RGRon Gilat

Ron Gilat

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ron Gilat has a total of 163 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of Mechanical Alignment on Clinically Significant Outcomes, Reoperation, and Failure After Osteochondral Allograft Transplantation of the Knee

    by Krish S. Sardesai, Jakob Ackermann, Tomas Vega, Kyle N. Kunze, Jason E. Jesse, Samuel Alfonsi, Brian E. Caplan, Jacob T. Morgan, Lee R. Friedman, Ron Gilat, et al.

    Background: Identifying and addressing mechanical malalignment is an important component of treating symptomatic osteochondral defects with osteochondral allograft (OCA) transplantation. However, little is known about how malalignment influences short- to midterm outcomes after OCA transplantation. Purpose: To evaluate whether mechanical alignment measurements including the hip-knee-ankle (HKA) angle, lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and joint line convergence angle (JLCA) predict clinically significant outcome achievement, graft failure, and reoperation after OCA transplantation with or without concomitant realignment. Study Design: Case series; Level of evidence, 4. Methods: Patient-reported outcome measures (PROMs) were collected preoperatively and at a minimum 2-year follow-up in patients receiving OCA from 2005 to 2023. PROMs included the International Knee Documentation Committee score and Knee injury and Osteoarthritis Outcome Score subscales. Clinically significant outcome thresholds were the minimal clinically important difference (MCID), substantial clinical benefit (SCB), and Patient Acceptable Symptom State (PASS). Preoperative full-length, weightbearing radiographs were used to measure the HKA angle, LDFA, MPTA, and JLCA. Multivariable logistic regression was used for clinically significant outcome achievement and all-cause reoperation; failure and arthroplasty were summarized descriptively because of the low number of events. Results: A total of 66 patients (mean age, 34.1 ± 11.5 years; mean body mass index, 27.8 ± 4.8 kg/m 2 ; 50% female) met inclusion criteria. Mean alignment measurements were 1.8°± 4.0° for the HKA angle, 86.8°± 2.3° for the LDFA, 86.3°± 2.3° for the MPTA, and 1.7°± 1.0° for the JLCA. Although PROMs improved at the final follow-up, no preoperative alignment measure was statistically associated with MCID, PASS, or SCB achievement or with all-cause reoperation ( P > .05). In total, 25 (37.9%) patients underwent reoperation; graft survivorship was 93.9%, with 4 failures and 3 arthroplasty conversions. In an exploratory subanalysis, 16 patients with an HKA angle >5° of varus or valgus (13 with concomitant realignment) did not have significantly different rates of reoperation (43.8% vs 36.0%; P = .768) or graft failure (6.3% vs 6.0%; P > .999) compared to their remaining counterparts. Conclusion: In this small, heterogeneous cohort, preoperative mechanical alignment measures were not statistically associated with clinically significant outcome achievement or all-cause reoperation after OCA transplantation. These hypothesis-generating findings do not establish the absence of an alignment effect or define a threshold for realignment because most patients with severe preoperative malalignment underwent concomitant realignment, which may have contributed to the favorable overall outcomes, and failure events were infrequent.

  • Preoperative Subchondral Insufficiency Fractures Are Associated With Decreased Clinically Significant Outcome Achievement, Higher Reoperation Rates, and Greater Osteoarthritis Progression After Medial Meniscus Posterior Root Repair at a Minimum 2‐Year Follow‐Up

    by Jose Rafael Garcia, Eric M. Cohen, Ron Gilat, Michael Ralls, Myles A. Atkins, Michael Murray, Kyleen Jan, Udit Dave, Brian J. Cole, Adam B. Yanke, et al.

    Purpose: To evaluate the effect of preoperative subchondral insufficiency fracture of the knee (SIFK) on the outcomes of medial meniscus posterior root tear repair. Methods: Patients undergoing repair of an isolated primary medial meniscus posterior root tear with ≥2‐year follow‐up were included. Data encompassed demographics, history, magnetic resonance imaging‐confirmed SIFK, subsequent surgery, radiographic osteoarthritis progression, and patient‐reported outcome measures: Knee Injury and Osteoarthritis Outcome Score, Joint Replacement; International Knee Documentation Committee; and Veterans RAND 12‐Item Health Survey. Patients were stratified by SIFK status. Clinically significant improvement was assessed using cohort‐specific minimal clinically important difference thresholds. Results: Ninety‐one patients (mean age: 56.5 ± 9.4 years, 73.6% women; mean body mass index: 32.5 ± 6.1) were included with a follow‐up of 38.3 ± 15.3 months (range, 24‐82), which did not differ between groups ( P = .841). Thirty‐four patients (37.4%) had SIFK, and 85% had SIFK grade 1 or 2. Baseline characteristics did not differ between groups. Compared with patients without SIFK, those with SIFK showed lower rates of achieving the minimal clinically important difference and patient‐acceptable symptom state for Knee Injury and Osteoarthritis Outcome Score, Joint Replacement (80.7% vs 38.2%, P < .001; 61.4% vs 35.3%, P = .028, respectively). Patients with SIFK demonstrated higher rates of subsequent surgery (20.6% [95% confidence interval, 8.7%‐37.9%] vs 5.3% [95% confidence interval, 1.1%‐14.6%]; risk difference, 15.3% [95% confidence interval, 1.6%‐31.9%]; P = .036) and a higher postoperative Kellgren‐Lawrence grade (median [interquartile range], 3.0 [3.0‐4.0] vs 2.0 [2.0‐3.0]; P = .013), with smaller postoperative joint space (2.8 ± 0.6 mm vs 3.8 ± 1.0 mm, P = .002). Conclusions: Preoperative SIFK is associated with lower rates of achieving meaningful clinical improvement along with a higher likelihood of subsequent surgeries and inferior postoperative radiographic osteoarthritis outcomes after medial meniscus posterior root tear repair. Level of Evidence: Level III, retrospective cohort study.

  • Improved Outcomes and Low Rate of Medical Discharge at a Minimum 10‐Year Follow‐Up After Arthroscopic Bankart Repair With Remplissage for “Off‐Track” Engaging Hill‐Sachs Lesions With Subcritical Glenoid Bone Loss in Active‐Duty Servicemembers

    by Erel Ben‐Ari, Brandon Chung, Alexis B. Sandler, John P. Scanaliato, Ron Gilat, Hunter Czajkowski, Nata Parnes

    Purpose: To evaluate long‐term outcomes after arthroscopic Bankart repair with remplissage among active‐duty servicemembers under 45 years old with engaging Hill‐Sachs lesions (HSLs) and subcritical glenoid bone loss (GBL). Methods: A retrospective review of prospectively collected data involving consecutive active‐duty servicemembers who underwent arthroscopic Bankart repair with remplissage for anterior instability with “off‐track” HSL and GBL 2 . At final follow‐up, PROMs improved (visual analog scale: 7.65‐1.6, American Shoulder and Elbow Surgeons: 40.3‐88.2, Single Assessment Numeric Evaluation: 48.6‐90.0, and Rowe: 39.0‐88.6, P < .0001), with sustained PROMs between mid‐ and long‐term time points. The minimal clinically important difference was achieved by most patients (76.2%‐95.2%). Two patients (9.0%) experienced complications: 1 with recurrent instability prompting Latarjet (4.5%) and 1 with postoperative stiffness (4.5%). At final follow‐up, return to duty was achieved by 86.4% (n = 19) and to preinjury level of sport by 90.9% (n = 20). Three patients underwent medical discharge from the military because of the operative shoulder (13.6%). Conclusions: At a minimum 10‐year follow‐up after arthroscopic Bankart repair with remplissage for off‐track HSL with subcritical GBL, active‐duty servicemembers showed sustained improvements in PROMs, low rates of recurrent instability, and relatively high rates of return to active‐duty and sport, supporting the durability of this procedure in a high shoulder demand population. Level of Evidence: Level IV, retrospective case series.

  • Open Access

    Full-Construct Biomechanical Evaluation of Femoral Cortical Suspensory Fixation for Anterior Cruciate Ligament Reconstruction in a Porcine Knee Model

    by Tomas F. Vega, Juan Bernardo Villarreal Espinosa, Elizabeth Shewman, Zeeshan A. Khan, Harsh Singh, Brady T. Williams, Thomas Alter, Ron Gilat, Safa Gursoy, Andrew S. Bi, et al.

    Background: Although recent studies show no clinical outcome differences between cortical button suspensory fixation devices for anterior cruciate ligament reconstruction (ACLR), biomechanical mechanisms of elongation and failure remain unclear for adjustable-loop devices (ALDs) and fixed-loop devices (FLDs). Purpose: To compare biomechanical outcomes of ALDs with button-locking device (BLD), suture-locking device (SLD), and dual-locking device (DLD) mechanisms relative to an industry-standard FLD. Study Design: Controlled laboratory study. Methods: Five femoral cortical suspension devices (n = 11 each; total = 55 constructs) were tested using porcine femurs and bovine tendons simulating doubled hamstring grafts: EndoButton (FLD), Infinity Button (BLD), ProCinch (SLD1), UltraButton (SLD2), and TightRope (DLD). Constructs underwent cyclic loading simulating early (10-250 N, 500 cycles) and late (10-400 N, 500 cycles) rehabilitation, followed by pull-to-failure at 50 mm/min. Outcomes included excursion over simulated early and late rehabilitation and the cumulative total of both loading protocols. Also assessed were maximum load, stiffness, energy to failure, and failure mode, categorized as bone, button, suture loop rupture, tendon, or locking mechanism failure. Results: No significant differences were observed in cyclic loading at 500 cycles of 10 to 250 N or across the cumulative 1000 loading cycles between any ALD and the FLD. During cyclic loading at 10 to 400 N specifically, the BLD (3.34 ± 1.71 mm) and DLD (3.63 ± 1.18 mm) demonstrated greater excursion than the FLD (1.49 ± 0.36 mm; both P < .01). SLD1 (1270.5 ± 204.7 N) and SLD2 (1232.7 ± 185.2 N) withstood higher maximum loads than the BLD (1011.4 ± 95.8 N) and DLD (1018.4 ± 63.1 N; P < .05), although no differences were observed between the FLD and all ALDs combined. Stiffness did not differ across groups. BLD and DLD constructs most often failed by suture rupture, whereas the FLD and SLDs failed by button failure. Suture rupture was associated with greater excursion during cyclic loading at 10 to 400 N, lower maximum load, and reduced energy absorption compared with button failure ( P < .05). Conclusion: All constructs exceeded forces expected during early and total rehabilitation after ACLR, confirming adequate initial biomechanical strength across ALDs and FLDs. Differences in excursion and load to failure were associated with locking mechanism design and resultant failure mode, although clinical implications remain uncertain. Clinical Relevance: Although mechanical behavior varied by device mechanism, all systems provided fixation above physiologic loads, supporting that design-specific differences influence how devices fail but not their ability to provide adequate early postoperative stability in ACLR.

  • Open Access

    Editorial Commentary : Chekhov's Unloaded Gun—The Fate of a Knee Cartilage Biopsy Taken in the First Act

    by Tzadok Yona, Ron Gilat

    Matrix‐induced autologous chondrocyte implantation is a well‐established, staged cartilage repair procedure. However, historical data suggests that most patients undergoing the initial index biopsy procedure do not proceed to definitive implantation. Although various predictors for conversion have been proposed, including body mass index, lesion size, defect grade, and surgical history, significant discrepancies persist across the literature. Accurately predicting which patients will convert is critical for 2 primary reasons: first, to minimize unnecessary iatrogenic cartilage damage from nonused biopsies, and second, to mitigate health care waste and optimize resource allocation. Currently, precisely identifying the patient cohorts most likely to undergo implantation remains a clinical challenge, underscoring the need for large‐scale consensus data to guide patient counseling and surgical decision‐making.


  • All‐Inside Meniscus Repair Systems Failure Analysis Shows Device‐Related Adverse Events Differ by Device Design Type and Show Varied Reporting Delays by Manufacturer

    by Tzadok Yona, Bhavya Sheth, Noam Reshef, Ron Gilat

    Purpose: To investigate common failures of all‐inside meniscal repair devices and associated patient injuries and determine whether specific device designs show distinct patterns of adverse events. Methods: The Food and Drug Administration's Manufacturer and User Facility Device Experience database was queried for adverse events involving all‐inside meniscal repair devices from 2023 to 2024. Data collected included device problems, patient injuries, manufacturer details, and time to report incidents. Device problems were categorized into 11 groups: Detachment of Device or Device Component, Failure to Fire, Fracture, Device‐Device Incompatibility, Simultaneous Fire, Premature Activation, Physical Resistance/Sticking, Manufacturing, Packaging or Shipping Problem, Sutures Torn, Material Deformation, and Separation Failure. Statistical analyses included frequency counts, percentages, and Kruskal‐Wallis test, with significance at P  < .05. Results: Three thousand fifty‐six device malfunctions were reported in 2023 to 2024. After excluding 8 nonmeniscal repair devices, 908 duplicates and 84 reports lacking sufficient information, 2056 eligible reports were analyzed. Among these, 114 associated patient injuries (5.5%). The most frequent device problems were Device Detachment (486, 20.76%), Failure to Fire (473, 20.21%), Device Fracture (362, 15.46%), and Device‐Device Incompatibility (346, 14.78%). Reporting delays varied significantly by manufacturer, ranging from a median of 13 to 33.5 days ( P < .001). Reported device problems varied significantly by design group ( P < .001). All‐suture anchors showed the highest rate of Device Fracture (101, 41.6%), whereas rigid capsular‐knot anchors were uniquely associated with Device‐Device Incompatibility (346, 34.0%). Rigid meniscal‐knot anchors predominantly failed due to deployment errors, most notably “Failure to Fire” (391, 36.2%) and “Simultaneous Fire” (215, 19.9%). Conclusions: Adverse event causes differed by system design. All‐suture anchors most frequently failed by Fracture of the device, rigid anchors with a capsular knot showed a unique susceptibility to Device‐Device Incompatibility, and rigid anchors with a meniscal knot were primarily associated with deployment‐related errors. Level of Evidence: Level IV, retrospective comparative cohort.

  • Open Access

    Editorial Commentary : A Call for Clarity—Standardizing Return‐to‐Sport Definitions Is Essential for Interpreting Hip Arthroscopy Outcomes

    by Philip J. Rosinsky, Ron Gilat

    Outcome reporting in sports medicine has become increasingly sophisticated, yet sophistication alone does not ensure clinical usefulness. The value, or utility, of an outcome measure lies in its ability to inform patient expectations, shared decision‐making, and treatment selection. This limitation is particularly evident in the reporting of return‐to‐sport (RTS) outcomes. Differences in RTS definitions can yield substantially different reported success rates without reflecting true differences in surgical effectiveness. For example, defining RTS as return to preinjury competitive level produces markedly lower rates than broader definitions based on any attempted participation. The critical issue is not which definition yields higher RTS rates but which provides greater decision‐making utility for athletes. Because RTS is highly susceptible to external, nonmedical influences, standardized definitions and careful interpretation are essential for meaningful comparison and clinical relevance.

  • Rehabilitation Protocols Following Patellar Instability Surgery: A Structured Review of Published Recommendations and AI Generated Guidance

    by Matias Vidra, Jonathan Sigal, Ilan Y. Mitchnik, Oscar Carvajal Masis, Netanel Krugliak, Gil Rachevsky, Ran Atzmon, Ron Gilat

    To review postoperative rehabilitation protocols after surgery for patellar instability, including medial patellofemoral ligament reconstruction (MPFLR), tibial tubercle osteotomy (TTO), trochleoplasty, and combined procedures. A secondary aim was to compare published recommendations with guidance generated by selected artificial intelligence (AI) platforms. Sixty three protocol entries were included: 35 isolated MPFLR, 9 isolated TTO, 4 isolated trochleoplasty, and 15 combined procedures. Isolated MPFLR showed the most consistent rehabilitation pattern, favoring immediate weight bearing as tolerated (66%, p < 0.001), locked bracing for up to 6 weeks (63%, p < 0.001), and full ROM by 6 to 12 weeks (51%, p = 0.002). Isolated TTO protocols recommended delayed or non weight bearing (56%), locked brace duration greater than 6 weeks (67%), and full ROM by 6 to 12 weeks (44%), with no significant predominance (all p > 0.05). Trochleoplasty protocols were too few and heterogeneous. Combined procedures were mostly protective but variable overall. RTS criteria were mostly time, functional, and strength based (76%-89%), whereas psychological readiness (43%) and physician approval (22%) were infrequent. AI generated protocols broadly reproduced MPFLR rehabilitation principles but lacked procedure specific differentiation. Rehabilitation protocols following patellar instability surgery remain highly variable, particularly for non MPFLR procedures. Isolated MPFLR protocols generally follow a more structured and accelerated pathway, whereas rehabilitation after TTO, trochleoplasty, and combined procedures remains less clearly defined and more protective. RTS decisions rely mainly on time, strength, and functional based criteria, whereas psychological readiness remains underutilized. AI based tools may serve as supportive decision making aids but currently require integration with clinical judgment and procedure-specific expertise.


  • Open Access

    Arthroscopic Microfracture for Focal Glenoid Osteochondral Lesions in Young Active-Duty Military Patients: A Minimum 10-Year Follow-Up

    by Erel Ben-Ari, Clare K. Green, John P. Scanaliato, Alexis B. Sandler, Ron Gilat, John R. Tyler, Nata Parnes

    Background: Glenoid osteochondral defects (OCDs), while uncommon, are a recognized source of shoulder pain and dysfunction, particularly in young, active individuals. Arthroscopic microfracture (MFx) is a commonly used surgical option. However, long-term outcomes remain poorly defined. Purpose: To evaluate long-term clinical and functional outcomes after arthroscopic MFx for focal glenoid OCD in active-duty military patients. Study Design: Case series; Level of evidence, 4. Methods: A retrospective review was conducted of 31 active-duty military patients ( .05). However, all patient-reported outcomes demonstrated statistically significant improvements: VAS (6.84 ± 1.92 to 2.52 ± 2.41), SANE (46.8 ± 20.1 to 81.1 ± 18), and ASES (51.1 ± 14.1 to 82.7 ±17) ( P < .0001 for all). At final follow-up, 68% (21/31) returned to sports and 78% (24/31) resumed unrestricted active military duty. Revision procedures were required in 4 patients (13%): 2 underwent total shoulder arthroplasty, and 2 underwent revision MFx with debridement. MRI detected OCD lesions in only 29% (9/31) of cases. Conclusion: Arthroscopic MFx offers durable pain relief and functional improvement for focal glenoid OCD with concomitant biceps tendinitis, subacromial bursitis, or partial RC tears in high-demand military patients. At a minimum 10-year follow-up, outcomes demonstrated sustained clinical benefits, high return to duty, moderate return to sports (RTS), and low revision rates. Limited MRI sensitivity and prolonged time to surgical treatment highlight the importance of early clinical suspicion and timely surgical intervention in this challenging population.

  • Arthroscopic Posterior Labral Repair of the Shoulder in Active‐Duty Military Patients Shows Improvements in Patient‐Reported Outcomes and High Return to Sports and Military Duty at a Minimum 10 Years Follow‐Up

    by Natasha M. Simske, Alexis B. Sandler, Ron Gilat, John P. Scanaliato, Nitin Jain, John Tyler, Nata Parnes

    Purpose: To evaluate patient‐reported outcome measures (PROMs), clinically significant outcome (CSO) achievement rates, and return to sport (RTS), and military duty (RMD) rates at a minimum of 10 years following arthroscopic posterior labral repair in active‐duty military service members (ADSM). Methods: Consecutive ADSM undergoing arthroscopic posterior labral repair between January 2010 and December 2013 at a single institution with a minimum 10‐year follow‐up were retrospectively evaluated. PROMs assessed included visual analog scale (VAS), American Shoulder and Elbow Surgeons (ASES) score, the Single Assessment Numeric Evaluation (SANE), and the Rowe instability score. CSOs, return to sport, and return to military duty were also collected and assessed. Results: A total of 39 patients met inclusion criteria with an average 140 months (11.7 years, range: 120‐165) of follow‐up. VAS, ASES, SANE, and Rowe scores all improved significantly postoperatively (VAS: 7.9 to 1.7, ASES: 46.7 to 87.8, SANE: 48.1 to 89.1, Rowe: 35.6 to 91.3; P < .0001 for all) at latest follow‐up. All patients achieved the minimal clinically important difference, and the majority (62%‐85%) achieved the patient acceptable symptomatic state for all PROMs. Achievement of substantial clinical benefit varied more considerably than the other measures (31%‐69%). Across all clinical thresholds, a majority of patients (62%‐100%) showed clinically significant improvements in pain as compared to preoperatively. In total, 92.3% (n = 36) of patients showed full return to military duty. Similarly, 87.2% (n = 34) reported return to sport including pushups at final follow‐up. Conclusions: Following arthroscopic posterior labral repair of the shoulder, high‐demand active‐duty military patients sustain significant improvement in PROMs and high CSOs achievement rates at a minimum 10‐year follow‐up, alongside high rates of return to military duty and sports at 92.3% and 87.2%. Level of Evidence: Level IV, retrospective case series.