Wolfgang Fenz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wolfgang Fenz has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Stefan Thumfart
Research Unit Medical Informatics, RISC Software GmbH, 4232 Hagenberg, Austria
6 shared publications - Matthias Gmeiner
Department of Neurosurgery, Kepler University Hospital, Johannes Kepler University Linz, Linz, Austria; Clinical Research Institute for Neuroscience, Johannes Kepler University Linz, Linz, Austria
4 shared publications - Jozsef Nagy
Affiliation eulerian-solutions e.U. Leonfeldnerstraße 245, Linz, Austria
3 shared publications - Zoltan Major
Johannes Kepler University Linz
3 shared publications Andreas Gruber
Affiliations Department of Neurosurgery, Kepler University Hospital, Johannes Kepler University Linz, Linz, Austria, Clinical Research Institute for Neuroscience, Johannes Kepler University Linz, Linz, Austria
2 shared publications- Andreas J. Gruber
University of Konstanz, Konstanz, Germany
2 shared publications
Latest Publications
- Open Access
- 2 September 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (9) , e0331297
Rupture risk assessment for AComA aneurysms with morphological, hemodynamic and structural mechanical analysis
Introduction: The Anterior Communicating Artery complex (AComA) is one of the most common intracranial aneurysms locations. Accurate rupture risk assessment in patients with cerebral aneurysms is essential for optimizing treatment decisions. Computational fluid dynamics has significantly advanced insight into aneurysmal hemodynamics. Many studies concentrate predominantly on blood flow patterns, frequently neglecting the biomechanical properties of the aneurysm wall. Fluid-structure interaction analysis combines hemodynamic behavior with wall mechanics, potentially facilitating a more thorough evaluation of rupture risk assessment. Methods: In this study, we employed advanced techniques to investigate several single and composite parameters to predict the rupture risk of AComA aneurysms in a cohort of 150 patients treated at the Kepler University Hospital in Linz, Austria. For this reason, clinical, morphological, hemodynamic, and structural mechanical parameters were assessed. Results: A subsequent workflow analysis, consisting of comparative analysis, collinearity analysis, predictive modeling, composite parameter, performance evaluation, and internal threshold validation, revealed the Gaussian curvature GLN (AUC = 0.91) with a sensitivity of 0.93 and specificity of 0.83 as a best-performing single parameter for aneurysm rupture prediction. Composite parameters like WGD (combination of wall shear stress, Gaussian curvature, and wall displacement) achieved an AUC of 0.89, and WG (combination of wall shear stress and Gaussian curvature) an AUC of 0.88. An internal validation with 25 independent ruptured aneurysms was performed, and the previous results were confirmed with very high sensitivity values of 0.92 for GLN. Conclusion: Our findings indicate that the investigated morphological, hemodynamic, and structural, mechanical parameters could provide a potential tool for evaluating rupture risk for AComA aneurysms. The single morphological parameter GLN offers, followed by composite parameters WGD and WG, excellent prediction power for the aneurysm rupture state, as confirmed by internal validation. Further studies are warranted to evaluate the prospective clinical application of these parameters.
- 2 September 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (9) , e0331297
Open AccessRupture risk assessment for AComA aneurysms with morphological, hemodynamic and structural mechanical analysis
Introduction: The Anterior Communicating Artery complex (AComA) is one of the most common intracranial aneurysms locations. Accurate rupture risk assessment in patients with cerebral aneurysms is essential for optimizing treatment decisions. Computational fluid dynamics has significantly advanced insight into aneurysmal hemodynamics. Many studies concentrate predominantly on blood flow patterns, frequently neglecting the biomechanical properties of the aneurysm wall. Fluid-structure interaction analysis combines hemodynamic behavior with wall mechanics, potentially facilitating a more thorough evaluation of rupture risk assessment. Methods: In this study, we employed advanced techniques to investigate several single and composite parameters to predict the rupture risk of AComA aneurysms in a cohort of 150 patients treated at the Kepler University Hospital in Linz, Austria. For this reason, clinical, morphological, hemodynamic, and structural mechanical parameters were assessed. Results: A subsequent workflow analysis, consisting of comparative analysis, collinearity analysis, predictive modeling, composite parameter, performance evaluation, and internal threshold validation, revealed the Gaussian curvature GLN (AUC = 0.91) with a sensitivity of 0.93 and specificity of 0.83 as a best-performing single parameter for aneurysm rupture prediction. Composite parameters like WGD (combination of wall shear stress, Gaussian curvature, and wall displacement) achieved an AUC of 0.89, and WG (combination of wall shear stress and Gaussian curvature) an AUC of 0.88. An internal validation with 25 independent ruptured aneurysms was performed, and the previous results were confirmed with very high sensitivity values of 0.92 for GLN. Conclusion: Our findings indicate that the investigated morphological, hemodynamic, and structural, mechanical parameters could provide a potential tool for evaluating rupture risk for AComA aneurysms. The single morphological parameter GLN offers, followed by composite parameters WGD and WG, excellent prediction power for the aneurysm rupture state, as confirmed by internal validation. Further studies are warranted to evaluate the prospective clinical application of these parameters.
- Open Access
- 27 September 2024
- Published by MDPI AG in Brain Sciences
- Vol. 14 (10) , 977
Fluid–Structure Interaction Simulations of the Initiation Process of Cerebral Aneurysms
Background: Hemodynamics during the growth process of cerebral aneurysms are incompletely understood. We developed a novel fluid–structure interaction analysis method for the identification of relevant scenarios of aneurysm onset. Method: This method integrates both fluid dynamics and structural mechanics, as well as their mutual interaction, for a comprehensive analysis. Patients with a single unruptured cerebral aneurysm were included. Results: Overall, three scenarios were identified. In scenario A, wall shear stress (WSS) was low, and the oscillatory shear index (OSI) was high in large areas within the region of aneurysm onset (RAO). In scenario B, the quantities indicated a reversed behavior, where WSS was high and OSI was low. In the last scenario C, a behavior in-between was found, with scenarios A and B coexisting simultaneously in the RAO. Structural mechanics demonstrated a similar but independent trend. Further, we analyzed the change in hemodynamics between the onset and a fully developed aneurysm. While scenarios A and C remained unchanged during aneurysm growth, 47% of aneurysms in scenario B changed into scenario A and 20% into scenario C. Conclusions: In conclusion, these findings suggest that WSS and the OSI are reciprocally regulated, and both low and high WSS/OSI conditions can lead to aneurysm onset.
- 27 September 2024
- Published by MDPI AG in Brain Sciences
- Vol. 14 (10) , 977
Open AccessFluid–Structure Interaction Simulations of the Initiation Process of Cerebral Aneurysms
Background: Hemodynamics during the growth process of cerebral aneurysms are incompletely understood. We developed a novel fluid–structure interaction analysis method for the identification of relevant scenarios of aneurysm onset. Method: This method integrates both fluid dynamics and structural mechanics, as well as their mutual interaction, for a comprehensive analysis. Patients with a single unruptured cerebral aneurysm were included. Results: Overall, three scenarios were identified. In scenario A, wall shear stress (WSS) was low, and the oscillatory shear index (OSI) was high in large areas within the region of aneurysm onset (RAO). In scenario B, the quantities indicated a reversed behavior, where WSS was high and OSI was low. In the last scenario C, a behavior in-between was found, with scenarios A and B coexisting simultaneously in the RAO. Structural mechanics demonstrated a similar but independent trend. Further, we analyzed the change in hemodynamics between the onset and a fully developed aneurysm. While scenarios A and C remained unchanged during aneurysm growth, 47% of aneurysms in scenario B changed into scenario A and 20% into scenario C. Conclusions: In conclusion, these findings suggest that WSS and the OSI are reciprocally regulated, and both low and high WSS/OSI conditions can lead to aneurysm onset.
- Open Access
- 1 January 2024
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 11 (1) , 08-13
Analysis of Morphology, Hemodynamics and Structural Mechanics for the Establishment of Growth History of Cerebral Aneurysm
Volume 11, Issue 1 published for JBEB Journal.
- 1 January 2024
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 11 (1) , 08-13
Open AccessAnalysis of Morphology, Hemodynamics and Structural Mechanics for the Establishment of Growth History of Cerebral Aneurysm
Volume 11, Issue 1 published for JBEB Journal.
- Open Access
Modeling of 3D Blood Flows with Physics-Informed Neural Networks: Comparison of Network Architectures
Machine learning-based modeling of physical systems has attracted significant interest in recent years. Based solely on the underlying physical equations and initial and boundary conditions, these new approaches allow to approximate, for example, the complex flow of blood in the case of fluid dynamics. Physics-informed neural networks offer certain advantages compared to conventional computational fluid dynamics methods as they avoid the need for discretized meshes and allow to readily solve inverse problems and integrate additional data into the algorithms. Today, the majority of published reports on learning-based flow modeling relies on fully-connected neural networks. However, many different network architectures are introduced into deep learning each year, each with specific benefits for certain applications. In this paper, we present the first comprehensive comparison of various state-of-the-art networks and evaluate their performance in terms of computational cost and accuracy relative to numerical references. We found that while fully-connected networks offer an attractive balance between training time and accuracy, more elaborate architectures (e.g., Deep Galerkin Method) generated superior results. Moreover, we observed high accuracy in simple cylindrical geometries, but slightly poorer estimates in complex aneurysms. This paper provides quantitative guidance for practitioners interested in complex flow modeling using physics-based deep learning.
Open AccessModeling of 3D Blood Flows with Physics-Informed Neural Networks: Comparison of Network Architectures
Machine learning-based modeling of physical systems has attracted significant interest in recent years. Based solely on the underlying physical equations and initial and boundary conditions, these new approaches allow to approximate, for example, the complex flow of blood in the case of fluid dynamics. Physics-informed neural networks offer certain advantages compared to conventional computational fluid dynamics methods as they avoid the need for discretized meshes and allow to readily solve inverse problems and integrate additional data into the algorithms. Today, the majority of published reports on learning-based flow modeling relies on fully-connected neural networks. However, many different network architectures are introduced into deep learning each year, each with specific benefits for certain applications. In this paper, we present the first comprehensive comparison of various state-of-the-art networks and evaluate their performance in terms of computational cost and accuracy relative to numerical references. We found that while fully-connected networks offer an attractive balance between training time and accuracy, more elaborate architectures (e.g., Deep Galerkin Method) generated superior results. Moreover, we observed high accuracy in simple cylindrical geometries, but slightly poorer estimates in complex aneurysms. This paper provides quantitative guidance for practitioners interested in complex flow modeling using physics-based deep learning.
- Open Access
- 1 January 2023
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 10 (1) , 10-19
Methods, Validation and Clinical Implementation of a Simulation Method of Cerebral Aneurysms
Volume 10, published for JBEB Journal.
- 1 January 2023
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 10 (1) , 10-19
Open AccessMethods, Validation and Clinical Implementation of a Simulation Method of Cerebral Aneurysms
Volume 10, published for JBEB Journal.
- 19 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-12
Elastic Registration of Abdominal MRI Scans and RGB-D Images to Improve Surgical Planning of Breast Reconstruction
MRI and associated contrast agent administration to visualize the vasculature prove valuable for planning surgical interventions and can reduce the operative time by helping to locate internal structures of interest for the operation. However, the visual representation of soft tissues deviates due to differences in body posture, in water and fat content, and in their gravitational displacement. In this paper, we present a novel approach for calculating deformations of abdominal fat tissue and vascular structures in MRI scans. The underlying elastic registration model is based on a current abdominal RGB-D scan as a surface-matching target. We demonstrate the pipeline on Dixon MRI and RGB-D scans acquired from ten patients with a diagnosis of breast cancer and a treatment plan including mastectomy. Results indicate that the proposed system enhances the surgeon's spatial perception of the abdominal vasculature and improves the accuracy of blood vessel locations shown in MRI scans.
- 19 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-12
Elastic Registration of Abdominal MRI Scans and RGB-D Images to Improve Surgical Planning of Breast Reconstruction
MRI and associated contrast agent administration to visualize the vasculature prove valuable for planning surgical interventions and can reduce the operative time by helping to locate internal structures of interest for the operation. However, the visual representation of soft tissues deviates due to differences in body posture, in water and fat content, and in their gravitational displacement. In this paper, we present a novel approach for calculating deformations of abdominal fat tissue and vascular structures in MRI scans. The underlying elastic registration model is based on a current abdominal RGB-D scan as a surface-matching target. We demonstrate the pipeline on Dixon MRI and RGB-D scans acquired from ten patients with a diagnosis of breast cancer and a treatment plan including mastectomy. Results indicate that the proposed system enhances the surgeon's spatial perception of the abdominal vasculature and improves the accuracy of blood vessel locations shown in MRI scans.
- Open Access
- 27 November 2020
- Published by Association for Computing Machinery (ACM)
- p. 89-96
A Content-Driven Architecture for Medical Image Segmentation
As the U-Net architecture continues to push the state of the art in medical image segmentation, and keeping track of the multitude of derived models becomes increasingly difficult, opposing trends have emerged that prefer a coherent framework of ancillary processing tasks over the use of highly optimized and sophisticated models. This trend has culminated in the framework nnU-Net, which adapts preprocessing, training and inference to the respective dataset and thus managed to lead the Medical Segmentation Decathlon challenge despite relying on comparably simple models. In this paper, we focus on one ancillary technique that is commonly used but poorly addressed in literature: patchwise training. Since computational costs tend to increase drastically when using naive strategies, we discuss the benefits of content-sensitive sampling for patchwise training of deep learning segmentation models. We adapt this strategy in a content-driven architecture for abdominal aorta and stent-graft segmentation, where we evaluate and compare it with traditional sampling strategies based on a real-world clinical dataset.
- 27 November 2020
- Published by Association for Computing Machinery (ACM)
- p. 89-96
Open AccessA Content-Driven Architecture for Medical Image Segmentation
As the U-Net architecture continues to push the state of the art in medical image segmentation, and keeping track of the multitude of derived models becomes increasingly difficult, opposing trends have emerged that prefer a coherent framework of ancillary processing tasks over the use of highly optimized and sophisticated models. This trend has culminated in the framework nnU-Net, which adapts preprocessing, training and inference to the respective dataset and thus managed to lead the Medical Segmentation Decathlon challenge despite relying on comparably simple models. In this paper, we focus on one ancillary technique that is commonly used but poorly addressed in literature: patchwise training. Since computational costs tend to increase drastically when using naive strategies, we discuss the benefits of content-sensitive sampling for patchwise training of deep learning segmentation models. We adapt this strategy in a content-driven architecture for abdominal aorta and stent-graft segmentation, where we evaluate and compare it with traditional sampling strategies based on a real-world clinical dataset.
- 27 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 10 (2) , 676-684
Detection of Arc Faults in PV Systems Using Compressed Sensing
- 27 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 10 (2) , 676-684
Detection of Arc Faults in PV Systems Using Compressed Sensing
- 1 April 2018
- Published by Elsevier in World Neurosurgery
- Vol. 112, e313-e323
Virtual Cerebral Aneurysm Clipping with Real-Time Haptic Force Feedback in Neurosurgical Education
- 1 April 2018
- Published by Elsevier in World Neurosurgery
- Vol. 112, e313-e323
Virtual Cerebral Aneurysm Clipping with Real-Time Haptic Force Feedback in Neurosurgical Education