S. Kalhan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
S. Kalhan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Balasubramaniam Ramana
Calcutta Medical Research Institute, Kolkata, India
3 shared publications - M. Khetan
Department of Minimal Access and Bariatric Surgery, Sir Ganga Ram Hospital, New Delhi, India
3 shared publications - SuvirajJ John
Department of Minimal Access and Bariatric Surgery, Sir Ganga Ram Hospital, New Delhi, India
3 shared publications - Ashish Dey
Department of General and Laparoscopic Surgery, Sir Ganga Ram Hospital, New Delhi, India
2 shared publications - Tarun Mittal
Department of Laparoscopic, Laser and General Surgery, Sir Ganga Ram Hospital, New Delhi, India
2 shared publications - Vinod Kumar Malik
Department of General and Laparoscopic Surgery, Sir Ganga Ram Hospital, New Delhi, India
2 shared publications
Latest Publications
- 10 September 2022
- Published by Springer Nature in Hernia
- Vol. 26 (5) , 1325-1336
MIS retromuscular repair of lateral incisional hernia: technological deliberations and short-term outcome
Background Lateral abdominal wall hernias (LAWH) constitute about 1–4% of hernia surgical procedures. They represent a unique surgical challenge on account of their potential for anatomical complexity and consequent operative technical demand. Furthermore, LAWH repairs are currently not standardized, and remain contentious, despite a variety of approaches. These repairs are attendant with not insignificant morbidity and recurrence rates. We profile here our endoscopic and hybrid surgical approach to the management of LAWH and early therapeutic outcomes. Methods A retrospective review of our hernia clinical database between March 2018 and December 2020 was performed to extract all LAWH (with and without an associated midline component) patients, who underwent an enhanced-view totally extra peritoneal (eTEP) hernia repair with a transversus abdominis release (TAR), or a hybrid repair. Initial outcome data (6-month follow-up) is profiled here. The primary outcome measures were hernia recurrence and hernia-site bulging. The secondary measures were surgical site occurrence (SSO) and hernia-related quality of life (QoL). Results A total of 33 LAWH patients underwent an eTEP TAR or hybrid hernia repair. 11 patients had an associated midline defect and 12 were recurrent hernias. The mean hernia defect area was 84.2 ± 49 cm2 and mean mesh size was 859.6 ± 263 cm2. There was no hernia recurrence at initial follow-up of 24 months. The SSO rate was 12%. The CCS QoL scores were 34.6 ± 2 pre-operatively, and improved to 27.2 ± 4 at 6 months. Conclusions Our endoscopic and hybrid technique is a safe, reproducible, and technically promising approach for the repair of LAWH. Thorough knowledge of the surgical anatomy of the lateral abdominal wall and advanced endosurgical skills are imperative for good outcomes. We await the long-term results of our LAWH cohort to confirm the findings.
- 10 September 2022
- Published by Springer Nature in Hernia
- Vol. 26 (5) , 1325-1336
MIS retromuscular repair of lateral incisional hernia: technological deliberations and short-term outcome
Background Lateral abdominal wall hernias (LAWH) constitute about 1–4% of hernia surgical procedures. They represent a unique surgical challenge on account of their potential for anatomical complexity and consequent operative technical demand. Furthermore, LAWH repairs are currently not standardized, and remain contentious, despite a variety of approaches. These repairs are attendant with not insignificant morbidity and recurrence rates. We profile here our endoscopic and hybrid surgical approach to the management of LAWH and early therapeutic outcomes. Methods A retrospective review of our hernia clinical database between March 2018 and December 2020 was performed to extract all LAWH (with and without an associated midline component) patients, who underwent an enhanced-view totally extra peritoneal (eTEP) hernia repair with a transversus abdominis release (TAR), or a hybrid repair. Initial outcome data (6-month follow-up) is profiled here. The primary outcome measures were hernia recurrence and hernia-site bulging. The secondary measures were surgical site occurrence (SSO) and hernia-related quality of life (QoL). Results A total of 33 LAWH patients underwent an eTEP TAR or hybrid hernia repair. 11 patients had an associated midline defect and 12 were recurrent hernias. The mean hernia defect area was 84.2 ± 49 cm2 and mean mesh size was 859.6 ± 263 cm2. There was no hernia recurrence at initial follow-up of 24 months. The SSO rate was 12%. The CCS QoL scores were 34.6 ± 2 pre-operatively, and improved to 27.2 ± 4 at 6 months. Conclusions Our endoscopic and hybrid technique is a safe, reproducible, and technically promising approach for the repair of LAWH. Thorough knowledge of the surgical anatomy of the lateral abdominal wall and advanced endosurgical skills are imperative for good outcomes. We await the long-term results of our LAWH cohort to confirm the findings.
- 19 April 2021
- Published by Springer Nature in Hernia
- Vol. 25 (6) , 1739
Correction to: e-TEP repair for midline primary and incisional hernia: technical considerations and initial experience
- 19 April 2021
- Published by Springer Nature in Hernia
- Vol. 25 (6) , 1739
Correction to: e-TEP repair for midline primary and incisional hernia: technical considerations and initial experience
- 7 April 2021
- Published by Springer Nature in Hernia
- Vol. 25 (6) , 1635-1646
e-TEP repair for midline primary and incisional hernia: technical considerations and initial experience
Introduction The Enhanced-View Totally Extra Peritoneal Rives-Stoppa (e-TEP-RS) Technique for the repair of large, complex, ventral abdominal hernias has gained popularity especially in overcoming the disadvantages with Intra Peritoneal Onlay Mesh (IPOM) repairs and to enable siting of a large prosthetic mesh in an anatomical plane distinct from the abdominal cavity and its contents. Evolving variations of the original technique have allowed the definitive repair of such defects in a reproducible manner. We present our initial experience of this approach and detailed steps of our native technical modifications in overcoming the challenges in performing this complex and potentially challenging procedure. Materials and methods This is a retrospective review of the clinical data of midline, large, complex, ventral abdominal hernia patients who underwent e-TEP-RS with and without Transversus Abdominis Release (TAR). Patients, with or without Diastasis of Rectus Abdominis Muscle (DRAM) were included. Key outcomes measured were post-operative pain, operative morbidity, readmission, Quality of Life (QoL), hernia recurrence. Results A total of 58 midline, ventral abdominal hernia patients who underwent e-TEP-RS with and without Transversus Abdominis Release (TAR), between March 2018 and December 2019 were studied. Mean defect area was 41.0 ± 28 cm2 and the mean mesh surface area was 473.5 ± 165 cm2. e-TEP-RS was done in 35 cases, e-TEP RS TAR in 15 cases and e-TEP-RS with e-TEP inguinal in 08 cases. There was no intraoperative morbidity. Mean duration of surgery was 156.2 ± 40 min and mean blood loss was 40.5 ± 26 cc. The CCS QoL scores improved from 34.6 (± 2) pre-operatively to 27.2 (± 4) at the end of 6 months. One patient had a supra-umbilical recurrence following bilateral TAR over the superior edge of the mesh. Follow-up ranged from 6 to 22 months, with a mean of 14 months. Major complications (n = 12; 20.7%) were seroma formation and prolonged ileus. Conclusion The e-TEP-RS technique for large, complex, midline, ventral abdominal hernias can be used with excellent results and acceptable morbidity. This technique is technically challenging and should be mastered in relatively smaller ventral hernias to achieve good results before attempting it in larger, complex ones.
- 7 April 2021
- Published by Springer Nature in Hernia
- Vol. 25 (6) , 1635-1646
e-TEP repair for midline primary and incisional hernia: technical considerations and initial experience
Introduction The Enhanced-View Totally Extra Peritoneal Rives-Stoppa (e-TEP-RS) Technique for the repair of large, complex, ventral abdominal hernias has gained popularity especially in overcoming the disadvantages with Intra Peritoneal Onlay Mesh (IPOM) repairs and to enable siting of a large prosthetic mesh in an anatomical plane distinct from the abdominal cavity and its contents. Evolving variations of the original technique have allowed the definitive repair of such defects in a reproducible manner. We present our initial experience of this approach and detailed steps of our native technical modifications in overcoming the challenges in performing this complex and potentially challenging procedure. Materials and methods This is a retrospective review of the clinical data of midline, large, complex, ventral abdominal hernia patients who underwent e-TEP-RS with and without Transversus Abdominis Release (TAR). Patients, with or without Diastasis of Rectus Abdominis Muscle (DRAM) were included. Key outcomes measured were post-operative pain, operative morbidity, readmission, Quality of Life (QoL), hernia recurrence. Results A total of 58 midline, ventral abdominal hernia patients who underwent e-TEP-RS with and without Transversus Abdominis Release (TAR), between March 2018 and December 2019 were studied. Mean defect area was 41.0 ± 28 cm2 and the mean mesh surface area was 473.5 ± 165 cm2. e-TEP-RS was done in 35 cases, e-TEP RS TAR in 15 cases and e-TEP-RS with e-TEP inguinal in 08 cases. There was no intraoperative morbidity. Mean duration of surgery was 156.2 ± 40 min and mean blood loss was 40.5 ± 26 cc. The CCS QoL scores improved from 34.6 (± 2) pre-operatively to 27.2 (± 4) at the end of 6 months. One patient had a supra-umbilical recurrence following bilateral TAR over the superior edge of the mesh. Follow-up ranged from 6 to 22 months, with a mean of 14 months. Major complications (n = 12; 20.7%) were seroma formation and prolonged ileus. Conclusion The e-TEP-RS technique for large, complex, midline, ventral abdominal hernias can be used with excellent results and acceptable morbidity. This technique is technically challenging and should be mastered in relatively smaller ventral hernias to achieve good results before attempting it in larger, complex ones.