Jonas Andersson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonas Andersson has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
A Liander
RaySearch Laboratories AB, Stockholm, Sweden
1 shared publicationA Lundin
RaySearch Laboratories AB, Stockholm, Sweden
1 shared publication- Alberto Torresin
Asst Ospedale Niguarda, Struttura Complessa DI Fisica Sanitaria, Milan, Italy
1 shared publication Amber J. Gislason‐Lee
University of Leeds Worsley Building, Clarendon Way Leeds LS2 9JT UK
1 shared publication- Ana Geao
Nuclear Medicine Department, Hospital CUF Descobertas, UK
1 shared publication - Andrea Scotti
KTH Royal Institute of Technology, Department of Physics, Stockholm, Sweden
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 59, 101201
Strengthening incident learning in radiotherapy practice: insights from the MARLIN study
- 1 June 2026
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 59, 101201
Open AccessStrengthening incident learning in radiotherapy practice: insights from the MARLIN study
- Open Access
- 20 November 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (S1) , S12809
Deep learning estimation of proton stopping power with photon-counting computed tomography: a virtual study
It is estimated that around half of cancer patients receive radiation therapy as part of their treatment plan, making it one of our most indispensable cancer treatment modalities.1 Conventional radiotherapy employs high-energy photons for administration of radiation dose and accounts for around 99% of all radiation treatments.2 Although photon radiotherapy has seen great progress in tumor control and sparing of normal tissue, an impediment to the latter objective is the continuous deposition of dose along the beam trajectory through the patient.2 This may pose a clinical challenge when considering organs at risk and selecting optimal beam angles.
- 20 November 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (S1) , S12809
Open AccessDeep learning estimation of proton stopping power with photon-counting computed tomography: a virtual study
It is estimated that around half of cancer patients receive radiation therapy as part of their treatment plan, making it one of our most indispensable cancer treatment modalities.1 Conventional radiotherapy employs high-energy photons for administration of radiation dose and accounts for around 99% of all radiation treatments.2 Although photon radiotherapy has seen great progress in tumor control and sparing of normal tissue, an impediment to the latter objective is the continuous deposition of dose along the beam trajectory through the patient.2 This may pose a clinical challenge when considering organs at risk and selecting optimal beam angles.
- Open Access
- 1 August 2021
- Published by Elsevier in Physica Medica
- Vol. 88, 218-225
Artificial intelligence and the medical physics profession - A Swedish perspective
- 1 August 2021
- Published by Elsevier in Physica Medica
- Vol. 88, 218-225
Open AccessArtificial intelligence and the medical physics profession - A Swedish perspective
- Open Access
- 30 April 2021
- Published by Wiley in Medical Physics
- Vol. 48 (7) , E671-E696
Estimation of patient skin dose in fluoroscopy: summary of a joint report by AAPM TG357 and EFOMP
Background: Physicians use fixed C‐arm fluoroscopy equipment with many interventional radiological and cardiological procedures. The associated effective dose to a patient is generally considered low risk, as the benefit‐risk ratio is almost certainly highly favorable. However, X‐ray‐induced skin injuries may occur due to high absorbed patient skin doses from complex fluoroscopically guided interventions (FGI). Suitable action levels for patient‐specific follow‐up could improve the clinical practice.There is a need for a refined metric regarding follow‐up of X‐ray‐induced patient injuries and the knowledge gap regarding skin dose‐related patient information from fluoroscopy devices must be filled. The most useful metric to indicate a risk of erythema, epilation or greater skin injury that also includes actionable information is the peak skin dose, that is, the largest dose to a region of skin.Materials and Methods: The report is based on a comprehensive review of best practices and methods to estimate peak skin dose found in the scientific literature and situates the importance of the Digital Imaging and Communication in Medicine (DICOM) standard detailing pertinent information contained in the Radiation Dose Structured Report (RDSR) and DICOM image headers for FGI devices. Furthermore, the expertise of the task group members and consultants have been used to bridge and discuss different methods and associated available DICOM information for peak skin dose estimation.Results: The report contributes an extensive summary and discussion of the current state of the art in estimating peak skin dose with FGI procedures with regard to methodology and DICOM information. Improvements in skin dose estimation efforts with more refined DICOM information are suggested and discussed.Conclusions: The endeavor of skin dose estimation is greatly aided by the continuing efforts of the scientific medical physics community, the numerous technology enhancements, the dose‐controlling features provided by the FGI device manufacturers, and the emergence and greater availability of the DICOM RDSR. Refined and new dosimetry systems continue to evolve and form the infrastructure for further improvements in accuracy. Dose‐related content and information systems capable of handling big data are emerging for patient dose monitoring and quality assurance tools for large‐scale multihospital enterprises.
- 30 April 2021
- Published by Wiley in Medical Physics
- Vol. 48 (7) , E671-E696
Open AccessEstimation of patient skin dose in fluoroscopy: summary of a joint report by AAPM TG357 and EFOMP
Background: Physicians use fixed C‐arm fluoroscopy equipment with many interventional radiological and cardiological procedures. The associated effective dose to a patient is generally considered low risk, as the benefit‐risk ratio is almost certainly highly favorable. However, X‐ray‐induced skin injuries may occur due to high absorbed patient skin doses from complex fluoroscopically guided interventions (FGI). Suitable action levels for patient‐specific follow‐up could improve the clinical practice.There is a need for a refined metric regarding follow‐up of X‐ray‐induced patient injuries and the knowledge gap regarding skin dose‐related patient information from fluoroscopy devices must be filled. The most useful metric to indicate a risk of erythema, epilation or greater skin injury that also includes actionable information is the peak skin dose, that is, the largest dose to a region of skin.Materials and Methods: The report is based on a comprehensive review of best practices and methods to estimate peak skin dose found in the scientific literature and situates the importance of the Digital Imaging and Communication in Medicine (DICOM) standard detailing pertinent information contained in the Radiation Dose Structured Report (RDSR) and DICOM image headers for FGI devices. Furthermore, the expertise of the task group members and consultants have been used to bridge and discuss different methods and associated available DICOM information for peak skin dose estimation.Results: The report contributes an extensive summary and discussion of the current state of the art in estimating peak skin dose with FGI procedures with regard to methodology and DICOM information. Improvements in skin dose estimation efforts with more refined DICOM information are suggested and discussed.Conclusions: The endeavor of skin dose estimation is greatly aided by the continuing efforts of the scientific medical physics community, the numerous technology enhancements, the dose‐controlling features provided by the FGI device manufacturers, and the emergence and greater availability of the DICOM RDSR. Refined and new dosimetry systems continue to evolve and form the infrastructure for further improvements in accuracy. Dose‐related content and information systems capable of handling big data are emerging for patient dose monitoring and quality assurance tools for large‐scale multihospital enterprises.
- 1 June 2006
- Published by Wiley in Medical Physics
- Vol. 33 (6Part22) , 2273
TH-C-230A-10: A General Software Framework for Investigations in Radiation Therapy Planning
- 1 June 2006
- Published by Wiley in Medical Physics
- Vol. 33 (6Part22) , 2273
TH-C-230A-10: A General Software Framework for Investigations in Radiation Therapy Planning