Roger D. Soberanis-Mukul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Roger D. Soberanis-Mukul has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Mathias Unberath
Johns Hopkins University
13 shared publications Masaru Ishii
Johns Hopkins Medical Institutions, Baltimore, MD, 21287, USA
7 shared publications- Jan Emily Mangulabnan
Johns Hopkins University, Baltimore, MD, 21211, USA.
6 shared publications - Russell H. Taylor
Department of Computer Science, Johns Hopkins University
6 shared publications - Gregory D. Hager
Johns Hopkins University, Baltimore, MD, 21211, USA
5 shared publications - S. Swaroop Vedula
Johns Hopkins University, Baltimore, MD, 21211, USA
5 shared publications
Latest Publications
- 2 June 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (7) , 1495-1503
CT-override: endoscopic updates to preoperative anatomical models during ablative surgery
Preoperative CT provides a detailed anatomical basis for navigation in sinus surgery, guiding surgeons through intricate nasal structures while providing 3D awareness of critical anatomy. However, this static representation lacks the capacity to adapt to intraoperative tissue ablation. Efforts toward endoscope-based navigation reconstruct anatomy from visual cues alone, often without incorporating the CT prior that anchors surgical context. We propose a method to ground both CT and endoscope in a unified representation that bridges pre- and intraoperative domains, enabling dynamic updates of the surgical scene. We initialize the CT as a volumetric signed distance field (SDF), reformulating the update process with non-projective SDFs and accumulating camera-space observations with dense depth estimated from endoscopic video. These volumes are reconciled to produce intraoperative SDFs for updated surface mesh extraction. We validated our method on three multi-step cadaveric sinus datasets with paired preoperative CT and intraoperative endoscopic video of a simulated sinus surgery. We extract intraoperative meshes at each surgical step and compare to ground-truth intraoperative CT. Our vision-guided update method demonstrates improved surface alignment of the intraoperative representations throughout surgical progression, achieving submillimeter geometric accuracy. We show that integrating CT priors with intraoperative vision enables anatomically consistent updates to patient-specific models. This method provides a foundation for CT-consistent endoscopic reconstruction, and future work aimed at integrating camera localization toward a fully realized vision-guided surgical navigation system.
- 2 June 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (7) , 1495-1503
CT-override: endoscopic updates to preoperative anatomical models during ablative surgery
Preoperative CT provides a detailed anatomical basis for navigation in sinus surgery, guiding surgeons through intricate nasal structures while providing 3D awareness of critical anatomy. However, this static representation lacks the capacity to adapt to intraoperative tissue ablation. Efforts toward endoscope-based navigation reconstruct anatomy from visual cues alone, often without incorporating the CT prior that anchors surgical context. We propose a method to ground both CT and endoscope in a unified representation that bridges pre- and intraoperative domains, enabling dynamic updates of the surgical scene. We initialize the CT as a volumetric signed distance field (SDF), reformulating the update process with non-projective SDFs and accumulating camera-space observations with dense depth estimated from endoscopic video. These volumes are reconciled to produce intraoperative SDFs for updated surface mesh extraction. We validated our method on three multi-step cadaveric sinus datasets with paired preoperative CT and intraoperative endoscopic video of a simulated sinus surgery. We extract intraoperative meshes at each surgical step and compare to ground-truth intraoperative CT. Our vision-guided update method demonstrates improved surface alignment of the intraoperative representations throughout surgical progression, achieving submillimeter geometric accuracy. We show that integrating CT priors with intraoperative vision enables anatomically consistent updates to patient-specific models. This method provides a foundation for CT-consistent endoscopic reconstruction, and future work aimed at integrating camera localization toward a fully realized vision-guided surgical navigation system.
- 8 May 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (6) , 1197-1205
Global region reidentification for camera relocalization in video-based surgical navigation
Vision-based navigation systems rely on the registered camera poses in the CT space to guide surgeons. However, while it is possible to provide an approximate initialization, this registration becomes outdated as the endoscopic camera leaves and reenters the anatomy. Endoscopic camera relocalization is the process of determining the position of an endoscope relative to an anatomical reference after reinsertion. However, accurately reidentifying the global surgical scene and estimating camera pose have proven challenging due to the varying appearance of endoscopic sequences. We present a training-free approach to accurately reidentify the region of interest (ROI) and estimate the camera position of a query image after reinsertion. This method utilizes previously observed images with known poses and a CT scan. By combining advanced foundation models with classical techniques, we globally reidentify a prior image of the ROI, which is then used for image-based feature matching and pose recovery via the Perspective-n-Point algorithm. We conducted experiments on eight sequences from three cadaver studies. Our results show that our method accurately reidentifies when the endoscope reaches the ROI and identifies suitable image pairs for PnP-based pose estimation. It achieves an average translation error of 1.74 mm and a rotational error of 0.09 radians, making it suitable for reinitialization in image-based navigation without human intervention. Our work presents a training-free approach for detecting when the endoscope reenters the ROI and estimating the camera's pose after reinsertions. The approach demonstrates promising results contributing toward enabling pose reinitialization for vision-based surgical applications.
- 8 May 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (6) , 1197-1205
Global region reidentification for camera relocalization in video-based surgical navigation
Vision-based navigation systems rely on the registered camera poses in the CT space to guide surgeons. However, while it is possible to provide an approximate initialization, this registration becomes outdated as the endoscopic camera leaves and reenters the anatomy. Endoscopic camera relocalization is the process of determining the position of an endoscope relative to an anatomical reference after reinsertion. However, accurately reidentifying the global surgical scene and estimating camera pose have proven challenging due to the varying appearance of endoscopic sequences. We present a training-free approach to accurately reidentify the region of interest (ROI) and estimate the camera position of a query image after reinsertion. This method utilizes previously observed images with known poses and a CT scan. By combining advanced foundation models with classical techniques, we globally reidentify a prior image of the ROI, which is then used for image-based feature matching and pose recovery via the Perspective-n-Point algorithm. We conducted experiments on eight sequences from three cadaver studies. Our results show that our method accurately reidentifies when the endoscope reaches the ROI and identifies suitable image pairs for PnP-based pose estimation. It achieves an average translation error of 1.74 mm and a rotational error of 0.09 radians, making it suitable for reinitialization in image-based navigation without human intervention. Our work presents a training-free approach for detecting when the endoscope reenters the ROI and estimating the camera's pose after reinsertions. The approach demonstrates promising results contributing toward enabling pose reinitialization for vision-based surgical applications.
- 25 April 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (5) , 1033-1041
BronchOpt: vision-based pose optimization with fine-tuned foundation models for accurate bronchoscopy navigation
Accurate intra-operative localization of the endoscope tip relative to the anatomy remains a major challenge in bronchoscopy due to respiratory motion, anatomical variability, and CT-to-body divergence, which cause deformation and misalignment between intra-operative views and pre-operative CT. Existing vision-based methods often struggle to generalize across domains and patients, limiting robustness and leaving residual alignment errors. This work aims to establish a generalizable foundation for bronchoscopy navigation through a robust vision-based framework and a new synthetic benchmark dataset that enables standardized evaluation and reproducible development. We propose a vision-based pose optimization framework for frame-wise 2D-3D registration between intra-operative endoscopic views and pre-operative CT anatomy. A fine-tuned modality- and domain-invariant encoder enables direct similarity measurements between real endoscopic RGB images and CT-rendered depth maps, while differentiable rendering refines camera poses through depth consistency. To enhance reproducibility, we introduce the first public synthetic benchmark dataset for bronchoscopy navigation to address the lack of publicly available paired CT-endoscopy data. Trained solely on synthetic data distinct from the benchmark, our model attains an average translational error of 2.65 mm and a rotational error of 0.19 rad, demonstrating high localization accuracy and stability. Qualitative results on real patient data further confirm strong cross-domain generalization, achieving consistent frame-wise 2D-3D alignment without domain-specific adaptation. The proposed framework achieves robust, domain-invariant bronchoscopy localization through iterative vision-based optimization, offering a scalable solution toward reliable vision-based bronchoscopy localization. The introduced synthetic benchmark dataset provides a valuable resource for standardized evaluation on bronchoscopy navigation.
- 25 April 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (5) , 1033-1041
BronchOpt: vision-based pose optimization with fine-tuned foundation models for accurate bronchoscopy navigation
Accurate intra-operative localization of the endoscope tip relative to the anatomy remains a major challenge in bronchoscopy due to respiratory motion, anatomical variability, and CT-to-body divergence, which cause deformation and misalignment between intra-operative views and pre-operative CT. Existing vision-based methods often struggle to generalize across domains and patients, limiting robustness and leaving residual alignment errors. This work aims to establish a generalizable foundation for bronchoscopy navigation through a robust vision-based framework and a new synthetic benchmark dataset that enables standardized evaluation and reproducible development. We propose a vision-based pose optimization framework for frame-wise 2D-3D registration between intra-operative endoscopic views and pre-operative CT anatomy. A fine-tuned modality- and domain-invariant encoder enables direct similarity measurements between real endoscopic RGB images and CT-rendered depth maps, while differentiable rendering refines camera poses through depth consistency. To enhance reproducibility, we introduce the first public synthetic benchmark dataset for bronchoscopy navigation to address the lack of publicly available paired CT-endoscopy data. Trained solely on synthetic data distinct from the benchmark, our model attains an average translational error of 2.65 mm and a rotational error of 0.19 rad, demonstrating high localization accuracy and stability. Qualitative results on real patient data further confirm strong cross-domain generalization, achieving consistent frame-wise 2D-3D alignment without domain-specific adaptation. The proposed framework achieves robust, domain-invariant bronchoscopy localization through iterative vision-based optimization, offering a scalable solution toward reliable vision-based bronchoscopy localization. The introduced synthetic benchmark dataset provides a valuable resource for standardized evaluation on bronchoscopy navigation.
- Open Access
Did you just see that? Arbitrary view synthesis for egocentric replay of operating room workflows from ambient sensors
Observing surgical practice has historically relied on fixed vantage points or recollections, leaving the egocentric visual perspectives that guide clinical decisions undocumented. Fixed-camera video can capture surgical workflows at the room-scale, but cannot reconstruct what each team member actually saw. Thus, these videos only provide limited insights into how decisions that affect surgical safety, training, and workflow optimization are made. Here we introduce EgoSurg, the first framework to reconstruct the dynamic, egocentric replays for any operating room (OR) staff directly from wall-mounted fixed-camera video, and thus, without intervention to clinical workflow. EgoSurg couples geometry-driven neural rendering with diffusion-based view enhancement, enabling high-visual fidelity synthesis of arbitrary and egocentric viewpoints at any moment. In evaluation across multi-site surgical cases and controlled studies, EgoSurg reconstructs person-specific visual fields and arbitrary viewpoints with high visual quality and fidelity. By transforming existing OR camera infrastructure into a navigable dynamic 3D record, EgoSurg establishes a new foundation for immersive surgical data science, enabling surgical practice to be visualized, experienced, and analyzed from every angle.
Open AccessDid you just see that? Arbitrary view synthesis for egocentric replay of operating room workflows from ambient sensors
Observing surgical practice has historically relied on fixed vantage points or recollections, leaving the egocentric visual perspectives that guide clinical decisions undocumented. Fixed-camera video can capture surgical workflows at the room-scale, but cannot reconstruct what each team member actually saw. Thus, these videos only provide limited insights into how decisions that affect surgical safety, training, and workflow optimization are made. Here we introduce EgoSurg, the first framework to reconstruct the dynamic, egocentric replays for any operating room (OR) staff directly from wall-mounted fixed-camera video, and thus, without intervention to clinical workflow. EgoSurg couples geometry-driven neural rendering with diffusion-based view enhancement, enabling high-visual fidelity synthesis of arbitrary and egocentric viewpoints at any moment. In evaluation across multi-site surgical cases and controlled studies, EgoSurg reconstructs person-specific visual fields and arbitrary viewpoints with high visual quality and fidelity. By transforming existing OR camera infrastructure into a navigable dynamic 3D record, EgoSurg establishes a new foundation for immersive surgical data science, enabling surgical practice to be visualized, experienced, and analyzed from every angle.
- 23 August 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (1) , 11-19
The interpretable surgical temporal informer: explainable surgical time completion prediction
Purpose Predicting surgical time completion helps streamline surgical workflow and OR utilization, enhancing hospital efficacy. When time prediction is based on interventional video of the surgical site, time predictions may correlate with technical proficiency of the surgeon because skill is a useful proxy of completion time. To understand features that are predictive of surgical time in surgical site video, we develop prototype-like visual explanations, making them applicable to video sequences. Methods We introduce an interpretable method for predicting surgical duration by identifying prototype-like patterns within egocentric video of the surgical site. Unlike conventional image-based prototype models that generate patch-based prototypes, our method extracts video-based explanations tied to segments of surgical videos with similar time deviation patterns. We achieve this by comparing the principal components of feature representation differences at various time points in the predictions. To effectively capture long-range dependencies in the prediction task, we employ an informer as the primary predictive model. Results This model is applied to a dataset of 42 point-of-view craniotomy videos, collected under an approved IRB protocol. On average, our interpretable model performs better than the baseline models in surgical time completion. Conclusion Our approach not only contributes to the interpretability of surgical time predictions but also takes full advantage of the detailed information provided by surgical video data.
- 23 August 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (1) , 11-19
The interpretable surgical temporal informer: explainable surgical time completion prediction
Purpose Predicting surgical time completion helps streamline surgical workflow and OR utilization, enhancing hospital efficacy. When time prediction is based on interventional video of the surgical site, time predictions may correlate with technical proficiency of the surgeon because skill is a useful proxy of completion time. To understand features that are predictive of surgical time in surgical site video, we develop prototype-like visual explanations, making them applicable to video sequences. Methods We introduce an interpretable method for predicting surgical duration by identifying prototype-like patterns within egocentric video of the surgical site. Unlike conventional image-based prototype models that generate patch-based prototypes, our method extracts video-based explanations tied to segments of surgical videos with similar time deviation patterns. We achieve this by comparing the principal components of feature representation differences at various time points in the predictions. To effectively capture long-range dependencies in the prediction task, we employ an informer as the primary predictive model. Results This model is applied to a dataset of 42 point-of-view craniotomy videos, collected under an approved IRB protocol. On average, our interpretable model performs better than the baseline models in surgical time completion. Conclusion Our approach not only contributes to the interpretability of surgical time predictions but also takes full advantage of the detailed information provided by surgical video data.
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in Healthcare Technology Letters
- Vol. 12 (1)
Monocular Vision‐Based Endoscopic Sinus Navigation: A SLAM Driven Approach With CT Integration
Surgical navigation is critical in sinus surgery to enhance the surgeon's spatial awareness and improve precision, particularly around occluded critical structures. While external tracker‐based navigation systems exist, vision‐based solutions are preferred for being less intrusive and for enabling endoscopic image analysis to assist surgeons. However, monocular endoscopy navigation faces challenges associated with monocular reconstruction and camera pose estimation. This paper presents a proof of concept for monocular vision‐based sinus navigation that utilizes only preoperative CT data and the endoscope video stream to navigate the sinus anatomy. We developed a vision‐based navigation system that incorporates a SLAM algorithm to estimate the camera pose and reconstruct the 3D surface of the anatomy. Given an initial semi‐automated registration, the algorithm maps the SLAM‐based trajectories to the CT space while employing the reconstructed point cloud to solve for the scale interactively. The system displays the updates in the CT triplane visualization as SLAM reconstructs the scene and recovers pose information. We tested our system by performing an off‐site navigation in ten recorded endoscopic video streaming generated from sequences obtained from eight cadaveric subjects, comparing the vision‐based navigation to reference optical tracker pose data and obtaining translation and rotation errors of 3.2 mm and 4.9 degrees, respectively. Additionally, we performed three on‐site tests of our system on two different cadaver experiments. Our work evaluates a fully integrated system that closes the loop between image‐based reconstruction and CT visualization, and discusses the challenges to address to achieve clinical level surgical navigation.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in Healthcare Technology Letters
- Vol. 12 (1)
Open AccessMonocular Vision‐Based Endoscopic Sinus Navigation: A SLAM Driven Approach With CT Integration
Surgical navigation is critical in sinus surgery to enhance the surgeon's spatial awareness and improve precision, particularly around occluded critical structures. While external tracker‐based navigation systems exist, vision‐based solutions are preferred for being less intrusive and for enabling endoscopic image analysis to assist surgeons. However, monocular endoscopy navigation faces challenges associated with monocular reconstruction and camera pose estimation. This paper presents a proof of concept for monocular vision‐based sinus navigation that utilizes only preoperative CT data and the endoscope video stream to navigate the sinus anatomy. We developed a vision‐based navigation system that incorporates a SLAM algorithm to estimate the camera pose and reconstruct the 3D surface of the anatomy. Given an initial semi‐automated registration, the algorithm maps the SLAM‐based trajectories to the CT space while employing the reconstructed point cloud to solve for the scale interactively. The system displays the updates in the CT triplane visualization as SLAM reconstructs the scene and recovers pose information. We tested our system by performing an off‐site navigation in ten recorded endoscopic video streaming generated from sequences obtained from eight cadaveric subjects, comparing the vision‐based navigation to reference optical tracker pose data and obtaining translation and rotation errors of 3.2 mm and 4.9 degrees, respectively. Additionally, we performed three on‐site tests of our system on two different cadaver experiments. Our work evaluates a fully integrated system that closes the loop between image‐based reconstruction and CT visualization, and discusses the challenges to address to achieve clinical level surgical navigation.
- 22 May 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (7) , 1259-1266
OneSLAM to map them all: a generalized approach to SLAM for monocular endoscopic imaging based on tracking any point
Purpose Monocular SLAM algorithms are the key enabling technology for image-based surgical navigation systems for endoscopic procedures. Due to the visual feature scarcity and unique lighting conditions encountered in endoscopy, classical SLAM approaches perform inconsistently. Many of the recent approaches to endoscopic SLAM rely on deep learning models. They show promising results when optimized on singular domains such as arthroscopy, sinus endoscopy, colonoscopy or laparoscopy, but are limited by an inability to generalize to different domains without retraining. Methods To address this generality issue, we propose OneSLAM a monocular SLAM algorithm for surgical endoscopy that works out of the box for several endoscopic domains, including sinus endoscopy, colonoscopy, arthroscopy and laparoscopy. Our pipeline builds upon robust tracking any point (TAP) foundation models to reliably track sparse correspondences across multiple frames and runs local bundle adjustment to jointly optimize camera poses and a sparse 3D reconstruction of the anatomy. Results We compare the performance of our method against three strong baselines previously proposed for monocular SLAM in endoscopy and general scenes. OneSLAM presents better or comparable performance over existing approaches targeted to that specific data in all four tested domains, generalizing across domains without the need for retraining. Conclusion OneSLAM benefits from the convincing performance of TAP foundation models but generalizes to endoscopic sequences of different anatomies all while demonstrating better or comparable performance over domain-specific SLAM approaches. Future research on global loop closure will investigate how to reliably detect loops in endoscopic scenes to reduce accumulated drift and enhance long-term navigation capabilities.
- 22 May 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (7) , 1259-1266
OneSLAM to map them all: a generalized approach to SLAM for monocular endoscopic imaging based on tracking any point
Purpose Monocular SLAM algorithms are the key enabling technology for image-based surgical navigation systems for endoscopic procedures. Due to the visual feature scarcity and unique lighting conditions encountered in endoscopy, classical SLAM approaches perform inconsistently. Many of the recent approaches to endoscopic SLAM rely on deep learning models. They show promising results when optimized on singular domains such as arthroscopy, sinus endoscopy, colonoscopy or laparoscopy, but are limited by an inability to generalize to different domains without retraining. Methods To address this generality issue, we propose OneSLAM a monocular SLAM algorithm for surgical endoscopy that works out of the box for several endoscopic domains, including sinus endoscopy, colonoscopy, arthroscopy and laparoscopy. Our pipeline builds upon robust tracking any point (TAP) foundation models to reliably track sparse correspondences across multiple frames and runs local bundle adjustment to jointly optimize camera poses and a sparse 3D reconstruction of the anatomy. Results We compare the performance of our method against three strong baselines previously proposed for monocular SLAM in endoscopy and general scenes. OneSLAM presents better or comparable performance over existing approaches targeted to that specific data in all four tested domains, generalizing across domains without the need for retraining. Conclusion OneSLAM benefits from the convincing performance of TAP foundation models but generalizes to endoscopic sequences of different anatomies all while demonstrating better or comparable performance over domain-specific SLAM approaches. Future research on global loop closure will investigate how to reliably detect loops in endoscopic scenes to reduce accumulated drift and enhance long-term navigation capabilities.
- 16 May 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (7) , 1359-1366
An endoscopic chisel: intraoperative imaging carves 3D anatomical models
Purpose Preoperative imaging plays a pivotal role in sinus surgery where CTs offer patient-specific insights of complex anatomy, enabling real-time intraoperative navigation to complement endoscopy imaging. However, surgery elicits anatomical changes not represented in the preoperative model, generating an inaccurate basis for navigation during surgery progression. Methods: We propose a first vision-based approach to update the preoperative 3D anatomical model leveraging intraoperative endoscopic video for navigated sinus surgery where relative camera poses are known. We rely on comparisons of intraoperative monocular depth estimates and preoperative depth renders to identify modified regions. The new depths are integrated in these regions through volumetric fusion in a truncated signed distance function representation to generate an intraoperative 3D model that reflects tissue manipulation Results: We quantitatively evaluate our approach by sequentially updating models for a five-step surgical progression in an ex vivo specimen. We compute the error between correspondences from the updated model and ground-truth intraoperative CT in the region of anatomical modification. The resulting models show a decrease in error during surgical progression as opposed to increasing when no update is employed. Conclusion: Our findings suggest that preoperative 3D anatomical models can be updated using intraoperative endoscopy video in navigated sinus surgery. Future work will investigate improvements to monocular depth estimation as well as removing the need for external navigation systems. The resulting ability to continuously update the patient model may provide surgeons with a more precise understanding of the current anatomical state and paves the way toward a digital twin paradigm for sinus surgery
- 16 May 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (7) , 1359-1366
An endoscopic chisel: intraoperative imaging carves 3D anatomical models
Purpose Preoperative imaging plays a pivotal role in sinus surgery where CTs offer patient-specific insights of complex anatomy, enabling real-time intraoperative navigation to complement endoscopy imaging. However, surgery elicits anatomical changes not represented in the preoperative model, generating an inaccurate basis for navigation during surgery progression. Methods: We propose a first vision-based approach to update the preoperative 3D anatomical model leveraging intraoperative endoscopic video for navigated sinus surgery where relative camera poses are known. We rely on comparisons of intraoperative monocular depth estimates and preoperative depth renders to identify modified regions. The new depths are integrated in these regions through volumetric fusion in a truncated signed distance function representation to generate an intraoperative 3D model that reflects tissue manipulation Results: We quantitatively evaluate our approach by sequentially updating models for a five-step surgical progression in an ex vivo specimen. We compute the error between correspondences from the updated model and ground-truth intraoperative CT in the region of anatomical modification. The resulting models show a decrease in error during surgical progression as opposed to increasing when no update is employed. Conclusion: Our findings suggest that preoperative 3D anatomical models can be updated using intraoperative endoscopy video in navigated sinus surgery. Future work will investigate improvements to monocular depth estimation as well as removing the need for external navigation systems. The resulting ability to continuously update the patient model may provide surgeons with a more precise understanding of the current anatomical state and paves the way toward a digital twin paradigm for sinus surgery
- 5 May 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (7) , 1281-1284
Cognitive load in tele-robotic surgery: a comparison of eye tracker designs
Purpose Eye gaze tracking and pupillometry are evolving areas within the field of tele-robotic surgery, particularly in the context of estimating cognitive load (CL). However, this is a recent field, and current solutions for gaze and pupil tracking in robotic surgery require assessment. Considering the necessity of stable pupillometry signals for reliable cognitive load estimation, we compare the accuracy of three eye trackers, including head and console-mounted designs. Methods We conducted a user study with the da Vinci Research Kit (dVRK), to compare the three designs. We collected eye tracking and dVRK video data while participants observed nine markers distributed over the dVRK screen. We compute and analyze pupil detection stability and gaze prediction accuracy for the three designs. Results Head-worn devices present better stability and accuracy of gaze prediction and pupil detection compared to console-mounted systems. Tracking stability along the field of view varies between trackers, with gaze predictions detected at invalid zones of the image with high confidence. Conclusion While head-worn solutions show benefits in confidence and stability, our results demonstrate the need to improve eye tacker performance regarding pupil detection, stability, and gaze accuracy in tele-robotic scenarios.
- 5 May 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (7) , 1281-1284
Cognitive load in tele-robotic surgery: a comparison of eye tracker designs
Purpose Eye gaze tracking and pupillometry are evolving areas within the field of tele-robotic surgery, particularly in the context of estimating cognitive load (CL). However, this is a recent field, and current solutions for gaze and pupil tracking in robotic surgery require assessment. Considering the necessity of stable pupillometry signals for reliable cognitive load estimation, we compare the accuracy of three eye trackers, including head and console-mounted designs. Methods We conducted a user study with the da Vinci Research Kit (dVRK), to compare the three designs. We collected eye tracking and dVRK video data while participants observed nine markers distributed over the dVRK screen. We compute and analyze pupil detection stability and gaze prediction accuracy for the three designs. Results Head-worn devices present better stability and accuracy of gaze prediction and pupil detection compared to console-mounted systems. Tracking stability along the field of view varies between trackers, with gaze predictions detected at invalid zones of the image with high confidence. Conclusion While head-worn solutions show benefits in confidence and stability, our results demonstrate the need to improve eye tacker performance regarding pupil detection, stability, and gaze accuracy in tele-robotic scenarios.
- 8 April 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (6) , 1113-1120
Cognitive effort detection for tele-robotic surgery via personalized pupil response modeling
Purpose Gaze tracking and pupillometry are established proxies for cognitive load, giving insights into a user’s mental effort. In tele-robotic surgery, knowing a user’s cognitive load can inspire novel human–machine interaction designs, fostering contextual surgical assistance systems and personalized training programs. While pupillometry-based methods for estimating cognitive effort have been proposed, their application in surgery is limited by the pupil’s sensitivity to brightness changes, which can mask pupil’s response to cognitive load. Thus, methods considering pupil and brightness conditions are essential for detecting cognitive effort in unconstrained scenarios. Methods To contend with this challenge, we introduce a personalized pupil response model integrating pupil and brightness-based features. Discrepancies between predicted and measured pupil diameter indicate dilations due to non-brightness-related sources, i.e., cognitive effort. Combined with gaze entropy, it can detect cognitive load using a random forest classifier. To test our model, we perform a user study with the da Vinci Research Kit, where 17 users perform pick-and-place tasks in addition to auditory tasks known to generate cognitive effort responses. Results We compare our method to two baselines (BCPD and CPD), demonstrating favorable performance in varying brightness conditions. Our method achieves an average true positive rate of 0.78, outperforming the baselines (0.57 and 0.64). Conclusion We present a personalized brightness-aware model for cognitive effort detection able to operate under unconstrained brightness conditions, comparing favorably to competing approaches, contributing to the advancement of cognitive effort detection in tele-robotic surgery. Future work will consider alternative learning strategies, handling the difficult positive-unlabeled scenario in user studies, where only some positive and no negative events are reliably known.
- 8 April 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (6) , 1113-1120
Cognitive effort detection for tele-robotic surgery via personalized pupil response modeling
Purpose Gaze tracking and pupillometry are established proxies for cognitive load, giving insights into a user’s mental effort. In tele-robotic surgery, knowing a user’s cognitive load can inspire novel human–machine interaction designs, fostering contextual surgical assistance systems and personalized training programs. While pupillometry-based methods for estimating cognitive effort have been proposed, their application in surgery is limited by the pupil’s sensitivity to brightness changes, which can mask pupil’s response to cognitive load. Thus, methods considering pupil and brightness conditions are essential for detecting cognitive effort in unconstrained scenarios. Methods To contend with this challenge, we introduce a personalized pupil response model integrating pupil and brightness-based features. Discrepancies between predicted and measured pupil diameter indicate dilations due to non-brightness-related sources, i.e., cognitive effort. Combined with gaze entropy, it can detect cognitive load using a random forest classifier. To test our model, we perform a user study with the da Vinci Research Kit, where 17 users perform pick-and-place tasks in addition to auditory tasks known to generate cognitive effort responses. Results We compare our method to two baselines (BCPD and CPD), demonstrating favorable performance in varying brightness conditions. Our method achieves an average true positive rate of 0.78, outperforming the baselines (0.57 and 0.64). Conclusion We present a personalized brightness-aware model for cognitive effort detection able to operate under unconstrained brightness conditions, comparing favorably to competing approaches, contributing to the advancement of cognitive effort detection in tele-robotic surgery. Future work will consider alternative learning strategies, handling the difficult positive-unlabeled scenario in user studies, where only some positive and no negative events are reliably known.