GBGurumoorthy Bhuvaneswari

Gurumoorthy Bhuvaneswari

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gurumoorthy Bhuvaneswari has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Building a Robust Workforce in Electric Power Engineering

    by Siddharth Raju, Ned Mohan, Randall Victora, Aranya Chakrabortty, Lynn J. Petersen, Alton D. Romig, Stan Atcitty, Pramod P. Khargonekar, Ahmed Rubaai, Joan Z. Carter, et al.

    This two-day NSF–NAE workshop brought together educators, government laboratories, industry, and workforce-development partners to advance electric-power engineering education by democratizing access to technical learning. Co-located with the ECE Department Heads Association conference and co-sponsored by Sandia National Laboratories and ECEDHA, it addressed pipeline programs, community-college pathways, scholarship programs, international perspectives, interactive textbooks, and CUSP courses and laboratories.

  • Analysis on Performance Improvement of Current Maintainable Meat Grinder Driving a Railgun

    by Dipta Chaudhuri, Shouri Chatterjee, G. Bhuvaneswari

    A current-maintainable meat grinder (CMMG) is a recent variation of inductive pulsed power supplies (IPPSs) suitable for real-time velocity measurement and control during the railgun launch process. In this work, we analyze a 400-kJ CMMG-driven 0.7-m railgun with the help of 3-D electromagnetic-mechanical coupled simulations and investigate the influence of inductance ratio ( $L_{1}/L_{2}$ ) on the railgun’s muzzle velocity. It is observed that the muzzle velocity rises steadily up to $L_{1}/L_{2}~\approx ~60$ and then nearly saturates, and ≈100 is the optimum value of $L_{1}/L_{2}$ . Also, for input current pulses having the same time constant, the muzzle velocity is seen to vary almost linearly with the current-multiplication factor. We also compare the performance of this 400-kJ CMMG with that of a 400-kJ capacitive pulsed power supply (CPPS) driving an identical 0.7-m railgun. When the inductances of the CPPS and the CMMG are both equal to $34~\mu \text{H}$ , we find that the muzzle velocity of our CMMG-driven railgun is $8.45\times $ compared to the CPPS-driven railgun. When the inductances of the CPPS and the CMMG are, respectively, 34 and $0.34~\mu \text{H}$ , the muzzle velocity of the CMMG-driven railgun is $4.76\times $ compared to the CPPS-driven railgun. The velocity of the CMMG-driven railgun is greater than the CPPS-driven railgun in both cases.


  • Analysis of Conventional Non-isolated Bidirectional Converters with Smooth Transient Operation

    by Ambuj Sharma, Soumya Shubhra Nag, G. Bhuvaneswari

    The objective of this work is to achieve a smooth transient operation of non-isolated bidirectional dc-dc converters (BDCs), by implementing two different PWM schemes for transient and steady-state operations, respectively. These two PWM schemes also facilitate the converter operation in continuous conduction mode (CCM) and discontinuous conduction mode (DCM). The CCM and DCM modes of converter operation enables efficient control over the bidirectional power flow, especially during low power operation. Apart from this, an equation for average inductor current is derived and validated with active sources on both input and output sides. The analysis of the BDCs has been included using the switch average modeling technique. The operation of the proposed PWM schemes and the expression for the steady-state average inductor current are validated in simulation and hardware. The hardware results are obtained at 1.5 kW output power, with an input voltage of 132 V and an output voltage of 330 V for validating the concept.

  • Design of Gate Drive Circuit for Thyristor Stack in Electromagnetic Railgun by Load-Line Analysis

    by Dipta Chaudhuri, Snigdha Dalvi, Mayank Khatri, Shouri Chatterjee, G. Bhuvaneswari

    A gate-drive circuit is presented, which simultaneously triggers high power thyristors for surge current operation in a 400-kJ, $2 \times 3$ series–parallel stack, to be used as a controllable switch in a pulsed power supply (PPS) for a railgun. This type of dynamic application requires high gate current with a large rate of rise. To arrive at the appropriate gate drive circuit, a load line analysis has been done. The point of intersection of this load line with the gate-cathode characteristics of the thyristor theoretically predicts the operating point. The gate triggering circuit is designed such that its Thévenin equivalent circuit corresponds to the load line intercepts. To verify the design, the gate-cathode characteristics of the thyristor have been behaviorally modeled as a diode, and SPICE simulations are performed on the designed triggering circuit with this diode as a load. A peak gate current and a gate-to-cathode voltage of 9 A and 6 V, respectively, are achieved, resulting in a design compliant with ABB 5STP26N6500 surge specifications. The peak rate of rise of gate current obtained is 10 A/ $\mu \text{s}$ . Beyond the 9-A peak, the current pulse starts decaying and remains nonzero up to 160 $\mu \text{s}$ . Circuit configurations having load-lines ranging from (15 V/ $0.96~\Omega $ ) to (45 V/ $4.13~\Omega $ ) are examined, and the load-line with slope (45 V/ $4.13~\Omega $ ) is chosen, because it results in an output current ≤10 A (the maximum allowed gate current) for all temperatures in between maximum dynamic high temperature and minimum temperature of −40°C.


  • A Reliable Microgrid Comprising Solar PV-WEGS and Battery With Seamless Power Transfer Capability

    by Deepu Vijay M, Gurumoorthy Bhuvaneswari, Bhim Singh

    This paper implements a new control method for a microgrid comprising wind energy generation system, solar PV array, the battery, and the utility grid, which provides a seamless transition of power during on-grid to off-grid operations and vice versa. This microgrid uses synchronous reluctance generator controlled by a mechanical position sensor-less field-oriented control, for the electric power generation from a variable speed wind turbine. The output of the solar PV array is connected to the DC-link of the microgrid through a DC-DC boost converter, whose output voltage is regulated at the desired value by the battery bank. For smooth synchronization and fast dynamic response, fourth-order generalized integrator based frequency-locked-loop with pre-filter (C-FGI-FLL) is implemented in this work. The use of C-FGI-FLL enhances the filtering capabilities of FGI-FLL under weak grid conditions, without affecting the computational burden. The C-FGI-FLL generates filtered input and its quadrature component, and these are further used for the extraction of positive sequence components of the grid voltages. For faster dynamic response during load variations, C-FGI filters are used in each phase so that fundamental peaks of load currents are extracted accurately without any delay. This microgrid has been tested both for dynamic and steady-state conditions on a prototype developed in the laboratory.


  • Grid-Tied Battery Integrated Wind Energy Generation System With an Ability to Operate Under Adverse Grid Conditions

    by Deepu Vijay M., Bhim Singh, G. Bhuvaneswari

    An efficient control of a grid integrated microgrid with wind energy generating system (WEGS) and battery storage, is implemented in this work. The quality of power injected to the utility is deteriorated with the level of unbalance and/or distortions present in the grid voltages. To compensate for the abnormalities, such as unbalance and distortions in grid voltages, positive sequence components (PSCs) of grid voltages are extracted from their filtered alpha-beta components. This work implements hybrid generalized integrator (HGI) filters for filtering the alpha-beta components of grid voltages and also provides its 90 degree delayed signals, which are useful in generating PSCs. Phase and frequency of grid currents are decided by the unit active templates derived from PSCs of grid voltages, therefore, high-quality grid currents are injected into the grid even for abnormal grid conditions. For faster dynamics during variations in load power, HGI filters are used for quick and accurate estimation of fundamental components of load currents. Intermittent power generation from WEGS is compensated for by integrating a battery bank into the system. Along with high-quality power injection, the grid side converter (GSC) operates the microgrid in off-grid mode (during grid outages) and provides smooth grid integration once the grid reappears. A 3.7 kW speed sensorless synchronous reluctance generator (SynRG) is used in WEGS, which is controlled by the machine side converter. The control techniques are validated in Matlab/Simulink platform, and experimental validation is done on a prototype developed in the laboratory.


  • Analysis and Transition Techniques for a Bidirectional DC–DC Converter

    by Ambuj Sharma, Soumya Shubhra Nag, G. Bhuvaneswari, Mummadi Veerachary

    This paper proposes two new pulse width modulation (PWM) schemes, namely, asynchronous PWM scheme (APS), and synchronous PWM scheme (SPS), for a non-isolated fourth order bidirectional dc-dc converter (FOBDC), which are implemented to achieve a smooth start-up operation and mode transition to reverse the direction of power flow. The presented FOBDC is reported already in the literature as a unidirectional boost converter, the functionality of which is modified in this work, to enable bidirectional power flow. The FOBDC can operate in either discharging (Mode-I) or charging (Mode-II) mode. The over/undershoot of inductor currents in the FOBDC occur during converter start-up operation in either of the modes and while transitioning modes (from charging to discharging and vice-versa). To eliminate the over/undershoot of inductor current, two effective transition techniques are developed for smooth start-up operation and mode transition, thereby reducing the delay time significantly. The FOBDC is modeled using state-space modeling technique, and duty ratio to inductor current transfer function is derived, which is validated for resistive load and battery load. Two different compensators are designed for these two transfer functions to achieve an average current mode control (ACMC) during the charging and discharging modes of operation. The performance of the compensators is evaluated by introducing perturbations. A 12 V to 48 V FOBDC converter, controlled by these PWM techniques with aforementioned features, is designed, analyzed, and experimentally verified for low power applications.


  • A Novel Electromagnetic Launcher Configuration With Improved System and Barrel Efficiencies

    by S. R. Naga Praneeth, Dipta Chaudhuri, Shouri Chatterjee, G. Bhuvaneswari, Bhim Singh

    In this article, we present a railgun with a combination of narrowed rails and concave armature that is more efficient compared with a standard electromagnetic launcher with rectangular rails and a monolithic ``C'' armature. Electromagnetic-mechanical coupled analysis of LS-DYNA is used to simulate the dynamic field distribution. The performance of the newly designed railgun is evaluated with respect to the conventional railgun of comparable dimensions and the same input energy. A pulse-forming network with realistic cable resistances is modeled to input a pulse current with a peak value of 146 kA to the conventional and newly designed railgun systems. Compared with the conventional electromagnetic railgun (EMRG), the proposed railgun results in 34% larger Lorentz force, 26% greater exit velocity, higher inductance gradient toward muzzle end, and, hence, improved barrel and system efficiency. The system efficiency of the designed railgun is 2.9% compared with 1.6% in conventional railgun. Thus, the configuration of tapered rails and concave armature can provide higher velocity to heavier loads. Also, the projectile can withstand heavier forces that are seen inside the barrel.


  • An Improved Mode Transition Technique for a Non-Isolated Bidirectional DC-DC Converter

    by Ambuj Sharma, Soumya Shubhra Nag, G. Bhuvaneswari, Mummadi Veerachary

    This paper presents the design and analysis of improved mode transition and startup techniques for a DC-DC bidirectional converter (BDC) for battery charging/discharging applications. The BDC inductor current is controlled in such a way that the current reaches its steady state value naturally without any control effort during the transient operation of the converter. The improved mode transition method ensures suppression of large transient currents in either direction by adopting simple control methodology simultaneously reducing the time of mode transition significantly, to the order of time constant of the inductor employed in the converter. This technique is implemented by sensing the direction of inductor current and generating appropriate PWM switching to the bidirectional switches. The startup technique is essential to suppress the current transient during initial response of the BDC for either modes of operation. The start-up and mode transition logic are very effective and easy to implement. A 400 W BDC is designed, analyzed, simulated and experimentally verified for improved mode transition and smooth startup techniques.


  • A High-Performance Microgrid With a Mechanical Sensorless SynRG Operated Wind Energy Generating System

    by Deepu Vijay M., Bhim Singh, Gurumoorthy Bhuvaneswari

    In this work, a new control methodology is implemented for a microgrid consisting of wind-battery and the grid, which operates effectively both under grid-connected mode and standalone mode. A synchronous reluctance generator (SynRG) with a new mechanical sensorless field-oriented control (FOC) is used in the wind energy generation system (WEGS). The major issues present in the sensorless control of SynRG, due to the use of conventional integrator or low pass filter during the flux estimation, are addressed in this work by implementing a fourth order flux estimator (FFE). To compensate for the intermittent nature of the power generated from the WEGS, and to improve the reliability of the system pertaining to power availability, energy storage (ES) is included in the system. Controlled operation of the battery is ensured by using a bidirectional DC-DC converter (BDC), to enhance the longevity of the battery. Voltage source converters (VSCs) connected in a back-to-back configuration with a common DC-link is selected here so that a complete decoupling is achieved between the grid and WEGS. Grid side VSC (GSC) is efficiently controlled, so that power quality at the point of common coupling (PCC) is improved. The positive sequence components (PSC) of grid voltages are extracted using observers to implement GSC control to avoid the adverse effects of unbalance and harmonic content in grid voltages. Design, modelling, and simulation of the system are done in MATLAB/ SIMULINK platform, and a prototype developed in the laboratory, is used for real-time validation.