Hongbo Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongbo Zhou has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Jianlong Zhao
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
3 shared publications - Chunping Jia
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
2 shared publications - Lei Wu
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
2 shared publications - Anyan Wang
College of Metrology and Measurement Engineering, China Jiliang University, Hangzhou 310018, China
1 shared publication Chengyue Liao
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, CHINA
1 shared publicationChunping Jia
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, CHINA
1 shared publication
Latest Publications
- Open Access
- 29 October 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (11) , 427
A 3D-Printed Microfluidic Device for qPCR Detection of Macrolide-Resistant Mutations of Mycoplasma pneumoniae
Mycoplasma pneumonia (MP) is a common respiratory infection generally treated with macrolides, but resistance mutations against macrolides are often detected in mycoplasma pneumoniae in China. Rapid and accurate identification of mycoplasma pneumoniae and its mutant type is necessary for precise medication. This paper presents a 3D-printed microfluidic device to achieve this. By 3D printing, the stereoscopic structures such as microvalves, reservoirs, drainage tubes, and connectors were fabricated in one step. The device integrated commercial polymerase chain reaction (PCR) tubes as PCR chambers. The detection was a sample-to-answer procedure. First, the sample, a PCR mix, and mineral oil were respectively added to the reservoirs on the device. Next, the device automatically mixed the sample with the PCR mix and evenly dispensed the mixed solution and mineral oil into the PCR chambers, which were preloaded with the specified primers and probes. Subsequently, quantitative real-time PCR (qPCR) was carried out with the homemade instrument. Within 80 min, mycoplasma pneumoniae and its mutation type in the clinical samples were determined, which was verified by DNA sequencing. The easy-to-make and easy-to-use device provides a rapid and integrated detection approach for pathogens and antibiotic resistance mutations, which is urgently needed on the infection scene and in hospital emergency departments.
- 29 October 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (11) , 427
Open AccessA 3D-Printed Microfluidic Device for qPCR Detection of Macrolide-Resistant Mutations of Mycoplasma pneumoniae
Mycoplasma pneumonia (MP) is a common respiratory infection generally treated with macrolides, but resistance mutations against macrolides are often detected in mycoplasma pneumoniae in China. Rapid and accurate identification of mycoplasma pneumoniae and its mutant type is necessary for precise medication. This paper presents a 3D-printed microfluidic device to achieve this. By 3D printing, the stereoscopic structures such as microvalves, reservoirs, drainage tubes, and connectors were fabricated in one step. The device integrated commercial polymerase chain reaction (PCR) tubes as PCR chambers. The detection was a sample-to-answer procedure. First, the sample, a PCR mix, and mineral oil were respectively added to the reservoirs on the device. Next, the device automatically mixed the sample with the PCR mix and evenly dispensed the mixed solution and mineral oil into the PCR chambers, which were preloaded with the specified primers and probes. Subsequently, quantitative real-time PCR (qPCR) was carried out with the homemade instrument. Within 80 min, mycoplasma pneumoniae and its mutation type in the clinical samples were determined, which was verified by DNA sequencing. The easy-to-make and easy-to-use device provides a rapid and integrated detection approach for pathogens and antibiotic resistance mutations, which is urgently needed on the infection scene and in hospital emergency departments.
- 15 February 2020
- Published by Springer Nature in Biomedical Microdevices
- Vol. 22 (1) , 1-10
A centrifugal microfluidic emulsifier integrated with oil storage structures for robust digital LAMP
Centrifugal droplet-based microfluidic devices have been applied to biomedical analysis and diagnostics recently. However, in centrifugal droplet-based microfluidic devices, droplets are tightly packed (i.e., the oil film between neighbouring droplets is thin). Therefore, droplet coalescence usually occurs especially during thermal incubation process. To preserve individual droplets in the devices, we report a new design for monodisperse droplet generation and storage that exploits a centrifugal configuration for droplet emulsification and oil-storage structures (OSSs) for regulation of the thickness of oil film between neighbouring droplets. The centrifugal emulsifier was well designed to ensure uniform droplet generation. Meanwhile, the OSSs could store oil during centrifugal emulsification while release oil before thermal incubation, which “loosen” tightly packed droplets to prevent droplets from coalescing. In this paper, the working process of OSS was analysed, and its shape and size were optimized. Then, the optimized OSSs were integrated into a centrifugal emulsifier for droplet digital loop mediated isothermal amplification (ddLAMP) by which detection of JAK2 V617F mutation within myeloproliferative neoplasms with a dynamic range of 101 to 104 copies per μL was achieved. We anticipate that the simplicity and robustness of our system make it attractive as an inexpensive and easy-to-operate device for DNA amplification, particularly applicable in point-of-care settings.
- 15 February 2020
- Published by Springer Nature in Biomedical Microdevices
- Vol. 22 (1) , 1-10
A centrifugal microfluidic emulsifier integrated with oil storage structures for robust digital LAMP
Centrifugal droplet-based microfluidic devices have been applied to biomedical analysis and diagnostics recently. However, in centrifugal droplet-based microfluidic devices, droplets are tightly packed (i.e., the oil film between neighbouring droplets is thin). Therefore, droplet coalescence usually occurs especially during thermal incubation process. To preserve individual droplets in the devices, we report a new design for monodisperse droplet generation and storage that exploits a centrifugal configuration for droplet emulsification and oil-storage structures (OSSs) for regulation of the thickness of oil film between neighbouring droplets. The centrifugal emulsifier was well designed to ensure uniform droplet generation. Meanwhile, the OSSs could store oil during centrifugal emulsification while release oil before thermal incubation, which “loosen” tightly packed droplets to prevent droplets from coalescing. In this paper, the working process of OSS was analysed, and its shape and size were optimized. Then, the optimized OSSs were integrated into a centrifugal emulsifier for droplet digital loop mediated isothermal amplification (ddLAMP) by which detection of JAK2 V617F mutation within myeloproliferative neoplasms with a dynamic range of 101 to 104 copies per μL was achieved. We anticipate that the simplicity and robustness of our system make it attractive as an inexpensive and easy-to-operate device for DNA amplification, particularly applicable in point-of-care settings.
- Open Access
- 29 April 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (5) , 291
A Facile Strategy for Visualizing and Modulating Droplet-Based Microfluidics
In droplet-based microfluidics, visualizing and modulating of droplets is often prerequisite. In this paper, we report a facile strategy for visualizing and modulating high-throughput droplets in microfluidics. In the strategy, by modulating the sampling frequency of a flash light with the droplet frequency, we are able to map a real high frequency signal to a low frequency signal, which facilitates visualizing and feedback controlling. Meanwhile, because of not needing synchronization signals, the strategy can be directly implemented on any droplet-based microfluidic chips. The only cost of the strategy is an additional signal generator. Moreover, the strategy can catch droplets with frequency up to several kilohertz, which covers the range of most high-throughput droplet-based microfluidics. In this paper, the principle, setup and procedure were introduced. Finally, as a demonstration, the strategy was also implemented in a miniaturized picoinjector in order to monitor and control the injection dosage to droplets. We expect that this facile strategy supplies a low-cost yet effective imaging system that can be easily implemented in miniaturized microfluidic systems or general laboratories.
- 29 April 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (5) , 291
Open AccessA Facile Strategy for Visualizing and Modulating Droplet-Based Microfluidics
In droplet-based microfluidics, visualizing and modulating of droplets is often prerequisite. In this paper, we report a facile strategy for visualizing and modulating high-throughput droplets in microfluidics. In the strategy, by modulating the sampling frequency of a flash light with the droplet frequency, we are able to map a real high frequency signal to a low frequency signal, which facilitates visualizing and feedback controlling. Meanwhile, because of not needing synchronization signals, the strategy can be directly implemented on any droplet-based microfluidic chips. The only cost of the strategy is an additional signal generator. Moreover, the strategy can catch droplets with frequency up to several kilohertz, which covers the range of most high-throughput droplet-based microfluidics. In this paper, the principle, setup and procedure were introduced. Finally, as a demonstration, the strategy was also implemented in a miniaturized picoinjector in order to monitor and control the injection dosage to droplets. We expect that this facile strategy supplies a low-cost yet effective imaging system that can be easily implemented in miniaturized microfluidic systems or general laboratories.
- 22 January 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (6) , 1524-1532
An on-demand nanofluidic concentrator
Preconcentration of biomolecules by electrokinetic trapping at the nano/microfluidic interface has been extensively studied due to its significant efficiency. Conventionally, sample preconcentration takes place in continuous flow and therefore suffers from diffusion and dispersion. Encapsulation of the preconcentrated sample into isolated droplets offers a superior way to preserve the sample concentration for further analysis. Nevertheless, the rationale for an optimal design to obviate the sample dilution prior to encapsulation is still lacking. Herein, we propose a pressure-assisted strategy for positioning the concentrated sample plug directly at the ejecting nozzle, which greatly eliminates the concentration decline during sample ejection. A distinctive mechanism for this plug localization was elucidated by two-dimensional numerical simulations. Based on the simulation results, we developed an on-demand nanofluidic concentrator in which the nanochannels were facilely generated through lithography-free nanocracking on a polystyrene substrate. By wisely implementing an on-demand droplet generation module, our system can adaptively encapsulate the highly concentrated sample and effectively enhance the long-term stability. We experimentally demonstrated the preconcentration of a fluorescently labelled biomolecule, bovine serum albumin (BSA), by using an amplification factor of 104. We showed that, by adjusting the applied voltage, accumulation time, and pulsed pressure imposed on the control microchannel, our system can generate a droplet of the desired volume with a target sample concentration at a prescribed time. This study not only provides insights into the previously unidentified role of assisted pressure in sample positioning, but also offers an avenue for varied requirements in low-abundance biomolecule detection and analysis.
- 22 January 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (6) , 1524-1532
An on-demand nanofluidic concentrator
Preconcentration of biomolecules by electrokinetic trapping at the nano/microfluidic interface has been extensively studied due to its significant efficiency. Conventionally, sample preconcentration takes place in continuous flow and therefore suffers from diffusion and dispersion. Encapsulation of the preconcentrated sample into isolated droplets offers a superior way to preserve the sample concentration for further analysis. Nevertheless, the rationale for an optimal design to obviate the sample dilution prior to encapsulation is still lacking. Herein, we propose a pressure-assisted strategy for positioning the concentrated sample plug directly at the ejecting nozzle, which greatly eliminates the concentration decline during sample ejection. A distinctive mechanism for this plug localization was elucidated by two-dimensional numerical simulations. Based on the simulation results, we developed an on-demand nanofluidic concentrator in which the nanochannels were facilely generated through lithography-free nanocracking on a polystyrene substrate. By wisely implementing an on-demand droplet generation module, our system can adaptively encapsulate the highly concentrated sample and effectively enhance the long-term stability. We experimentally demonstrated the preconcentration of a fluorescently labelled biomolecule, bovine serum albumin (BSA), by using an amplification factor of 104. We showed that, by adjusting the applied voltage, accumulation time, and pulsed pressure imposed on the control microchannel, our system can generate a droplet of the desired volume with a target sample concentration at a prescribed time. This study not only provides insights into the previously unidentified role of assisted pressure in sample positioning, but also offers an avenue for varied requirements in low-abundance biomolecule detection and analysis.