Kiran V. Raj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kiran V. Raj has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Jayaraj Joseph
Department of Electrical Engineering, Indian Institute of Technology Madras
6 shared publications Mohanasankar Sivaprakasam
Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India; Healthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India
5 shared publications- P. M. Nabeel
Department of Electrical Engineering, IIT Madras, Chennai, India
5 shared publications Jayaraj Joseph
Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India
3 shared publications- Mohanasankar Sivaprakasam
Indian Institute of Technology Madras
2 shared publications P. M. Nabeel
Healthcare Technology Innovation Centre, IIT Madras, Chennai, India
2 shared publications
Latest Publications
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Measurement of Brachial Local Pulse Wave Velocity for Noninvasive Assessment of Endothelial Reactivity
Endothelial reactivity (ER) is a critical marker of vascular health and a predictor of cardiovascular risk. While ultrasound-based diameter measurements during flow-mediated dilation (FMD) remains the clinical standard for assessing ER, its limitations, including rater dependency and measurement variability, necessitate alternative approaches. In this study, we propose a novel sensor-based measurement methodology, that leverages local pulse wave velocity (PWV) at the brachial artery for endothelial reactivity assessment (ERA). Beat-to-beat local brachial PWV was measured using dual piezoelectric transducers (PWVP) through pulse signal processing and foot detection algorithm. The processed signal then underwent time-series analysis during the reactive hyperemia (RH) procedure for ERA. The approach was validated through two studies: (1) a repeatability and measurement validation study (n = 10), comparing baseline PWVP to ultrasound-derived PWV (PWVU), and (2) an intervention study (n = 40) evaluating the correlation between ERA and FMD during reactive hyperemia. PWVP showed strong agreement with PWVU (R² = 0.89, p < 0.0001), and higher intra-rater measurement repeatability (ICC = 0.91 vs. 0.87). Baseline PWVP exhibited a significant negative correlation with arterial diameter (R² = 0.71) and was higher in females (18.37%). ERA measured via PWVP was consistent across sessions (ICC > 0.85) and showed strong correlation with FMD (R² = 0.88). Notably, mean absolute ERA (34.62%) was higher than FMD (8.64%). These results demonstrate that local PWVP offers a robust and non-invasive approach to assess ER, serving as a practical alternative to ultrasound-based methods, with improved repeatability and strong physiological relevance. This methodology holds promise for scalable vascular health monitoring in clinical and research settings.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Measurement of Brachial Local Pulse Wave Velocity for Noninvasive Assessment of Endothelial Reactivity
Endothelial reactivity (ER) is a critical marker of vascular health and a predictor of cardiovascular risk. While ultrasound-based diameter measurements during flow-mediated dilation (FMD) remains the clinical standard for assessing ER, its limitations, including rater dependency and measurement variability, necessitate alternative approaches. In this study, we propose a novel sensor-based measurement methodology, that leverages local pulse wave velocity (PWV) at the brachial artery for endothelial reactivity assessment (ERA). Beat-to-beat local brachial PWV was measured using dual piezoelectric transducers (PWVP) through pulse signal processing and foot detection algorithm. The processed signal then underwent time-series analysis during the reactive hyperemia (RH) procedure for ERA. The approach was validated through two studies: (1) a repeatability and measurement validation study (n = 10), comparing baseline PWVP to ultrasound-derived PWV (PWVU), and (2) an intervention study (n = 40) evaluating the correlation between ERA and FMD during reactive hyperemia. PWVP showed strong agreement with PWVU (R² = 0.89, p < 0.0001), and higher intra-rater measurement repeatability (ICC = 0.91 vs. 0.87). Baseline PWVP exhibited a significant negative correlation with arterial diameter (R² = 0.71) and was higher in females (18.37%). ERA measured via PWVP was consistent across sessions (ICC > 0.85) and showed strong correlation with FMD (R² = 0.88). Notably, mean absolute ERA (34.62%) was higher than FMD (8.64%). These results demonstrate that local PWVP offers a robust and non-invasive approach to assess ER, serving as a practical alternative to ultrasound-based methods, with improved repeatability and strong physiological relevance. This methodology holds promise for scalable vascular health monitoring in clinical and research settings.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (5) , 1625-1635
Carotid Pressure Wave Separation Analysis Using Multi-Rayleigh Flow Model
Background: Wave separation analysis (WSA) performed at the common carotid artery (CCA) reveals insights into cerebral vascular pathophysiology; however, the conventional WSA (WSAREF) necessitates the availability of both pressure and flow waveforms measured from the same arterial site. Objective: We propose a method for performing WSA at CCA using a single pulse waveform (WSAm-RAY), by modelling the shape of the CCA flow using multi-Rayleigh curves. The WSAm-RAY reduces the measurement complexity, by modelling the flow waveform shape, targeted at scenarios with limited resources, where comprehensive equipment, specialized personnel and hospital settings are often lacking. The modelled flow was compared with the measured flow for accuracy in modelling the flow morphology. The performance of WSAm-RAY was evaluated by comparing the reflection quantification indices derived from WSAREF and WSAm-RAY. Methods: WSAm-RAY employs weighted and shifted multi-Rayleigh functions, time-optimized for characteristic flow peaks in the early and late systolic phase of the CCA flow waveform. The reliability of the modelled flow and performance of WSAm-RAY were validated on 70 (28 female) participants (age: 20 to 51 years). Continuous recording of CCA flow velocity and diameter waveforms were recorded from the participants. Results: The root-mean-squared-error in forward and backward pressure waves was 2.18 ± 0.97 mmHg (∼ 2.5% of the average mean arterial pressure of the study participants). A statistically significant and strong correlation (r > 0.76, p < 0.001) was observed among reflection quantification indices from WSAREF and WSAm-RAY. Conclusion: WSAm-RAY potentially expands the scope of vascular screenings using a single pulse measurement targeting resource constrained settings.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (5) , 1625-1635
Carotid Pressure Wave Separation Analysis Using Multi-Rayleigh Flow Model
Background: Wave separation analysis (WSA) performed at the common carotid artery (CCA) reveals insights into cerebral vascular pathophysiology; however, the conventional WSA (WSAREF) necessitates the availability of both pressure and flow waveforms measured from the same arterial site. Objective: We propose a method for performing WSA at CCA using a single pulse waveform (WSAm-RAY), by modelling the shape of the CCA flow using multi-Rayleigh curves. The WSAm-RAY reduces the measurement complexity, by modelling the flow waveform shape, targeted at scenarios with limited resources, where comprehensive equipment, specialized personnel and hospital settings are often lacking. The modelled flow was compared with the measured flow for accuracy in modelling the flow morphology. The performance of WSAm-RAY was evaluated by comparing the reflection quantification indices derived from WSAREF and WSAm-RAY. Methods: WSAm-RAY employs weighted and shifted multi-Rayleigh functions, time-optimized for characteristic flow peaks in the early and late systolic phase of the CCA flow waveform. The reliability of the modelled flow and performance of WSAm-RAY were validated on 70 (28 female) participants (age: 20 to 51 years). Continuous recording of CCA flow velocity and diameter waveforms were recorded from the participants. Results: The root-mean-squared-error in forward and backward pressure waves was 2.18 ± 0.97 mmHg (∼ 2.5% of the average mean arterial pressure of the study participants). A statistically significant and strong correlation (r > 0.76, p < 0.001) was observed among reflection quantification indices from WSAREF and WSAm-RAY. Conclusion: WSAm-RAY potentially expands the scope of vascular screenings using a single pulse measurement targeting resource constrained settings.
- 18 August 2022
- Published by Elsevier in Ultrasonics
- Vol. 126, 106828
Time-warping for robust automated arterial wall-recognition and tracking from single-scan-line ultrasound signals
- 18 August 2022
- Published by Elsevier in Ultrasonics
- Vol. 126, 106828
Time-warping for robust automated arterial wall-recognition and tracking from single-scan-line ultrasound signals
- 31 May 2022
- Published by IOP Publishing in Physiological Measurement
- Vol. 43 (5) , 055005
Arterial pressure pulse wave separation analysis using a multi-Gaussian decomposition model
Objective. Methods for separating the forward–backward components from blood pulse waves rely on simultaneously measured pressure and flow velocity from a target artery site. Modelling approaches for flow velocity simplify the wave separation analysis (WSA), providing a methodological and instrumentational advantage over the former; however, current methods are limited to the aortic site. In this work, a multi-Gaussian decomposition (MGD) modelled WSA (MGD WSA ) is developed for a non-aortic site such as the carotid artery. While the model is an adaptation of the existing wave separation theory, it does not rely on the information of measured or modelled flow velocity. Approach. The proposed model decomposes the arterial pressure waveform using weighted and shifted multi-Gaussians, which are then uniquely combined to yield the forward ( P F ( t )) and backward ( P B ( t )) pressure wave. A study using the database of healthy (virtual) subjects was used to evaluate the performance of MGD WSA at the carotid artery and was compared against reference flow-based WSA methods. Main results. The MGD modelled pressure waveform yielded a root-mean-square error (RMSE) < 0.35 mmHg. Reliable forward–backward components with a group average RMSE 0.96, p < 0.0001) and ( r > 0.83, p < 0.0001) respectively, with an insignificant ( p > 0.05) bias. Significance. This study reports WSA for carotid pressure waveforms without assumptions on flow conditions. The proposed method has the potential to adapt and widen the vascular health assessment techniques incorporating pulse wave dynamics.
- 31 May 2022
- Published by IOP Publishing in Physiological Measurement
- Vol. 43 (5) , 055005
Arterial pressure pulse wave separation analysis using a multi-Gaussian decomposition model
Objective. Methods for separating the forward–backward components from blood pulse waves rely on simultaneously measured pressure and flow velocity from a target artery site. Modelling approaches for flow velocity simplify the wave separation analysis (WSA), providing a methodological and instrumentational advantage over the former; however, current methods are limited to the aortic site. In this work, a multi-Gaussian decomposition (MGD) modelled WSA (MGD WSA ) is developed for a non-aortic site such as the carotid artery. While the model is an adaptation of the existing wave separation theory, it does not rely on the information of measured or modelled flow velocity. Approach. The proposed model decomposes the arterial pressure waveform using weighted and shifted multi-Gaussians, which are then uniquely combined to yield the forward ( P F ( t )) and backward ( P B ( t )) pressure wave. A study using the database of healthy (virtual) subjects was used to evaluate the performance of MGD WSA at the carotid artery and was compared against reference flow-based WSA methods. Main results. The MGD modelled pressure waveform yielded a root-mean-square error (RMSE) < 0.35 mmHg. Reliable forward–backward components with a group average RMSE 0.96, p < 0.0001) and ( r > 0.83, p < 0.0001) respectively, with an insignificant ( p > 0.05) bias. Significance. This study reports WSA for carotid pressure waveforms without assumptions on flow conditions. The proposed method has the potential to adapt and widen the vascular health assessment techniques incorporating pulse wave dynamics.
- 3 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (7) , 2248-2256
Image-Free Fast Ultrasound for Measurement of Local Pulse Wave Velocity: In Vitro Validation and In Vivo Feasibility
Local pulse wave velocity (PWV), a metric of the target artery’s stiffness, has been emerging in its clinical value and adoption. State-of-the-art ultrasound technologies used to evaluate local PWV based on pulse waves’ features are sophisticated, non-real-time, and are not amenable for field and resource-constrained settings. In this work, we present an image-free ultrasound system to measure local PWV in real-time by employing a pair of ultrasound transducer elements. An in vitro study was performed on the arterial phantom to (i) characterize the design aspects of the system and (ii) validate its accuracy against beat-by-beat (invasive) local PWV measured by a reference dual-element catheter. Further, a repeatability and reproducibility study on 33 subjects (21-52 years) investigated the in vivo measurement feasibility from the carotid artery. With the experimentally deduced optimal design (frame-rate = 500 Hz, RF sampling rate = 125 MHz, LPF cutoff = 14 Hz, and order = 4), the system yielded repeatable beat-to-beat measurements (variability = 1.9%, over 15 cycles) and achieved a high accuracy (root-mean-square-error = 0.19 m/s, absolute-percentage-error = 2.4%) over a wide range of PWVs (2.7 m/s – 11.4 m/s) from the phantom. Subsequently, on human subjects, the intra- and inter-operator PWV measurements were highly repeatable (intraclass correlation coefficient > 0.92). The system does not impose a demand for special processors with high computational power while offering real-time feedback on acquisition and measurement quality and provides local PWV online. Future large population and animal studies are required to establish the device’s clinical usability.
- 3 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (7) , 2248-2256
Image-Free Fast Ultrasound for Measurement of Local Pulse Wave Velocity: In Vitro Validation and In Vivo Feasibility
Local pulse wave velocity (PWV), a metric of the target artery’s stiffness, has been emerging in its clinical value and adoption. State-of-the-art ultrasound technologies used to evaluate local PWV based on pulse waves’ features are sophisticated, non-real-time, and are not amenable for field and resource-constrained settings. In this work, we present an image-free ultrasound system to measure local PWV in real-time by employing a pair of ultrasound transducer elements. An in vitro study was performed on the arterial phantom to (i) characterize the design aspects of the system and (ii) validate its accuracy against beat-by-beat (invasive) local PWV measured by a reference dual-element catheter. Further, a repeatability and reproducibility study on 33 subjects (21-52 years) investigated the in vivo measurement feasibility from the carotid artery. With the experimentally deduced optimal design (frame-rate = 500 Hz, RF sampling rate = 125 MHz, LPF cutoff = 14 Hz, and order = 4), the system yielded repeatable beat-to-beat measurements (variability = 1.9%, over 15 cycles) and achieved a high accuracy (root-mean-square-error = 0.19 m/s, absolute-percentage-error = 2.4%) over a wide range of PWVs (2.7 m/s – 11.4 m/s) from the phantom. Subsequently, on human subjects, the intra- and inter-operator PWV measurements were highly repeatable (intraclass correlation coefficient > 0.92). The system does not impose a demand for special processors with high computational power while offering real-time feedback on acquisition and measurement quality and provides local PWV online. Future large population and animal studies are required to establish the device’s clinical usability.
- Open Access
- 11 January 2022
- Published by Taylor & Francis in Blood Pressure
- Vol. 31 (1) , 19-30
High-frame-rate A-mode ultrasound for calibration-free cuffless carotid pressure: feasibility study using lower body negative pressure intervention
Existing technologies to measure central blood pressure (CBP) intrinsically depend on peripheral pressure or calibration models derived from it. Pharmacological or physiological interventions yield...
- 11 January 2022
- Published by Taylor & Francis in Blood Pressure
- Vol. 31 (1) , 19-30
Open AccessHigh-frame-rate A-mode ultrasound for calibration-free cuffless carotid pressure: feasibility study using lower body negative pressure intervention
Existing technologies to measure central blood pressure (CBP) intrinsically depend on peripheral pressure or calibration models derived from it. Pharmacological or physiological interventions yield...
- 1 October 2020
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 194, 105557
Automated measurement of compression-decompression in arterial diameter and wall thickness by image-free ultrasound
- 1 October 2020
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 194, 105557
Automated measurement of compression-decompression in arterial diameter and wall thickness by image-free ultrasound
- 24 February 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (2) , 025013
ARTSENS®Pen—portable easy-to-use device for carotid stiffness measurement: technology validation and clinical-utility assessment
Objective : The conventional medical imaging modalities used for arterial stiffness measurement are non-scalable and unviable for field-level vascular screening. The need for an affordable, easy-to-operate automated non-invasive technologies remains unmet. To address this need, we present a portable image-free ultrasound device—ARTSENS ® Pen, that uses a single-element ultrasound transducer for carotid stiffness evaluation. Approach: The performance of the device was clinically validated on a cohort of 523 subjects. A clinical-grade B-mode ultrasound imaging system (ALOKA eTracking) was used as the reference. Carotid stiffness measurements were taken using the ARTSENS ® Pen in sitting posture emulating field scenarios. Main results: A statistically significant correlation (r > 0.80, p < 0.0001) with a non-significant bias was observed between the measurements obtained from the two devices. The ARTSENS ® Pen device could perform highly repeatable measurements (with variation smaller than 10%) on a relatively larger percentage of the population when compared to the ALOKA system. The study results also revealed the sensitivity of ARTSENS ® Pen to detect changes in arterial stiffness with age. Significance: The easy-to-use technology and the automated algorithms of the ARTSENS ® Pen make it suitable for cardiovascular risk assessment in resource-constrained settings.
- 24 February 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (2) , 025013
ARTSENS®Pen—portable easy-to-use device for carotid stiffness measurement: technology validation and clinical-utility assessment
Objective : The conventional medical imaging modalities used for arterial stiffness measurement are non-scalable and unviable for field-level vascular screening. The need for an affordable, easy-to-operate automated non-invasive technologies remains unmet. To address this need, we present a portable image-free ultrasound device—ARTSENS ® Pen, that uses a single-element ultrasound transducer for carotid stiffness evaluation. Approach: The performance of the device was clinically validated on a cohort of 523 subjects. A clinical-grade B-mode ultrasound imaging system (ALOKA eTracking) was used as the reference. Carotid stiffness measurements were taken using the ARTSENS ® Pen in sitting posture emulating field scenarios. Main results: A statistically significant correlation (r > 0.80, p < 0.0001) with a non-significant bias was observed between the measurements obtained from the two devices. The ARTSENS ® Pen device could perform highly repeatable measurements (with variation smaller than 10%) on a relatively larger percentage of the population when compared to the ALOKA system. The study results also revealed the sensitivity of ARTSENS ® Pen to detect changes in arterial stiffness with age. Significance: The easy-to-use technology and the automated algorithms of the ARTSENS ® Pen make it suitable for cardiovascular risk assessment in resource-constrained settings.
- 29 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. 13 (19373333) , 74-112
Local Pulse Wave Velocity: Theory, Methods, Advancements, and Clinical Applications
Local pulse wave velocity (PWV) is evolving as one of the important determinants of arterial hemodynamics, localized vessel stiffening associated with several pathologies, and a host of other cardiovascular events. Although PWV was introduced over a century ago, only in recent decades, due to various technological advancements, has emphasis been directed towards its measurement from a single arterial section or from piecewise segments of a target arterial section. This emerging worldwide trend in the exploration of instrumental solutions for local PWV measurement has produced several invasive and non-invasive methods. As of yet, however, a univocal opinion on the ideal measurement method has not emerged. Neither have there been extensive comparative studies on the accuracy of the available methods. Recognizing this reality makes apparent the need to establish guideline-recommended standards for the measurement methods and reference values, without which clinical application cannot be pursued. This work enumerates all major local PWV measurement methods while pinpointing their salient methodological considerations and emphasizing the necessity of global standardization. Further, a summary of the advancements in measuring modalities and clinical applications is provided. Additionally, a detailed discussion on the minimally-explored concept of incremental local PWV is presented along with suggestions of future research questions.
- 29 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. 13 (19373333) , 74-112
Local Pulse Wave Velocity: Theory, Methods, Advancements, and Clinical Applications
Local pulse wave velocity (PWV) is evolving as one of the important determinants of arterial hemodynamics, localized vessel stiffening associated with several pathologies, and a host of other cardiovascular events. Although PWV was introduced over a century ago, only in recent decades, due to various technological advancements, has emphasis been directed towards its measurement from a single arterial section or from piecewise segments of a target arterial section. This emerging worldwide trend in the exploration of instrumental solutions for local PWV measurement has produced several invasive and non-invasive methods. As of yet, however, a univocal opinion on the ideal measurement method has not emerged. Neither have there been extensive comparative studies on the accuracy of the available methods. Recognizing this reality makes apparent the need to establish guideline-recommended standards for the measurement methods and reference values, without which clinical application cannot be pursued. This work enumerates all major local PWV measurement methods while pinpointing their salient methodological considerations and emphasizing the necessity of global standardization. Further, a summary of the advancements in measuring modalities and clinical applications is provided. Additionally, a detailed discussion on the minimally-explored concept of incremental local PWV is presented along with suggestions of future research questions.