YYYe Yang

Ye Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ye Yang has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Programmable ultrasound-mediated swarms manipulation of bacteria–red blood cell microrobots for tumor-specific thrombosis and robust photothermal therapy

    by Hui Ran, Ye Yang, Weijing Han, Ruijing Liang, Denghui Zhu, Bing Yuan, Cheng Xu, Dan Li, Jian Ren, Hong Pan, et al.


  • Top Cited Papers
    Open Access

    In-vivo programmable acoustic manipulation of genetically engineered bacteria

    by Ye Yang, Yaozhang Yang, Dingyuan Liu, Yuanyuan Wang, Minqiao Lu, Qi Zhang, Jiqing Huang, Yongchuan Li, Teng Ma, Fei Yan, et al.

    Acoustic tweezers can control target movement through the momentum interaction between an acoustic wave and an object. This technology has advantages over optical tweezers for in-vivo cell manipulation due to its high tissue penetrability and strong acoustic radiation force. However, normal cells are difficult to acoustically manipulate because of their small size and the similarity between their acoustic impedance and that of the medium. In this study, we use the heterologous expression of gene clusters to generate genetically engineered bacteria that can produce numerous sub-micron gas vesicles in the bacterial cytoplasm. We show that the presence of the gas vesicles significantly enhances the acoustic sensitivity of the engineering bacteria, which can be manipulated by ultrasound. We find that by employing phased-array-based acoustic tweezers, the engineering bacteria can be trapped into clusters and manipulated in vitro and in vivo via electronically steered acoustic beams, enabling the counter flow or on-demand flow of these bacteria in the vasculature of live mice. Furthermore, we demonstrate that the aggregation efficiency of engineering bacteria in a tumour is improved by utilizing this technology. This study provides a platform for the in-vivo manipulation of live cells, which will promote the progress of cell-based biomedical applications.


  • Sonodynamic Therapy With Concentric Ultrasound Imaging Array for Precision Theranostics for Atherosclerotic Plaque

    by Shuo Wang, Zeping Gao, Ye Yang, Qi Zhang, Jiqing Huang, Bing Wang, Shuang Lei, Qingyuan Tan, Dingyuan Liu, Lunhuang Guo, et al.

    Atherosclerotic cardiovascular disease is a major cause of human disability and mortality. Our previous study demonstrated the safety and efficacy of sonodynamic therapy (SDT) on atherosclerotic plaques. However, traditional single-element therapeutic transducer has single acoustic field, and positioning therapeutic and imaging transducers in the same position is difficult during ultrasound imaging-guided SDT. Continuously changing the position of transducers to intervene lesions in different positions is required, increasing the difficulty of treatment. Thus, SDT device with precise theranostics is required. Therefore, we designed and fabricated a ’concentric ultrasound transducer for theranostics’ (CUST-T), comprising a central 8 MHz linear array transducer for ultrasound imaging, and a peripheral 1 MHz hollow two-dimensional planar array transducer for generating phased-array focused ultrasound (PAFUS). The CUST-T exhibited high imaging resolution at a distance of up to 20 mm from the transducer and could generate personalized complex PAFUS acoustic field to match various lesions. In vitro biomedical results showed that, PAFUS-SDT induced RAW264.7-derived foam cell apoptosis leading to a targeting field apoptotic rate 4.36 to 6.24-times that of the non-targeting field and the significant apoptotic region was consistent with PAFUS acoustic field. In vivo , PAFUS-SDT guided by ultrasound imaging significantly increased the lumen area (P < 0.05) and collagen level (P < 0.01), whereas the wall thickness (P < 0.05) and lipid content (P < 0.01) of rabbit femoral artery were reduced. In conclusion, CUST-T provided image guidance sufficient for accurate SDT for atherosclerotic plaques in peripheral arteries and could be applied in clinical practice.


  • Research on objective evaluation model for fusion image of multi-source detector

    by Zhou Zheng, Ye Yang, Gangcheng Jiao, Pengbo Yang, Shiwei Lei, Lei Yan, Hongchang Cheng

    Aiming at the problem of the lack of comprehensive and objective evaluation methods for near-infrared and low-light-level multi-band fusion images, this paper proposes a multi-dimensional fusion image quality evaluation model that conforms to the interpretation habits of the human visual system. Firstly, the multi-source fusion image quality of low illumination CMOS, ICCD, EBAPS devices and near-infrared InGaAs detector is subjectively evaluated. Secondly, 14 classical evaluation indexes such as information entropy, mean gradient, mutual information and structure similarity are combined. The parameters of each index are dynamically adjusted, and finally an objective evaluation model is established based on the linear regression model. The SROCC, KROCC, PLCC and RMSE values of the optimized objective evaluation model and subjective evaluation score are 0.88, 0.72, 0.89 and 0.38, respectively, indicating that the accuracy and stability evaluation effect of the objective model is better. It solves the limitation of single factor evaluation index and realizes the comprehensive and objective quality evaluation of multi-source detector fusion image, which provides theoretical support and decision basis for the selection of night vision camera in complex illumination environment and the data fusion of multi-detector in low illumination condition. < <

  • 3D Acoustic Manipulation of Living Cells and Organisms Based On 2D Array

    by Ye Yang, Teng Ma, Qi Zhang, Jiqing Huang, Qi Hu, Yongchuan Li, Congzhi Wang, Hairong Zheng

    Flexible manipulation techniques for living cells and organisms are extremely useful tools for fundamental biomedical and life science research. Acoustic tweezers, which permit non-contact, label-free manipulation, are particularly suited to micromanipulation tasks as they provide a large acoustic radiation force and can be applied in various media. Here, we describe the design and fabrication of a 3 MHz, 64-element (8 × 8), 2D planar ultrasound array that realizes the multidimensional translation, rotation, orientation, and levitation of living cells and organisms. The focusing vortex and twin fields are generated using the holographic acoustic elements framework method. We demonstrate that the eggs and larvae of brine shrimp can be translated along a preset trajectory by controlling the central position of the vortex. By multiplexing counterclockwise vortices, clockwise vortices, and twin trap fields in a time sequence, the rotation direction of the shrimp eggs can be switched in real time, while non-spherical larvae can be reoriented. Moreover, the reflection of the acoustic beam can lift eggs and larvae from the bottom of the culture dish and further manipulate them in the vertical and horizontal directions. Additionally, we present quantitative analyses of the shrimp-egg rotation frequency with respect to the focal depths, topological charges of the vortex, and excitation voltages. These results indicate that acoustic tweezers based on 2D matrix arrays can realize complex and selective manipulation of living cells and organisms, thereby demonstrating their value for advancing research in the fields of cell assembly, tissue engineering, and micro-robot driving.


  • 3-D Acoustic Tweezers Using a 2-D Matrix Array With Time-Multiplexed Traps

    by Qi Hu, Teng Ma, Qi Zhang, Jimin Wang, Ye Yang, Feiyan Cai, Hairong Zheng

    The use of acoustic tweezers for precise manipulation of microparticles in the aqueous environment is essential and challenging for biomechanical applications in vivo . A 3-D acoustic tweezer is developed in this study for 3-D manipulation by using a two-dimensional (2-D) phased array consisting of 256 elements operating at 1.04 MHz. The emission phases of each element are iteratively determined by a backpropagation algorithm to generate multiple acoustic traps. Different traps are multiplexed in time, thus forming synthesized acoustic fields. We demonstrate the 3-D levitation and translation of positive acoustic contrast particles, a major class of bioparticles, in water by different acoustic traps, and compare the positional deviation along the intended path via experimentally measured trajectories. Improved manipulating stability was achieved by multiplexed acoustic traps. The 3-D acoustic tweezers proposed in this study provide a versatile approach of contactless bioparticle trapping and translation, paving the way toward future application of nanodroplet and microbubble manipulations.


  • Open Access

    Self-Navigated 3D Acoustic Tweezers in Complex Media Based on Time Reversal

    by Ye Yang, Teng Ma, Sinan Li, Qi Zhang, Jiqing Huang, Yifei Liu, Jianwei Zhuang, Yongchuan Li, Xuemin Du, Lili Niu, et al.

    Acoustic tweezers have great application prospects because they allow noncontact and noninvasive manipulation of microparticles in a wide range of media. However, the nontransparency and heterogeneity of media in practical applications complicate particle trapping and manipulation. In this study, we designed a 1.04 MHz 256-element 2D matrix array for 3D acoustic tweezers to guide and monitor the entire process using real-time 3D ultrasonic images, thereby enabling acoustic manipulation in nontransparent media. Furthermore, we successfully performed dynamic 3D manipulations on multiple microparticles using multifoci and vortex traps. We achieved 3D particle manipulation in heterogeneous media (through resin baffle and ex vivo macaque and human skulls) by introducing a method based on the time reversal principle to correct the phase and amplitude distortions of the acoustic waves. Our results suggest cutting-edge applications of acoustic tweezers such as acoustical drug delivery, controlled micromachine transfer, and precise treatment.