SFShangchun Fan

Shangchun Fan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shangchun Fan has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Hollow-core fiber photothermal methane sensor with temperature compensation

    by Pengcheng Zhao, Hoi Lut Ho, Wei Jin, Shangchun Fan, Shoufei Gao, Yingying Wang

    We demonstrate a high sensitivity all-fiber spectroscopic methane sensor based on photothermal interferometry. With a 2.4-m-long anti-resonant hollow-core fiber, a 1654 nm distributed feedback laser, and a Raman fiber amplifier, a noise-equivalent concentration of ∼ 4.3 p p b methane is achieved at the room temperature and pressure of ∼ 1 b a r . The effects of temperature on the photothermal phase modulation as well as the stability of the interferometer are studied. By introducing a temperature-dependent compensation factor and stabilizing the interferometer at quadrature, signal instability of ∼ 2.1 % is demonstrated for temperature variation from 296 to 373 K.


  • Gas sensing with mode-phase-difference photothermal spectroscopy assisted by a long period grating in a dual-mode negative-curvature hollow-core optical fiber

    by Pengcheng Zhao, Hoi Lut Ho, Wei Jin, Shangchun Fan, Shoufei Gao, Yingying Wang, Pu Wang

    We demonstrate sensitive gas detection with mode-phase-difference photothermal spectroscopy assisted by a long period grating (LPG) inscribed on a dual-mode negative-curvature hollow-core fiber (NC-HCF). The LPG is inscribed using a pulsed C O 2 laser, which enables pump propagation in the fundamental L P 01 mode to achieve maximum photothermal phase modulation while exciting both the L P 01 and L P 11 modes at the probe wavelength to form a dual-mode interferometer for detection of the phase difference. With a 1533 nm pump and a 1620 nm probe, a noise equivalent concentration of ∼ 2.2 ppb acetylene is achieved with an 85-cm-long NC-HCF gas cell and 1 s lock-in time constant.


  • Top Cited Papers
    Open Access

    Mode-phase-difference photothermal spectroscopy for gas detection with an anti-resonant hollow-core optical fiber

    by Pengcheng Zhao, Yan Zhao, Haihong Bao, Hoi Lut Ho, Wei Jin, Shangchun Fan, Shoufei Gao, Yingying Wang, Pu Wang

    Laser spectroscopy outperforms electrochemical and semiconductor gas sensors in selectivity and environmental survivability. However, the performance of the state-of-the-art laser sensors is still insufficient for many high precision applications. Here, we report mode-phase-difference photothermal spectroscopy with a dual-mode anti-resonant hollow-core optical fiber and demonstrate all-fiber gas (acetylene) detection down to ppt (parts-per-trillion) and <1% instability over a period of 3 hours. An anti-resonant hollow-core fiber could be designed to transmit light signals over a broad wavelength range from visible to infrared, covering molecular absorption lines of many important gases. This would enable multi-component gas detection with a single sensing element and pave the way for ultra-precision gas sensing for medical, environmental and industrial applications.


  • Open Access

    Room-Temperature Pressure-Induced Optically-Actuated Fabry-Perot Nanomechanical Resonator with Multilayer Graphene Diaphragm in Air

    by Cheng Li, Tian Lan, Xiyu Yu, Nan Bo, Jingyu Dong, Shangchun Fan

    We demonstrated a miniature and in situ ~13-layer graphene nanomechanical resonator by utilizing a simple optical fiber Fabry-Perot (F-P) interferometric excitation and detection scheme. The graphene film was transferred onto the endface of a ferrule with a 125-μm inner diameter. In contrast to the pre-tension induced in membrane that increased quality (Q) factor to ~18.5 from ~3.23 at room temperature and normal pressure, the limited effects of air damping on resonance behaviors at 10−2 and 105 Pa were demonstrated by characterizing graphene F-P resonators with open and micro-air-gap cavities. Then in terms of optomechanical behaviors of the resonator with an air micro-cavity configuration using a polished ferrule substrate, measured resonance frequencies were increased to the range of 509–542 kHz from several kHz with a maximum Q factor of 16.6 despite the lower Knudsen number ranging from 0.0002 to 0.0006 in damping air over a relative pressure range of 0–199 kPa. However, there was the little dependence of Q on resonance frequency. Note that compared with the inferior F-P cavity length response to applied pressures due to interfacial air leakage, the developed F-P resonator exhibited a consistent fitted pressure sensitivity of 1.18 × 105 kHz3/kPa with a good linearity error of 5.16% in the tested range. These measurements shed light on the pre-stress-dominated pressure-sensitive mechanisms behind air damping in in situ F-P resonant sensors using graphene or other 2D nanomaterials.


  • Open Access

    The Effect of Viscous Air Damping on an Optically Actuated Multilayer MoS2 Nanomechanical Resonator Using Fabry-Perot Interference

    by Yumei She, Cheng Li, Tian Lan, Xiaobin Peng, Qianwen Liu, Shangchun Fan

    We demonstrated a multilayer molybdenum disulfide (MoS2) nanomechanical resonator by using optical Fabry-Perot (F-P) interferometric excitation and detection. The thin circular MoS2 nanomembrane with an approximate 8-nm thickness was transferred onto the endface of a ferrule with an inner diameter of 125 μm, which created a low finesse F-P interferometer with a cavity length of 39.92 μm. The effects of temperature and viscous air damping on resonance behavior of the resonator were investigated in the range of −10–80 °C. Along with the optomechanical behavior of the resonator in air, the measured resonance frequencies ranged from 36 kHz to 73 kHz with an extremely low inflection point at 20 °C, which conformed reasonably to those solved by previously obtained thermal expansion coefficients of MoS2. Further, a maximum quality (Q) factor of 1.35 for the resonator was observed at 0 °C due to viscous dissipation, in relation to the lower Knudsen number of 0.0025~0.0034 in the tested temperature range. Moreover, measurements of Q factor revealed little dependence of Q on resonance frequency and temperature. These measurements shed light on the mechanisms behind viscous air damping in MoS2, graphene, and other 2D resonators.


  • Open Access

    Design and Theoretical Analysis of a Resonant Sensor for Liquid Density Measurement

    by Dezhi Zheng, Jiying Shi, Shangchun Fan

    In order to increase the accuracy of on-line liquid density measurements, a sensor equipped with a tuning fork as the resonant sensitive component is designed in this paper. It is a quasi-digital sensor with simple structure and high precision. The sensor is based on resonance theory and composed of a sensitive unit and a closed-loop control unit, where the sensitive unit consists of the actuator, the resonant tuning fork and the detector and the closed-loop control unit comprises precondition circuit, digital signal processing and control unit, analog-to-digital converter and digital-to-analog converter. An approximate parameters model of the tuning fork is established and the impact of liquid density, position of the tuning fork, temperature and structural parameters on the natural frequency of the tuning fork are also analyzed. On this basis, a tuning fork liquid density measurement sensor is developed. In addition, experimental testing on the sensor has been carried out on standard calibration facilities under constant 20 °C, and the sensor coefficients are calibrated. The experimental results show that the repeatability error is about 0.03% and the accuracy is about 0.4 kg/m3. The results also confirm that the method to increase the accuracy of liquid density measurement is feasible.