Yongli Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yongli Zhu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Xin Shi
Energy Internet Research Institute, Tsinghua University, Beijing, China
3 shared publications Lijuan Zhao
2 shared publications- Robert Caiming Qiu
Huazhong University of Science and Technology
2 shared publications - Xuechun Liu
Beijing Engineering Research Center of High-Rise and Large-Span Pre-Stressed Steel Structures, Beijing University of Technology, Beijing 100124, China
2 shared publications Yafei Jia
State Key Laboratory of Alternate Electrical Power System with RenewableEnergy Sources North China Electric Power University Baoding 071003 People's Republic ofChina
2 shared publicationsYonghui Chen
2 shared publications
Latest Publications
- 25 August 2026
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 207
An accurate spontaneous Brillouin scattering spectrum noise model and its validation
- 25 August 2026
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 207
An accurate spontaneous Brillouin scattering spectrum noise model and its validation
- 11 November 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (11) , 117001
Effect of single-mode fiber bending on the accuracy of optical fiber distributed sensing based on Brillouin scattering
This note investigates the effect of optical fiber bending on the Brillouin gain spectrum (BGS) power loss and Brillouin frequency shift (BFS) error. Firstly, the formula for calculating BGS bending loss is derived and verified with experimental data. In addition, by analyzing both simulation and experimental data, to our knowledge, for the first time, an estimation formula for the BFS error caused by optical fiber bending is proposed. Using this formula, the BFS error after fiber bending can be calculated based on the BFS error before fiber bending, core radius, core refractive index, cladding refractive index, bending radius and length. Furthermore, the proposed formula is validated through experimental data. The maximum relative error is 27.63%, and the average relative error is 14.80%.
- 11 November 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (11) , 117001
Effect of single-mode fiber bending on the accuracy of optical fiber distributed sensing based on Brillouin scattering
This note investigates the effect of optical fiber bending on the Brillouin gain spectrum (BGS) power loss and Brillouin frequency shift (BFS) error. Firstly, the formula for calculating BGS bending loss is derived and verified with experimental data. In addition, by analyzing both simulation and experimental data, to our knowledge, for the first time, an estimation formula for the BFS error caused by optical fiber bending is proposed. Using this formula, the BFS error after fiber bending can be calculated based on the BFS error before fiber bending, core radius, core refractive index, cladding refractive index, bending radius and length. Furthermore, the proposed formula is validated through experimental data. The maximum relative error is 27.63%, and the average relative error is 14.80%.
- 8 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3386-3395
Dissolved Gas Analysis for Power Transformer Fault Diagnosis Combining Domain Knowledge and Capsule Network
As the types and concentration of dissolved gases in oil are different when a power transformer operates in different conditions, dissolved gas analysis (DGA) has become a basic means for power transformer fault diagnosis. To further improve diagnosis accuracy and reliability, a new approach combining domain knowledge and capsule network is proposed in this paper. Firstly, new knowledge features based on the principle of ratio methods are constructed and used as the input of the capsule network, in which the knowledge can offer restrictions and guidance for training the capsule network. Then the capsule network based diagnosis model is built, which uses capsule (vector) instead of node (scalar) as the fundamental unit and is capable of extracting intricate and subtle patterns in the input data. Combining the advantages of knowledge-driven and data-driven approaches, the proposed approach achieves diagnosis accuracies of 92.11% and 94.02% on the real-world DGA data and IEC TC10 database, respectively, which attains a more than 10 percent increase compared with the typical purely data-driven or knowledge-driven diagnosis approaches. Meanwhile, the diagnostic accuracy reaches 83.98% even when utilizing only 10% of the original training set for the capsule network training and it increases steadily with the increasing proportion, which validates the strong stability and reliability of the proposed approach.
- 8 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3386-3395
Dissolved Gas Analysis for Power Transformer Fault Diagnosis Combining Domain Knowledge and Capsule Network
As the types and concentration of dissolved gases in oil are different when a power transformer operates in different conditions, dissolved gas analysis (DGA) has become a basic means for power transformer fault diagnosis. To further improve diagnosis accuracy and reliability, a new approach combining domain knowledge and capsule network is proposed in this paper. Firstly, new knowledge features based on the principle of ratio methods are constructed and used as the input of the capsule network, in which the knowledge can offer restrictions and guidance for training the capsule network. Then the capsule network based diagnosis model is built, which uses capsule (vector) instead of node (scalar) as the fundamental unit and is capable of extracting intricate and subtle patterns in the input data. Combining the advantages of knowledge-driven and data-driven approaches, the proposed approach achieves diagnosis accuracies of 92.11% and 94.02% on the real-world DGA data and IEC TC10 database, respectively, which attains a more than 10 percent increase compared with the typical purely data-driven or knowledge-driven diagnosis approaches. Meanwhile, the diagnostic accuracy reaches 83.98% even when utilizing only 10% of the original training set for the capsule network training and it increases steadily with the increasing proportion, which validates the strong stability and reliability of the proposed approach.
- 24 January 2022
- Published by Taylor & Francis in IETE Journal of Research
- p. 1-8
Credibility-Based Fault Fusion Diagnosis Method for Power Transformer
The fault causes and phenomena of power transformers are complex; different monitoring parameters can reflect its state from different dimensions. In view of the diversity of monitoring data and the characteristics that the acquisition time of different monitoring data is not completely simultaneous, the power transformer fault fusion diagnosis method is proposed based on credibility theory in this paper. First, the monitoring data, including dissolved gas analysis data, partial discharge pulse signal, ultrasonic signal and vibration signal, are diagnosed, respectively. Then the credibility method is used to fuse the single diagnosis results to obtain the comprehensive state of transformers. The case analysis shows that the proposed method can not only make full use of various monitoring data to enhance the accuracy of transformer fault diagnosis but also apply to the fault diagnosis of transformers with different monitoring data types. This provides a new idea for the fusion diagnosis of power transformers.
- 24 January 2022
- Published by Taylor & Francis in IETE Journal of Research
- p. 1-8
Credibility-Based Fault Fusion Diagnosis Method for Power Transformer
The fault causes and phenomena of power transformers are complex; different monitoring parameters can reflect its state from different dimensions. In view of the diversity of monitoring data and the characteristics that the acquisition time of different monitoring data is not completely simultaneous, the power transformer fault fusion diagnosis method is proposed based on credibility theory in this paper. First, the monitoring data, including dissolved gas analysis data, partial discharge pulse signal, ultrasonic signal and vibration signal, are diagnosed, respectively. Then the credibility method is used to fuse the single diagnosis results to obtain the comprehensive state of transformers. The case analysis shows that the proposed method can not only make full use of various monitoring data to enhance the accuracy of transformer fault diagnosis but also apply to the fault diagnosis of transformers with different monitoring data types. This provides a new idea for the fusion diagnosis of power transformers.
- Open Access
- 22 September 2020
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 14 (13) , 2526-2537
Dynamic economic emission dispatch with wind power based on improved multi‐objective brain storm optimisation algorithm
Based on the non‐parametric kernel density estimation technique, the probability distribution of wind power output and its forecast error are accurately modelled. The confidence interval and forecast error upper and lower bounds of wind power output are estimated to build a dynamic economic emission dispatch (DEED) model with wind power penetration. To effectively solve the DEED problem with multi‐objective, high‐dimensional, non‐linear and strong constraints, based on the basic brainstorm optimisation (BSO) algorithm, three improvement mechanisms, namely random clustering centre, differential mutation operation and individual crossover operation are introduced to enhance the converging and diverging operation of BSO. Based on these improvements and external archive mechanism, an improved multi‐objective BSO (IMOBSO) algorithm is proposed. Simulations on a classical test system with ten thermal units are performed, where two case studies are investigated carefully. The simulation results demonstrate that: (i) the proposed IMOBSO can optimise the cost and emission objectives simultaneously and have achieved better performance than other algorithms; (ii) the proposed DEED incorporating wind power model is reasonable and effective because it can achieve the optimal wind power output scheduling by adjusting the system's spinning reserve capacity and the confidence level of wind power prediction interval.
- 22 September 2020
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 14 (13) , 2526-2537
Open AccessDynamic economic emission dispatch with wind power based on improved multi‐objective brain storm optimisation algorithm
Based on the non‐parametric kernel density estimation technique, the probability distribution of wind power output and its forecast error are accurately modelled. The confidence interval and forecast error upper and lower bounds of wind power output are estimated to build a dynamic economic emission dispatch (DEED) model with wind power penetration. To effectively solve the DEED problem with multi‐objective, high‐dimensional, non‐linear and strong constraints, based on the basic brainstorm optimisation (BSO) algorithm, three improvement mechanisms, namely random clustering centre, differential mutation operation and individual crossover operation are introduced to enhance the converging and diverging operation of BSO. Based on these improvements and external archive mechanism, an improved multi‐objective BSO (IMOBSO) algorithm is proposed. Simulations on a classical test system with ten thermal units are performed, where two case studies are investigated carefully. The simulation results demonstrate that: (i) the proposed IMOBSO can optimise the cost and emission objectives simultaneously and have achieved better performance than other algorithms; (ii) the proposed DEED incorporating wind power model is reasonable and effective because it can achieve the optimal wind power output scheduling by adjusting the system's spinning reserve capacity and the confidence level of wind power prediction interval.
- Open Access
- 17 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 151296-151306
Pattern Recognition of Partial Discharge Based on VMD-CWD Spectrum and Optimized CNN With Cross-Layer Feature Fusion
In order to improve the recognition accuracy of partial discharge (PD) by making full use of the time-frequency characteristics of PD signals and employing deep learning theory, a kind of PD pattern recognition method based on variational mode decompositon (VMD)-Choi-Williams distribution (CWD) spectrum and optimized convolutional neural network (CNN) with cross-layer feature fusion is proposed in this paper. Firstly, a PD signal is decomposed into several components by VMD algorithm, and the CWD analysis of the obtained components is carried out to obtain the VMD-CWD time-frequency spectrum. Secondly, the cross-layer feature fusion and optimization CNN (CFFO-CNN) is constructed by introducing cross-layer connection and optimization algorithm. Thirdly, the VMD-CWD is regarded as the input vector to train CFFO-CNN to learn and extract the intrinsic features of the spectrum. Finally, the trained network is used to recognize the PD types of the test samples. The proposed method is compared with traditional recognition methods such as BP neural network (BPNN) and support vector machine (SVM), as well as some commonly used deep learning algorithms. The experimental results indicate that the recognition performance of the proposed method is significantly better than that of existing recognition methods with accuracy up to 99.5%. It is proved that CFFO-CNN has superior feature extraction ability, which can extract the internal features of the VMD-CWD spectrum independently with higher recognition accuracy and wider application prospect.
- 17 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 151296-151306
Open AccessPattern Recognition of Partial Discharge Based on VMD-CWD Spectrum and Optimized CNN With Cross-Layer Feature Fusion
In order to improve the recognition accuracy of partial discharge (PD) by making full use of the time-frequency characteristics of PD signals and employing deep learning theory, a kind of PD pattern recognition method based on variational mode decompositon (VMD)-Choi-Williams distribution (CWD) spectrum and optimized convolutional neural network (CNN) with cross-layer feature fusion is proposed in this paper. Firstly, a PD signal is decomposed into several components by VMD algorithm, and the CWD analysis of the obtained components is carried out to obtain the VMD-CWD time-frequency spectrum. Secondly, the cross-layer feature fusion and optimization CNN (CFFO-CNN) is constructed by introducing cross-layer connection and optimization algorithm. Thirdly, the VMD-CWD is regarded as the input vector to train CFFO-CNN to learn and extract the intrinsic features of the spectrum. Finally, the trained network is used to recognize the PD types of the test samples. The proposed method is compared with traditional recognition methods such as BP neural network (BPNN) and support vector machine (SVM), as well as some commonly used deep learning algorithms. The experimental results indicate that the recognition performance of the proposed method is significantly better than that of existing recognition methods with accuracy up to 99.5%. It is proved that CFFO-CNN has superior feature extraction ability, which can extract the internal features of the VMD-CWD spectrum independently with higher recognition accuracy and wider application prospect.
- Open Access
- 10 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 152081-152092
Improved Binary Artificial Fish Swarm Algorithm and Fast Constraint Processing for Large Scale Unit Commitment
As the power systems in some large developing and developed countries are getting bigger, solving large-scale unit commitment (UC) is an urgent need and significant task to ensure their economic operation and contribute green energy consummation to society. In this article optimization models covering economy and environmental protection are established, and an improved binary artificial fish swarm algorithm (IBAFSA) is presented to solve the large-scale UC problems. The parameters of IBAFSA are improved by Lévy flight and adaptive average visual distance to search space more actively, and a double threshold selection strategy is used to enhance the effectiveness of population evolution in the optimization. Meanwhile, a heuristic greedy search algorithm among the best individuals of all generations in the iterative process of the optimization is proposed, which is beneficial to improve computation convergence and reach the optimum solution. A fast constraints processing mechanism based on the heuristic modifying strategy of unit violation is established to handle the coupling between system spinning reserve constraint and unit minimum up and down time constraint. The effectiveness of the proposed approach is verified by the UC simulations of test systems of 10-1000 units, the IEEE 118-bus system, and a large-scale power system of 270 units. The numerical simulating results show that the proposed UC solution method can achieve the near-optimal solutions in a reasonable time, improve the economic and environmental benefits of a large-scale power system, and is a general method to adapt to the changes of the objective function and constraints of a UC optimization.
- 10 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 152081-152092
Open AccessImproved Binary Artificial Fish Swarm Algorithm and Fast Constraint Processing for Large Scale Unit Commitment
As the power systems in some large developing and developed countries are getting bigger, solving large-scale unit commitment (UC) is an urgent need and significant task to ensure their economic operation and contribute green energy consummation to society. In this article optimization models covering economy and environmental protection are established, and an improved binary artificial fish swarm algorithm (IBAFSA) is presented to solve the large-scale UC problems. The parameters of IBAFSA are improved by Lévy flight and adaptive average visual distance to search space more actively, and a double threshold selection strategy is used to enhance the effectiveness of population evolution in the optimization. Meanwhile, a heuristic greedy search algorithm among the best individuals of all generations in the iterative process of the optimization is proposed, which is beneficial to improve computation convergence and reach the optimum solution. A fast constraints processing mechanism based on the heuristic modifying strategy of unit violation is established to handle the coupling between system spinning reserve constraint and unit minimum up and down time constraint. The effectiveness of the proposed approach is verified by the UC simulations of test systems of 10-1000 units, the IEEE 118-bus system, and a large-scale power system of 270 units. The numerical simulating results show that the proposed UC solution method can achieve the near-optimal solutions in a reasonable time, improve the economic and environmental benefits of a large-scale power system, and is a general method to adapt to the changes of the objective function and constraints of a UC optimization.
- 15 March 2020
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 48 (4-5) , 333-352
Dynamic Economic Dispatch with Wind Power Penetration Based on Non-Parametric Kernel Density Estimation
In order to analyze the randomness of wind power in dynamic economic dispatch (DED) with wind power, based on non-parametric kernel density estimation (KDE) technology, the probability distribution of wind power output and wind power forecast error is accurately modeled. A segmented statistical method on wind power forecast data is adopted to construct the confidence interval of the wind power output, the upper and lower bounds of the forecast errors. According to the established wind power output probability model, forecast confidence interval and forecast error upper and lower bounds, a DED model with wind power is formulated in this paper. A hybrid algorithm combining the evolutionary advantages of bat algorithm (BA) and particle swarm optimization (PSO) algorithm is designed to solve the proposed model. A crossover mechanism, which can solve the problem of falling into local optimum easily existed in BA and PSO, is introduced in the evolution of the algorithm. Finally, the effectiveness of the proposed model and algorithm is verified by simulation examples.
- 15 March 2020
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 48 (4-5) , 333-352
Dynamic Economic Dispatch with Wind Power Penetration Based on Non-Parametric Kernel Density Estimation
In order to analyze the randomness of wind power in dynamic economic dispatch (DED) with wind power, based on non-parametric kernel density estimation (KDE) technology, the probability distribution of wind power output and wind power forecast error is accurately modeled. A segmented statistical method on wind power forecast data is adopted to construct the confidence interval of the wind power output, the upper and lower bounds of the forecast errors. According to the established wind power output probability model, forecast confidence interval and forecast error upper and lower bounds, a DED model with wind power is formulated in this paper. A hybrid algorithm combining the evolutionary advantages of bat algorithm (BA) and particle swarm optimization (PSO) algorithm is designed to solve the proposed model. A crossover mechanism, which can solve the problem of falling into local optimum easily existed in BA and PSO, is introduced in the evolution of the algorithm. Finally, the effectiveness of the proposed model and algorithm is verified by simulation examples.
- 4 November 2019
- Published by Springer Nature in Journal of Control, Automation and Electrical Systems
- Vol. 31 (2) , 511-520
Memetic Algorithm for Solving Monthly Unit Commitment Problem Considering Uncertain Wind Power
- 4 November 2019
- Published by Springer Nature in Journal of Control, Automation and Electrical Systems
- Vol. 31 (2) , 511-520
Memetic Algorithm for Solving Monthly Unit Commitment Problem Considering Uncertain Wind Power
- 12 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 35 (2) , 975-985
Adversarial Feature Learning of Online Monitoring Data for Operational Risk Assessment in Distribution Networks
With the deployment of online monitoring systems in distribution networks, massive amounts of data collected through them contain rich information on the operating states of the networks. By leveraging the data, an unsupervised approach based on bidirectional generative adversarial networks (BiGANs) is proposed for operational risk assessment in distribution networks in this paper. The approach includes two stages: (1) adversarial feature learning. The most representative features are extracted from the online monitoring data and a statistical index $\mathcal {N}_{\phi }$ is calculated for the features, during which we make no assumptions or simplifications on the real data; (2) operational risk assessment. The confidence level $1-\alpha$ for the population mean of the standardized $\mathcal {N}_{\phi }$ is combined with the operational risk levels which are divided into emergency, high risk, preventive, and normal, and the p value for each data point is calculated and compared with the pre-defined interval of $\frac{\alpha }{2}$ to determine the risk levels. The proposed approach is capable of discovering the latent structure of the real data and providing more accurate assessment result. The synthetic data is employed to illustrate the selection of parameters involved in the proposed approach. Case studies on the real-world online monitoring data validate the effectiveness and advantages of the proposed approach in risk assessment.
- 12 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 35 (2) , 975-985
Adversarial Feature Learning of Online Monitoring Data for Operational Risk Assessment in Distribution Networks
With the deployment of online monitoring systems in distribution networks, massive amounts of data collected through them contain rich information on the operating states of the networks. By leveraging the data, an unsupervised approach based on bidirectional generative adversarial networks (BiGANs) is proposed for operational risk assessment in distribution networks in this paper. The approach includes two stages: (1) adversarial feature learning. The most representative features are extracted from the online monitoring data and a statistical index $\mathcal {N}_{\phi }$ is calculated for the features, during which we make no assumptions or simplifications on the real data; (2) operational risk assessment. The confidence level $1-\alpha$ for the population mean of the standardized $\mathcal {N}_{\phi }$ is combined with the operational risk levels which are divided into emergency, high risk, preventive, and normal, and the p value for each data point is calculated and compared with the pre-defined interval of $\frac{\alpha }{2}$ to determine the risk levels. The proposed approach is capable of discovering the latent structure of the real data and providing more accurate assessment result. The synthetic data is employed to illustrate the selection of parameters involved in the proposed approach. Case studies on the real-world online monitoring data validate the effectiveness and advantages of the proposed approach in risk assessment.