Wenjun Shao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wenjun Shao has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ji Yi
Johns Hopkins University
2 shared publications - Botir D Ibragimov
Tashkent State Transport University
1 shared publication Guodong Han
WHUT
1 shared publication- Haoyu Zhang
WHUT
1 shared publication Jiangang Wang
1 shared publicationManishi Desai
Department of Ophthalmology, Boston University School of Medicine, Boston Medical Center, Boston, 02118, USA
1 shared publication
Latest Publications
- 12 June 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (27) , 275110
A dual-modal data fusion-driven approach for fatigue life estimation of cracked structures
To address the limitations of low accuracy and poor reliability in traditional fatigue life estimation methods for metal structures with macroscopic fatigue cracks, a dual-modal data fusion approach integrating a finite element model and an LSTM (Long Short-Term Memory) network is proposed. First, a finite element model incorporating boundary conditions and cyclic loading is developed to simulate crack propagation. To enhance the model's accuracy, an improved particle filtering algorithm is employed to optimize high-sensitivity parameters, ensuring that the simulated strain and vibration modal data closely match the measured values, achieving an overall fatigue life fidelity of 97.7% for the calibrated finite element model. Furthermore, an LSTM network is introduced to refine the estimation of strain and vibration data based on the optimized finite element model, achieving an estimation error below 2% in crack length estimation. Experimental validation using a fatigue testing platform demonstrates an estimation error below 2% for fatigue life, surpassing single-modal methods by 4.6%. The results confirm the proposed method's effectiveness in addressing data incompleteness in traditional approaches while significantly improving estimation robustness and reliability.
- 12 June 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (27) , 275110
A dual-modal data fusion-driven approach for fatigue life estimation of cracked structures
To address the limitations of low accuracy and poor reliability in traditional fatigue life estimation methods for metal structures with macroscopic fatigue cracks, a dual-modal data fusion approach integrating a finite element model and an LSTM (Long Short-Term Memory) network is proposed. First, a finite element model incorporating boundary conditions and cyclic loading is developed to simulate crack propagation. To enhance the model's accuracy, an improved particle filtering algorithm is employed to optimize high-sensitivity parameters, ensuring that the simulated strain and vibration modal data closely match the measured values, achieving an overall fatigue life fidelity of 97.7% for the calibrated finite element model. Furthermore, an LSTM network is introduced to refine the estimation of strain and vibration data based on the optimized finite element model, achieving an estimation error below 2% in crack length estimation. Experimental validation using a fatigue testing platform demonstrates an estimation error below 2% for fatigue life, surpassing single-modal methods by 4.6%. The results confirm the proposed method's effectiveness in addressing data incompleteness in traditional approaches while significantly improving estimation robustness and reliability.
- 26 November 2025
- Published by Elsevier in Measurement
- Vol. 260
Oblique illumination line confocal imaging with adjustable aperture for wafer defect detection
- 26 November 2025
- Published by Elsevier in Measurement
- Vol. 260
Oblique illumination line confocal imaging with adjustable aperture for wafer defect detection
- Open Access
Micro-Gap Weld Seam Contrast Enhancement via Phase Contrast Imaging
The precision and stability of seam position detection are critical for single-square-groove weld seams formed using two thin metal plates. However, traditional methods, such as structured laser light imaging, struggle with narrow seams that lack misalignment and have high reflectivity, while non-structured light approaches are prone to welding light interference and speckle noise. To overcome these challenges, we propose a versatile optical design that leverages differential illumination to generate differential phase contrast (DPC) images. By processing images captured under differential illumination, the DPC method notably enhances seam edge contrast and suppresses welding light noise, improving the detection robustness and reliability. This approach provides a promising solution for high-precision weld seam detection in challenging environments.
Open AccessMicro-Gap Weld Seam Contrast Enhancement via Phase Contrast Imaging
The precision and stability of seam position detection are critical for single-square-groove weld seams formed using two thin metal plates. However, traditional methods, such as structured laser light imaging, struggle with narrow seams that lack misalignment and have high reflectivity, while non-structured light approaches are prone to welding light interference and speckle noise. To overcome these challenges, we propose a versatile optical design that leverages differential illumination to generate differential phase contrast (DPC) images. By processing images captured under differential illumination, the DPC method notably enhances seam edge contrast and suppresses welding light noise, improving the detection robustness and reliability. This approach provides a promising solution for high-precision weld seam detection in challenging environments.
- Open Access
Visible light optical coherence tomography angiography (vis-OCTA) and local microvascular retinal oximetry in human retina
We report herein the first visible light optical coherence tomography angiography (vis-OCTA) for human retinal imaging. Compared to the existing vis-OCT systems, we devised a spectrometer with a narrower bandwidth to increase the spectral power density for OCTA imaging, while retaining the major spectral contrast in the blood. We achieved a 100 kHz A-line rate, the fastest acquisition speed reported so far for human retinal vis-OCT. We rigorously optimized the imaging protocol such that a single acquisition takes 2 . The angiography enables accurate localization of microvasculature down to the capillary level and thus enables oximetry at vessels < 100 μm in diameter. We demonstrated microvascular hemoglobin oxygen saturation (sO 2 ) at the feeding and draining vessels at the perifoveal region. The longitudinal repeatability was assessed by <5% coefficient of variation (CV). The unique capabilities of our vis-OCTA system may allow studies on the role of microvascular oxygen in various retinal pathologies.
Open AccessVisible light optical coherence tomography angiography (vis-OCTA) and local microvascular retinal oximetry in human retina
We report herein the first visible light optical coherence tomography angiography (vis-OCTA) for human retinal imaging. Compared to the existing vis-OCT systems, we devised a spectrometer with a narrower bandwidth to increase the spectral power density for OCTA imaging, while retaining the major spectral contrast in the blood. We achieved a 100 kHz A-line rate, the fastest acquisition speed reported so far for human retinal vis-OCT. We rigorously optimized the imaging protocol such that a single acquisition takes 2 . The angiography enables accurate localization of microvasculature down to the capillary level and thus enables oximetry at vessels < 100 μm in diameter. We demonstrated microvascular hemoglobin oxygen saturation (sO 2 ) at the feeding and draining vessels at the perifoveal region. The longitudinal repeatability was assessed by <5% coefficient of variation (CV). The unique capabilities of our vis-OCTA system may allow studies on the role of microvascular oxygen in various retinal pathologies.
- 3 March 2020
- Published by Wiley in Journal of Biophotonics
- Vol. 13 (6) , e201960174
Is oblique scanning laser ophthalmoscope applicable to human ocular optics? A feasibility study using an eye model for volumetric imaging
Oblique scanning laser ophthalmoscopy (oSLO) is a novel imaging modality to provide volumetric retinal imaging without depth sectioning over a large field of view (FOV). It has been successfully demonstrated in vivo in rodent eyes for volumetric fluorescein angiography (vFA). However, engineering oSLO for human retinal imaging is challenging because of the low numerical aperture (NA) of human ocular optics. To overcome this challenge, we implement optical designs to (a) increase the angle of the intermediate image under Scheimpflug condition, and (b) expand the magnification in the depth dimension with cylindrical lens to enable sufficient sampling density. In addition, we adopt a scanning‐and‐descaning strategy, resulting in a compact oSLO system. We experimentally show that the current setup can achieve a FOV of ~3 × 6 × 0.8 mm3, and the transverse and axial resolutions of 7 and 41 μm, respectively. This feasibility study serves an important step for future in vivo human retinal imaging.
- 3 March 2020
- Published by Wiley in Journal of Biophotonics
- Vol. 13 (6) , e201960174
Is oblique scanning laser ophthalmoscope applicable to human ocular optics? A feasibility study using an eye model for volumetric imaging
Oblique scanning laser ophthalmoscopy (oSLO) is a novel imaging modality to provide volumetric retinal imaging without depth sectioning over a large field of view (FOV). It has been successfully demonstrated in vivo in rodent eyes for volumetric fluorescein angiography (vFA). However, engineering oSLO for human retinal imaging is challenging because of the low numerical aperture (NA) of human ocular optics. To overcome this challenge, we implement optical designs to (a) increase the angle of the intermediate image under Scheimpflug condition, and (b) expand the magnification in the depth dimension with cylindrical lens to enable sufficient sampling density. In addition, we adopt a scanning‐and‐descaning strategy, resulting in a compact oSLO system. We experimentally show that the current setup can achieve a FOV of ~3 × 6 × 0.8 mm3, and the transverse and axial resolutions of 7 and 41 μm, respectively. This feasibility study serves an important step for future in vivo human retinal imaging.