Peter Heuberger
Research Subjects
Peter Heuberger has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ainara Irastorza-Landa
Nobel Biocare Services AG, Balz-Zimmermann-Str.7, 8302, Kloten, Switzerland
2 shared publications - Baixuan Yang
Queen's University, Mechanical and Materials Engineering, Kingston, ON, Canada
1 shared publication - Cristiano Susin
Department of Periodontology, Endodontics, and Dental Hygiene Adams School of Dentistry University of North Carolina at Chapel Hill Chapel Hill North Carolina USA
1 shared publication - Heidi-Lynn Ploeg
Mechanical and Materials Engineering, Smith Engineering, Queen's University , 130 Stuart St., McLaughlin Hall Rm 303A , Kingston, ON K7L 2VP, Canada
1 shared publication - Stefan Velikov
Nobel Biocare Services AG P.O. Box, CH-8058 Zürich-Flughafen, Switzerland
1 shared publication
Latest Publications
- 1 December 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 112, 103995
Effect of insertion factors on dental implant insertion torque/energy-experimental results
- 1 December 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 112, 103995
Effect of insertion factors on dental implant insertion torque/energy-experimental results
- Open Access
- 11 February 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (2) , 494
A New Site Preparation Protocol That Supports Bone Quality Evaluation and Provides Predictable Implant Insertion Torque
When preparing an implant site, clinicians often base their assessment of the bone on subjective tactile and visual cues. This assessment is used to plan the surgical procedure for site preparation, including how many drilling steps will be used. The subjective nature of bone evaluation, consequently, results in poor reproducibility and may lead to under or over preparation of the site. Recently, an unconventional site preparation protocol was developed in which the decision of which instruments to use is dictated by insertion torque of the novel site preparation instrument (OsseoShaper™, Nobel Biocare AB, Gothenburg, Sweden). The aim of this study was to quantify the correlation of the site preparation torques of the new instrument with bone density and maximum implant insertion torques. In vitro and in vivo data showed strong linear correlation between site preparation torque and density and resulted in reliable implant insertion torques, respectively. From our analysis, we conclude that this new instrument and protocol has the potential to eliminate the need for additional intraoperative bone evaluation and may reduce the risk of inadequate preparation of the site due to the ability to serve as a predictor of the final implant insertion torque.
- 11 February 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (2) , 494
Open AccessA New Site Preparation Protocol That Supports Bone Quality Evaluation and Provides Predictable Implant Insertion Torque
When preparing an implant site, clinicians often base their assessment of the bone on subjective tactile and visual cues. This assessment is used to plan the surgical procedure for site preparation, including how many drilling steps will be used. The subjective nature of bone evaluation, consequently, results in poor reproducibility and may lead to under or over preparation of the site. Recently, an unconventional site preparation protocol was developed in which the decision of which instruments to use is dictated by insertion torque of the novel site preparation instrument (OsseoShaper™, Nobel Biocare AB, Gothenburg, Sweden). The aim of this study was to quantify the correlation of the site preparation torques of the new instrument with bone density and maximum implant insertion torques. In vitro and in vivo data showed strong linear correlation between site preparation torque and density and resulted in reliable implant insertion torques, respectively. From our analysis, we conclude that this new instrument and protocol has the potential to eliminate the need for additional intraoperative bone evaluation and may reduce the risk of inadequate preparation of the site due to the ability to serve as a predictor of the final implant insertion torque.