Jiaolai Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiaolai Jiang has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Bingjie Zhu
Wenzhou Medical University
2 shared publications- Haoxi Wu
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, Jilin, China
2 shared publications Lizhu Yang
Wenzhou Medical University
2 shared publicationsShanli Yang
Institute of Materials, China Academy of Engineering Physics, Mianyang, 621900, China
2 shared publicationsShaofei Wang
2 shared publicationsSiwei Shi
Institute of Materials, China Academy of Engineering Physics, Mianyang, 621900, China
2 shared publications
Latest Publications
- 8 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (44) , 31654-31666
Fluorescence Lifetime Decoupling Enables Absolute Quantification of MicroRNA at Dense DNA-Gold Interfaces
Accurate quantification of microRNAs in complex biological fluids remains a challenge due to two intertwined analytical artifacts: false-positive signals from sterically bulky interferents and systematic signal underestimation from nanometal surface energy transfer (NSET) quenching. Here, we report a fluorescence lifetime (FL)-based decoupling strategy that mathematically isolates the NSET quenching bias and retrieves the true catalytic turnover number (TON ≈42.2) from conventionally quenched plasmonic readouts. Integrated with a dense DNA polymer brush that enforces strict size-exclusion selectivity (σ ≈ 0.22 chains/nm2), this approach enables absolute, calibration-free quantification of microRNA-21 directly in untreated human serum. The method achieves a limit of detection of 0.4 pM, excellent correlation with RT-qPCR (R2 = 0.978), and high diagnostic accuracy for colorectal cancer (AUC = 0.945 and threshold 1.55 pM). This FL decoupling protocol provides a standardized calibration method for eliminating optical artifacts in surface-tethered biosensing across different nanoprobe batches.
- 8 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (44) , 31654-31666
Fluorescence Lifetime Decoupling Enables Absolute Quantification of MicroRNA at Dense DNA-Gold Interfaces
Accurate quantification of microRNAs in complex biological fluids remains a challenge due to two intertwined analytical artifacts: false-positive signals from sterically bulky interferents and systematic signal underestimation from nanometal surface energy transfer (NSET) quenching. Here, we report a fluorescence lifetime (FL)-based decoupling strategy that mathematically isolates the NSET quenching bias and retrieves the true catalytic turnover number (TON ≈42.2) from conventionally quenched plasmonic readouts. Integrated with a dense DNA polymer brush that enforces strict size-exclusion selectivity (σ ≈ 0.22 chains/nm2), this approach enables absolute, calibration-free quantification of microRNA-21 directly in untreated human serum. The method achieves a limit of detection of 0.4 pM, excellent correlation with RT-qPCR (R2 = 0.978), and high diagnostic accuracy for colorectal cancer (AUC = 0.945 and threshold 1.55 pM). This FL decoupling protocol provides a standardized calibration method for eliminating optical artifacts in surface-tethered biosensing across different nanoprobe batches.
- 9 September 2026
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 633
The in situ study of reactive kinetics of uranium in dry and humid atmospheres by thermogravimetric technique
- 9 September 2026
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 633
The in situ study of reactive kinetics of uranium in dry and humid atmospheres by thermogravimetric technique
- 20 April 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (17) , 13069-13079
Overcoming the Thermodynamic Diffusion Barrier in DNA Cascade Amplifiers via Spatially Confined Entropy Reduction: A Versatile Kinetic Engineering Framework
The reaction efficiency of solution-phase DNA cascade amplifiers is fundamentally constrained by stochastic Brownian motion, creating a thermodynamic diffusion bottleneck that limits sensitivity and speed. To overcome this, we present a general kinetic engineering framework based on spatially confined entropy reduction. By integrating a DNA tetrahedron scaffold with a cascade amplification circuit, we successfully transition the reaction from a stochastic dilute-phase regime to a deterministic pseudosolid-phase regime. For the first time, we employ phase-space kinetic mapping to visualize the entropy-driven acceleration in DNA nanomachines. This comprehensive analysis reveals that this architecture increases the effective local concentration by 4 orders of magnitude by prepaying the entropic cost of molecular collision. Using targets spanning small molecules (BPA), macromolecules (Thrombin), and nucleic acids (miRNA), the system achieved a detection limit of 0.1 pM with rapid kinetics. This work establishes a theoretical blueprint. Crucially, the phase-space kinetic mapping framework proposed here serves as a universal toolkit for the community, offering a new dimension to evaluate and optimize next-generation DNA cascade amplifiers.
- 20 April 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (17) , 13069-13079
Overcoming the Thermodynamic Diffusion Barrier in DNA Cascade Amplifiers via Spatially Confined Entropy Reduction: A Versatile Kinetic Engineering Framework
The reaction efficiency of solution-phase DNA cascade amplifiers is fundamentally constrained by stochastic Brownian motion, creating a thermodynamic diffusion bottleneck that limits sensitivity and speed. To overcome this, we present a general kinetic engineering framework based on spatially confined entropy reduction. By integrating a DNA tetrahedron scaffold with a cascade amplification circuit, we successfully transition the reaction from a stochastic dilute-phase regime to a deterministic pseudosolid-phase regime. For the first time, we employ phase-space kinetic mapping to visualize the entropy-driven acceleration in DNA nanomachines. This comprehensive analysis reveals that this architecture increases the effective local concentration by 4 orders of magnitude by prepaying the entropic cost of molecular collision. Using targets spanning small molecules (BPA), macromolecules (Thrombin), and nucleic acids (miRNA), the system achieved a detection limit of 0.1 pM with rapid kinetics. This work establishes a theoretical blueprint. Crucially, the phase-space kinetic mapping framework proposed here serves as a universal toolkit for the community, offering a new dimension to evaluate and optimize next-generation DNA cascade amplifiers.
- Open Access
Highly Sensitive Adsorption and Detection of Iodide in Aqueous Solution by a Post-Synthesized Zirconium-Organic Framework
Effective methods of detection and removal of iodide ions (I−) from radioactive wastewater are urgently needed and developing them remains a great challenge. In this work, an Ag+ decorated stable nano-MOF UiO-66-(COOH)2 was developed for the I− to simultaneously capture and sense in aqueous solution. Due to the uncoordinated carboxylate groups on the UiO-66-(COOH)2 framework, Ag+ was successfully incorporated into the MOF and enhanced the intrinsic fluorescence of MOF. After adding iodide ions, Ag+ would be produced, following the formation of AgI. As a result, Ag+@UiO-66-(COOH)2 can be utilized for the removal of I− in aqueous solution, even in the presence of other common ionic ions (NO2−, NO3−, F−, SO42−). The removal capacity as high as 235.5 mg/g was calculated by Langmuir model; moreover, the fluorescence of Ag+@UiO-66-(COOH)2 gradually decreases with the deposition of AgI, which can be quantitatively depicted by a linear equation. The limit of detection toward I− is calculated to be 0.58 ppm.
Open AccessHighly Sensitive Adsorption and Detection of Iodide in Aqueous Solution by a Post-Synthesized Zirconium-Organic Framework
Effective methods of detection and removal of iodide ions (I−) from radioactive wastewater are urgently needed and developing them remains a great challenge. In this work, an Ag+ decorated stable nano-MOF UiO-66-(COOH)2 was developed for the I− to simultaneously capture and sense in aqueous solution. Due to the uncoordinated carboxylate groups on the UiO-66-(COOH)2 framework, Ag+ was successfully incorporated into the MOF and enhanced the intrinsic fluorescence of MOF. After adding iodide ions, Ag+ would be produced, following the formation of AgI. As a result, Ag+@UiO-66-(COOH)2 can be utilized for the removal of I− in aqueous solution, even in the presence of other common ionic ions (NO2−, NO3−, F−, SO42−). The removal capacity as high as 235.5 mg/g was calculated by Langmuir model; moreover, the fluorescence of Ag+@UiO-66-(COOH)2 gradually decreases with the deposition of AgI, which can be quantitatively depicted by a linear equation. The limit of detection toward I− is calculated to be 0.58 ppm.
- 3 August 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (18) , 4158-4166
DNAzyme recognition triggered cascade signal amplification for rapid and highly sensitive visual detection of uranyl ions
A 40 min rapid and highly sensitive assay for visualized detection of UO22+ in water samples is reported. A dynamic range 1~50 nM and a LOD of 0.48 nM were obtained. Concentrations as low as 5 nM UO22+ could be distinguished by the naked eye.
- 3 August 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (18) , 4158-4166
DNAzyme recognition triggered cascade signal amplification for rapid and highly sensitive visual detection of uranyl ions
A 40 min rapid and highly sensitive assay for visualized detection of UO22+ in water samples is reported. A dynamic range 1~50 nM and a LOD of 0.48 nM were obtained. Concentrations as low as 5 nM UO22+ could be distinguished by the naked eye.
- 4 December 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 10 (11) , 4006-4018
Research progress of SERS on uranyl ions and uranyl compounds: a review
There is an urgent demand for the rapid and sensitive analysis of uranyl ions and uranyl compounds in environmental monitoring and nuclear emergency fields. However, most of the current analytical techniques do not provide both the content of uranyl ions and the structural information of uranyl compounds in trace level. Comparatively, surface-enhanced Raman scattering (SERS) can achieve the single molecule detection and provide the structural information of molecules as well. Hence, SERS has become a suitable solution for the in situ analysis of trace uranyl species, especially when coupled with a portable Raman spectrometer. This review systematically introduces the SERS studies of uranyl ions and uranyl compounds in recent years, including the fabrication of silver and gold substrates with a high density of “hotspots” and excellent stability, the performances of different substrates in the quantitative detection of uranyl ions and structural analysis of uranyl compounds, and the explanations for the Raman enhancement mechanisms of uranyl ions. Additionally, the developments about the field assay of uranyl ions are also elaborated to further evaluate the practical application prospect of the SERS technique. Finally, we dissect the current problems existing in this field and thus provide a valuable reference for the trend and future direction.
- 4 December 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 10 (11) , 4006-4018
Research progress of SERS on uranyl ions and uranyl compounds: a review
There is an urgent demand for the rapid and sensitive analysis of uranyl ions and uranyl compounds in environmental monitoring and nuclear emergency fields. However, most of the current analytical techniques do not provide both the content of uranyl ions and the structural information of uranyl compounds in trace level. Comparatively, surface-enhanced Raman scattering (SERS) can achieve the single molecule detection and provide the structural information of molecules as well. Hence, SERS has become a suitable solution for the in situ analysis of trace uranyl species, especially when coupled with a portable Raman spectrometer. This review systematically introduces the SERS studies of uranyl ions and uranyl compounds in recent years, including the fabrication of silver and gold substrates with a high density of “hotspots” and excellent stability, the performances of different substrates in the quantitative detection of uranyl ions and structural analysis of uranyl compounds, and the explanations for the Raman enhancement mechanisms of uranyl ions. Additionally, the developments about the field assay of uranyl ions are also elaborated to further evaluate the practical application prospect of the SERS technique. Finally, we dissect the current problems existing in this field and thus provide a valuable reference for the trend and future direction.
- Open Access
- 18 July 2019
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 4 (7) , 12319-12324
In Situ Surface-Enhanced Raman Spectroscopy Detection of Uranyl Ions with Silver Nanorod-Decorated Tape
Surface-enhanced Raman spectroscopy (SERS) has been utilized for rapid analysis of uranyl ions (UO22+) on account of its fast response and high sensitivity. However, the difficulty of fabricating a suitable SERS substrate for in situ analysis of uranyl ions severely restricts its practical application. Hence, we proposed flexible and adhesive SERS tape decorated with silver nanorod (AgNR) arrays for in situ detection of UO22+. The SERS tape was fabricated through a simple “paste & peel off” procedure by transferring the slanted AgNR arrays from silicon to the transparent tape surface. UO22+ can be easily in situ detected by placing the AgNR SERS tape into an aqueous solution or pasting it onto the solid matrix surface due to the excellent transparent feature of the tape. The proposed SERS tape with well-distributed AgNRs effectively improved the reproducibility and sensitivity for UO22+ analysis. UO22+ with concentration as low as 100 nM was easily detected. Besides, UO22+ adsorbed on an iron disc and rock surface also can be rapidly in situ detected. With its simplicity and convenience, the AgNR SERS tape-based SERS technique offers a promising approach for environmental monitoring and nuclear accident emergency detection.
- 18 July 2019
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 4 (7) , 12319-12324
Open AccessIn Situ Surface-Enhanced Raman Spectroscopy Detection of Uranyl Ions with Silver Nanorod-Decorated Tape
Surface-enhanced Raman spectroscopy (SERS) has been utilized for rapid analysis of uranyl ions (UO22+) on account of its fast response and high sensitivity. However, the difficulty of fabricating a suitable SERS substrate for in situ analysis of uranyl ions severely restricts its practical application. Hence, we proposed flexible and adhesive SERS tape decorated with silver nanorod (AgNR) arrays for in situ detection of UO22+. The SERS tape was fabricated through a simple “paste & peel off” procedure by transferring the slanted AgNR arrays from silicon to the transparent tape surface. UO22+ can be easily in situ detected by placing the AgNR SERS tape into an aqueous solution or pasting it onto the solid matrix surface due to the excellent transparent feature of the tape. The proposed SERS tape with well-distributed AgNRs effectively improved the reproducibility and sensitivity for UO22+ analysis. UO22+ with concentration as low as 100 nM was easily detected. Besides, UO22+ adsorbed on an iron disc and rock surface also can be rapidly in situ detected. With its simplicity and convenience, the AgNR SERS tape-based SERS technique offers a promising approach for environmental monitoring and nuclear accident emergency detection.