Lesheng Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lesheng Huang has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Tianzhu Liu
Department of Radiology, Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai, China
8 shared publications - Wanchun Zhang
Guangdong Hospital of Traditional Chinese Medicine, Department of Radiology, Zhuhai, China
4 shared publications - Jiahui Tang
Guangdong Hospital of Traditional Chinese Medicine, Department of Radiology, Zhuhai, China
3 shared publications - Jun Chen
Department of Radiology, Guangdong Provincial Hospital of Chinese Medicine, Zhuhai, China
3 shared publications - Se Peng
Guangdong Hospital of Traditional Chinese Medicine, Department of Laboratory, Zhuhai, China
3 shared publications - Xiaodan Li
Department of Gynaecology, Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai519000, China
3 shared publications
Latest Publications
- Open Access
- 10 November 2026
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
Fusion of segmental right-lobe IVIM-DWI metrics and GPR for non-invasive assessment of chronic hepatitis B–related hepatic fibrosis: a pilot study
PURPOSE A segmental intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI)/gamma-glutamyl transpeptidase-to-platelet ratio (GPR) fusion model was evaluated for the non-invasive assessment of chronic hepatitis B (CHB) fibrosis (controls vs. early; early vs. advanced) and compared with…
- 10 November 2026
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
Open AccessFusion of segmental right-lobe IVIM-DWI metrics and GPR for non-invasive assessment of chronic hepatitis B–related hepatic fibrosis: a pilot study
PURPOSE A segmental intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI)/gamma-glutamyl transpeptidase-to-platelet ratio (GPR) fusion model was evaluated for the non-invasive assessment of chronic hepatitis B (CHB) fibrosis (controls vs. early; early vs. advanced) and compared with…
- 15 January 2026
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 22
Field-of-View Optimized and Constrained Undistorted Single-Shot Study of Diffusion-Weighted Imaging and Intravoxel Incoherent Motion for the Uterus and Cervix in Females of Childbearing Age and Postmenopause: A Prospective Study
Introduction: The female reproductive system undergoes hormone-driven cyclical changes during the menstrual cycle and further alterations after menopause. However, the impact of these changes on imaging parameters remains unclear. This study aimed to compare diffusion-weighted imaging and intravoxel incoherent motion (DWI-IVIM) parameters of the uterus and cervix in women of childbearing age across different menstrual phases and in postmenopausal women. Methods: This prospective study was conducted from January 2022 to January 2024. Routine pelvic MRI and DWI-IVIM scans were performed in women of childbearing age during the menstrual phase (MP), follicular phase (FP), and luteal phase (LP), and at any time in postmenopausal women. Intraclass correlation coefficients (ICCs) were used to assess intra- and inter-observer repeatability of DWI-IVIM parameters. Results: Repeatability analysis demonstrated excellent intra- and inter-observer agreement for ADC, good agreement for D and f, and poor agreement for D* values. Compared with postmenopausal women, endometrial ADC, D, and D* values were significantly lower during the MP (ADC: p < 0.001; D: p = 0.003; D*: p = 0.007), while f values exhibited a non-significant downward trend (p = 0.09). No significant differences in DWI-IVIM parameters were observed in the uterine junctional zone across menstrual phases. In the myometrium, ADC values were significantly higher during the FP compared with postmenopause (p = 0.006). Cervical ADC, D, and f values were significantly higher across all menstrual phases than in postmenopausal women (ADC: MP/FP/LP p < 0.001; D: MP/FP p < 0.001, LP p = 0.02; f: MP/FP p < 0.001, LP p = 0.003), whereas D* values were significantly lower during all menstrual phases compared with postmenopause (MP/FP p < 0.001, LP p = 0.005). Conclusion: DWI-IVIM parameters can detect physiological differences in the uterus and cervix between menstrual phases and postmenopause. These findings underscore the importance of considering hormonal and physiological variability when interpreting imaging studies of the female reproductive system. Further research is warranted to explore the diagnostic implications of these parameters.
- 15 January 2026
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 22
Field-of-View Optimized and Constrained Undistorted Single-Shot Study of Diffusion-Weighted Imaging and Intravoxel Incoherent Motion for the Uterus and Cervix in Females of Childbearing Age and Postmenopause: A Prospective Study
Introduction: The female reproductive system undergoes hormone-driven cyclical changes during the menstrual cycle and further alterations after menopause. However, the impact of these changes on imaging parameters remains unclear. This study aimed to compare diffusion-weighted imaging and intravoxel incoherent motion (DWI-IVIM) parameters of the uterus and cervix in women of childbearing age across different menstrual phases and in postmenopausal women. Methods: This prospective study was conducted from January 2022 to January 2024. Routine pelvic MRI and DWI-IVIM scans were performed in women of childbearing age during the menstrual phase (MP), follicular phase (FP), and luteal phase (LP), and at any time in postmenopausal women. Intraclass correlation coefficients (ICCs) were used to assess intra- and inter-observer repeatability of DWI-IVIM parameters. Results: Repeatability analysis demonstrated excellent intra- and inter-observer agreement for ADC, good agreement for D and f, and poor agreement for D* values. Compared with postmenopausal women, endometrial ADC, D, and D* values were significantly lower during the MP (ADC: p < 0.001; D: p = 0.003; D*: p = 0.007), while f values exhibited a non-significant downward trend (p = 0.09). No significant differences in DWI-IVIM parameters were observed in the uterine junctional zone across menstrual phases. In the myometrium, ADC values were significantly higher during the FP compared with postmenopause (p = 0.006). Cervical ADC, D, and f values were significantly higher across all menstrual phases than in postmenopausal women (ADC: MP/FP/LP p < 0.001; D: MP/FP p < 0.001, LP p = 0.02; f: MP/FP p < 0.001, LP p = 0.003), whereas D* values were significantly lower during all menstrual phases compared with postmenopause (MP/FP p < 0.001, LP p = 0.005). Conclusion: DWI-IVIM parameters can detect physiological differences in the uterus and cervix between menstrual phases and postmenopause. These findings underscore the importance of considering hormonal and physiological variability when interpreting imaging studies of the female reproductive system. Further research is warranted to explore the diagnostic implications of these parameters.
- Open Access
- 1 September 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (5) , 656-663
Field-of-view optimized and constrained undistorted single-shot study of intravoxel incoherent motion and diffusion-weighted imaging of the uterus during the menstrual cycle: a prospective study
PURPOSE This study aimed to compare the variability of the uterus during the menses phase (MP), follicular phase (FP), and luteal phase (LP) of the menstrual cycle using intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI). METHODS This prospective study was conducted at the Guangdong Provincial Hospital of Traditional Chinese Medicine between January 2022 and January 2023. Women of childbearing age (18-45 years) with appropriate progesterone levels were included in this study. Conventional magnetic resonance imaging and IVIM-DWI scans were performed during the MP, FP, and LP. The differences in IVIM-DWI- derived parameters between these phases were then compared, and the overlap was quantitatively described. RESULTS The apparent diffusion coefficient (ADC) and pure molecular diffusion coefficient (D) values from the endometrium, uterine junctional zone (UJZ), and myometrium indicated statistical differences between the MP and FP and the MP and LP (ADC: endometrium, both P < 0.001; UJZ, P = 0.008 and P < 0.001, respectively; myometrium, P = 0.033 and P = 0.006, respectively; D: endometrium, both P < 0.001; UJZ, P = 0.008 and P = 0.006, respectively; myometrium, P = 0.041 and P = 0.045, respectively). The perfusion-related diffusion coefficient (D*) values from the myometrium indicated statistical differences between the FP and MP and the FP and LP (D*: myometrium, P = 0.049 and P = 0.009, respectively). The overlapping endometrium ratios between the MP and FP or LP were lower than 50% in the ADC and D values (ADC: overlapping of MP and FP: 33.33%, overlapping of MP and LP: 23.33%; D: overlapping of MP and FP: 40.00%, overlapping of MP and LP: 43.33%). CONCLUSION The ADC and IVIM-derived parameters indicated differences in the uterus in diverse phases of the menstrual cycle, especially in the endometrium in relation to ADC and D values.
- 1 September 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (5) , 656-663
Open AccessField-of-view optimized and constrained undistorted single-shot study of intravoxel incoherent motion and diffusion-weighted imaging of the uterus during the menstrual cycle: a prospective study
PURPOSE This study aimed to compare the variability of the uterus during the menses phase (MP), follicular phase (FP), and luteal phase (LP) of the menstrual cycle using intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI). METHODS This prospective study was conducted at the Guangdong Provincial Hospital of Traditional Chinese Medicine between January 2022 and January 2023. Women of childbearing age (18-45 years) with appropriate progesterone levels were included in this study. Conventional magnetic resonance imaging and IVIM-DWI scans were performed during the MP, FP, and LP. The differences in IVIM-DWI- derived parameters between these phases were then compared, and the overlap was quantitatively described. RESULTS The apparent diffusion coefficient (ADC) and pure molecular diffusion coefficient (D) values from the endometrium, uterine junctional zone (UJZ), and myometrium indicated statistical differences between the MP and FP and the MP and LP (ADC: endometrium, both P < 0.001; UJZ, P = 0.008 and P < 0.001, respectively; myometrium, P = 0.033 and P = 0.006, respectively; D: endometrium, both P < 0.001; UJZ, P = 0.008 and P = 0.006, respectively; myometrium, P = 0.041 and P = 0.045, respectively). The perfusion-related diffusion coefficient (D*) values from the myometrium indicated statistical differences between the FP and MP and the FP and LP (D*: myometrium, P = 0.049 and P = 0.009, respectively). The overlapping endometrium ratios between the MP and FP or LP were lower than 50% in the ADC and D values (ADC: overlapping of MP and FP: 33.33%, overlapping of MP and LP: 23.33%; D: overlapping of MP and FP: 40.00%, overlapping of MP and LP: 43.33%). CONCLUSION The ADC and IVIM-derived parameters indicated differences in the uterus in diverse phases of the menstrual cycle, especially in the endometrium in relation to ADC and D values.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Repeatability and reliability of intravoxel incoherent motion derived parameters in evaluation of liver heterogeneity
This study aimed to investigate the repeatability and reliability of IVIM derived parameters in evaluation of liver heterogeneity. Patients with early liver fibrosis and healthy subjects were recruited and underwent MRI using respiratory triggered SS-DWI with 12 b values and an IDEAL-IQ sequence. Two readers independently analyzed liver segment data using mono-exponential, bi-exponential and stretched exponential models. CVs and ICCs were calculated before and after the exclusion of subjects with potential liver fat deposition. ADC, D and α measurements of right liver lobe were satisfactorily repeatable, regardless of fat deposition. Segment-VII and -VIII values may be more repeatable and reliable.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Repeatability and reliability of intravoxel incoherent motion derived parameters in evaluation of liver heterogeneity
This study aimed to investigate the repeatability and reliability of IVIM derived parameters in evaluation of liver heterogeneity. Patients with early liver fibrosis and healthy subjects were recruited and underwent MRI using respiratory triggered SS-DWI with 12 b values and an IDEAL-IQ sequence. Two readers independently analyzed liver segment data using mono-exponential, bi-exponential and stretched exponential models. CVs and ICCs were calculated before and after the exclusion of subjects with potential liver fat deposition. ADC, D and α measurements of right liver lobe were satisfactorily repeatable, regardless of fat deposition. Segment-VII and -VIII values may be more repeatable and reliable.
- Open Access
- 2 January 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 30 (4) , 236-247
Cystic renal mass screening: machine-learning-based radiomics on unenhanced computed tomography
The present study compares the diagnostic performance of unenhanced computed tomography (CT) radiomics-based machine learning (ML) classifiers and a radiologist in cystic renal masses (CRMs). Patients with pathologically diagnosed CRMs from two hospitals were enrolled in the study. Unenhanced CT radiomic features were extracted for ML modeling in the training set (Guangzhou; 162 CRMs, 85 malignant). Total tumor segmentation was performed by two radiologists. Features with intraclass correlation coefficients of >0.75 were screened using univariate analysis, least absolute shrinkage and selection operator, and bidirectional elimination to construct random forest (RF), decision tree (DT), and k-nearest neighbor (KNN) models. External validation was performed in the Zhuhai set (45 CRMs, 30 malignant). All images were assessed by a radiologist. The ML models were evaluated using calibration curves, decision curves, and receiver operating characteristic (ROC) curves. Of the 207 patients (102 women; 59.1 ± 11.5 years), 92 (41 women; 58.0 ± 13.7 years) had benign CRMs, and 115 (61 women; 59.8 ± 11.4 years) had malignant CRMs. The accuracy, sensitivity, and specificity of the radiologist's diagnoses were 85.5%, 84.2%, and 91.1%, respectively [area under the (ROC) curve (AUC), 0.87]. The ML classifiers showed similar sensitivity (94.2%-100%), specificity (94.7%-100%), and accuracy (94.3%-100%) in the training set. In the validation set, KNN showed better sensitivity, accuracy, and AUC than DT and RF but weaker specificity. Calibration and decision curves showed excellent and good results in the training and validation set, respectively. Unenhanced CT radiomics-based ML classifiers, especially KNN, may aid in screening CRMs.
- 2 January 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 30 (4) , 236-247
Open AccessCystic renal mass screening: machine-learning-based radiomics on unenhanced computed tomography
The present study compares the diagnostic performance of unenhanced computed tomography (CT) radiomics-based machine learning (ML) classifiers and a radiologist in cystic renal masses (CRMs). Patients with pathologically diagnosed CRMs from two hospitals were enrolled in the study. Unenhanced CT radiomic features were extracted for ML modeling in the training set (Guangzhou; 162 CRMs, 85 malignant). Total tumor segmentation was performed by two radiologists. Features with intraclass correlation coefficients of >0.75 were screened using univariate analysis, least absolute shrinkage and selection operator, and bidirectional elimination to construct random forest (RF), decision tree (DT), and k-nearest neighbor (KNN) models. External validation was performed in the Zhuhai set (45 CRMs, 30 malignant). All images were assessed by a radiologist. The ML models were evaluated using calibration curves, decision curves, and receiver operating characteristic (ROC) curves. Of the 207 patients (102 women; 59.1 ± 11.5 years), 92 (41 women; 58.0 ± 13.7 years) had benign CRMs, and 115 (61 women; 59.8 ± 11.4 years) had malignant CRMs. The accuracy, sensitivity, and specificity of the radiologist's diagnoses were 85.5%, 84.2%, and 91.1%, respectively [area under the (ROC) curve (AUC), 0.87]. The ML classifiers showed similar sensitivity (94.2%-100%), specificity (94.7%-100%), and accuracy (94.3%-100%) in the training set. In the validation set, KNN showed better sensitivity, accuracy, and AUC than DT and RF but weaker specificity. Calibration and decision curves showed excellent and good results in the training and validation set, respectively. Unenhanced CT radiomics-based ML classifiers, especially KNN, may aid in screening CRMs.
- Open Access
- 1 September 2020
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 51 (3) , 503-504
Potential Infection Risk Control in the Radiology Department during Economic Recovery after the COVID-19 Pandemic
- 1 September 2020
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 51 (3) , 503-504
Open AccessPotential Infection Risk Control in the Radiology Department during Economic Recovery after the COVID-19 Pandemic
- 1 April 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 295 (1) , 22-23
Use of Chest CT in Combination with Negative RT-PCR Assay for the 2019 Novel Coronavirus but High Clinical Suspicion
- 1 April 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 295 (1) , 22-23
Use of Chest CT in Combination with Negative RT-PCR Assay for the 2019 Novel Coronavirus but High Clinical Suspicion
- 1 February 2020
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 2 (1) , e200025
Spectrum of Chest CT Findings in a Familial Cluster of COVID-19 Infection
- 1 February 2020
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 2 (1) , e200025
Spectrum of Chest CT Findings in a Familial Cluster of COVID-19 Infection