MTMitsuo Tokuhara

Mitsuo Tokuhara

*This is an algorithmically generated author record based on publicly available information.

Mitsuo Tokuhara has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Masaaki Shimatani

    Division of Gastroenterology and Hepatology Kansai Medical University Medical Center Osaka Japan

    3 shared publications
  • Hiroko Nakahira

    Department of Gastrointestinal Oncology Osaka International Cancer Institute Osaka Japan

    2 shared publications
  • Kazuichi Okazaki

    Kansai Medical University Kori Hospital Osaka Japan

    2 shared publications
  • Makoto Takaoka

    Division of Gastroenterology and Hepatology The Third Department of Internal Medicine Kansai Medical University OsakaJapan

    2 shared publications
  • Masataka Masuda

    Division of Gastroenterology and Hepatology The Third Department of Internal Medicine Kansai Medical University OsakaJapan

    2 shared publications
  • Sachi Miyamoto

    Division of Gastroenterology and Hepatology The Third Department of Internal Medicine Kansai Medical University OsakaJapan

    2 shared publications

Latest Publications

  • Open Access

    Depth of noninjecting resection using bipolar soft coagulation mode for 6 to 9 mm colorectal polyps: a retrospective study in Japan

    by Yoshifumi Watanabe, Mitsuo Tokuhara, Hidetoshi Nakata, Hiroko Nakahira, Ikuko Torii, Yasumasa Sumitomo

    Background/Aims: Endoscopic resection of colorectal polyps reduces mortality from colorectal cancer. We report here a novel resection method, known as noninjecting resection using bipolar soft coagulation mode (NIRBS), and assess its feasibility. This study aimed to compare the resection depth achieved with NIRBS to those achieved with cold snare polypectomy (CSP) and conventional endoscopic mucosal resection (CEMR).Methods: Patients with 6 to 9 mm colorectal polyps underwent endoscopic resection at Hoshigaoka Medical Center between October 2023 and January 2024. We analyzed the thickness of resected submucosal tissue following the use of NIRBS, CSP, and CEMR.Results: We identified 95 polyps, including adenomas and serrated lesions. The proportions of specimens containing submucosal tissue were 21.4%, 100.0%, and 97.9% in CSP, CEMR, and NIRBS, respectively. The median submucosal tissue thickness for CEMR and NIRBS was 1,167 and 1,125 µm, respectively, which was significantly greater than 0 µm for CSP. For NIRBS, the median thickness was 1,140 and 1,017 µm for the expert and non-expert endoscopists, respectively.Conclusions: The depth of submucosal resection with NIRBS exceeded 1,000 μm regardless of endoscopist experience. NIRBS can be a useful resection method for patients with colorectal polyps, including those with non-submucosally invasive carcinomas.


  • Open Access

    Evaluation of a new method, “non-injection resection using bipolar soft coagulation mode (NIRBS)”, for colonic adenomatous lesions

    by Mitsuo Tokuhara, Masaaki Shimatani, Kazunari Tominaga, Hiroko Nakahira, Takuya Ohtsu, Katsuyasu Kouda, Makoto Naganuma

    Background/Aims: Endoscopic resection of all colorectal adenomatous lesions with a low complication rate, simplicity, and negative residuals is challenging. Hence, we developed a new method called “non-injection resection using bipolar soft coagulation mode (NIRBS)” method, adapted for colorectal lesions. In addition, we evaluated the effectiveness of this method.Methods: We performed NIRBS throughout a 12-month period for all colorectal lesions which snare resection was acceptable without cancerous lesions infiltrating deeper than the submucosal layer.Results: A total of 746 resected lesions were included in the study, with a 4.5 mm mean size (range, 1–35 mm). The major pathological breakdowns were as follows: 64.3% (480/746) were adenomas, and 5.0% (37/746) were intraepithelial adenocarcinomas (Tis lesions). No residuals were observed in any of the 37 Tis lesions (mean size, 15.3 mm). Adverse events included bleeding (0.4%) but no perforation.ConclusionsNIRBS allowed the resection of multiple lesions with simplicity because of the non-injection and without perforating due to the minimal burn effect of the bipolar snare set in the soft coagulation mode. Therefore, NIRBS can be used to resect adenomatous lesions easily, including Tis lesions, from small to large lesions without leaving residuals.


  • Recent advances of endoscopic retrograde cholangiopancreatography using balloon assisted endoscopy for pancreaticobiliary diseases in patients with surgically altered anatomy: Therapeutic strategy and management of difficult cases

    by Masaaki Shimatani, Toshiyuki Mitsuyama, Mitsuo Tokuhara, Masataka Masuda, Sachi Miyamoto, Takashi Ito, Koh Nakamaru, Tsukasa Ikeura, Makoto Takaoka, Makoto Naganuma, et al.

    Endoscopic retrograde cholangiopancreatography (ERCP) is an endoscopic modality established for diagnosis and treatment of pancreaticobiliary diseases. However ERCP in patients with surgically altered anatomy (SAA) has been difficult, and more invasive therapies have been primarily selected. The development of balloon assisted endoscopes (BAEs) innovatively facilitated ERCP in such patients. Recent advances of BAEs and other devices greatly contributed to increasing success of ERCP using BAEs (BAE‐ERCP). Furthermore, interventions using Endoscopic Ultrasound (EUS‐intervention) have been reported to be useful for pancreaticobiliary diseases in patients with SAA, which provide more options for endoscopic therapies and are also expected as a rescue therapy for difficult cases of BAE‐ERCP. In order to thoroughly complete endoscopic treatment for pancreaticobiliary diseases with SAA, it is important to standardize the BAE‐ERCP procedures based on the features of respective endoscopes and to establish a strategy for endoscopic treatment which includes analysis of BAE‐ERCP difficult cases and selection of cases for rescue therapy. In addition, it is essential to be acquainted with the characteristics of possible adverse events of the procedure and to be able to deal with them for safe accomplishment of endoscopic treatment.


  • Evaluation of complications after endoscopic retrograde cholangiopancreatography using a short type double balloon endoscope in patients with altered gastrointestinal anatomy: a single‐center retrospective study of 1,576 procedures

    by Mitsuo Tokuhara, Masaaki Shimatani, Toshiyuki Mitsuyama, Masataka Masuda, Takashi Ito, Sachi Miyamoto, Norimasa Fukata, Hideaki Miyoshi, Tsukasa Ikeura, Makoto Takaoka, et al.

    Background and Aim: Endoscopic retrograde cholangiopancreatography (ERCP) using balloon‐assisted endoscope such as double‐balloon endoscope is even effective for patients with surgically altered anatomy. Yet comprehensive studies on complications of ERCP using balloon‐assisted endoscope have not been made. We analyzed the characteristics and the causes of complications of ERCP using double‐balloon endoscope (DB‐ERCP) procedures and aimed to suggest effective managements.Methods: A total of 1576 procedures of DB‐ERCP in 714 patients with surgically altered gastrointestinal anatomy in our hospital were evaluated retrospectively using a statistic analysis.Results: The overall complication occurrence rate was 5.8%. By type of complications are perforation 3.2%, mucosal laceration 0.5%, hemorrhage 1.0%, pancreatitis 0.6%, respiratory disorder 0.4%, and others 0.2%. By type of surgical reconstruction methods were Roux‐en‐Y reconstruction with choledocho‐jejunal anastomosis 4.2%, Roux‐en‐Y reconstruction without choledocho‐jejunal anastomosis 6.7%, pancreaticoduodenectomy 4.5%, pylorus preserving pancreaticoduodenectomy 4.2%, Billroth II gastrectomy (B‐II) 11.6%, and other reconstruction method (others) 7.4%. The contributing factors calculated by a multivariate analysis were B‐II (odds ratio: 1.864, 95% confidence interval: 1.001–3.471, P = 0.050) and the presence of naïve papilla (odds ratio: 3.268, 95% confidence interval: 1.426–7.490, P = 0.005).Conclusions: DB‐ERCP is a safe method with a total complication rate of 5.8% that could be considered within an acceptable range. The most common complication was the injury of the digestive tract such as perforation. Affecting risk factors for complications were B‐II and the presence of naïve papilla. DB‐ERCP procedures should be performed carefully of these factors.