Ian Seymour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ian Seymour has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Alan O'RIordan
Precision Electrochemical Nanosensors Group University College Cork Tyndall National Institute Cork Ireland
11 shared publications Pierre Lovera
Tyndall National Institute, Cork T12 R5CP, Ireland
5 shared publicationsBenjamin O'Sullivan
3 shared publications- James F. Rohan
Tyndall National Institute
3 shared publications James Rohan
3 shared publications- Aidan Murphy
MCCI Microelectronics Circuits Centre Ireland
2 shared publications
Latest Publications
- Open Access
- 23 October 2026
- Published by Elsevier in SSRN Electronic Journal
Exogenous Coreactant-Free Electrochemiluminescence Sensing Platform Using Microfabricated Multiplexed Entwined Spiral Microelectrodes
Luminol electrochemiluminescence (ECL) under physiological conditions is limited by weak emission and often requires exogenous coreactants. Here, we developed a miniaturized silicon platform containing three separate entwined spiral generator-collector (GC) microelectrode-based sensors for coreactant-free ECL sensing. Reactive oxygen species (ROS) were electrochemically generated in situ from dissolved O₂ at the generator electrode and acted as local coreactants for the luminol ECL reaction at the collector electrode. Seven electrode geometries with gaps and widths of 2-20 µm were microfabricated and evaluated using electrochemical redox cycling and ECL measurements. The W2G2 geometry (2 µm width, 2 µm gap) achieved 93% collection efficiency and an 11-fold increase in luminol ECL compared with operation without the generator electrode. ROS-scavenging studies identified the superoxide radical anion (O₂•⁻) as the dominant ROS contributing to GC-enhanced ECL. Trolox and H₂O₂ were used as model chemical analytes to evaluate ROS-dependent signal modulation. For immunosensing, a chitosan nanocomposite hydrogel was selectively electrodeposited on the collector electrodes of the W2G10 design, followed by Protein A/G-mediated oriented immobilization of anti-IgG antibodies and peptide-based antifouling layer. The immunosensor exhibited a linear range of 1 fg mL⁻¹ to 100 pg mL⁻¹ with a detection limit of 0.88 fg mL⁻¹, preserved its analytical performance in 25 % fetal bovine serum, showed good reproducibility within and between independently biofunctionalized chips, good stability and yielded results consistent with ELISA. These results demonstrate the feasibility of integrating coreactant-free GC-ECL amplification and affinity biosensing within a compact multi-sensor platform, supporting its further development toward portable point-of-care applications.
- 23 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExogenous Coreactant-Free Electrochemiluminescence Sensing Platform Using Microfabricated Multiplexed Entwined Spiral Microelectrodes
Luminol electrochemiluminescence (ECL) under physiological conditions is limited by weak emission and often requires exogenous coreactants. Here, we developed a miniaturized silicon platform containing three separate entwined spiral generator-collector (GC) microelectrode-based sensors for coreactant-free ECL sensing. Reactive oxygen species (ROS) were electrochemically generated in situ from dissolved O₂ at the generator electrode and acted as local coreactants for the luminol ECL reaction at the collector electrode. Seven electrode geometries with gaps and widths of 2-20 µm were microfabricated and evaluated using electrochemical redox cycling and ECL measurements. The W2G2 geometry (2 µm width, 2 µm gap) achieved 93% collection efficiency and an 11-fold increase in luminol ECL compared with operation without the generator electrode. ROS-scavenging studies identified the superoxide radical anion (O₂•⁻) as the dominant ROS contributing to GC-enhanced ECL. Trolox and H₂O₂ were used as model chemical analytes to evaluate ROS-dependent signal modulation. For immunosensing, a chitosan nanocomposite hydrogel was selectively electrodeposited on the collector electrodes of the W2G10 design, followed by Protein A/G-mediated oriented immobilization of anti-IgG antibodies and peptide-based antifouling layer. The immunosensor exhibited a linear range of 1 fg mL⁻¹ to 100 pg mL⁻¹ with a detection limit of 0.88 fg mL⁻¹, preserved its analytical performance in 25 % fetal bovine serum, showed good reproducibility within and between independently biofunctionalized chips, good stability and yielded results consistent with ELISA. These results demonstrate the feasibility of integrating coreactant-free GC-ECL amplification and affinity biosensing within a compact multi-sensor platform, supporting its further development toward portable point-of-care applications.
- Open Access
- 23 February 2026
- Published by Elsevier in SSRN Electronic Journal
Gold/Gold Oxide as a Solid State On-Chip pH Sensing Probe for Food Applications
In this work we investigate Gold/gold oxide as a solid-state ultra-micro pH sensor for monitoring of different foods which are, typically between 3.5-7 in pH. Using cyclic voltammetry, a linear shift in the gold oxide reduction peak voltage was observed, in response to changes in pH of a solution in which the sensor is submerged. The sensor also has very low sample volume requirements down to ~100 µL. Sensors gave a super-Nernstian response of -67.7 mV/pH in the pH range of pH 3 to pH 7 with an accuracy of <0.02 of pH units. Their high sensitivity, low hysteresis and minimal effect by common interferents demonstrate that these electrodes can be utilised as pH sensors for real world application. A maximum deviation of 0.29 pH units between the developed metal-oxide pH sensor and a conventional glass electrode indicates good usability for beverage samples.
- 23 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessGold/Gold Oxide as a Solid State On-Chip pH Sensing Probe for Food Applications
In this work we investigate Gold/gold oxide as a solid-state ultra-micro pH sensor for monitoring of different foods which are, typically between 3.5-7 in pH. Using cyclic voltammetry, a linear shift in the gold oxide reduction peak voltage was observed, in response to changes in pH of a solution in which the sensor is submerged. The sensor also has very low sample volume requirements down to ~100 µL. Sensors gave a super-Nernstian response of -67.7 mV/pH in the pH range of pH 3 to pH 7 with an accuracy of <0.02 of pH units. Their high sensitivity, low hysteresis and minimal effect by common interferents demonstrate that these electrodes can be utilised as pH sensors for real world application. A maximum deviation of 0.29 pH units between the developed metal-oxide pH sensor and a conventional glass electrode indicates good usability for beverage samples.
- Open Access
- 8 August 2025
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 1 (10) , 2097-2105
Electrochemical Approach for In Situ pH Control and Monitoring in Hydrodynamic Environments
- 8 August 2025
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 1 (10) , 2097-2105
Open AccessElectrochemical Approach for In Situ pH Control and Monitoring in Hydrodynamic Environments
- Open Access
- 26 March 2021
- Published by American Chemical Society (ACS) in ChemRxiv
Advanced Solid State Nano-electrochemical Sensors and System for Agri 4.0 Applications
Global food production needs to increase in order to meet the demands of an ever growing population. As resources are finite, the most feasible way to meet this demand is to minimize losses and improving efficiency. Regular monitoring of factors like animal health, soil and water quality for example, can ensure that the resources are being used to their maximum efficiency. Existing monitoring techniques however have limitations, such as portability, turnaround time and requirement for additional reagents. In this work, we explore the use of micro and nano scale electrode devices, for the development of electrochemical sensing platform to digitalize a wide range of applications within the Agri-food sector. With this platform, we demonstrate the direct electrochemical detection of pesticides, specifically clothianidin and imidacloprid with detection limits of 0.22 ng/mL and 2.14 ng/mL respectively, and nitrates with a detection limit of 0.2 µM. In addition, interdigitated electrode structures also enable an in-situ pH control technique to mitigate pH as an interference and modify analyte response. This technique is applied to the analysis of monochloramine, a common water disinfectant. Concerning biosensing, the sensors are modified with biomolecular probes for the detection of both bovine viral diarrhea virus particles and antibodies, over a range of 1 ng/mL to 10 µg/mL. Finally, a portable analogue front end electronic reader is developed to allow portable sensing, with control and readout undertaken using a smart phone application. Finally, the sensor chip platform is integrated with these electronics to provide a fully functional end-to-end smart sensor system compatible with emerging AgriFood digital decision support tools.
- 26 March 2021
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessAdvanced Solid State Nano-electrochemical Sensors and System for Agri 4.0 Applications
Global food production needs to increase in order to meet the demands of an ever growing population. As resources are finite, the most feasible way to meet this demand is to minimize losses and improving efficiency. Regular monitoring of factors like animal health, soil and water quality for example, can ensure that the resources are being used to their maximum efficiency. Existing monitoring techniques however have limitations, such as portability, turnaround time and requirement for additional reagents. In this work, we explore the use of micro and nano scale electrode devices, for the development of electrochemical sensing platform to digitalize a wide range of applications within the Agri-food sector. With this platform, we demonstrate the direct electrochemical detection of pesticides, specifically clothianidin and imidacloprid with detection limits of 0.22 ng/mL and 2.14 ng/mL respectively, and nitrates with a detection limit of 0.2 µM. In addition, interdigitated electrode structures also enable an in-situ pH control technique to mitigate pH as an interference and modify analyte response. This technique is applied to the analysis of monochloramine, a common water disinfectant. Concerning biosensing, the sensors are modified with biomolecular probes for the detection of both bovine viral diarrhea virus particles and antibodies, over a range of 1 ng/mL to 10 µg/mL. Finally, a portable analogue front end electronic reader is developed to allow portable sensing, with control and readout undertaken using a smart phone application. Finally, the sensor chip platform is integrated with these electronics to provide a fully functional end-to-end smart sensor system compatible with emerging AgriFood digital decision support tools.
- Open Access
- 22 February 2021
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 6 (3) , 1030-1038
Elimination of Oxygen Interference in the Electrochemical Detection of Monochloramine, Using In Situ pH Control at Interdigitated Electrodes
Disinfection of water systems by chloramination is a method frequently used in North America as an alternative to chlorination. In such a case, monochloramine is used as the primary chlorine source for disinfection. Regular monitoring of the residual concentrations of this species is essential to ensure adequate disinfection. An amperometric sensor for monochloramine would provide fast, reagent-free analysis; however, the presence of dissolved oxygen in water complicates sensor development. In this work, we used in-situ pH control as a method to eliminate oxygen interference by conversion of monochloramine to dichloramine. Unlike monochloramine, the electrochemical reduction of dichloramine occurs outside the oxygen reduction potential window and is therefore not affected by the oxygen concentration. Potential sweep methods were used to investigate the conversion of monochloramine to dichloramine at pH 3. The pH control method was used to calibrate monochloramine concentrations between 1 and 10 ppm, with a detection limit of 0.03 ppm. Tests were carried out in high alkalinity samples, wherein it was found that the sensitivity of this method effectively remained unchanged. Monochloramine was also quantified in the presence of common interferents (copper, phosphate, and iron) which also had no significant impact on the analysis.
- 22 February 2021
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 6 (3) , 1030-1038
Open AccessElimination of Oxygen Interference in the Electrochemical Detection of Monochloramine, Using In Situ pH Control at Interdigitated Electrodes
Disinfection of water systems by chloramination is a method frequently used in North America as an alternative to chlorination. In such a case, monochloramine is used as the primary chlorine source for disinfection. Regular monitoring of the residual concentrations of this species is essential to ensure adequate disinfection. An amperometric sensor for monochloramine would provide fast, reagent-free analysis; however, the presence of dissolved oxygen in water complicates sensor development. In this work, we used in-situ pH control as a method to eliminate oxygen interference by conversion of monochloramine to dichloramine. Unlike monochloramine, the electrochemical reduction of dichloramine occurs outside the oxygen reduction potential window and is therefore not affected by the oxygen concentration. Potential sweep methods were used to investigate the conversion of monochloramine to dichloramine at pH 3. The pH control method was used to calibrate monochloramine concentrations between 1 and 10 ppm, with a detection limit of 0.03 ppm. Tests were carried out in high alkalinity samples, wherein it was found that the sensitivity of this method effectively remained unchanged. Monochloramine was also quantified in the presence of common interferents (copper, phosphate, and iron) which also had no significant impact on the analysis.
- Open Access
- 10 February 2021
- Published by American Chemical Society (ACS) in ChemRxiv
A Theoretical and Experimental Study of Electrochemical pH Control at Gold Interdigitated Microband Arrays
In electroanalysis, solution pH is a critical parameter that often needs to be adjusted and controlled for the detection of particular analytes. This is most commonly performed by the addition of chemicals, such as strong acids or bases. Electrochemical in-situ pH control offers the possibility for the local adjustment of pH at the point of detection, without additional reagents. FEA simulations have been performed to guide experimental design for both electroanalysis and in-situ control of solution pH. No previous model exists that describes the generation of protons at an interdigitated electrode array in buffered solution with one comb acting as a protonator, and the other as the sensor. In this work, FEA models are developed to provide insight into the optimum conditions necessary for electrochemical pH control. The magnitude of applied galvanostatic current has a direct relation to the flux of protons generated and subsequent change in pH. Increasing the separation between the electrodes increases the time taken for protons to diffuse across the gap. The final pH achieved at both, protonators and sensor electrodes, after 1 second, was shown to be largely uninfluenced by the initial pH of the solution. The impact of buffer concentration was modelled and investigated. In practice, the pH at the electrode surface was probed by means of cyclic voltammetry, i.e., by cycling a gold electrode in solution and identifying the potential of the gold oxide reduction peak. A pH indicator, methyl red, was used to visualise the solution pH change at the electrodes, comparing well with the model’s prediction
- 10 February 2021
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessA Theoretical and Experimental Study of Electrochemical pH Control at Gold Interdigitated Microband Arrays
In electroanalysis, solution pH is a critical parameter that often needs to be adjusted and controlled for the detection of particular analytes. This is most commonly performed by the addition of chemicals, such as strong acids or bases. Electrochemical in-situ pH control offers the possibility for the local adjustment of pH at the point of detection, without additional reagents. FEA simulations have been performed to guide experimental design for both electroanalysis and in-situ control of solution pH. No previous model exists that describes the generation of protons at an interdigitated electrode array in buffered solution with one comb acting as a protonator, and the other as the sensor. In this work, FEA models are developed to provide insight into the optimum conditions necessary for electrochemical pH control. The magnitude of applied galvanostatic current has a direct relation to the flux of protons generated and subsequent change in pH. Increasing the separation between the electrodes increases the time taken for protons to diffuse across the gap. The final pH achieved at both, protonators and sensor electrodes, after 1 second, was shown to be largely uninfluenced by the initial pH of the solution. The impact of buffer concentration was modelled and investigated. In practice, the pH at the electrode surface was probed by means of cyclic voltammetry, i.e., by cycling a gold electrode in solution and identifying the potential of the gold oxide reduction peak. A pH indicator, methyl red, was used to visualise the solution pH change at the electrodes, comparing well with the model’s prediction
- Open Access
- 1 December 2020
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 325
Electrochemical detection of free-chlorine in Water samples facilitated by in-situ pH control using interdigitated microelectrodes
- 1 December 2020
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 325
Open AccessElectrochemical detection of free-chlorine in Water samples facilitated by in-situ pH control using interdigitated microelectrodes
- 4 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (1530437X) , 1
Portable Data Acquisition System for Nano and Ultra-Micro Scale Electrochemical Sensors
This work describes a flexible and portable data acquisition system that has been developed to interface to nano and ultra-micro scale electrochemical sensors at the point of use. It can perform a range of voltammetric tests, including Cyclic Voltammetry, Square Wave Voltammetry and Generator Collector Voltammetery. The data acquisition system interfaces to a smartphone, operates from a rechargeable battery and is of suitable form factor to ensure that it's fully portable. By utilising commercially available components, this system has been developed to lower the barrier for entry for the development of emerging portable electrochemical sensing technologies at micro and nano scale. To show the full range of functionality of the system, a use case involving river water quality monitoring is presented through generation of a calibration curve, using a recently developed Tyndall National Institute ultra-microband electrochemical sensor, for the detection of dissolved oxygen in river water.
- 4 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (1530437X) , 1
Portable Data Acquisition System for Nano and Ultra-Micro Scale Electrochemical Sensors
This work describes a flexible and portable data acquisition system that has been developed to interface to nano and ultra-micro scale electrochemical sensors at the point of use. It can perform a range of voltammetric tests, including Cyclic Voltammetry, Square Wave Voltammetry and Generator Collector Voltammetery. The data acquisition system interfaces to a smartphone, operates from a rechargeable battery and is of suitable form factor to ensure that it's fully portable. By utilising commercially available components, this system has been developed to lower the barrier for entry for the development of emerging portable electrochemical sensing technologies at micro and nano scale. To show the full range of functionality of the system, a use case involving river water quality monitoring is presented through generation of a calibration curve, using a recently developed Tyndall National Institute ultra-microband electrochemical sensor, for the detection of dissolved oxygen in river water.
- Open Access
- 31 July 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Elimination of Oxygen Interference in the Electrochemical Detection of Monochloramine, Using In-Situ pH Control at Interdigitated Electrodes
Disinfection by chloramination of water systems is an alternative to chlorination that is frequently used in North America. In such a case, monochloramine is used as the primary source of chlorine for disinfection. Regular monitoring of the residual concentrations of this species is crucial to ensure adequate disinfection. An amperometric sensor for monochloramine would provide fast, reagent free analysis, however the presence of dissolved oxygen in water complicates sensor development. In this work, we have explored the use of in-situ pH control as a method of eliminating oxygen as an interferent by conversion of monochloramine to dichloramine. The electrochemical reduction of dichloramine occurs outside the oxygen reduction window and is therefore not affected by oxygen concentration. Potential sweep methods were used to investigate the conversion of monochloramine to dichloramine at pH 3. The pH control method was used to calibrate monochloramine concentrations between 1 and 10 ppm, with a detection limit of 0.03 ppm. Tests were carried out in high alkalinity samples, wherein it was found that the sensitivity of this method effectively remained unchanged. Monochloramine was also quantified in the presence of common interferents (copper, phosphate and iron) which had no significant impact on the analysis
- 31 July 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessElimination of Oxygen Interference in the Electrochemical Detection of Monochloramine, Using In-Situ pH Control at Interdigitated Electrodes
Disinfection by chloramination of water systems is an alternative to chlorination that is frequently used in North America. In such a case, monochloramine is used as the primary source of chlorine for disinfection. Regular monitoring of the residual concentrations of this species is crucial to ensure adequate disinfection. An amperometric sensor for monochloramine would provide fast, reagent free analysis, however the presence of dissolved oxygen in water complicates sensor development. In this work, we have explored the use of in-situ pH control as a method of eliminating oxygen as an interferent by conversion of monochloramine to dichloramine. The electrochemical reduction of dichloramine occurs outside the oxygen reduction window and is therefore not affected by oxygen concentration. Potential sweep methods were used to investigate the conversion of monochloramine to dichloramine at pH 3. The pH control method was used to calibrate monochloramine concentrations between 1 and 10 ppm, with a detection limit of 0.03 ppm. Tests were carried out in high alkalinity samples, wherein it was found that the sensitivity of this method effectively remained unchanged. Monochloramine was also quantified in the presence of common interferents (copper, phosphate and iron) which had no significant impact on the analysis
- Open Access
- 10 July 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Reagent Free Electrochemical-Based Detection of Silver Ions at Interdigitated Micro Electrodes Using in Situ pH Control
Silver ions, the most toxic form of silver, can be present in drinking water due to their release from silver nanoparticles which are widely used in consumer products. Due to their adverse health effects, a quick portable approach for detection in drinking water is needed. Herein we report on the development of an electrochemical sensor for silver ions detection in tap water using linear sweep voltammetry with in situ pH control; enabled by closely space interdigitated electrode arrays. The in situ pH control approach, allows the pH of a test solution to be tailored to pH 3 thereby eliminating the current need for acid addition. A calibration curve between 0.2 - 10 µM was established for silver detection in sodium acetate when 1.25 V and 1.65 V was applied at the protonator electrode during deposition and stripping, respectively, as a proof of concept study. For the final application in tap water, 1.65 V was applied at the protonator electrode during deposition and stripping. The chlorine ions, present in tap water as a consequence of the disinfection process, facilitated the silver detection and no additional electrolyte had to be added. Combination of complexation of silver ions with chlorine coupled with in situ pH control resulted in linear calibration range between 0.25 and 2 µM in tap water without the need for acidification.
- 10 July 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessReagent Free Electrochemical-Based Detection of Silver Ions at Interdigitated Micro Electrodes Using in Situ pH Control
Silver ions, the most toxic form of silver, can be present in drinking water due to their release from silver nanoparticles which are widely used in consumer products. Due to their adverse health effects, a quick portable approach for detection in drinking water is needed. Herein we report on the development of an electrochemical sensor for silver ions detection in tap water using linear sweep voltammetry with in situ pH control; enabled by closely space interdigitated electrode arrays. The in situ pH control approach, allows the pH of a test solution to be tailored to pH 3 thereby eliminating the current need for acid addition. A calibration curve between 0.2 - 10 µM was established for silver detection in sodium acetate when 1.25 V and 1.65 V was applied at the protonator electrode during deposition and stripping, respectively, as a proof of concept study. For the final application in tap water, 1.65 V was applied at the protonator electrode during deposition and stripping. The chlorine ions, present in tap water as a consequence of the disinfection process, facilitated the silver detection and no additional electrolyte had to be added. Combination of complexation of silver ions with chlorine coupled with in situ pH control resulted in linear calibration range between 0.25 and 2 µM in tap water without the need for acidification.