Christopher Söderberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Christopher Söderberg has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ana Labrador
MaxIV Laboratory, SE 224 84 Lund, Sweden
1 shared publication - Christian Grundahl Frankær
Department of Chemistry, University of Copenhagen, Universitetsparken 5, 2100 København Ø, Denmark
1 shared publication - Günther Herbert Johannes Peters
Technical University of Denmark
1 shared publication - Jens Thostrup Bukrinsky
CMC Assist Aps, DK-2500 Copenhagen, Denmark
1 shared publication - Pernille Harris
Department of Chemistry, Faculty of Science, University of Copenhagen, Copenhagen, Denmark
1 shared publication - Pernille Sønderby
Department of Chemistry, Technical University of Denmark, Kemitorvet B207, DK-2800 Kgs Lyngby, Denmark
1 shared publication
Latest Publications
- 12 February 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (2) , 396-404
Concentrated protein solutions investigated using acoustic levitation and small-angle X-ray scattering
An acoustically levitated droplet has been used to collect synchrotron SAXS data on human serum albumin protein solutions up to a protein concentration of 400 mg ml−1. A careful selection of experiments allows for fast data collection of a large amount of data, spanning a protein concentration/solvent concentration space with limited sample consumption (down to 3 µL per experiment) and few measurements. The data analysis shows data of high quality that are reproducible and comparable with data from standard flow-through capillary-based experiments. Furthermore, using this methodology, it is possible to achieve concentrations that would not be accessible by conventional cells. The protein concentration and ionic strength parameter space diagram may be covered easily and the amount of protein sample is significantly reduced (by a factor of 100 in this work). Used in routine measurements, the benefits in terms of protein cost and time spent are very significant.
- 12 February 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (2) , 396-404
Concentrated protein solutions investigated using acoustic levitation and small-angle X-ray scattering
An acoustically levitated droplet has been used to collect synchrotron SAXS data on human serum albumin protein solutions up to a protein concentration of 400 mg ml−1. A careful selection of experiments allows for fast data collection of a large amount of data, spanning a protein concentration/solvent concentration space with limited sample consumption (down to 3 µL per experiment) and few measurements. The data analysis shows data of high quality that are reproducible and comparable with data from standard flow-through capillary-based experiments. Furthermore, using this methodology, it is possible to achieve concentrations that would not be accessible by conventional cells. The protein concentration and ionic strength parameter space diagram may be covered easily and the amount of protein sample is significantly reduced (by a factor of 100 in this work). Used in routine measurements, the benefits in terms of protein cost and time spent are very significant.