Mengfan Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mengfan Wu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Tobias Neher
Department of Clinical Research, University of Southern Denmark
4 shared publications Michal Fereczkowski
Institute of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark
3 shared publications- Mouhamad El-Haj-Ali
Interacoustics A/S, Middelfart, Denmark
2 shared publications - Raul Sanchez-Lopez
Interacoustics Research Unit, Kongens Lyngby, Denmark
2 shared publications - Federica Bianchi
Centre for Applied Audiology Research, Oticon A/S, Smørum, Denmark
1 shared publication - Jesper Hvass Schmidt
Research Unit for ORL – Head & Neck Surgery and Audiology, Odense University Hospital, Odense, Denmark, University of Southern Denmark
1 shared publication
Latest Publications
- Open Access
- 9 August 2022
- Published by SAGE Publications in Trends in Hearing
- Vol. 26
Revisiting Auditory Profiling: Can Cognitive Factors Improve the Prediction of Aided Speech-in-Noise Outcome?
Hearing aids (HA) are the most common type of rehabilitation treatment for age-related hearing loss. However, HA users often obtain limited benefit from their devices, particularly in noisy environments, and thus many HA candidates do not use them at all. A possible reason for this could be that current HA fittings are audiogram-based, that is, they neglect supra-threshold factors. In an earlier study, an auditory-profiling method was proposed as a basis for more personalized HA fittings. This method classifies HA users into four profiles that differ in terms of hearing sensitivity and supra-threshold hearing abilities. Previously, HA users belonging to these profiles showed significant differences in terms of speech recognition in noise but not subjective assessments of speech-in-noise (SIN) outcome. Moreover, large individual differences within some profiles were observed. The current study therefore explored if cognitive factors can help explain these differences and improve aided outcome prediction. Thirty-nine older HA users completed sets of auditory and SIN tests as well as two tablet-based cognitive measures (the Corsi block-tapping and trail-making tests). Principal component analyses were applied to extract the dominant sources of variance both within individual tests producing many variables and within the three types of tests. Multiple linear regression analyses performed on the extracted components showed that auditory factors were related to aided speech recognition in noise but not to subjective SIN outcome. Cognitive factors were unrelated to aided SIN outcome. Overall, these findings provide limited support for adding those two cognitive tests to the profiling of HA users.
- 9 August 2022
- Published by SAGE Publications in Trends in Hearing
- Vol. 26
Open AccessRevisiting Auditory Profiling: Can Cognitive Factors Improve the Prediction of Aided Speech-in-Noise Outcome?
Hearing aids (HA) are the most common type of rehabilitation treatment for age-related hearing loss. However, HA users often obtain limited benefit from their devices, particularly in noisy environments, and thus many HA candidates do not use them at all. A possible reason for this could be that current HA fittings are audiogram-based, that is, they neglect supra-threshold factors. In an earlier study, an auditory-profiling method was proposed as a basis for more personalized HA fittings. This method classifies HA users into four profiles that differ in terms of hearing sensitivity and supra-threshold hearing abilities. Previously, HA users belonging to these profiles showed significant differences in terms of speech recognition in noise but not subjective assessments of speech-in-noise (SIN) outcome. Moreover, large individual differences within some profiles were observed. The current study therefore explored if cognitive factors can help explain these differences and improve aided outcome prediction. Thirty-nine older HA users completed sets of auditory and SIN tests as well as two tablet-based cognitive measures (the Corsi block-tapping and trail-making tests). Principal component analyses were applied to extract the dominant sources of variance both within individual tests producing many variables and within the three types of tests. Multiple linear regression analyses performed on the extracted components showed that auditory factors were related to aided speech recognition in noise but not to subjective SIN outcome. Cognitive factors were unrelated to aided SIN outcome. Overall, these findings provide limited support for adding those two cognitive tests to the profiling of HA users.
- Open Access
- 1 January 2021
- Published by SAGE Publications in Trends in Hearing
- Vol. 25
Influence of Three Auditory Profiles on Aided Speech Perception in Different Noise Scenarios
Hearing aid (HA) users differ greatly in their speech-in-noise (SIN) outcomes. This could be because the degree to which current HA fittings can address individual listening needs differs across users and listening situations. In two earlier studies, an auditory test battery and a data-driven method were developed for classifying HA candidates into four distinct auditory profiles differing in audiometric hearing loss and suprathreshold hearing abilities. This study explored aided SIN outcome for three of these profiles in different noise scenarios. Thirty-one older habitual HA users and six young normal-hearing listeners participated. Two SIN tasks were administered: a speech recognition task and a “just follow conversation” task requiring the participants to self-adjust the target-speech level. Three noise conditions were tested: stationary speech-shaped noise, speech-shaped babble noise, and speech-shaped babble noise with competing dialogues. Each HA user was fitted with three HAs from different manufacturers using their recommended procedures. Real-ear measurements were performed to document the final gain settings. The results showed that HA users with mild hearing deficits performed better than HA users with pronounced hearing deficits on the speech recognition task but not the just follow conversation task. Moreover, participants with pronounced hearing deficits obtained different SIN outcomes with the tested HAs, which appeared to be related to differences in HA gain. Overall, these findings imply that current proprietary fitting strategies are limited in their ability to ensure good SIN outcomes, especially for users with pronounced hearing deficits, for whom the choice of device seems most consequential.
- 1 January 2021
- Published by SAGE Publications in Trends in Hearing
- Vol. 25
Open AccessInfluence of Three Auditory Profiles on Aided Speech Perception in Different Noise Scenarios
Hearing aid (HA) users differ greatly in their speech-in-noise (SIN) outcomes. This could be because the degree to which current HA fittings can address individual listening needs differs across users and listening situations. In two earlier studies, an auditory test battery and a data-driven method were developed for classifying HA candidates into four distinct auditory profiles differing in audiometric hearing loss and suprathreshold hearing abilities. This study explored aided SIN outcome for three of these profiles in different noise scenarios. Thirty-one older habitual HA users and six young normal-hearing listeners participated. Two SIN tasks were administered: a speech recognition task and a “just follow conversation” task requiring the participants to self-adjust the target-speech level. Three noise conditions were tested: stationary speech-shaped noise, speech-shaped babble noise, and speech-shaped babble noise with competing dialogues. Each HA user was fitted with three HAs from different manufacturers using their recommended procedures. Real-ear measurements were performed to document the final gain settings. The results showed that HA users with mild hearing deficits performed better than HA users with pronounced hearing deficits on the speech recognition task but not the just follow conversation task. Moreover, participants with pronounced hearing deficits obtained different SIN outcomes with the tested HAs, which appeared to be related to differences in HA gain. Overall, these findings imply that current proprietary fitting strategies are limited in their ability to ensure good SIN outcomes, especially for users with pronounced hearing deficits, for whom the choice of device seems most consequential.
- Open Access
Auditory tests for characterizing hearing deficits in listeners with various hearing abilities: The BEAR test battery
The Better hEAring Rehabilitation (BEAR) project aims to provide a new clinical profiling tool – a test battery – for hearing loss characterization. Whereas the loss of sensitivity can be efficiently measured using pure-tone audiometry, the assessment of supra-threshold hearing deficits remains a challenge. In contrast to the classical ‘attenuation-distortion’ model, the proposed BEAR approach is based on the hypothesis that the hearing abilities of a given listener can be characterized along two dimensions, reflecting independent types of perceptual deficits (distortions). A data-driven approach provided evidence for the existence of different auditory profiles with different degrees of distortions. Ten tests were included in a test battery, based on their clinical feasibility, time efficiency and related evidence from the literature. The tests were divided into six categories: audibility, speech perception, binaural processing abilities, loudness perception, spectro-temporal modulation sensitivity and spectro-temporal resolution. Seventy-five listeners with symmetric, mild-to-severe sensorineural hearing loss were selected from a clinical population. The analysis of the results showed interrelations among outcomes related to high-frequency processing and outcome measures related to low-frequency processing abilities. The results showed the ability of the tests to reveal differences among individuals and their potential use in clinical settings.
Open AccessAuditory tests for characterizing hearing deficits in listeners with various hearing abilities: The BEAR test battery
The Better hEAring Rehabilitation (BEAR) project aims to provide a new clinical profiling tool – a test battery – for hearing loss characterization. Whereas the loss of sensitivity can be efficiently measured using pure-tone audiometry, the assessment of supra-threshold hearing deficits remains a challenge. In contrast to the classical ‘attenuation-distortion’ model, the proposed BEAR approach is based on the hypothesis that the hearing abilities of a given listener can be characterized along two dimensions, reflecting independent types of perceptual deficits (distortions). A data-driven approach provided evidence for the existence of different auditory profiles with different degrees of distortions. Ten tests were included in a test battery, based on their clinical feasibility, time efficiency and related evidence from the literature. The tests were divided into six categories: audibility, speech perception, binaural processing abilities, loudness perception, spectro-temporal modulation sensitivity and spectro-temporal resolution. Seventy-five listeners with symmetric, mild-to-severe sensorineural hearing loss were selected from a clinical population. The analysis of the results showed interrelations among outcomes related to high-frequency processing and outcome measures related to low-frequency processing abilities. The results showed the ability of the tests to reveal differences among individuals and their potential use in clinical settings.
- Open Access
- 1 January 2020
- Published by SAGE Publications in Trends in Hearing
- Vol. 24
Investigating the Effects of Four Auditory Profiles on Speech Recognition, Overall Quality, and Noise Annoyance With Simulated Hearing-Aid Processing Strategies
Effective hearing aid (HA) rehabilitation requires personalization of the HA fitting parameters, but in current clinical practice only the gain prescription is typically individualized. To optimize the fitting process, advanced HA settings such as noise reduction and microphone directionality can also be tailored to individual hearing deficits. In two earlier studies, an auditory test battery and a data-driven approach that allow classifying hearing-impaired listeners into four auditory profiles were developed. Because these profiles were found to be characterized by markedly different hearing abilities, it was hypothesized that more tailored HA fittings would lead to better outcomes for such listeners. Here, we explored potential interactions between the four auditory profiles and HA outcome as assessed with three different measures (speech recognition, overall quality, and noise annoyance) and six HA processing strategies with various noise reduction, directionality, and compression settings. Using virtual acoustics, a realistic speech-in-noise environment was simulated. The stimuli were generated using a HA simulator and presented to 49 habitual HA users who had previously been profiled. The four auditory profiles differed clearly in terms of their mean aided speech reception thresholds, thereby implying different needs in terms of signal-to-noise ratio improvement. However, no clear interactions with the tested HA processing strategies were found. Overall, these findings suggest that the auditory profiles can capture some of the individual differences in HA processing needs and that further research is required to identify suitable HA solutions for them.
- 1 January 2020
- Published by SAGE Publications in Trends in Hearing
- Vol. 24
Open AccessInvestigating the Effects of Four Auditory Profiles on Speech Recognition, Overall Quality, and Noise Annoyance With Simulated Hearing-Aid Processing Strategies
Effective hearing aid (HA) rehabilitation requires personalization of the HA fitting parameters, but in current clinical practice only the gain prescription is typically individualized. To optimize the fitting process, advanced HA settings such as noise reduction and microphone directionality can also be tailored to individual hearing deficits. In two earlier studies, an auditory test battery and a data-driven approach that allow classifying hearing-impaired listeners into four auditory profiles were developed. Because these profiles were found to be characterized by markedly different hearing abilities, it was hypothesized that more tailored HA fittings would lead to better outcomes for such listeners. Here, we explored potential interactions between the four auditory profiles and HA outcome as assessed with three different measures (speech recognition, overall quality, and noise annoyance) and six HA processing strategies with various noise reduction, directionality, and compression settings. Using virtual acoustics, a realistic speech-in-noise environment was simulated. The stimuli were generated using a HA simulator and presented to 49 habitual HA users who had previously been profiled. The four auditory profiles differed clearly in terms of their mean aided speech reception thresholds, thereby implying different needs in terms of signal-to-noise ratio improvement. However, no clear interactions with the tested HA processing strategies were found. Overall, these findings suggest that the auditory profiles can capture some of the individual differences in HA processing needs and that further research is required to identify suitable HA solutions for them.