XSXiaowei Song

Xiaowei Song

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiaowei Song has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Short-Circuit Characteristics of Superconducting Permanent Magnet Generators for 10 MW Wind Turbines

    by Dong Liu, Xiaowei Song, Xuezhou Wang, Mohamed Elhindi, Urfan Hasanov, Changqing Ye, Xiaofan Gou

    Superconducting permanent magnet generators (SCPMGs) are a potential candidate for 10 MW direct-drive wind turbine applications. This paper presents two 10 MW SCPMG designs using MgB2 cables for the armature winding and investigates the short-circuit characteristics of the designed SCPMGs. The first part of the results shows that the SCPMGs can double the shear stress of a conventional low-speed permanent magnet (PM) generator (from 65 kPa to 130 kPa) whilst avoiding demagnetization of the PMs in rated-load operation. However, the power factor has to drop to a range of 0.7-0.8. The second part of the results shows that during a sudden three-phase short circuit, the superconducting armature winding is prone to quench and the PMs are likely to be demagnetized in both proposed designs.


  • Commissioning of the World's First Full-Scale MW-Class Superconducting Generator on a Direct Drive Wind Turbine

    by Xiaowei Song, Carsten Buhrer, Anders Molgaard, Rasmus S. Andersen, Patrick Brutsaert, Markus Bauer, Jesper Hansen, Anders Varming Rebsdorf, Jurgen Kellers, Tiemo Winkler, et al.

    High temperature superconducting (HTS) generators could enable a lightweight and cost-effective direct drive (DD) wind turbines with large power ratings. The EU-funded EcoSwing project successfully demonstrated the world's first full-scale MW-class HTS generator on a commercial DD wind turbine. This paper focuses on the commissioning of the EcoSwing HTS generator on the wind turbine. The commissioning campaigns, including the rotor cool-down, excitation of the HTS field winding, and the power production of the generator, are presented in the paper. In the testing period, the generator was grid-connected for more than 650 hours and accumulatively produced more than 600 MWh to the grid. The target output power of the 3 MW class was reached. Throughout the rea-llife testing on the wind turbine, the generator performed well from the electromagnetic, thermal, and mechanical perspectives. Moreover, the generator even sustained three sudden short circuits in the converter system. The work reported has shown that HTS generators are technologically feasible for wind turbine applications, and the technology readiness level of HTS wind turbine generators has been improved to 6~7 for the first time.


  • Performance of Multi-Layer and Stator-Shifting Fractional-Slot Concentrated Windings for Superconducting Wind Turbine Generators Under Normal and Short-Circuit Operation Conditions

    by Dong Liu, Xiaowei Song, Jianning Dong

    High temperature superconducting (HTS) generators are being considered for large offshore direct-drive (DD) wind turbines as they are expected to be lightweight and compact. However, short circuit torques of an HTS generator with integral-slot distributed windings (ISDWs) is too high for wind turbine constructions, mainly due to the large magnetic air gap. Fractional-slot concentrated windings (FSCWs) can be considered to address this issue since their high leakage inductance can limit short circuit currents and torques. Unlike ISDWs, FSCWs produce great contents of space harmonics that can induce excessive losses in rotor components. Multi-layer and stator-shifting windings have been proposed to effectively reduce such losses. Based on a conventional 12-slot 10-pole configuration, this paper evaluates the effects of multi-layer and stator-shifting FSCWs on torque production and loss reduction in a 10 MW DD HTS generator. The examined losses include eddy current losses in the rotor shields and AC losses in the HTS field winding. This paper also checks if these FSCW schemes maintain the advantage of achieving a low short circuit torque. The results show that a 6-phase stator-shifting winding is the best choice for applying FSCWs to HTS generators.


  • Investigation Into Multi-Phase Armature Windings for High-Temperature Superconducting Wind Turbine Generators

    by Dong Liu, Xiaowei Song, Fujin Deng, Jianning Dong

    High-temperature superconducting (HTS) generators are being considered as a competitive candidate in large direct-drive (DD) wind turbines because of their features of being lightweight and compact. Normally a large air gap is inevitable in partially HTS generators, sacrificing the torque producing capability. In this paper, multi-phase armature windings for HTS generators are investigated to reduce the air gap length in HTS generators while not compromising generators' performance. Therefore, the torque density of HTS generators can be improved without any added costs. Five different multi-phase armature winding schemes are studied in the paper. Their performance regarding torque production and rotor losses in a 10 MW DD HTS generator are examined. The findings show that employing multi-phase armature windings can reduce the mechanical air gap without generating extra eddy current losses in the rotor, and the torque production can be improved by up to 9.1%. In addition, the alternating magnetic field reaching the HTS field winding are also reduced by using multi-phase armature windings, resulting in lower AC losses and cooling costs.


  • Ground Testing of the World's First MW-Class Direct-Drive Superconducting Wind Turbine Generator

    by Xiaowei Song, Carsten Buhrer, Patrick Brutsaert, Aymen Ammar, Jens Krause, Anne Bergen, Tiemo Winkler, Marc Dhalle, Jesper Hansen, Anders Varming Rebsdorf, et al.

    The EU-funded EcoSwing project addresses the world's first full-scale direct-drive (DD) high temperature superconducting (HTS) wind turbine generator. Before installing the generator on a commercial wind turbine, the generator was tested on the ground at the Dynamic Nacelle Testing Laboratory (DyNaLab) in Fraunhofer Institute for Wind Energy Systems (IWES), serving as an experimental validation of the generator design. This paper is centered on the ground testing of the EcoSwing HTS generator, which includes corresponding tests for validating the generator's cryogenic design and electromagnetic performance. Despite one HTS coil with a defect limiting the operating current significantly, partial power production up to 1 MW at 14.5 rpm was reached. The critical auxiliary systems, i.e., vacuum system and rotary helium coupling, behaved as expected or even better than anticipated. The work reported in the paper successfully validates the generator design, and also provides firsthand information prior to installing and testing the HTS generator on the wind turbine.


  • Experimental Validation of a Full-Size Pole Pair Set-Up of an MW-Class Direct Drive Superconducting Wind Turbine Generator

    by Xiaowei Song, Nenad Mijatovic, Carsten Buhrer, Jurgen Kellers, Jan Wiezoreck, Jens Krause, Hendrik Putz, Jesper Hansen, Anders Varming Rebsdorf

    The paper presents a full-size pole pair set-up of an MW-class direct-drive (DD) high temperature superconducting (HTS) wind turbine generator. The set-up serves as a precursor to the world's first full-scale DD HTS generator developed within the EU-funded EcoSwing project. The set-up built for de-risking employs an HTS field winding in the rotor and a conventional copper armature winding in the stator, representing a minimum independent unit of the corresponding full generator. Such a prototyping approach well reflects the performance of the full generator at a low cost. The paper first explains the main design considerations of the full generator, followed by designing and construction details of the set-up. Afterward, a number of tests for determining the key performance of the set-up are reported. The testing results showed that the HTS field winding ran stably at its rated current of 480 A and was well maintained below 30 K. Moreover, the tangential force in the set-up reached 29.8 kN, projecting the 2 MW target output power of the full generator. The set-up developed effectively validated the design ideas and engineering feasibilities of the full generator, leading to successful kick-off of the EcoSwing project.