Michal Fereczkowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michal Fereczkowski has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Tobias Neher
Department of Clinical Research, University of Southern Denmark
9 shared publications - Raul Sanchez-Lopez
Interacoustics Research Unit, Kongens Lyngby, Denmark
6 shared publications - Sébastien Santurette
Centre for Applied Audiology Research, Oticon A/S, Smørum, Denmark
5 shared publications - Torsten Dau
Hearing Systems Section, Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark
5 shared publications - Lukas Jürgensen
University of Southern Denmark
2 shared publications - Mouhamad El-Haj-Ali
Interacoustics A/S, Middelfart, Denmark
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
Sweet-Spot Compression: An Amplification Strategy for Improving Listening Outcomes at Moderate to High Levels
When speech increases in level from moderate to high, speech intelligibility (SI) can decrease. Termed rollover, this phenomenon is neglected during hearing aid (HA) fitting. A previous study introduced “sweet-spot compression” (SSC)—an amplification strategy for preventing rollover and improving listening outcomes at moderate to high levels. SSC aims to place speech in that area of an individual's performance-intensity function where both SI and listening comfort are high—the “sweet spot.” To achieve this, it combines high compression ratios with long time constants to provide quasi-linear amplification in the sweet-spot area. Using a HA simulator, headphone presentation, and 16 participants with rollover, SSC previously outperformed a clinical reference condition in terms of listening outcome. Here, we extended this work by (a) mapping out individual differences in the most comfortable speech level (MCL) and SI in noise at moderate to high levels, and (b) evaluating the listening outcome with SSC further. Using a wearable research HA, we tested 18 randomly chosen participants with mild to moderate hearing loss. Our analyses showed clear individual differences in MCL and SI with linear amplification. SSC gave better SI and was clearly preferred in quiet and in noise relative to a clinical reference condition. At the group level, rollover did not occur for either SSC or the reference condition. At the individual level, we found fewer cases of rollover with SSC than with the reference condition. Overall, we conclude that SSC shows promise with respect to improving listening outcomes at moderate to high levels.
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
Open AccessSweet-Spot Compression: An Amplification Strategy for Improving Listening Outcomes at Moderate to High Levels
When speech increases in level from moderate to high, speech intelligibility (SI) can decrease. Termed rollover, this phenomenon is neglected during hearing aid (HA) fitting. A previous study introduced “sweet-spot compression” (SSC)—an amplification strategy for preventing rollover and improving listening outcomes at moderate to high levels. SSC aims to place speech in that area of an individual's performance-intensity function where both SI and listening comfort are high—the “sweet spot.” To achieve this, it combines high compression ratios with long time constants to provide quasi-linear amplification in the sweet-spot area. Using a HA simulator, headphone presentation, and 16 participants with rollover, SSC previously outperformed a clinical reference condition in terms of listening outcome. Here, we extended this work by (a) mapping out individual differences in the most comfortable speech level (MCL) and SI in noise at moderate to high levels, and (b) evaluating the listening outcome with SSC further. Using a wearable research HA, we tested 18 randomly chosen participants with mild to moderate hearing loss. Our analyses showed clear individual differences in MCL and SI with linear amplification. SSC gave better SI and was clearly preferred in quiet and in noise relative to a clinical reference condition. At the group level, rollover did not occur for either SSC or the reference condition. At the individual level, we found fewer cases of rollover with SSC than with the reference condition. Overall, we conclude that SSC shows promise with respect to improving listening outcomes at moderate to high levels.
- 18 September 2025
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- p. 1-12
Hard of Hearing Listeners Show Rollover at Moderate to High Levels for Speech Materials With and Without Semantic Context Information
Purpose: At low levels, a level increase typically leads to better speech intelligibility (SI) due to more audibility. At high levels, a level increase can lead to poorer SI and, thus, “rollover.” In a previous study conducted with listeners with normal audiometric thresholds, we found rollover with sentences without semantic context but not with semantic context, suggesting that context information can “mask” rollover. Here, we investigated if equivalent results can be found for listeners with elevated audiometric thresholds. Method: SI scores were measured for two groups of older hard of hearing adults with individual linear amplification. Testing was performed in speech-shaped noise with context-rich and context-free sentences. One group was tested at speech levels of 65 and 75 dB SPL. The other group was tested at a level approximating maximal SI, that is, the individual aided most comfortable level (aMCL) + 10 dB, and at 85 dB SPL. Linear mixed-effects models were used to test for level-dependent changes in SI for the two sentence materials. Results: Rollover occurred for both groups and sentence materials. For the measurements made at 65 and 75 dB SPL, SI decreased by 7.1% for both sentence materials. For the measurements made at aMCL +10 dB and 85 dB SPL, SI decreased by 9.3% for the context-free sentences and by 10.4% for the context-rich sentences. Conclusion: Linearly aided hard of hearing listeners show rollover at moderate to high levels for sentence materials with and without semantic context information.
- 18 September 2025
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- p. 1-12
Hard of Hearing Listeners Show Rollover at Moderate to High Levels for Speech Materials With and Without Semantic Context Information
Purpose: At low levels, a level increase typically leads to better speech intelligibility (SI) due to more audibility. At high levels, a level increase can lead to poorer SI and, thus, “rollover.” In a previous study conducted with listeners with normal audiometric thresholds, we found rollover with sentences without semantic context but not with semantic context, suggesting that context information can “mask” rollover. Here, we investigated if equivalent results can be found for listeners with elevated audiometric thresholds. Method: SI scores were measured for two groups of older hard of hearing adults with individual linear amplification. Testing was performed in speech-shaped noise with context-rich and context-free sentences. One group was tested at speech levels of 65 and 75 dB SPL. The other group was tested at a level approximating maximal SI, that is, the individual aided most comfortable level (aMCL) + 10 dB, and at 85 dB SPL. Linear mixed-effects models were used to test for level-dependent changes in SI for the two sentence materials. Results: Rollover occurred for both groups and sentence materials. For the measurements made at 65 and 75 dB SPL, SI decreased by 7.1% for both sentence materials. For the measurements made at aMCL +10 dB and 85 dB SPL, SI decreased by 9.3% for the context-free sentences and by 10.4% for the context-rich sentences. Conclusion: Linearly aided hard of hearing listeners show rollover at moderate to high levels for sentence materials with and without semantic context information.
- Open Access
- 10 April 2024
- Published by The Korean Audiological Society in Journal of Audiology and Otology
- Vol. 28 (2) , 146-152
Comparison of Two Clinical Devices for the Measurement of Distortion Product Otoacoustic Emissions in Normal-Hearing Adults
Background and Objectives: Otoacoustic emissions (OAEs) are low-intensity sounds generated by the cochlea and associated with the function of the outer hair cells. Since OAE measurements do not require active participation of a listener, OAEs are considered an objective measure of cochlear function. While distortion-product OAEs (DPOAEs) are commonly used in clinical practice, limited information is available on the performance of various clinical devices. This study compared two commercial clinical devices, Titan and Eclipse from Interacoustics, and collected normative data for DPOAEs in people with normal hearing. The data collection and analysis were focused on signal and noise amplitudes as well as signal-to-noise ratios (SNRs).Subjects and Methods: Sixty-three participants with normal hearing (age 23.2±2.0 years) were included in the study. DPOAEs were measured at 31 frequencies ranging from 500 to 10,000 Hz.Results: DPOAE amplitude differed across frequencies. Additionally, a high number of unreliable responses were observed at the edge frequencies (6,072 Hz). There were no significant differences between the two devices in terms of DPOAE amplitudes, but the recorded-noise levels (amplitude) differed significantly. SNRs of the recorded OAEs were frequency dependent (higher frequencies showed larger SNRs), and significant differences in terms of SNR were found between the two devices.Conclusions: Despite the above-mentioned differences, the OAEs recorded with both devices met the pass criteria for the SNR (≥6 dB) consistently across frequencies, and thus the differences do not compromise the test outcomes. The frequency dependence of the OAE amplitudes and the corresponding SNRs may be relevant for clinical practice.
- 10 April 2024
- Published by The Korean Audiological Society in Journal of Audiology and Otology
- Vol. 28 (2) , 146-152
Open AccessComparison of Two Clinical Devices for the Measurement of Distortion Product Otoacoustic Emissions in Normal-Hearing Adults
Background and Objectives: Otoacoustic emissions (OAEs) are low-intensity sounds generated by the cochlea and associated with the function of the outer hair cells. Since OAE measurements do not require active participation of a listener, OAEs are considered an objective measure of cochlear function. While distortion-product OAEs (DPOAEs) are commonly used in clinical practice, limited information is available on the performance of various clinical devices. This study compared two commercial clinical devices, Titan and Eclipse from Interacoustics, and collected normative data for DPOAEs in people with normal hearing. The data collection and analysis were focused on signal and noise amplitudes as well as signal-to-noise ratios (SNRs).Subjects and Methods: Sixty-three participants with normal hearing (age 23.2±2.0 years) were included in the study. DPOAEs were measured at 31 frequencies ranging from 500 to 10,000 Hz.Results: DPOAE amplitude differed across frequencies. Additionally, a high number of unreliable responses were observed at the edge frequencies (6,072 Hz). There were no significant differences between the two devices in terms of DPOAE amplitudes, but the recorded-noise levels (amplitude) differed significantly. SNRs of the recorded OAEs were frequency dependent (higher frequencies showed larger SNRs), and significant differences in terms of SNR were found between the two devices.Conclusions: Despite the above-mentioned differences, the OAEs recorded with both devices met the pass criteria for the SNR (≥6 dB) consistently across frequencies, and thus the differences do not compromise the test outcomes. The frequency dependence of the OAE amplitudes and the corresponding SNRs may be relevant for clinical practice.
- Open Access
- 5 January 2024
- Published by SAGE Publications in Trends in Hearing
- Vol. 28
Amplitude Compression for Preventing Rollover at Above-Conversational Speech Levels
Hearing aids provide nonlinear amplification to improve speech audibility and loudness perception. While more audibility typically increases speech intelligibility at low levels, the same is not true for above-conversational levels, where decreases in intelligibility (“rollover”) can occur. In a previous study, we found rollover in speech intelligibility measurements made in quiet for 35 out of 74 test ears with a hearing loss. Furthermore, we found rollover occurrence in quiet to be associated with poorer speech intelligibility in noise as measured with linear amplification. Here, we retested 16 participants with rollover with three amplitude-compression settings. Two were designed to prevent rollover by applying slow- or fast-acting compression with a 5:1 compression ratio around the “sweet spot,” that is, the area in an individual performance-intensity function with high intelligibility and listening comfort. The third, reference setting used gains and compression ratios prescribed by the “National Acoustic Laboratories Non-Linear 1” rule. Speech intelligibility was assessed in quiet and in noise. Pairwise preference judgments were also collected. For speech levels of 70 dB SPL and above, slow-acting sweet-spot compression gave better intelligibility in quiet and noise than the reference setting. Additionally, the participants clearly preferred slow-acting sweet-spot compression over the other settings. At lower levels, the three settings gave comparable speech intelligibility, and the participants preferred the reference setting over both sweet-spot settings. Overall, these results suggest that, for listeners with rollover, slow-acting sweet-spot compression is beneficial at 70 dB SPL and above, while at lower levels clinically established gain targets are more suited.
- 5 January 2024
- Published by SAGE Publications in Trends in Hearing
- Vol. 28
Open AccessAmplitude Compression for Preventing Rollover at Above-Conversational Speech Levels
Hearing aids provide nonlinear amplification to improve speech audibility and loudness perception. While more audibility typically increases speech intelligibility at low levels, the same is not true for above-conversational levels, where decreases in intelligibility (“rollover”) can occur. In a previous study, we found rollover in speech intelligibility measurements made in quiet for 35 out of 74 test ears with a hearing loss. Furthermore, we found rollover occurrence in quiet to be associated with poorer speech intelligibility in noise as measured with linear amplification. Here, we retested 16 participants with rollover with three amplitude-compression settings. Two were designed to prevent rollover by applying slow- or fast-acting compression with a 5:1 compression ratio around the “sweet spot,” that is, the area in an individual performance-intensity function with high intelligibility and listening comfort. The third, reference setting used gains and compression ratios prescribed by the “National Acoustic Laboratories Non-Linear 1” rule. Speech intelligibility was assessed in quiet and in noise. Pairwise preference judgments were also collected. For speech levels of 70 dB SPL and above, slow-acting sweet-spot compression gave better intelligibility in quiet and noise than the reference setting. Additionally, the participants clearly preferred slow-acting sweet-spot compression over the other settings. At lower levels, the three settings gave comparable speech intelligibility, and the participants preferred the reference setting over both sweet-spot settings. Overall, these results suggest that, for listeners with rollover, slow-acting sweet-spot compression is beneficial at 70 dB SPL and above, while at lower levels clinically established gain targets are more suited.
- 20 June 2023
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 66 (6) , 2177-2183
Semantic Context Can Mask Intelligibility Declines at Above-Conversational Speech Levels in Normal-Hearing Listeners
Purpose: While speech audibility generally improves with increasing level, declines in intelligibility are inconsistently observed at above-conversational levels, even in listeners with normal audiograms (NAs). The inconsistent findings could be due to different types of speech materials, ranging from monosyllabic words to everyday sentences, used across studies. Here, we hypothesized that semantic context can “mask” intelligibility declines at high levels by constraining plausible response options. Method: Intelligibility was assessed in speech-shaped noise with monosyllabic words, sentences without semantic context, and sentences with semantic context. Two presentation levels were used: 80 and 95 dB SPL broadband. Bandpass filtering was applied to minimize upward spread of masking. Twenty-two young adults with NAs were tested. Results: Poorer performance at the higher level was found with the monosyllabic words and context-free sentences but not with the context-rich sentences. The scores obtained at the higher level with the two context-free materials were strongly correlated. The correlation was independent of the lower-level scores, suggesting that the high-level performance declines reflect “normal” auditory functioning. Conclusions: Young adults with NAs show intelligibility decreases at above-conversational levels when tested with speech materials without semantic context. Top-down processing as facilitated by context information can mask such declines.
- 20 June 2023
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 66 (6) , 2177-2183
Semantic Context Can Mask Intelligibility Declines at Above-Conversational Speech Levels in Normal-Hearing Listeners
Purpose: While speech audibility generally improves with increasing level, declines in intelligibility are inconsistently observed at above-conversational levels, even in listeners with normal audiograms (NAs). The inconsistent findings could be due to different types of speech materials, ranging from monosyllabic words to everyday sentences, used across studies. Here, we hypothesized that semantic context can “mask” intelligibility declines at high levels by constraining plausible response options. Method: Intelligibility was assessed in speech-shaped noise with monosyllabic words, sentences without semantic context, and sentences with semantic context. Two presentation levels were used: 80 and 95 dB SPL broadband. Bandpass filtering was applied to minimize upward spread of masking. Twenty-two young adults with NAs were tested. Results: Poorer performance at the higher level was found with the monosyllabic words and context-free sentences but not with the context-rich sentences. The scores obtained at the higher level with the two context-free materials were strongly correlated. The correlation was independent of the lower-level scores, suggesting that the high-level performance declines reflect “normal” auditory functioning. Conclusions: Young adults with NAs show intelligibility decreases at above-conversational levels when tested with speech materials without semantic context. Top-down processing as facilitated by context information can mask such declines.
- Open Access
- 9 October 2022
- Published by MDPI AG in Audiology Research
- Vol. 12 (5) , 564-573
Towards Auditory Profile-Based Hearing-Aid Fittings: BEAR Rationale and Clinical Implementation
(1) Background: To improve hearing-aid rehabilitation, the Danish ‘Better hEAring Rehabilitation’ (BEAR) project recently developed methods for individual hearing loss characterization and hearing-aid fitting. Four auditory profiles differing in terms of audiometric hearing loss and supra-threshold hearing abilities were identified. To enable auditory profile-based hearing-aid treatment, a fitting rationale leveraging differences in gain prescription and signal-to-noise (SNR) improvement was developed. This report describes the translation of this rationale to clinical devices supplied by three industrial partners. (2) Methods: Regarding the SNR improvement, advanced feature settings were proposed and verified based on free-field measurements made with an acoustic mannikin fitted with the different hearing aids. Regarding the gain prescription, a clinically feasible fitting tool and procedure based on real-ear gain adjustments were developed. (3) Results: Analyses of the collected real-ear gain and SNR improvement data confirmed the feasibility of the clinical implementation. Differences between the auditory profile-based fitting strategy and a current ‘best practice’ procedure based on the NAL-NL2 fitting rule were verified and are discussed in terms of limitations and future perspectives. (4) Conclusion: Based on a joint effort from academic and industrial partners, the BEAR fitting rationale was transferred to commercially available hearing aids.
- 9 October 2022
- Published by MDPI AG in Audiology Research
- Vol. 12 (5) , 564-573
Open AccessTowards Auditory Profile-Based Hearing-Aid Fittings: BEAR Rationale and Clinical Implementation
(1) Background: To improve hearing-aid rehabilitation, the Danish ‘Better hEAring Rehabilitation’ (BEAR) project recently developed methods for individual hearing loss characterization and hearing-aid fitting. Four auditory profiles differing in terms of audiometric hearing loss and supra-threshold hearing abilities were identified. To enable auditory profile-based hearing-aid treatment, a fitting rationale leveraging differences in gain prescription and signal-to-noise (SNR) improvement was developed. This report describes the translation of this rationale to clinical devices supplied by three industrial partners. (2) Methods: Regarding the SNR improvement, advanced feature settings were proposed and verified based on free-field measurements made with an acoustic mannikin fitted with the different hearing aids. Regarding the gain prescription, a clinically feasible fitting tool and procedure based on real-ear gain adjustments were developed. (3) Results: Analyses of the collected real-ear gain and SNR improvement data confirmed the feasibility of the clinical implementation. Differences between the auditory profile-based fitting strategy and a current ‘best practice’ procedure based on the NAL-NL2 fitting rule were verified and are discussed in terms of limitations and future perspectives. (4) Conclusion: Based on a joint effort from academic and industrial partners, the BEAR fitting rationale was transferred to commercially available hearing aids.
- 25 August 2022
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 44 (1) , 155-166
Predicting Aided Outcome With Aided Word Recognition Scores Measured With Linear Amplification at Above-conversational Levels
Objectives: Many hearing aid (HA) users receive limited benefit from amplification, especially when trying to understand speech in noise, and they often report hearing-related residual activity limitations. Current HA fitting strategies are typically based on pure-tone hearing thresholds only, even though suprathreshold factors have been linked to aided outcomes. Furthermore, clinical measures of speech perception such as word recognition scores (WRSs) are performed without frequency-specific amplification, likely resulting in suboptimal speech audibility and thus inaccurate estimates of suprathreshold hearing abilities. Corresponding measures with frequency-specific amplification (“aided”) would likely improve such estimates and enable more accurate aided outcome prediction. Here, we investigated potential links between either unaided WRSs or aided WRSs measured at several above-conversational levels and two established HA outcome measures: The Hearing-In-Noise Test (HINT) and the International Outcome Inventory for Hearing Aids (IOI-HA). Design: Thirty-seven older individuals with bilateral hearing impairments participated. Two conditions were tested: unaided and aided, with all stimuli presented over headphones. In the unaided condition, the most comfortable level (MCL) for the presented speech stimuli, WRS at MCL+10 dB as well as uncomfortable levels (UCLs) for narrowband noise stimuli were measured. In the aided condition, all stimuli were individually amplified according to the “National Acoustic Laboratories—Revised, Profound” fitting rule. Aided WRSs were then measured using an Interacoustics Affinity system at three above-conversational levels, allowing for the maximum aided WRS as well as the presence of “rollover” in the performance-intensity function to be estimated. Multivariate data analyses were performed to examine the relations between the HINT (measured using a simulated HA with the NAL-RP amplification) or IOI-HA scores (for the participants’ own HAs) and various potential predictors (age, pure-tone average hearing loss, unaided WRS, aided WRS, rollover presence [ROp], and UCL). Results: Aided WRSs predicted the HINT scores better than any other predictor and were also the only significant predictor of the IOI-HA scores. In addition, UCL and ROp in the aided WRSs were significant predictors of the HINT scores and competed for variance in the statistical models. Neither age nor pure-tone average hearing loss could predict the two aided outcomes. Conclusions: Aided WRSs can predict HA outcome more effectively than unaided WRSs, age or pure-tone audiometry and could be relatively easily implemented in clinical settings. More research is necessary to better understand the relations between ROp, UCL and speech recognition at above-conversational levels.
- 25 August 2022
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 44 (1) , 155-166
Predicting Aided Outcome With Aided Word Recognition Scores Measured With Linear Amplification at Above-conversational Levels
Objectives: Many hearing aid (HA) users receive limited benefit from amplification, especially when trying to understand speech in noise, and they often report hearing-related residual activity limitations. Current HA fitting strategies are typically based on pure-tone hearing thresholds only, even though suprathreshold factors have been linked to aided outcomes. Furthermore, clinical measures of speech perception such as word recognition scores (WRSs) are performed without frequency-specific amplification, likely resulting in suboptimal speech audibility and thus inaccurate estimates of suprathreshold hearing abilities. Corresponding measures with frequency-specific amplification (“aided”) would likely improve such estimates and enable more accurate aided outcome prediction. Here, we investigated potential links between either unaided WRSs or aided WRSs measured at several above-conversational levels and two established HA outcome measures: The Hearing-In-Noise Test (HINT) and the International Outcome Inventory for Hearing Aids (IOI-HA). Design: Thirty-seven older individuals with bilateral hearing impairments participated. Two conditions were tested: unaided and aided, with all stimuli presented over headphones. In the unaided condition, the most comfortable level (MCL) for the presented speech stimuli, WRS at MCL+10 dB as well as uncomfortable levels (UCLs) for narrowband noise stimuli were measured. In the aided condition, all stimuli were individually amplified according to the “National Acoustic Laboratories—Revised, Profound” fitting rule. Aided WRSs were then measured using an Interacoustics Affinity system at three above-conversational levels, allowing for the maximum aided WRS as well as the presence of “rollover” in the performance-intensity function to be estimated. Multivariate data analyses were performed to examine the relations between the HINT (measured using a simulated HA with the NAL-RP amplification) or IOI-HA scores (for the participants’ own HAs) and various potential predictors (age, pure-tone average hearing loss, unaided WRS, aided WRS, rollover presence [ROp], and UCL). Results: Aided WRSs predicted the HINT scores better than any other predictor and were also the only significant predictor of the IOI-HA scores. In addition, UCL and ROp in the aided WRSs were significant predictors of the HINT scores and competed for variance in the statistical models. Neither age nor pure-tone average hearing loss could predict the two aided outcomes. Conclusions: Aided WRSs can predict HA outcome more effectively than unaided WRSs, age or pure-tone audiometry and could be relatively easily implemented in clinical settings. More research is necessary to better understand the relations between ROp, UCL and speech recognition at above-conversational levels.
- Open Access
- 16 January 2021
- Published by MDPI AG in Audiology Research
- Vol. 11 (1) , 10-21
Towards Auditory Profile-Based Hearing-Aid Fitting: Fitting Rationale and Pilot Evaluation
Background—The clinical characterization of hearing deficits for hearing-aid fitting purposes is typically based on the pure-tone audiogram only. In a previous study, a group of hearing-impaired listeners completed a comprehensive test battery that was designed to tap into different dimensions of hearing abilities. A data-driven analysis of the data yielded four clinically relevant patient sub-populations or “auditory profiles”. The purpose of the current study was to propose and pilot-test profile-based hearing-aid settings in order to explore their potential for providing more targeted hearing-aid treatment. Methods—Four candidate hearing-aid settings were developed and evaluated by a subset of the participants tested previously. The evaluation consisted of multi-comparison preference ratings that were carried out in realistic sound scenarios. Results—Listeners belonging to the different auditory profiles showed different patterns of preference for the tested hearing-aid settings that were largely consistent with the expectations. Conclusions—The results of this pilot evaluation support further investigations into stratified, profile-based hearing-aid fitting with wearable hearing aids.
- 16 January 2021
- Published by MDPI AG in Audiology Research
- Vol. 11 (1) , 10-21
Open AccessTowards Auditory Profile-Based Hearing-Aid Fitting: Fitting Rationale and Pilot Evaluation
Background—The clinical characterization of hearing deficits for hearing-aid fitting purposes is typically based on the pure-tone audiogram only. In a previous study, a group of hearing-impaired listeners completed a comprehensive test battery that was designed to tap into different dimensions of hearing abilities. A data-driven analysis of the data yielded four clinically relevant patient sub-populations or “auditory profiles”. The purpose of the current study was to propose and pilot-test profile-based hearing-aid settings in order to explore their potential for providing more targeted hearing-aid treatment. Methods—Four candidate hearing-aid settings were developed and evaluated by a subset of the participants tested previously. The evaluation consisted of multi-comparison preference ratings that were carried out in realistic sound scenarios. Results—Listeners belonging to the different auditory profiles showed different patterns of preference for the tested hearing-aid settings that were largely consistent with the expectations. Conclusions—The results of this pilot evaluation support further investigations into stratified, profile-based hearing-aid fitting with wearable hearing aids.
- Open Access
- 1 January 2021
- Published by SAGE Publications in Trends in Hearing
- Vol. 25
Comparison of Behavioral and Physiological Measures of the Status of the Cochlear Nonlinearity
While an audiogram is a useful method of characterizing hearing loss, it has been suggested that including a complementary, suprathreshold measure, for example, a measure of the status of the cochlear active mechanism, could lead to improved diagnostics and improved hearing-aid fitting in individual listeners. While several behavioral and physiological methods have been proposed to measure the cochlear-nonlinearity characteristics, evidence of a good correspondence between them is lacking, at least in the case of hearing-impaired listeners. If this lack of correspondence is due to, for example, limited reliability of one of such measures, it might be a reason for limited evidence of the benefit of measuring peripheral compression. The aim of this study was to investigate the relation between measures of the peripheral-nonlinearity status estimated using two psychoacoustical methods (based on the notched-noise and temporal-masking curve methods) and otoacoustic emissions, on a large sample of hearing-impaired listeners. While the relation between the estimates from the notched-noise and the otoacoustic emissions experiments was found to be stronger than predicted by the audiogram alone, the relations between the two measures and the temporal-masking based measure did not show the same pattern, that is, the variance shared by any of the two measures with the temporal-masking curve-based measure was also shared with the audiogram.
- 1 January 2021
- Published by SAGE Publications in Trends in Hearing
- Vol. 25
Open AccessComparison of Behavioral and Physiological Measures of the Status of the Cochlear Nonlinearity
While an audiogram is a useful method of characterizing hearing loss, it has been suggested that including a complementary, suprathreshold measure, for example, a measure of the status of the cochlear active mechanism, could lead to improved diagnostics and improved hearing-aid fitting in individual listeners. While several behavioral and physiological methods have been proposed to measure the cochlear-nonlinearity characteristics, evidence of a good correspondence between them is lacking, at least in the case of hearing-impaired listeners. If this lack of correspondence is due to, for example, limited reliability of one of such measures, it might be a reason for limited evidence of the benefit of measuring peripheral compression. The aim of this study was to investigate the relation between measures of the peripheral-nonlinearity status estimated using two psychoacoustical methods (based on the notched-noise and temporal-masking curve methods) and otoacoustic emissions, on a large sample of hearing-impaired listeners. While the relation between the estimates from the notched-noise and the otoacoustic emissions experiments was found to be stronger than predicted by the audiogram alone, the relations between the two measures and the temporal-masking based measure did not show the same pattern, that is, the variance shared by any of the two measures with the temporal-masking curve-based measure was also shared with the audiogram.
- Open Access
Auditory Profile-based Hearing-aid Fitting: A Proof-Of-Concept Study
Objective: The clinical characterization of hearing deficits for hearing-aid fitting purposes is typically based on the pure-tone audiogram only. In a previous study, a group of hearing-impaired listeners were tested using a comprehensive test battery designed to tap into different aspects of hearing. A data-driven analysis of the data yielded four clinically relevant patient subpopulations or “auditory profiles”. In the current study, profile-based hearing-aid settings were proposed and evaluated to explore their potential for providing more targeted hearing-aid treatment. Design: Four candidate hearing-aid settings were implemented and evaluated by a subset of the participants tested previously. The evaluation consisted of multi-comparison preference ratings carried out in realistic sound scenarios. Results: Listeners belonging to the different auditory profiles showed different patterns of preference for the tested hearing-aid settings that were largely consistent with the expectations. Conclusion: The results of this proof-of-concept study support further investigations into stratified, profile-based hearing-aid fitting with wearable hearing aids.
Open AccessAuditory Profile-based Hearing-aid Fitting: A Proof-Of-Concept Study
Objective: The clinical characterization of hearing deficits for hearing-aid fitting purposes is typically based on the pure-tone audiogram only. In a previous study, a group of hearing-impaired listeners were tested using a comprehensive test battery designed to tap into different aspects of hearing. A data-driven analysis of the data yielded four clinically relevant patient subpopulations or “auditory profiles”. In the current study, profile-based hearing-aid settings were proposed and evaluated to explore their potential for providing more targeted hearing-aid treatment. Design: Four candidate hearing-aid settings were implemented and evaluated by a subset of the participants tested previously. The evaluation consisted of multi-comparison preference ratings carried out in realistic sound scenarios. Results: Listeners belonging to the different auditory profiles showed different patterns of preference for the tested hearing-aid settings that were largely consistent with the expectations. Conclusion: The results of this proof-of-concept study support further investigations into stratified, profile-based hearing-aid fitting with wearable hearing aids.