SXShimin Xue

Shimin Xue

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shimin Xue has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A current‐limiting DC circuit breaker with power flow control capability

    by Shimin Xue, Xiao Chen, Baibing Liu, Wenjie Chen, Botong Li, Bin Li

    Power flow controller (PFC), fault current limiter (FCL) and DC circuit breaker (DCCB) are important equipment in the DC grid. There are a large number of power electronic components in these equipment, resulting in high cost. In order to reduce the use of additional components, a current‐limiting DC circuit breaker with power flow control capability is proposed here, which integrates the PFC, FCL, and DCCB into one equipment. Further, the main breaker in the proposed circuit breaker is shared by all lines connected to a DC bus to reduce cost. The topology and operating principle of the circuit breaker are introduced. Theoretical analysis and parameter design are carried out. Besides, the proposed circuit breaker is verified in PSCAD/EMTDC. Finally, the performance and cost are compared with existing schemes. The simulation results show that the proposed circuit breaker can effectively realize power flow control, current limiting and fault isolation at a lower cost.


  • Open Access

    Research on the protection scheme of MMC‐MTDC based on high frequency energy

    by Shimin Xue, Shuo Chen, Yabing Sun, Cheng Gu, Baibing Liu

    The development of flexible HVDC transmission technology requires the improvement of the theory of relay protections. The protection method based on the time domain has poor resistance to transition resistance and is easily affected by interference factors. The protection based on frequency domain analysis can better reflect the essential characteristics of the fault, and it is also an urgent problem for relay protections. The blocking effect of boundary elements on both sides of the line on high‐frequency components is an important entry point for current protection research, but high‐frequency protections are very sensitive to noise signals. Therefore, this paper analyses the frequency characteristics of the voltage at the measuring point from the perspective of the traveling wave transmission process, and uses the S transform to design a protection method based on high‐frequency energy to realize the identification of internal and external faults. Finally, the ability to withstand transition resistance and anti‐noise of the protection proposed here is verified by using PSCAD/EMTDC. The protection can complete fault identification within 2 ms, which means that it has both reliability and quick action.


  • Open Access

    Analysis and Protection Scheme of Station Internal AC Grounding Faults in a Bipolar MMC-HVDC System

    by Shimin Xue, Cheng Gu, Baibing Liu, Boyang Fan

    The symmetrical bipolar configuration shows a great advantage in modular multilevel converter (MMC) based high-voltage dc-current (HVDC) transmission. In a bipolar MMC-HVDC system, station internal ac grounding faults cause sub-module (SM) capacitors to discharge violently. These faults do great harm to MMCs and require special protection schemes. In this paper, a single-phase-to-ground fault is taken as an example to investigate transient characteristics of station internal ac grounding faults in a bipolar MMC-HVDC system. A calculation theory of fault current based on the improving RLC model and second-order differential equation with variable coefficients is introduced. A novel transient zero-mode current based protection criterion with better reliably, quickness, and ability to endure fault resistances is proposed to detect internal ac grounding faults. The fault clearing strategy applicable to three types of grounding faults is also designed. The correctness of the proposed calculation theory and protection schemes is verified through simulations performed in PSCAD/EMTDC.


  • Research on an Improved Protection Principle Based on Differential Voltage Traveling Wave for VSC-HVDC Transmission Lines

    by Botong Li, Mingrui Lv, Bin Li, Shimin Xue, Weijie Wen

    When a short-circuit fault occurs in the VSC-HVDC transmission system, the DC-side current increases and the voltage decreases rapidly, which can pose a serious threat to the normal operation of the system. In order to meet the requirements for speed, selectivity, sensitivity and reliability of the VSC-HVDC transmission system, the propagating characteristics of voltage traveling wave after a fault occurs in the VSC-HVDC transmission line are analyzed, and then an improved protection principle based on the differential voltage traveling wave considering the frequency-dependent line parameters is proposed. A data out-of-sync detection method only using the electrical quantities on both ends of the line is studied to prevent the protection from mal-operating when there is something wrong with the synchronization clocks. The causes of operation delay are further analyzed and the delay time is estimated for determining the possible application of the protection scheme. Finally, correctness of the protection principle and relevant algorithms are verified by the combination of MATLAB-based protection program and PSCAD-based simulations.


  • A Staged Current Limiting Scheme of Hybrid DC Circuit Breaker for HVDC Grid

    by Baibing Liu, Shimin Xue, Shouxiang Wang, Yabing Sun, Xu Cai

    Several half-bridge modular multilevel converter (HB-MMC) HVDC projects have been put into operation in recent years. When the DC side faults, the sharp rise current will easily cause the damage of the converters. This paper proposes a new staged current-limiting HVDC circuit breaker (DCCB) scheme, which is based on the existing hybrid DCCB. The new scheme can not only put into current-limiting quickly after the fault but also maintain current-limiting for a period, which reserves enough time for DC protection judgment. Meanwhile, it can reduce the difficulty of DCCB to cut off the fault line through self-bypass design. The feasibility and validity of the proposed scheme are verified to be applicable for HVDC fault isolation requirements by PSCAD/EMTDC simulation results.


  • Open Access

    A Novel Single-Terminal Fault Location Method for AC Transmission Lines in a MMC-HVDC-Based AC/DC Hybrid System

    by Shimin Xue, Junchi Lu, Chong Liu, Yabing Sun, Baibing Liu, Cheng Gu

    Accurate and reliable fault location method for alternating current (AC) transmission lines is essential to the fault recovery. MMC-based converter brings exclusive non-linear characteristics to AC networks under single-phase-to-ground faults, thus influencing the performance of the fault location method. Fault characteristics are related to the control strategies of the converter. However, the existing fault location methods do not take the control strategies into account, with further study being required to solve this problem. The influence of the control strategies to the fault compound sequence network is analyzed in this paper first. Then, a unique boundary condition that the fault voltage and negative-sequence fault current merely meet the direct proportion linear relationship at the fault point, is derived. Based on these, a unary linear regression analysis is performed, and the fault can be located according to the minimum residual sum function principle. The effectiveness of the proposed method is verified by PSCAD/EMTDC simulation platform. A large number of simulation results are used to verify the advantages on sampling frequency, fault resistance, and fault distance. More importantly, it provides a higher ranging precision and has extensive applicability.


  • A criterion for non‐voltage directional elements applied in AC networks connected with VSC‐based interconnection devices

    by Shimin Xue, Zhe Shi, Renle Huang, Qiankun Chang, Junchi Lu, Jingyue Yang

    The application of voltage source converter (VSC)‐based interconnection devices or distributed generators (DGs) in an AC distribution system makes the network change from a single‐terminal power supply network to a multi‐terminal power supply network. However, traditional three‐section current protection applied in AC distribution networks is not capable of identifying the direction of the fault, and therefore it is necessary to install directional elements to ensure the reliability of the three‐section current protection. The phase relationships among negative‐sequence currents under phase‐to‐phase faults that happen at different locations in the AC distribution network connected with back‐to‐back VSC‐based interconnection device are derived first in this paper. Then a novel criterion based on the phase relationships among the negative‐sequence currents flowing through the protected line and the other two branches emanating from the same bus is proposed for fault direction identification. The proposed directional criterion is applicable to multi‐terminal power supply networks containing VSC‐based interconnection devices or VSC‐interfaced DGs, with three or more branches emanating from each bus. The proposed directional criterion does not require potential transformers (PTs), and is hardly affected by transient resistance. Under a symmetrical fault, negative‐sequence current can be obtained by delaying the filtering data window of any one of three phases, and the dead zone of traditional directional elements when the fault happens at the outlet of the relay can be avoided. The validity of the proposed criterion is verified by several PSCAD simulation results. © 2018 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.


  • Open Access

    Line-to-Line Fault Analysis and Location in a VSC-Based Low-Voltage DC Distribution Network

    by Shi-Min Xue, Chong Liu

    A DC cable short-circuit fault is the most severe fault type that occurs in DC distribution networks, having a negative impact on transmission equipment and the stability of system operation. When a short-circuit fault occurs in a DC distribution network based on a voltage source converter (VSC), an in-depth analysis and characterization of the fault is of great significance to establish relay protection, devise fault current limiters and realize fault location. However, research on short-circuit faults in VSC-based low-voltage DC (LVDC) systems, which are greatly different from high-voltage DC (HVDC) systems, is currently stagnant. The existing research in this area is not conclusive, with further study required to explain findings in HVDC systems that do not fit with simulated results or lack thorough theoretical analyses. In this paper, faults are divided into transient- and steady-state faults, and detailed formulas are provided. A more thorough and practical theoretical analysis with fewer errors can be used to develop protection schemes and short-circuit fault locations based on transient- and steady-state analytic formulas. Compared to the classical methods, the fault analyses in this paper provide more accurate computed results of fault current. Thus, the fault location method can rapidly evaluate the distance between the fault and converter. The analyses of error increase and an improved handshaking method coordinating with the proposed location method are presented.


  • Open Access

    Pole-to-Ground Fault Analysis and Fast Protection Scheme for HVDC Based on Overhead Transmission Lines

    by Shimin Xue, Jie Lian, Jinlong Qi, Boyang Fan

    Flexible direct current (DC) transmission network technology is an effective method for large capacity clean energy access to power grids, but the DC short-circuit fault detection for it is a difficult problem. In this paper, the pole-to-ground fault transient characteristics in a multi-terminal DC power grid, based on overhead transmission lines and DC circuit breakers, are analyzed firstly. Then, a fast protection scheme is proposed according to the fault transient characteristics. Only local information is utilized for fault detection and location in the proposed scheme. Moreover, the scheme is verified to have the advantages of fast action speed, high reliability and the ability to resist the transition resistance. A four terminal DC power grid model based on actual engineering parameters is established in PSCAD/EMTDC, and the validity of the protection scheme under different fault conditions is verified by simulation results.


  • Open Access

    Study on the Current-Limiting-Capable Control Strategy for Grid-Connected Three-Phase Four-Leg Inverter in Low-Voltage Network

    by Botong Li, Jianfei Jia, Shimin Xue

    The three-phase four-leg inverter can produce balanced voltages even with unbalanced loads, yet its controller design is quite complicated. Based on the analysis on time domain equations, a decoupled sequence control strategy for the three-phase four-leg inverter in a low-voltage network is proposed. A negative sequence controller and a zero sequence controller are added to the control strategy besides the positive sequence controller. Furthermore, considering the output limit of the inverter, a current limit design scheme is raised through the analysis on each sequence current in synchronous rotating frame. In the case of asymmetry, the limit value of each sequence current can be adjusted dynamically according to the design scheme. The output currents in each sequence can be controlled and limited for different purposes respectively. Finally, simulation results based on PSCAD/EMTDC V4.5.0 verify the validity of the control strategy.