Veeresh Babu Vulligaddala
Veeresh Babu Vulligaddala has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
M. B. Srinivas
School of Engineering and Technology, BML Munjal University, Gurgaon, India
1 shared publication- Ravi Kumar Adusumalli
Ams semiconductors India Pvt. Ltd., Hyderabad, India
1 shared publication - Sudhakar Singamala
IOS, ams semiconductor India Pvt. Ltd., Hyderabad, Telangana India 500081
1 shared publication
Latest Publications
- 3 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 53 (10) , 2951-2957
A Digitally Calibrated Bandgap Reference With 0.06% Error for Low-Side Current Sensing Application
Accurate current and voltage measurements are essential for estimating the state of charge of an automotive battery. Typically, circuits are designed to measure low-side current of lead-acid battery. These circuits, however, require a precision reference voltage across a temperature range. In this paper, a design of an on-chip precision bandgap reference with a digitally calibrated technique is described. The bandgap is trimmed for temperature and magnitude and is calibrated digitally. Experimental results show that a maximum of 0.06% variation in the bandgap output for a temperature range of -40 °C-100 °C at a power supply voltage of 3.3 V is achieved. The integrated circuit is fabricated in 0.35-μm standard CMOS technology and occupies an area of 0.23 mm 2 .
- 3 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 53 (10) , 2951-2957
A Digitally Calibrated Bandgap Reference With 0.06% Error for Low-Side Current Sensing Application
Accurate current and voltage measurements are essential for estimating the state of charge of an automotive battery. Typically, circuits are designed to measure low-side current of lead-acid battery. These circuits, however, require a precision reference voltage across a temperature range. In this paper, a design of an on-chip precision bandgap reference with a digitally calibrated technique is described. The bandgap is trimmed for temperature and magnitude and is calibrated digitally. Experimental results show that a maximum of 0.06% variation in the bandgap output for a temperature range of -40 °C-100 °C at a power supply voltage of 3.3 V is achieved. The integrated circuit is fabricated in 0.35-μm standard CMOS technology and occupies an area of 0.23 mm 2 .