Massimo Antognozzi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Massimo Antognozzi has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
- Mervyn John Miles
Univ. of Bristol (United Kingdom)
7 shared publications - Thang Nguyen
Department of Engineering, Texas A&M University–Corpus Christi, Corpus Christi, TX 78412, USA
7 shared publications - Guido Herrmann
Control Systems and Robotics Group (CSR), Department of Electrical and Electronic Engineering, The University of Manchester, Manchester, U.K.
6 shared publications Christopher Edwards
5 shared publications- Kaiqiang Zhang
United Kingdom Atomic Energy Authority (UKAEA), Abingdon, U.K.
5 shared publications Mervyn Miles
5 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
Strained alkyne functionalization of carbon dots enables selective photodynamic killing of Gram-positive bacteria
Strained-alkyne functionalised CDs enable selective photodynamic antibacterial activity. Under low-energy LED light, they achieve >99.9% killing of Gram-positive bacteria and reduce biofilm biomass by 57% via ROS-mediated oxidative stress.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
Open AccessStrained alkyne functionalization of carbon dots enables selective photodynamic killing of Gram-positive bacteria
Strained-alkyne functionalised CDs enable selective photodynamic antibacterial activity. Under low-energy LED light, they achieve >99.9% killing of Gram-positive bacteria and reduce biofilm biomass by 57% via ROS-mediated oxidative stress.
- Open Access
- 6 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
A rapid method of evaluating cytotoxic drug efficacy using sub-cellular fluctuation imaging
Determining whether potential cancer therapies effectively kill cancer cells is important for informing effective therapeutic choice for patients. Here we describe a rapid label-free method for testing drug efficacy in vitro that evaluates cellular viability from sub-cellular fluctuation imaging (SCFI). We used staurosporine and paclitaxel as known cytotoxic drugs at different concentrations, and four different human cancer-derived cell lines: PC3 (prostate), Caco-2 (colorectal), Calu-3 (lung) and A549 (lung). Both drugs caused a rapid decrease in sub-cellular fluctuations within 1 to 3 h except when the specific cell line was known to be resistant to one of the drugs. We also demonstrated that the method is able to differentiate between treated and untreated PC3 cells within 3 to 4 h after cells have been plated, thus eliminating the need for overnight incubation, and further decreasing the total time needed to evaluate drug efficacy. SCFI is therefore able to identify reliably if drugs are cytotoxic within 3 h of addition, which is considerably faster than current commonly used techniques.
- 6 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessA rapid method of evaluating cytotoxic drug efficacy using sub-cellular fluctuation imaging
Determining whether potential cancer therapies effectively kill cancer cells is important for informing effective therapeutic choice for patients. Here we describe a rapid label-free method for testing drug efficacy in vitro that evaluates cellular viability from sub-cellular fluctuation imaging (SCFI). We used staurosporine and paclitaxel as known cytotoxic drugs at different concentrations, and four different human cancer-derived cell lines: PC3 (prostate), Caco-2 (colorectal), Calu-3 (lung) and A549 (lung). Both drugs caused a rapid decrease in sub-cellular fluctuations within 1 to 3 h except when the specific cell line was known to be resistant to one of the drugs. We also demonstrated that the method is able to differentiate between treated and untreated PC3 cells within 3 to 4 h after cells have been plated, thus eliminating the need for overnight incubation, and further decreasing the total time needed to evaluate drug efficacy. SCFI is therefore able to identify reliably if drugs are cytotoxic within 3 h of addition, which is considerably faster than current commonly used techniques.
- 11 February 2022
- Published by Elsevier in Biophysical Journal
- Vol. 121 (3) , 137a-138a
Investigating the use of sub-cellular fluctuation imaging with Neisseria gonorrhoeae
- 11 February 2022
- Published by Elsevier in Biophysical Journal
- Vol. 121 (3) , 137a-138a
Investigating the use of sub-cellular fluctuation imaging with Neisseria gonorrhoeae
- 11 February 2022
- Published by Elsevier in Biophysical Journal
- Vol. 121 (3) , 301a
Use of sub-cellular fluctuation imaging (SCFI) as a rapid antimicrobial susceptibility test
- 11 February 2022
- Published by Elsevier in Biophysical Journal
- Vol. 121 (3) , 301a
Use of sub-cellular fluctuation imaging (SCFI) as a rapid antimicrobial susceptibility test
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (11) , 11403-11413
Real-Time Force Reconstruction in a Transverse Dynamic Force Microscope
One major functionality of force microscopes is their ability to measure forces at a high sensitivity, thereby, allowing understanding of vital mechanisms: for instance, in bio-specimens. The investigation of a specimens viscoelasticity on nano-scale can have significant scientific impact, but has been inhibited by the lack of fast, comprehensive scanning instruments. In principle, transverse dynamic force microscopes (TDFMs) permit the measurement of interaction forces within delicate samples in a non-contact manner. The force measurements are reconstructed via complicated offline analysis in TDFMs, therefore, they can hardly be utilised as an online force measuring tool. This paper introduces a novel integrated robust design for practical scanning using the TDFM system. The digital design is implemented in fixed-point arithmetic using Field Programmable Gate Array (FPGA) devices, thereby, permitting measurement of the interaction force at a high sampling rate. The novel digital design tackles different implementation issues achieving fast and robust force measuring performance. This enables a new force-scan mode for the TDFM, realising for the first time, online force mapping of sample-surfaces in real-time.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (11) , 11403-11413
Real-Time Force Reconstruction in a Transverse Dynamic Force Microscope
One major functionality of force microscopes is their ability to measure forces at a high sensitivity, thereby, allowing understanding of vital mechanisms: for instance, in bio-specimens. The investigation of a specimens viscoelasticity on nano-scale can have significant scientific impact, but has been inhibited by the lack of fast, comprehensive scanning instruments. In principle, transverse dynamic force microscopes (TDFMs) permit the measurement of interaction forces within delicate samples in a non-contact manner. The force measurements are reconstructed via complicated offline analysis in TDFMs, therefore, they can hardly be utilised as an online force measuring tool. This paper introduces a novel integrated robust design for practical scanning using the TDFM system. The digital design is implemented in fixed-point arithmetic using Field Programmable Gate Array (FPGA) devices, thereby, permitting measurement of the interaction force at a high sampling rate. The novel digital design tackles different implementation issues achieving fast and robust force measuring performance. This enables a new force-scan mode for the TDFM, realising for the first time, online force mapping of sample-surfaces in real-time.
- Open Access
Towards a Fully Automated Scanning Probe Microscope for Biomedical Applications
The increase in capabilities of Scanning Probe Microscopy (SPM) has resulted in a parallel increase in complexity that limits the use of this technique outside of specialised research laboratories. SPM automation could substantially expand its application domain, improve reproducibility and increase throughput. Here, we present a bottom-up design in which the combination of positioning stages, orientation, and detection of the probe produces an SPM design compatible with full automation. The resulting probe microscope achieves sub-femtonewton force sensitivity whilst preserving low mechanical drift ( nm/min in-plane and nm/min vertically). The additional integration of total internal reflection microscopy, and the straightforward operations in liquid, make this instrument configuration particularly attractive to future biomedical applications.Open AccessTowards a Fully Automated Scanning Probe Microscope for Biomedical Applications
The increase in capabilities of Scanning Probe Microscopy (SPM) has resulted in a parallel increase in complexity that limits the use of this technique outside of specialised research laboratories. SPM automation could substantially expand its application domain, improve reproducibility and increase throughput. Here, we present a bottom-up design in which the combination of positioning stages, orientation, and detection of the probe produces an SPM design compatible with full automation. The resulting probe microscope achieves sub-femtonewton force sensitivity whilst preserving low mechanical drift ( nm/min in-plane and nm/min vertically). The additional integration of total internal reflection microscopy, and the straightforward operations in liquid, make this instrument configuration particularly attractive to future biomedical applications. - 1 January 2020
- Published by Elsevier in Control Engineering Practice
- Vol. 94
A super-twisting observer for atomic-force reconstruction in a probe microscope
- 1 January 2020
- Published by Elsevier in Control Engineering Practice
- Vol. 94
A super-twisting observer for atomic-force reconstruction in a probe microscope
- Open Access
- 2 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (6) , 4729-4740
A Multimode Transverse Dynamic Force Microscope—Design, Identification, and Control
The transverse dynamic force microscope (TDFM) and its shear force sensing principle permit true non-contact force detection in contrast to typical atomic force microscopes. The two TDFM measurement signals for the cantilever allow, in principle, two different scanning modes of which, in particular, the second presented here permits a full-scale non-contact scan. Previous research mainly focused on developing the sensing mechanism, whereas this work investigates the vertical axis dynamics for advanced robust closed-loop control. This paper presents a new TDFM digital control solution, built on field-programmable gate array (FPGA) equipment running at high implementation frequencies. The integrated control system allows the implementation of online customizable controllers, and raster-scans in two modes at very high detection bandwidth and nano-precision. Robust control algorithms are designed, implemented, and practically assessed. The two realized scanning modes are experimentally evaluated by imaging nano-spheres with known dimensions in wet conditions.
- 2 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (6) , 4729-4740
Open AccessA Multimode Transverse Dynamic Force Microscope—Design, Identification, and Control
The transverse dynamic force microscope (TDFM) and its shear force sensing principle permit true non-contact force detection in contrast to typical atomic force microscopes. The two TDFM measurement signals for the cantilever allow, in principle, two different scanning modes of which, in particular, the second presented here permits a full-scale non-contact scan. Previous research mainly focused on developing the sensing mechanism, whereas this work investigates the vertical axis dynamics for advanced robust closed-loop control. This paper presents a new TDFM digital control solution, built on field-programmable gate array (FPGA) equipment running at high implementation frequencies. The integrated control system allows the implementation of online customizable controllers, and raster-scans in two modes at very high detection bandwidth and nano-precision. Robust control algorithms are designed, implemented, and practically assessed. The two realized scanning modes are experimentally evaluated by imaging nano-spheres with known dimensions in wet conditions.
- Open Access
Imaging of sub-cellular fluctuations provides a rapid way to observe bacterial viability and response to antibiotics
Determining the viability of bacteria in a sample is an essential microbiological technique used in healthcare, industrial bioprocesses and research. Increasingly, attention has been focussing on antimicrobial susceptibility tests (AST), allowing rapid and appropriate prescribing of antibiotics. Current AST are limited in speed as they rely on detecting growth of microorganisms. Faster AST could be enabled by the recent discovery that living bacteria manifest nano-scale fluctuations, which reduce when the bacteria die. Here, we demonstrate a direct method of visualising fluctuations within bacterial cells using Sub-Cellular Fluctuation Imaging (SCFI), which is based on Total Internal Reflection Microscopy (TIRM). We show that SCFI can measure the viability of bacterial samples within minutes, distinguishing not only between live and dead bacteria but also live bacteria in different metabolic states. Importantly, we subsequently show that SCFI can rapidly distinguish antibiotic-treated resistant and susceptible bacteria, and therefore has particular application as a rapid AST.
Open AccessImaging of sub-cellular fluctuations provides a rapid way to observe bacterial viability and response to antibiotics
Determining the viability of bacteria in a sample is an essential microbiological technique used in healthcare, industrial bioprocesses and research. Increasingly, attention has been focussing on antimicrobial susceptibility tests (AST), allowing rapid and appropriate prescribing of antibiotics. Current AST are limited in speed as they rely on detecting growth of microorganisms. Faster AST could be enabled by the recent discovery that living bacteria manifest nano-scale fluctuations, which reduce when the bacteria die. Here, we demonstrate a direct method of visualising fluctuations within bacterial cells using Sub-Cellular Fluctuation Imaging (SCFI), which is based on Total Internal Reflection Microscopy (TIRM). We show that SCFI can measure the viability of bacterial samples within minutes, distinguishing not only between live and dead bacteria but also live bacteria in different metabolic states. Importantly, we subsequently show that SCFI can rapidly distinguish antibiotic-treated resistant and susceptible bacteria, and therefore has particular application as a rapid AST.
- Open Access
- 21 December 2016
- Published by Wiley in Asian Journal of Control
- Vol. 20 (4) , 1317-1328
Real‐Time Sliding Mode Observer Scheme for Shear Force Estimation in a Transverse Dynamic Force Microscope
This paper describes a sliding mode observer scheme for estimation of the shear force affecting the cantilever in a Transverse Dynamic Force Microscope (TDFM). The vertically oriented cantilever is oscillated in the proximity to the specimen under investigation. The amplitude of oscillation of the cantilever tip is affected by these shear forces. They are created by the ordered‐water layer above the specimen. The oscillation amplitude is therefore a measure of distance between the tip and the surface of the specimen. Consequently, the estimation of the shear forces provides useful information about the specimen characteristics. For estimating the shear forces, an approximate finite dimensional model of the cantilever is created using the method of lines. This model is subsequently reduced in terms of its order. An unknown input sliding mode observer has been used to reconstruct the unknown shear forces using only tip position measurements and the cantilever excitation. This paper describes the development of the sliding mode scheme and presents experimental results from the TDFM set up at the Centre for Nanoscience and Quantum Information (NSQI) at Bristol University.
- 21 December 2016
- Published by Wiley in Asian Journal of Control
- Vol. 20 (4) , 1317-1328
Open AccessReal‐Time Sliding Mode Observer Scheme for Shear Force Estimation in a Transverse Dynamic Force Microscope
This paper describes a sliding mode observer scheme for estimation of the shear force affecting the cantilever in a Transverse Dynamic Force Microscope (TDFM). The vertically oriented cantilever is oscillated in the proximity to the specimen under investigation. The amplitude of oscillation of the cantilever tip is affected by these shear forces. They are created by the ordered‐water layer above the specimen. The oscillation amplitude is therefore a measure of distance between the tip and the surface of the specimen. Consequently, the estimation of the shear forces provides useful information about the specimen characteristics. For estimating the shear forces, an approximate finite dimensional model of the cantilever is created using the method of lines. This model is subsequently reduced in terms of its order. An unknown input sliding mode observer has been used to reconstruct the unknown shear forces using only tip position measurements and the cantilever excitation. This paper describes the development of the sliding mode scheme and presents experimental results from the TDFM set up at the Centre for Nanoscience and Quantum Information (NSQI) at Bristol University.