Nan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nan Li has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Bin Geng
State Grid Jilin Electric Power Co., Ltd. Changchun City, Jilin Province, 132021, China
2 shared publicationsLian Meng
Department of Electric Engineering, School of Northeast Electric Power University, Jilin City, Jilin Province, 132012, China
2 shared publicationsBaoluo Li
Key Laboratory of Modern Power System Simulation and Control and Renewable Energy Technology Ministry of Education Northeast Electric Power University Jilin People's Republic of China
1 shared publication- Baoluo Li
Department of Electrical Engineering, Northeast Electric Power University, Jilin 132012, China
1 shared publication - Jiafei Wu
Key Laboratory of Modern Power System Simulation and Control & Renewable Energy Technology, Ministry of Education, Northeast Electric Power University, Jilin 132012, China
1 shared publication Lei Gao
China Electric Power Research Institute Beijing 100192 People's Republic of China
1 shared publication
Latest Publications
- Open Access
Transient Stability Assessment of Power Systems Based on CLV-GAN and I-ECOC
In order to improve the multi-class assessment performance of transient stability in power systems, a multi-class assessment model that combines the CLV-GAN algorithm with an improved error-correcting output coding technique is proposed in the paper. To address the issue of the small number of unstable samples in power systems, a sample generation model is constructed by combining a dual-encoder VAE with a GAN network. The model generates effective artificial samples to balance the sample ratio between categories by learning the latent distribution of aperiodic and oscillatory unstable samples from the distribution. The decomposition method based on an improved error-correcting output coding algorithm is applied to convert the multi-class problem into a decision fusion issue for binary models. This method improves the overall performance of the multi-class model, particularly significantly increasing the recognition accuracy of discrimination against oscillatory unstable samples and reducing the safety hazards in the operation of power systems. The simulation validation was conducted on the IEEE 39-bus and IEEE 140-bus systems to confirm the effectiveness of the proposed model.
Open AccessTransient Stability Assessment of Power Systems Based on CLV-GAN and I-ECOC
In order to improve the multi-class assessment performance of transient stability in power systems, a multi-class assessment model that combines the CLV-GAN algorithm with an improved error-correcting output coding technique is proposed in the paper. To address the issue of the small number of unstable samples in power systems, a sample generation model is constructed by combining a dual-encoder VAE with a GAN network. The model generates effective artificial samples to balance the sample ratio between categories by learning the latent distribution of aperiodic and oscillatory unstable samples from the distribution. The decomposition method based on an improved error-correcting output coding algorithm is applied to convert the multi-class problem into a decision fusion issue for binary models. This method improves the overall performance of the multi-class model, particularly significantly increasing the recognition accuracy of discrimination against oscillatory unstable samples and reducing the safety hazards in the operation of power systems. The simulation validation was conducted on the IEEE 39-bus and IEEE 140-bus systems to confirm the effectiveness of the proposed model.
- Open Access
- 5 August 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (24) , 5858-5869
Dual cost‐sensitivity factors‐based power system transient stability assessment
In actual power system operation, there is a significant imbalance between the number of stable and unstable samples, and the misclassification costs of the two classes of samples are different. In addition to the class imbalance, there is another imbalance of regional samples in the feature space. In order to reduce the impact of class imbalance and regional imbalance on the performance of the model, a method of dual cost‐sensitivity factors for transient stability assessment is proposed. The method sets the balance factor and modulating factor in the loss function of light gradient boosting machine. The former corrects the classification bias caused by class imbalance, and the latter focuses on improving the classification accuracy of overlapping area samples. Combining the two factors, the model not only improves the accuracy of unstable samples, but also reduces the misjudgement of stable samples. In online application, a fast update scheme with memory function is proposed. In this scheme, incremental learning is used to update the model with fewer samples and less computational time, so as to achieve better evaluation performance. Case studies on three power systems demonstrate the generalisation performance of the proposed model and the effectiveness of the update scheme.
- 5 August 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (24) , 5858-5869
Open AccessDual cost‐sensitivity factors‐based power system transient stability assessment
In actual power system operation, there is a significant imbalance between the number of stable and unstable samples, and the misclassification costs of the two classes of samples are different. In addition to the class imbalance, there is another imbalance of regional samples in the feature space. In order to reduce the impact of class imbalance and regional imbalance on the performance of the model, a method of dual cost‐sensitivity factors for transient stability assessment is proposed. The method sets the balance factor and modulating factor in the loss function of light gradient boosting machine. The former corrects the classification bias caused by class imbalance, and the latter focuses on improving the classification accuracy of overlapping area samples. Combining the two factors, the model not only improves the accuracy of unstable samples, but also reduces the misjudgement of stable samples. In online application, a fast update scheme with memory function is proposed. In this scheme, incremental learning is used to update the model with fewer samples and less computational time, so as to achieve better evaluation performance. Case studies on three power systems demonstrate the generalisation performance of the proposed model and the effectiveness of the update scheme.
- Open Access
- 27 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 28403-28414
Transient Stability Assessment of Power System Based on XGBoost and Factorization Machine
As the deployment of wide-area measurement systems (WAMS) expands, data-driven methods are playing an increasingly important role in transient stability assessment (TSA). However, if the measured data is disturbed by noise or the topological structure of the power system changes, the performance of the model based on data-mining would decline so that it could not meet the needs of realworld scenarios. In this paper, we develop a TSA methodology based on extreme gradient boosting (XGBoost) and factorization machine (FM). Utilizing XGBoost to complete automatically the feature construction and transform the power flow into a sparse matrix. The influence of noise can be reduce due to the sparsity of the new feature set. On this basis, FM algorithm, which has advantage in processing the large sparse matrix, is introduced into the model to complete fault classification. Furthermore, the feature crossing function of FM further mines the interactive information of the spatio-temporal features. For changed topology scenarios, we propose a extended-training set scheme. Adding some pivotal data of topology changes to the training set improves the robustness of the model. Compared with existing studies, the proposed assessment model based on XGBoost-FM not only has the better generalization performance in the case of noise interference or changed topology, but also has the least time consumption and complexity.
- 27 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 28403-28414
Open AccessTransient Stability Assessment of Power System Based on XGBoost and Factorization Machine
As the deployment of wide-area measurement systems (WAMS) expands, data-driven methods are playing an increasingly important role in transient stability assessment (TSA). However, if the measured data is disturbed by noise or the topological structure of the power system changes, the performance of the model based on data-mining would decline so that it could not meet the needs of realworld scenarios. In this paper, we develop a TSA methodology based on extreme gradient boosting (XGBoost) and factorization machine (FM). Utilizing XGBoost to complete automatically the feature construction and transform the power flow into a sparse matrix. The influence of noise can be reduce due to the sparsity of the new feature set. On this basis, FM algorithm, which has advantage in processing the large sparse matrix, is introduced into the model to complete fault classification. Furthermore, the feature crossing function of FM further mines the interactive information of the spatio-temporal features. For changed topology scenarios, we propose a extended-training set scheme. Adding some pivotal data of topology changes to the training set improves the robustness of the model. Compared with existing studies, the proposed assessment model based on XGBoost-FM not only has the better generalization performance in the case of noise interference or changed topology, but also has the least time consumption and complexity.
- Open Access
- 1 August 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 600 (1) , 012026
Synchronous condenser excitation system parameter identification based on improved artificial bee colony algorithm
The quality of excitation control of the synchronous condenser directly determines the reactive power regulation ability and control support performance of the power grid.Aiming at parameter identification of non-linear links such as limit and saturation in the synchronous condenser excitation system, a parameter identification method of the synchronous condenser excitation system based on improved artificial bee colony algorithm is proposed.Firstly, the order of the phase modulation operation is deduced, and the mathematical model of the synchronous condenser excitation system is established based on it.Then the artificial bee colony algorithm is improved and applied to the parameter identification of the synchronous condenser excitation system. A parameter identification strategy based on sensitivity analysis is proposed for the unstable and multi-solution situation of multi-parameter identification results. Analysis of parameter sensitivity and identification based on parameter sensitivity. Finally, the identification parameters and the overall identification results obtained after sensitivity analysis are compared and analyzed. The results show that the proposed method can effectively identify the parameters of the non-linear link and has strong robustness. It can provide accurate models and parameters for power system stability analysis.
- 1 August 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 600 (1) , 012026
Open AccessSynchronous condenser excitation system parameter identification based on improved artificial bee colony algorithm
The quality of excitation control of the synchronous condenser directly determines the reactive power regulation ability and control support performance of the power grid.Aiming at parameter identification of non-linear links such as limit and saturation in the synchronous condenser excitation system, a parameter identification method of the synchronous condenser excitation system based on improved artificial bee colony algorithm is proposed.Firstly, the order of the phase modulation operation is deduced, and the mathematical model of the synchronous condenser excitation system is established based on it.Then the artificial bee colony algorithm is improved and applied to the parameter identification of the synchronous condenser excitation system. A parameter identification strategy based on sensitivity analysis is proposed for the unstable and multi-solution situation of multi-parameter identification results. Analysis of parameter sensitivity and identification based on parameter sensitivity. Finally, the identification parameters and the overall identification results obtained after sensitivity analysis are compared and analyzed. The results show that the proposed method can effectively identify the parameters of the non-linear link and has strong robustness. It can provide accurate models and parameters for power system stability analysis.
- 10 July 2019
- Published by Springer Nature
- p. 163-171
Power Plant Fan Fault Warning Based on Bidirectional Feature Compression and State Estimation
- 10 July 2019
- Published by Springer Nature
- p. 163-171
Power Plant Fan Fault Warning Based on Bidirectional Feature Compression and State Estimation
- Open Access
- 22 February 2017
- Published by MDPI AG in Preprints.org
Weak Signal Detection with Unknown Frequency Based on Characteristic Function of Poincaré Mapping
In engineering, when the Duffing oscillator is applied to weak periodic signal detection and frequency estimation, a vital issue that arises is the quantitative discrimination of the system phase state. In this paper, our study found that the distribution of the Duffing system solutions on the Poincaré section is different in the chaotic state, when compared with that in the periodic state. Moreover, the oscillation characteristic of the Poincaré mapping sequence is also different. On this basis, the characteristic function of the Poincaré mapping is defined as a quantitative parameter used to distinguish different states of the Duffing system. In order to estimate frequencies of the weak signal, the conventional Duffing oscillator detection model is improved. The measured signal is scanned by adjusting the frequency of the periodic driving force of the Duffing system. When the frequency of the periodic driving force is the same as the frequency of the measured signal, resonance occurs in the system. Combined with the discriminating criterion of the Poincare mapping characteristic function, we can estimate the frequency of the weak periodic signal. The numerical simulation and experimental results show that this method has a relatively high stability and reliability.
- 22 February 2017
- Published by MDPI AG in Preprints.org
Open AccessWeak Signal Detection with Unknown Frequency Based on Characteristic Function of Poincaré Mapping
In engineering, when the Duffing oscillator is applied to weak periodic signal detection and frequency estimation, a vital issue that arises is the quantitative discrimination of the system phase state. In this paper, our study found that the distribution of the Duffing system solutions on the Poincaré section is different in the chaotic state, when compared with that in the periodic state. Moreover, the oscillation characteristic of the Poincaré mapping sequence is also different. On this basis, the characteristic function of the Poincaré mapping is defined as a quantitative parameter used to distinguish different states of the Duffing system. In order to estimate frequencies of the weak signal, the conventional Duffing oscillator detection model is improved. The measured signal is scanned by adjusting the frequency of the periodic driving force of the Duffing system. When the frequency of the periodic driving force is the same as the frequency of the measured signal, resonance occurs in the system. Combined with the discriminating criterion of the Poincare mapping characteristic function, we can estimate the frequency of the weak periodic signal. The numerical simulation and experimental results show that this method has a relatively high stability and reliability.
- 1 January 2014
- Published by Springer Nature
- p. 943-949
Application Study of Spatiotemporal Chaotic Sequence in Code Division Multiple Access Communication System
- 1 January 2014
- Published by Springer Nature
- p. 943-949
Application Study of Spatiotemporal Chaotic Sequence in Code Division Multiple Access Communication System