IBIgor' V. Boykov

Igor' V. Boykov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Igor' V. Boykov has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Influence of liver iron content on the accuracy of magnetic resonance assessment of steatosis: the role of proton density fat fraction and limitations of simplified metrics

    by Yury N. Savchenkov, Савченков Юрий Николаевич, Gennady E. Trufanov, Труфанов Геннадий Евгеньевич, Vladimir A. Fokin, Фокин Владимир Александрович, Elena A. Ionova, Ионова Елена Александровна, Alina P. Savchenkova, Савченкова Алина Петровна, et al.

    Background: The impact of physiological variations in hepatic iron content on the accuracy of MRI-based quantitative assessment of the liver fat fraction remains understudied. In this study, we systematically evaluated the robustness of proton density fat fraction and the nature of errors in simplified steatosis metrics. Aim: To evaluate the influence of hepatic iron content within the physiological range on the accuracy of MRI-based quantitative steatosis assessment and to assess the robustness of proton density fat fraction relative to simplified signal intensity–based MRI metrics. Methods: This retrospective observational study included 238 patients without clinically significant hepatic iron overload (iron concentration ≤2 mg/g dry weight). The liver fat fraction was quantified using proton density fat fraction and simplified MRI metrics based on signal intensity analysis. Single-voxel proton magnetic resonance spectroscopy was used as the quantitative reference for steatosis. Hepatic iron content was determined by R2* relaxometry and converted to mg/g dry weight. Statistical analysis included Spearman correlation, Bland–Altman agreement analysis, and regression modeling. Multiple comparisons were adjusted using the Benjamini–Hochberg false discovery rate correction (FDR 0.05). Results: Proton density fat fraction showed excellent agreement with single-voxel proton magnetic resonance spectroscopy (ρ = 0.98; p 0.001) with no evidence of systematic bias related to physiological iron variations. Despite the absence of iron overload, hepatic iron content increased with increasing steatosis severity (ρ = 0.55; p 0.001). Simplified metrics FF1 and FF2 correlated strongly with proton density fat fraction (ρ = 0.92 and 0.93; p 0.001) but showed systematic bias and wider limits of agreement at higher fat fractions. Hepatic iron was an independent source of error in simplified metrics : FF1 was predominantly affected by an additive error component that was partially correctable, whereas FF2 exhibited pronounced nonlinear and poorly correctable discrepancies. Conclusion: Proton density fat fraction is a robust quantitative reference for liver steatosis in the absence of iron overload. Simplified signal intensity–based MRI metrics have fundamental quantitative limitations. Physiological hepatic iron content may worsen their errors, requiring cautious interpretation, particularly in advanced steatosis.

  • Open Access

    Early diagnosis of Alzheimer’s disease: potential of 18F-FDG PET as a biomarker of neurodegeneration

    by Andrey Yu. Emelin, Igor' V. Litvinenko, Vladimir Yu. Lobzin, Ivan A. Lupanov, Kristina A. Kolmakova, Pavel S. Dynin, Igor' V. Boykov

    BACKGROUND: Dementia is considered one of the most actual medical problems of our time, being one of the main causes of disability among the elderly, and its prevalence will only increase in the coming years. The first place among conditions leading to dementia is given to Alzheimer’s disease (up to 70%). The effectiveness of Alzheimer’s disease therapy largely depends on the timeliness of diagnosis, which leads to the need to search for diagnostic markers that allow to detect the disease at the earliest stages. AIM: To evaluate the possibilities of using 18F-FDG PET for the early diagnosis of Alzheimer’s disease. MATERIALS AND METHODS: Cerebral metabolism was assessed using positron emission tomography with 18F-FDG. A total of 183 patients were divided into groups depending on their diagnosis and the severity of cognitive impairment. RESULTS: A characteristic pattern of cerebral metabolic disorders has been established in patients with Alzheimer’s disease. It can be detected in the early pre-dementia stages and has developmental features as the disease progresses. The pattern was characterized by bilateral hypometabolism in the parietal and temporal cortex with a predominance in its mediobasal sections. An important marker of the development of the neurodegenerative process was a metabolic disorder of the cingulate gyrus, the posterior sections of which are affected already at the earliest stages of the disease, while the involvement of its anterior sections reflects the transition to the stage of severe dementia. Described metabolic disorders prevailed in the dominant (left) brain hemisphere at all stages of the disease. CONCLUSION: Currently 18F-FDG PET can be considered the most informative of the available methods for the early diagnosis of Alzheimer’s disease which have a fairly high degree of accuracy.


  • Open Access

    Comparative assessment of cerebral perfusion and metabolism in patients with Alzheimer’s disease and vascular cognitive disorders

    by Andrey Y. Emelin, Igor' V. Boykov, Vladimir Y. Lobzin, Kristina A. Kolmakova, Konstantin M. Naumov, Pavel S. Dynin, Ivan A. Lupanov

    BACKGROUND: The high medical and social significance of the problem determines the necessity of the earliest nosological diagnostics of the cognitive disorders. Functional neuroimaging methods such as single-photon emission computed tomography and positron emission tomography play an important role in the early differential diagnosis, allowing to estimate perfusion and metabolism of the cerebral tissue. AIM: To perform a comparative analysis of perfusion and metabolic abnormalities in different cerebral structures of patients with Alzheimer’s disease and vascular cognitive disorders in small cerebral vessels disease. MATERIALS AND METHODS: Single-photon emission computed tomography was performed in 13 patients with Alzheimer’s disease and in 21 patients with vascular cognitive disorders; positron emission tomography with 18F-FDG was performed in 17 patients with Alzheimer’s disease and in 15 patients with vascular cognitive disorders. RESULTS: Patterns of perfusion and metabolic abnormalities differ in patients with Alzheimer’s disease and vascular cognitive disorders. In patients with vascular cognitive disorders due to cerebral small vessels disease, a distinctive feature was a combination of hypoperfusion in subcortical structures, especially in the caudate nucleus and thalamus, with hypoperfusion in the deep parts of the frontal lobe. In Alzheimer’s disease, bilateral pronounced perfusion abnormalities in the parietal and temporal cortex were the most characteristic. Patterns of metabolic disturbances were similar to patterns of perfusion disturbances in different variants of cognitive disorders, but metabolic disturbances were more widespread. Рositron emission tomography was more informative in diagnosing patients with Alzheimer’s disease compared to single photon emission computed tomography. More pronounced perfusion and metabolic disorders were observed in patients with more severe cognitive disorders. Perfusion disturbances in the area of subcortical structures can be considered as an early marker of cognitive impairment development in patients with small vessel disease. CONCLUSION: Single photon emission computed tomography has sufficient sensitivity and specificity when examining patients with vascular cognitive disorders, while positron emission tomography is more preferable when examining patients with Alzheimer-type dementia.


  • Open Access

    Chorionic bump: ultrasound predictor of adverse pregnancy outcome

    by Igor S. Zheleznyak, Vladimir V. Ryazanov, Gulnaz K. Sadykova, Igor V. Boykov, Sergey G. Glebov, Natalya Yu. Kuznetsova, Anastasiya Ya. Latysheva, Roman A. Postanogov, Кузнецова Наталья Юрьевна

    For the first time R. Harris et al. in 2006 a chorionic bump was described, detected by ultrasound examination in the first trimester of pregnancy, having characteristic ultrasound signs and localization. Modern knowledge about the etiology and clinical significance of chorionic bump for predicting the outcome of pregnancy is insufficient and contradictory. Inconsistency of the data may be due to the rarity of occurrence, a small sample of the studied groups, the lack of histopathological studies. Among doctors who make ultrasound investigations there is a low awareness of chorionic bump and as a result an erroneous interpretation of sonography data. Nevertheless, there is more and more evidence that this sign is a predictor of an adverse outcome of pregnancy. Doctors who make ultrasound investigations in the first trimester of pregnancy should be aware of the chorionic bump and be able to differentiate it with other pathological conditions. If a chorionic bump is detected, ultrasound examination in dynamics should be recommended. Based on the study of domestic and foreign literature, this scientific review presents modern ideas about the pathomorphology of chorionic bump, informations about significance in terms of predicting the outcome of pregnancy, and the main aspects of ultrasound diagnostics and differential diagnosis of this pathology.


  • Open Access

    Diagnostic imaging of ovarian endometrioma rupture with hemoperitoneum

    by Vladimir V. Ryazanov, Gulnaz K. Sadykova, Igor S. Zheleznyak, Igor V. Boykov, Victor V. Ipatov, Roman A. Postanogov

    An endometrioid ovarian cyst (known as endometrioma) is the most common variant of external endometriosis. Clinical symptoms range from asymptomatic to negatively affecting on quality of life and daily activities of a reproductive age woman. Rupture of an endometrioid cyst with hemorrhage into the abdominal cavity occurs in 3% of women with this pathology, which is a rare complication. Ruptured endometrioid cysts may present a diagnostic and surgical challenge: patients may have acute abdominal symptoms and hemodynamic instability, also imaging of a ruptured endometrioid cyst may mimic ovarian malignancy. Therefore, the emergency radiologist needs to know the semiotics of an endometrioid cyst with rupture and hemorrhage into the abdominal cavity. We represent the clinical case of a prime diagnosed large endometrioid cyst in a 32-year-old patient, complicated by hemorrhage in the abdominal cavity. In the emergency department, the patient underwent native computed tomography and ultrasound investigation. Based on the study of Russian and foreign literature, the review was made about main aspects of radiation semiotics of endometrioid cysts with rupture and hemorrhage in the abdominal cavity and about of differential diagnosis of rupture of endometrioid cysts with ruptures of functional cysts and malignant cystic ovarian formations.


  • Open Access

    A new method for determining the volume of fluid in the pleural cavity using computed tomography

    by T. D. Magdanov, С. Д. Рудь, I. V. Boykov, T. E. Rameshvili, V. N. Malakhovskiy

    INTRODUCTION:Despite the existence of many methods and formulas for calculating the volume of pleural effusion in radiation diagnostics, there is still no single approved method for determining the volume of pleural effusion. Features of the anatomical structure of the chest and pleural cavity, the specific location of the effusion in this cavity and the need for a quick and easy way to calculate the volume of fluid in the pleural cavity determine the relevance of our study.OBJECTIVE:Based on the studied approved methods for calculating the volume of pleural fluid, propose a new method that takes into account the anatomical features of the form of the pleural effusion. Evaluate the results of the proposed methods, compare with the result of the most commonly used method at present.MATERIAL AND METHODS:The study included studies of 114 patients who underwent computed tomography of the chest cavity. The CT protocol was performed according to the standard program and included standard thin section reconstruction with a thickness of 0.625–1.25 mm with or without intravenous contrast. The results of the proposed method for calculating the volume of liquid were compared statistically with the volume of liquid obtained using the Simpson method. For volumes obtained, Bland-Altman plots were constructed, Wilcoxon criteria for related samples were determined, Spearman coefficients were calculated, and comparative volume plots were plotted with 95% confidence intervals.RESULTS:According to the results of statistical analysis, it was found that the average bias according to the Blunt-Altman method for the strip thickness formula was 51.5. The boundaries of the spread of values [463,7: –360]. For the ellipsoid difference method, the average bias was –0.6, the boundaries of the spread of values [187.3: –188.5].CONCLUSIONS.Calculating the volume of pleural fluid on CT remains one of the problems that does not have a single accurate method. The new ellipsoid volume difference method proposed by us showed high statistical results and showed an advantage over the «strip thickness» method.


  • Open Access

    Role of radiologic imaging complex in morpho-pathogenetic approach to sanatorium resort intensity regimen selection in patients with dorsopathies

    by S. V. Shershnev, V. V. Ipatov, I. I. Khalipova, L. A. Kulova, V. N. Malakhovsliy, I. V. Boykov, T. E. Rameshvili, G. G. Romanov, V. S. Babirin, I. S. Zheleznyak

    Роль комплексного лучевого обследования в формировании морфо-патогенетического подхода к выбору режимов лечебного воздействия в санатории у больных дорсопатиями

  • Open Access

    High-technologic methods of laryngeal cancer diagnostics: a clinical case

    by Y. N. Priporova, A. L. Serebryakov, B. V. Kuts, V. S. Ushakov, V. V. Ipatov, I. V. Boykov

    Высокотехнологичные методы в диагностике рака гортани: клинический случай