Cheng-Guo Tong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cheng-Guo Tong has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Ya-Xian Fan
Guilin University of Electronic Technology
2 shared publications - Zhi-Yong Tao
Guilin University of Electronic Technology
2 shared publications - Cheng Yuan
School of Electronic Information, Guilin University of Electronic Technology, Beihai 536000, China
1 shared publication - Hai-Ling He
Guangxi Key Laboratory of Wireless Wideband Communication and Signal Processing, Guilin University of Electronic Technology, Guilin 541004, China
1 shared publication - Haiqin Ma
School of Electronic Information, Guilin University of Electronic Technology, Beihai 536000, China
1 shared publication - Haoen Sun
Research Center for Advanced Rechnology of Marine Information, Guilin University of Electronic Technology, Beihai 536000, China
1 shared publication
Latest Publications
- Open Access
A Simultaneous Measurement Sensor for Temperature and Curvature Based on Congruent Quasi-Helical Long-Period Fiber Grating
This article presents a long-period fiber-grating sensor based on a congruent quasi-helical structure (CQH-LPFG) with the two-parameter measurement of both temperature and curvature. The CQH-LPFG sensor was manufactured using a high-frequency CO2 laser, and an innovative quasi-helical structure was introduced into the two-parameter measurement of the temperature and curvature of the optical fiber sensor with excellent results. The experiment and analysis demonstrate that the curvature sensitivities of the three resonance peaks in the 1440 nm to 1540 nm transmission spectrum were 11.88 nm/m−1, 8.05 nm/m−1, and 11.11 nm/m−1, and the curvature varied ranging from 0.156 m−1 to 0.494 m−1. The three resonance peaks showed temperature responsivities of 29.87 pm/°C, 24.65 pm/°C, and 36.85 pm/°C, respectively, and the linear fit was of excellent quality. In the case of measuring both curvature and temperature changes simultaneously, the resonant peak wavelength of the CQH-LPFG sensor was demodulated through matrix analysis, with dip A and dip C providing superior simultaneous measurements. These features make it a promising candidate for applications such as engineering machinery and the health inspection of buildings.
Open AccessA Simultaneous Measurement Sensor for Temperature and Curvature Based on Congruent Quasi-Helical Long-Period Fiber Grating
This article presents a long-period fiber-grating sensor based on a congruent quasi-helical structure (CQH-LPFG) with the two-parameter measurement of both temperature and curvature. The CQH-LPFG sensor was manufactured using a high-frequency CO2 laser, and an innovative quasi-helical structure was introduced into the two-parameter measurement of the temperature and curvature of the optical fiber sensor with excellent results. The experiment and analysis demonstrate that the curvature sensitivities of the three resonance peaks in the 1440 nm to 1540 nm transmission spectrum were 11.88 nm/m−1, 8.05 nm/m−1, and 11.11 nm/m−1, and the curvature varied ranging from 0.156 m−1 to 0.494 m−1. The three resonance peaks showed temperature responsivities of 29.87 pm/°C, 24.65 pm/°C, and 36.85 pm/°C, respectively, and the linear fit was of excellent quality. In the case of measuring both curvature and temperature changes simultaneously, the resonant peak wavelength of the CQH-LPFG sensor was demodulated through matrix analysis, with dip A and dip C providing superior simultaneous measurements. These features make it a promising candidate for applications such as engineering machinery and the health inspection of buildings.
- Open Access
An Electrically Tunable Terahertz Filter Based on Liquid-Crystal-Filled Slits with Wall Corrugations
We propose a type of hollow planar waveguide with corrugated walls, which can realize electrically tunable terahertz (THz) filtering by filling the slit with liquid crystals. When the THz signals propagate in a planar waveguide with periodic corrugations, the transmission spectrum always exhibits many pass and stop bands. Inserting a section of defects in the middle of the periodic corrugations can excite an extremely narrow transmission peak, which would be a very good THz filter for frequency division. To achieve tunability of this narrow linewidth THz filter, we also fill the slit between the two corrugated walls with a nematic liquid crystal. The effective refractive index of liquid crystals will change with the external electric field, thus tuning the frequency of the narrow peak. The simulated results show that the center frequency of the proposed filter can be tuned linearly in the frequency range of 0.984~1.023 THz by the external electric field. Moreover, the bandwidth of the filter can be adjusted from 3.2 GHz to 0.3 GHz by increasing the number of periods in the waveguide, and a maximum Q value of 2556 can be achieved when the number of periods at both sides of the defect is 12.
Open AccessAn Electrically Tunable Terahertz Filter Based on Liquid-Crystal-Filled Slits with Wall Corrugations
We propose a type of hollow planar waveguide with corrugated walls, which can realize electrically tunable terahertz (THz) filtering by filling the slit with liquid crystals. When the THz signals propagate in a planar waveguide with periodic corrugations, the transmission spectrum always exhibits many pass and stop bands. Inserting a section of defects in the middle of the periodic corrugations can excite an extremely narrow transmission peak, which would be a very good THz filter for frequency division. To achieve tunability of this narrow linewidth THz filter, we also fill the slit between the two corrugated walls with a nematic liquid crystal. The effective refractive index of liquid crystals will change with the external electric field, thus tuning the frequency of the narrow peak. The simulated results show that the center frequency of the proposed filter can be tuned linearly in the frequency range of 0.984~1.023 THz by the external electric field. Moreover, the bandwidth of the filter can be adjusted from 3.2 GHz to 0.3 GHz by increasing the number of periods in the waveguide, and a maximum Q value of 2556 can be achieved when the number of periods at both sides of the defect is 12.
- Open Access
Internal Cylinder Identification Based on Different Transmission of Longitudinal and Shear Ultrasonic Waves
We have built a Fizeau fiber interferometer to investigate the internal cylindrical defects in an aluminum plate based on laser ultrasonic techniques. The ultrasound is excited in the plate by a Q-switched Nd:YAG laser. When the ultrasonic waves interact with the internal defects, the transmitted amplitudes of longitudinal and shear waves are different. The experimental results show that the difference in transmission amplitudes can be attributed to the high frequency damping of internal cylinders. When the scanning point is close to the internal defect, the longitudinal waves attenuate significantly in the whole defect area, and their amplitude is always smaller than that of shear waves. By comparing the transmitted amplitudes of longitudinal and shear waves at different scanning points, we can achieve a C scan image of the sample to realize the visual inspection of internal defects. Our system exhibits outstanding performance in detecting internal cylinders, which could be used not only in evaluating structure cracks but also in exploring ultrasonic transmission characteristics.
Open AccessInternal Cylinder Identification Based on Different Transmission of Longitudinal and Shear Ultrasonic Waves
We have built a Fizeau fiber interferometer to investigate the internal cylindrical defects in an aluminum plate based on laser ultrasonic techniques. The ultrasound is excited in the plate by a Q-switched Nd:YAG laser. When the ultrasonic waves interact with the internal defects, the transmitted amplitudes of longitudinal and shear waves are different. The experimental results show that the difference in transmission amplitudes can be attributed to the high frequency damping of internal cylinders. When the scanning point is close to the internal defect, the longitudinal waves attenuate significantly in the whole defect area, and their amplitude is always smaller than that of shear waves. By comparing the transmitted amplitudes of longitudinal and shear waves at different scanning points, we can achieve a C scan image of the sample to realize the visual inspection of internal defects. Our system exhibits outstanding performance in detecting internal cylinders, which could be used not only in evaluating structure cracks but also in exploring ultrasonic transmission characteristics.