Yuka Miura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuka Miura has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Hiromi Sanada
Ishikawa Prefectural Nursing University, Ishikawa, Japan
4 shared publications - Gojiro Nakagami
Global Nursing Research Center, Graduate School of Medicine The University of Tokyo Tokyo Japan
3 shared publications - Haruka Tohara
Department of Dysphagia Rehabilitation, Department of Gerontology and Gerodontology, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 113-8510, Japan
2 shared publications - Ayumi Amemiya
Graduate School of Nursing, Chiba University, Chiba, Japan
1 shared publication - Eiichi Saitoh
Department of Rehabilitation Medicine I, School of Medicine, Fujita Health University, Toyoake 470-1192, Japan
1 shared publication Erina Matsushima
Department of Nursing Physiology, Graduate School of Nursing, Chiba University
1 shared publication
Latest Publications
- 29 December 2020
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 23 (2) , 147-152
Evaluation of bowel preparation before colonoscopy by ultrasonographic monitoring of colonic fecal retention: a case series
Aims: While bowel preparation for colonoscopy is the key to successful examination, taking laxatives and showing stools to others causes both physical and mental distress to the patient. Thus, an alternative method to evaluation bowel preparation is necessary. In the current study, we studied the colonic fecal retention by ultrasonography (US) and examined the US finding which reflected completion of BP. Material and methods: The subjects were outpatients who underwent colonoscopy. This report summarizes the ultrasonographic images of patients who underwent multiple US examinations for all five sites of the colon just before, during, and immediately after bowel preparation. According to the standard protocol, the patients took 2 L of polyethylene glycol-ascorbic acid as a laxative, which was discontinued when the nurse visually judged the stool to be clear. Results: Seven patients in their 50s–80s, none of whom were unable to complete a colonoscopy due to residual feces were included in study. Following bowel preparation, the US images showed anechoic areas with haustration in four or all five areas of the colon. Three of the seven patients received low-dose laxatives (1.1–1.2 L); all three had watery stools in three or more colon areas and none of them were constipated at the time of taking 1 L of laxatives. Conclusions: Completion of bowel preparation can be assessed by the observation of anechoic areas with haustration in multiple colonic sites by ultrasonography.
- 29 December 2020
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 23 (2) , 147-152
Evaluation of bowel preparation before colonoscopy by ultrasonographic monitoring of colonic fecal retention: a case series
Aims: While bowel preparation for colonoscopy is the key to successful examination, taking laxatives and showing stools to others causes both physical and mental distress to the patient. Thus, an alternative method to evaluation bowel preparation is necessary. In the current study, we studied the colonic fecal retention by ultrasonography (US) and examined the US finding which reflected completion of BP. Material and methods: The subjects were outpatients who underwent colonoscopy. This report summarizes the ultrasonographic images of patients who underwent multiple US examinations for all five sites of the colon just before, during, and immediately after bowel preparation. According to the standard protocol, the patients took 2 L of polyethylene glycol-ascorbic acid as a laxative, which was discontinued when the nurse visually judged the stool to be clear. Results: Seven patients in their 50s–80s, none of whom were unable to complete a colonoscopy due to residual feces were included in study. Following bowel preparation, the US images showed anechoic areas with haustration in four or all five areas of the colon. Three of the seven patients received low-dose laxatives (1.1–1.2 L); all three had watery stools in three or more colon areas and none of them were constipated at the time of taking 1 L of laxatives. Conclusions: Completion of bowel preparation can be assessed by the observation of anechoic areas with haustration in multiple colonic sites by ultrasonography.
- 5 September 2020
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 22 (3) , 299-304
The association between jaw-opening strength, geniohyoid muscle thickness and echo intensity measured by ultrasound
Aim: Jaw-opening strength is an indicator of swallowing function including hyoid bone elevation. Geniohyoid muscles play an important role during hyoid bone elevation. This study aimed to investigate whether geniohyoid muscle thickness and echo intensity measured by ultrasonography were related to jaw-opening strength.Material and methods: Sixty-eight participants (39 men) with an average age of 77±7.7 years were recruited from a functional training health care facility. We measured muscle thickness and echo intensity of the geniohyoid muscle on transverse ultrasound images.Results: Age, calf circumference, grip strength, muscle thickness and echo intensity were significantly associated with jaw-opening strength in univariate analyses. After adjusting for grip strength in multiple regression analysis, geniohyoid muscle thickness and echo intensity were significantly associated with jaw-opening strength (β=0.29 for muscle thickness, β=−0.26 for echo intensity).Conclusions: There was a positive correlation between geniohyoid muscle thickness and jaw-opening strength; echo intensity negatively correlated with jaw-opening strength. Ultrasound evaluation of geniohyoid muscle status provides important information about maintaining jaw-opening strength.
- 5 September 2020
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 22 (3) , 299-304
The association between jaw-opening strength, geniohyoid muscle thickness and echo intensity measured by ultrasound
Aim: Jaw-opening strength is an indicator of swallowing function including hyoid bone elevation. Geniohyoid muscles play an important role during hyoid bone elevation. This study aimed to investigate whether geniohyoid muscle thickness and echo intensity measured by ultrasonography were related to jaw-opening strength.Material and methods: Sixty-eight participants (39 men) with an average age of 77±7.7 years were recruited from a functional training health care facility. We measured muscle thickness and echo intensity of the geniohyoid muscle on transverse ultrasound images.Results: Age, calf circumference, grip strength, muscle thickness and echo intensity were significantly associated with jaw-opening strength in univariate analyses. After adjusting for grip strength in multiple regression analysis, geniohyoid muscle thickness and echo intensity were significantly associated with jaw-opening strength (β=0.29 for muscle thickness, β=−0.26 for echo intensity).Conclusions: There was a positive correlation between geniohyoid muscle thickness and jaw-opening strength; echo intensity negatively correlated with jaw-opening strength. Ultrasound evaluation of geniohyoid muscle status provides important information about maintaining jaw-opening strength.
- Open Access
- 27 February 2020
- Published by MDPI AG in Healthcare
- Vol. 8 (1) , 50
Effectiveness of Swallowing Care on Safe Oral Intake Using Ultrasound-Based Observation of Residues in the Epiglottis Valley: A Pragmatic, Quasi-Experimental Study
The demand for methods to ensure safe oral consumption of food and liquids in order to prevent aspiration pneumonia has increased over the last decade. This study investigated the safety of swallowing care selected by adding ultrasound-based observation, evaluated its efficacy, and determined effective content of selected swallowing care. The study employed a pragmatic quasi-experimental research design. Participants were 12 community-dwelling adult patients (age: 44–91 years) who had experienced choking within 1 month prior to the study. After the control phase, in which conventional swallowing care was provided, trained nurses provided ultrasound observation-based swallowing care for a minimum period of 2 weeks. Outcome measurements were compared across three points, namely T1—beginning of the control phase, T2 and T3—before and end of the intervention phase. The mean durations of intervention were 30.8 days in the control phase and 36.5 days in the intervention phase. Pneumonia and suffocation did not occur in the control phase or the intervention phase. The safe intake food level and the food intake level score significantly improved during the intervention phase (p = 0.032 and 0.017, respectively) by adding eating training based on the ultrasound observation. However, there was no significant improvement in the strength of the muscle related to swallowing by the selected basic training. Our results suggest that swallowing care selected based on the ultrasound observation, especially eating training, safely improved safe oral intake among community-dwelling adults with swallowing dysfunction.
- 27 February 2020
- Published by MDPI AG in Healthcare
- Vol. 8 (1) , 50
Open AccessEffectiveness of Swallowing Care on Safe Oral Intake Using Ultrasound-Based Observation of Residues in the Epiglottis Valley: A Pragmatic, Quasi-Experimental Study
The demand for methods to ensure safe oral consumption of food and liquids in order to prevent aspiration pneumonia has increased over the last decade. This study investigated the safety of swallowing care selected by adding ultrasound-based observation, evaluated its efficacy, and determined effective content of selected swallowing care. The study employed a pragmatic quasi-experimental research design. Participants were 12 community-dwelling adult patients (age: 44–91 years) who had experienced choking within 1 month prior to the study. After the control phase, in which conventional swallowing care was provided, trained nurses provided ultrasound observation-based swallowing care for a minimum period of 2 weeks. Outcome measurements were compared across three points, namely T1—beginning of the control phase, T2 and T3—before and end of the intervention phase. The mean durations of intervention were 30.8 days in the control phase and 36.5 days in the intervention phase. Pneumonia and suffocation did not occur in the control phase or the intervention phase. The safe intake food level and the food intake level score significantly improved during the intervention phase (p = 0.032 and 0.017, respectively) by adding eating training based on the ultrasound observation. However, there was no significant improvement in the strength of the muscle related to swallowing by the selected basic training. Our results suggest that swallowing care selected based on the ultrasound observation, especially eating training, safely improved safe oral intake among community-dwelling adults with swallowing dysfunction.
- Open Access
- 12 February 2018
- Published by MDPI AG in Healthcare
- Vol. 6 (1) , 15
A Randomized Controlled Trial to Investigate the Effectiveness of the Prevention of Aspiration Pneumonia Using Recommendations for Swallowing Care Guided by Ultrasound Examination
Prevention for aspiration pneumonia requires assessment of aspiration and adequate swallowing care. This randomized controlled trial aimed to investigate the effectiveness of ultrasound examination and recommendations for swallowing care for the reduction of aspiration and pharyngeal post-swallow residue as compared with standard swallowing care. Twenty-three participants were randomized to the intervention group and 23 to the control group. The intervention consisted of four ultrasound examinations during mealtimes and recommendations for swallowing care every 2 weeks during an 8 week period. No recommendations concerning swallowing care based on ultrasound examinations were provided to the control group. The frequency of aspiration or residue was defined as x/y × 100% when aspiration or residue were detected x times from y times concerning the total ultrasound measurements. The proportion of the residents with reduced frequency of aspiration which was detected by ultrasonography at eight weeks were 4.3% in the intervention group and 0% in the control group. The median reduction in the frequency of aspiration and residue in the intervention group was 31%, and that in the control group was 11%. In conclusion, swallowing care guided by frequent ultrasound examinations during mealtimes had a trend of reducing the frequency of aspiration and residue during an 8-week period in individuals relative to standard swallowing care alone.
- 12 February 2018
- Published by MDPI AG in Healthcare
- Vol. 6 (1) , 15
Open AccessA Randomized Controlled Trial to Investigate the Effectiveness of the Prevention of Aspiration Pneumonia Using Recommendations for Swallowing Care Guided by Ultrasound Examination
Prevention for aspiration pneumonia requires assessment of aspiration and adequate swallowing care. This randomized controlled trial aimed to investigate the effectiveness of ultrasound examination and recommendations for swallowing care for the reduction of aspiration and pharyngeal post-swallow residue as compared with standard swallowing care. Twenty-three participants were randomized to the intervention group and 23 to the control group. The intervention consisted of four ultrasound examinations during mealtimes and recommendations for swallowing care every 2 weeks during an 8 week period. No recommendations concerning swallowing care based on ultrasound examinations were provided to the control group. The frequency of aspiration or residue was defined as x/y × 100% when aspiration or residue were detected x times from y times concerning the total ultrasound measurements. The proportion of the residents with reduced frequency of aspiration which was detected by ultrasonography at eight weeks were 4.3% in the intervention group and 0% in the control group. The median reduction in the frequency of aspiration and residue in the intervention group was 31%, and that in the control group was 11%. In conclusion, swallowing care guided by frequent ultrasound examinations during mealtimes had a trend of reducing the frequency of aspiration and residue during an 8-week period in individuals relative to standard swallowing care alone.