RBReginald Birngruber

Reginald Birngruber

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Reginald Birngruber has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optical coherence tomography needle probe for real-time visualization of temperature-induced phase changes within subcutaneous fatty tissue

    by Hinnerk Schulz-Hildebrandt, Michael Wang-Evers, Naja Meyer-Schell, Daniel Karasik, Malte J. Casper, Tim Eixmann, Felix Hilge, Reginald Birngruber, Dieter Manstein, Gereon Hüttmann

    Selective cryolipolysis has been developed as a noninvasive method of reducing subcutaneous fat without damaging the skin.1 Since its FDA clearance in 2010, selective cryolipolysis, commercially known as CoolSculpting®, has become a popular clinical procedure for noninvasive fat removal. It serves as an alternative to invasive fat removal procedures such as liposuction. Due to its noninvasiveness, there is virtually no patient downtime, and it eliminates many of the risks of surgical interventions, including scarring, infection, necrosis, and even death.2 Furthermore, it provides an attractive option for localized removal of fatty tissue. Diet and exercise are generally seen as methods to reduce fatty tissue, but those have their challenges and generally do not allow reducing fatty tissue in localized, targeted areas such as the flanks or the upper arms. Selective cryolipolysis involves controlled and precise localized cooling of adipose fat through the skin. It is believed that the mechanism of fat reduction involves cooling-induced crystallization of the lipids in the adipocytes, which is known to occur above the temperature of water freezing. For a few weeks post procedure, a localized inflammatory response induced by fat crystallization results in apoptosis and necrosis of the adipocytes and, ultimately, a partial loss of fatty tissue. This is largely achieved without damage to the dermis or epidermis, even though cooling is applied to the skin surface. Dermal and epidermal tissues have a higher water content and are less sensitive to cold than adipose tissue.3 In addition, a glycerol-based antifreeze is topically applied to the skin to further protect the epidermis from freeze injury. Thus, the inflammatory response is located exclusively in adipose tissue. Although selective cryolipolysis is generally considered a safe treatment, some clinical trials have reported various side effects of the treatment, including erythema, edema, bruising, and transient neuralgia.4 Paradoxical adipose hyperplasia, which presents as a delayed, localized increase in fatty tissue volume, has also been presented as a relatively rare adverse effect. Despite5,6 these risks, selective cryolipolysis has become a market success with widespread use in dermatological clinics, with more than 10 million treatments performed at the time of this paper being published. However, the results of treatment can differ from person to person, as various factors, including gender, diet, and hormonal balance, impact the local lipid composition and therefore the crystallization temperature of the fat of the person.7,8 As adipocyte crystallization is considered an important factor for cold-induced adipocyte damage, a method for imaging the formation of crystallization of adipocytes during cryolipolysis can provide important insights and help to improve the treatment conditions (e.g., temperature, duration, skin contact, and applicator geometry) to achieve better outcome. In addition, it will help to improve the biological understanding of cryolipolysis, allowing further exploration of the effects of various diets, repeated treatments, and other factors on the efficacy of the procedure.


  • Open Access

    Correction of hyperopia by intrastromal cutting and liquid filler injection

    by Sebastian Freidank, Alfred Vogel, Richard R. Anderson, Reginald Birngruber, Norbert Linz

    Correction of hyperopia requires an increase of the refractive power by steepening of the corneal surface. Present refractive surgical techniques based on corneal ablation (LASIK) or intrastromal lenticule extraction (SMILE) are problematic due to epithelial regrowth. Recently, it was shown that correction of low hyperopia can be achieved by implanting intracorneal inlays or allogeneic lenticules. We demonstrate a steepening of the anterior corneal surface after injection of a transparent, liquid filler material into a laser-dissected intrastromal pocket. We performed the study on ex-vivo porcine eyes. The increase of the refractive power was evaluated by optical coherence tomography (OCT). For a circular pocket, injection of 1 μl filler material increased the refractive power by +4.5 diopters. An astigmatism correction is possible when ellipsoidal intrastromal pockets are created. Injection of 2 μl filler material into an ellipsoidal pocket increased the refractive power by +10.9 dpt on the short and +5.1 dpt on the long axis. OCT will enable to monitor the refractive change during filler injection and is thus a promising technique for real-time dosimetry.


  • Open Access

    Optimization-based vessel segmentation pipeline for robust quantification of capillary networks in skin with optical coherence tomography angiography

    by Malte Casper, Hinnerk Schulz-Hildebrandt, Michael Evers, Reginald Birngruber, Dieter Manstein, Gereon Hüttmann

    Optical coherence tomography angiography (OCTA) provides in-vivo images of microvascular perfusion in high resolution. For its application to basic and clinical research, an automatic and robust quantification of the capillary architecture is mandatory. Only this makes it possible to reliably analyze large amounts of image data, to establish biomarkers, and to monitor disease developments. However, due to its optical properties, OCTA images of skin often suffer from a poor signal-to-noise ratio and contain imaging artifacts. Previous work on automatic vessel segmentation in OCTA mostly focuses on retinal and cerebral vasculature. Its applicability to skin and, furthermore, its robustness against imaging artifacts had not been systematically evaluated. We propose a segmentation method that improves the quality of vascular quantification in OCTA images even if corrupted by imaging artifacts. Both the combination of image processing methods and the choice of their parameters are systematically optimized to match the manual labeling of an expert for OCTA images of skin. The efficacy of this optimization-based vessel segmentation is further demonstrated on sample images as well as by a reduced error of derived quantitative vascular network characteristics.


  • Selective retina therapy: toward an optically controlled automatic dosing

    by Eric Seifert, Jan Tode, Amelie Pielen, Dirk Theisen-Kunde, Carsten Framme, Johann Roider, Yoko Miura, Reginald Birngruber, Ralf Brinkmann

    The Journal of Biomedical Optics (JBO) publishes peer-reviewed papers on the use of novel optical systems and techniques for improved health care and biomedical research.


  • Power-controlled temperature guided retinal laser therapy

    by Alexander Baade, Claus Von Der Burchard, Meike Lawin, Stefan Koinzer, Benedikt Schmarbeck, Kerstin Schlott, Yoko Miura, Johann Roider, Reginald Birngruber, Ralf Brinkmann

    Laser photocoagulation has been a treatment method for retinal diseases for decades. Recently, studies have demonstrated therapeutic benefits for subvisible effects. A treatment mode based on an automatic feedback algorithm to reliably generate subvisible and visible irradiations within a constant irradiation time is introduced. The method uses a site-individual adaptation of the laser power by monitoring the retinal temperature rise during the treatment using optoacoustics. This provides feedback to adjust the therapy laser power during the irradiation. The technique was demonstrated on rabbits in vivo using a 532-nm continuous wave Nd:YAG laser. The temperature measurement was performed with 523-nm Q-switched Nd:YLF laser pulses with 75-ns pulse duration at 1-kHz repetition rate. The beam diameter on the fundus was 200 μm for both lasers, respectively. The aim temperatures ranged from 50°C to 75°C in 11 eyes of 7 rabbits. The results showed ophthalmoscopically invisible effects below 55°C with therapy laser powers over a wide range. The standard deviation for the measured temperatures ranged from 2.1°C for an aim temperature of 50°C to 4.7°C for 75°C. The ED50 temperature value for ophthalmoscopically visible lesions in rabbits was determined as 65.3°C. The introduced method can be used for retinal irradiations with adjustable temperature elevations.


  • Open Access

    Biomedical optics centers: forty years of multidisciplinary clinical translation for improving human health

    by Bruce J. Tromberg, R. Rox Anderson, Reginald Birngruber, Ralf Brinkmann, Michael W. Berns, John A. Parrish, Gabriela Apiou-Sbirlea

    The annual impact of photonics on the U.S. economy is estimated at $3 trillion, with biophotonics a fast-growing ∼$90  billion/year (worldwide) component.1,2 However, the present robust commercial activity in biophotonics was, by comparison, practically nonexistent in the late 1970s and early 1980s when the Wellman Center for Photomedicine (WCP, Mass General Hospital, USA), the Beckman Laser Institute and Medical Clinic (BLI, University of California Irvine, USA), and the Medical Laser Center Lübeck (MLL at the University of Lübeck, Germany) were in formative states. The emergence of these and other multidisciplinary centers for lasers and optics in biology and medicine over the past 30 to 40 years is a remarkable success story that parallels the growth of a variety of medical photonics technologies spanning from medical lasers to endoscopes, and optical coherence tomography (OCT) to near-infrared oximetry. This article is not intended to be a comprehensive review of all centers that have played a key role in this worldwide expansion. Rather we highlight three complementary programs with roots going back to the mid-late 1970s that emerged and grew under similar circumstances with colocated clinical and technology development activities.


  • Lesion strength control by automatic temperature guided retinal photocoagulation

    by Kerstin Schlott, Stefan Koinzer, Alexander Baade, Reginald Birngruber, Johann Roider, Ralf Brinkmann

    Laser photocoagulation is an established treatment for a variety of retinal diseases. However, when using the same irradiation parameter, the size and strength of the lesions are unpredictable due to unknown inter- and intraindividual optical properties of the fundus layers. The aim of this work is to investigate a feedback system to generate desired lesions of preselectable strengths by automatically controlling the irradiation time. Optoacoustics were used for retinal temperature monitoring. A 532-nm continuous wave Nd:YAG laser was used for photocoagulation. A 75-ns/523-nm Q-switched Nd:YLF laser simultaneously excited temperature-dependent pressure transients, which were detected at the cornea by an ultrasonic transducer embedded in a contact lens. The temperature data were analyzed during the irradiation by a LabVIEW routine. The treatment laser was switched off automatically when the required lesion strength was achieved. Five different feedback control algorithms for different lesion sizes were developed and tested on rabbits in vivo. With a laser spot diameter of 133  μm, five different lesion types with ophthalmoscopically visible diameters ranging mostly between 100 and 200  μm, and different appearances were achieved by automatic exposure time control. The automatically controlled lesions were widely independent of the treatment laser power and the retinal pigmentation.


  • Polyacrylamide gel substrates that simulate the mechanical stiffness of normal and malignant neuronal tissues increase protoporphyin IX synthesis in glioma cells

    by Carolyn J. Niu, Carl J. Fisher, Kira Scheffler, Rachel Wan, Hoda Maleki, Haijiao Liu, Yu Sun, Craig A. A. Simmons, Reginald Birngruber, Lothar Lilge

    Protoporphyrin IX (PPIX) produced following the administration of exogenous 5d-aminolevulinic acid is clinically approved for photodynamic therapy and fluorescence-guided resection in various jurisdictions around the world. For both applications, quantification of PPIX forms the basis for accurate therapeutic dose calculation and identification of malignant tissues for resection. While it is well established that the PPIX synthesis and accumulation rates are subject to the cell’s biochemical microenvironment, the effect of the physical microenvironment, such as matrix stiffness, has received little attention to date. Here we studied the proliferation rate and PPIX synthesis and accumulation in two glioma cell lines U373 and U118 cultured under five different substrate conditions, including the conventional tissue culture plastic and polyacrylamide gels that simulated tissue stiffness of normal brain (1 kPa) and glioblastoma tumors (12 kPa). We found that the proliferation rate increased with substrate stiffness for both cell lines, but not in a linear fashion. PPIX concentration was significantly higher in cells cultured on tissue-simulating gels than on the much stiffer tissue culture plastic for both cell lines. These findings, albeit preliminary, suggest that the physical microenvironment might be an important determinant of tumor aggressiveness and PPIX synthesis in glioma cells.


  • Open Access

    Validation of two-dimensional and three-dimensional measurements of subpleural alveolar size parameters by optical coherence tomography

    by Carolin I. Unglert, William C. Warger, Jeroen Hostens, Eman Namati, Reginald Birngruber, Brett E. Bouma, Guillermo J. Tearney

    Despite a good understanding of overall lung mechanics, the structure–function relationship at the alveolar level is still insufficiently understood. Quantitative measurements of alveolar sizes and size changes over the physiologic breathing cycle could significantly advance the development of analytical and computational fluid-dynamic models to investigate the mechanisms of gas exchange and aerosol deposition during various ventilation strategies.1 However, measuring 3- and 4-D alveolar sizes in vivo is challenging owing to their small scales and constant motion during respiratory cycles. In a human, for example, alveoli are estimated to be 100–300 μm in diameter with 10-μm walls, and undergo approximately 15 breaths per minute with an overlying cardiac motion of more than 60 beats per minute at rest.


  • Real-time temperature determination during retinal photocoagulation on patients

    by Ralf Brinkmann, Stefan Koinzer, Kerstin Schlott, Lars Ptaszynski, Marco Bever, Alexander Baade, Susanne Luft, Yoko Miura, Johann Roider, Reginald Birngruber

    The induced thermal damage in retinal photocoagulation depends on the temperature increase and the time of irradiation. The temperature rise is unknown due to intraocular variations in light transmission, scattering and grade of absorption in the retinal pigment epithelium (RPE) and the choroid. Thus, in clinical practice, often stronger and deeper coagulations are applied than therapeutically needed, which can lead to extended neuroretinal damage and strong pain perception. This work focuses on an optoacoustic (OA) method to determine the temperature rise in real-time during photocoagulation by repetitively exciting thermoelastic pressure transients with nanosecond probe laser pulses, which are simultaneously applied to the treatment radiation. The temperature-dependent pressure amplitudes are non-invasively detected at the cornea with an ultrasonic transducer embedded in the contact lens. During clinical treatment, temperature courses as predicted by heat diffusion theory are observed in most cases. For laser spot diameters of 100 and 300 μm, and irradiation times of 100 and 200 ms, respectively, peak temperatures range between 70°C and 85°C for mild coagulations. The obtained data look very promising for the realization of a feedback-controlled treatment, which automatically generates preselected and reproducible coagulation strengths, unburdens the ophthalmologist from manual laser dosage, and minimizes adverse effects and pain for the patient.