the control group did not receive any treatment. Dentin samples were taken from both groups using two sterile multi-blade drills at 800 rpm without irrigation. The drills were then stored in separate tubes, each containing 5ml of RTF (Reduced Transport Fluid) and placed in culture for the next two hours. A total microbial count of the CFU of Streptococcus Mutans and Lactobacillus was performed. Conclusions From the analysis of data on the dentin samples treated with ozone, there is a decrease in the bacterial load present in the infected carious dentin.
- 25 April 2018
- Vol. 32 (2) , 397-405
Comparison of coronal leakage of different root canal filling techniques: an ex vivo study.
The aim of this study was to compare the quality of the coronal seal, using an in vitro bacterial invasion test, of three different root canal filling systems. Twenty-seven freshly extracted mandibular premolars were selected and divided into three experimental groups (G1, G2 and G3 n=7) and two control groups (Ct+ and Ct- n=3). All teeth in the experimental groups were prepared using NiTi Mtwo rotating instruments and then the endodontic treatments were completed using the three-tested warm guttapercha root filling techniques: Microseal (G1), Thermafil (G2) and System B (G3). All root filling techniques were performed using the same endodontic sealer (Pulp Canal Sealer). Three teeth were instrumented and not filled, serving as positive controls (Ct+) and the last three teeth, with intact crowns and no endodontic treatment, served as negative controls (Ct-). All samples were mounted in a two-chamber apparatus and exposed to Enterococcus faecalis performing a bacterial infiltration test. All samples were observed for a maximum period of 60 days checking for turbidity of the BHI broth on a daily basis recording when contamination occurred. A quantitative evaluation of the bacterial CFU/ml was performed using the URO-QUICK™ system. On day 32 an overall value was recorded of contamination of 42.85% for group G1, 71.42% for G2 and 42.85% for G3; after 60 days, the final contamination result was 85.71% for group G1, and 100% for both G2 and G3 groups. Considering the number of contaminated samples at the end of the observation period, the three techniques showed no statistically significant differences. The study highlighted the bacterial permeability of gutta-percha/seal barrier, underlining the importance of an effective coronal restoration to ensure a durable seal after root canal treatment.
- 25 April 2018
- Vol. 32 (2) , 397-405
Comparison of coronal leakage of different root canal filling techniques: an ex vivo study.
The aim of this study was to compare the quality of the coronal seal, using an in vitro bacterial invasion test, of three different root canal filling systems. Twenty-seven freshly extracted mandibular premolars were selected and divided into three experimental groups (G1, G2 and G3 n=7) and two control groups (Ct+ and Ct- n=3). All teeth in the experimental groups were prepared using NiTi Mtwo rotating instruments and then the endodontic treatments were completed using the three-tested warm guttapercha root filling techniques: Microseal (G1), Thermafil (G2) and System B (G3). All root filling techniques were performed using the same endodontic sealer (Pulp Canal Sealer). Three teeth were instrumented and not filled, serving as positive controls (Ct+) and the last three teeth, with intact crowns and no endodontic treatment, served as negative controls (Ct-). All samples were mounted in a two-chamber apparatus and exposed to Enterococcus faecalis performing a bacterial infiltration test. All samples were observed for a maximum period of 60 days checking for turbidity of the BHI broth on a daily basis recording when contamination occurred. A quantitative evaluation of the bacterial CFU/ml was performed using the URO-QUICK™ system. On day 32 an overall value was recorded of contamination of 42.85% for group G1, 71.42% for G2 and 42.85% for G3; after 60 days, the final contamination result was 85.71% for group G1, and 100% for both G2 and G3 groups. Considering the number of contaminated samples at the end of the observation period, the three techniques showed no statistically significant differences. The study highlighted the bacterial permeability of gutta-percha/seal barrier, underlining the importance of an effective coronal restoration to ensure a durable seal after root canal treatment.