WWWilli L. Wagner

Willi L. Wagner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Willi L. Wagner has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Characterization of transient and progressive pulmonary fibrosis by spatially correlated phase contrast microCT, classical histopathology and atomic force microscopy

    by Lorenzo D’aMico, Angelika Svetlove, Elena Longo, Ruth Meyer, Beatrice Senigagliesi, Giulia Saccomano, Philipp Nolte, Willi L. Wagner, Mark O. Wielpütz, Dominik H.W. Leitz, et al.


  • Plant-Derived Carbohydrate Polymer as Sealant on Cornea

    by Betty Liu, Liao Matthew, Willi L Wagner, Hassan A Khalil, Zi Chen, Steven J Mentzer

    An abstract is unavailable. This article is available as a PDF only.

  • Open Access

    A closer look at high-energy X-ray-induced bubble formation during soft tissue imaging

    by R. Patrick Xian, Joseph Brunet, Yuze Huang, Willi L. Wagner, Peter D. Lee, Paul Tafforeau, Claire L. Walsh

    Improving the scalability of tissue imaging throughput with bright, coherent X-rays requires identifying and mitigating artifacts resulting from the interactions between X-rays and matter. At synchrotron sources, long-term imaging of soft tissues in solution can result in gas bubble formation or cavitation, which dramatically compromises image quality and integrity of the samples. By combining in-line phase-contrast cineradiography with operando gas chromatography, we were able to track the onset and evolution of high-energy X-ray-induced gas bubbles in ethanol-embedded soft tissue samples for tens of minutes (2 to 3 times the typical scan times). We demonstrate quantitatively that vacuum degassing of the sample during preparation can significantly delay bubble formation, offering up to a twofold improvement in dose tolerance, depending on the tissue type. However, once nucleated, bubble growth is faster in degassed than undegassed samples, indicating their distinct metastable states at bubble onset. Gas chromatography analysis shows increased solvent vaporization concurrent with bubble formation, yet the quantities of dissolved gases remain unchanged. Coupling features extracted from the radiographs with computational analysis of bubble characteristics, we uncover dose-controlled kinetics and nucleation site-specific growth. These hallmark signatures provide quantitative constraints on the driving mechanisms of bubble formation and growth. Overall, the observations highlight bubble formation as a critical, yet often overlooked hurdle in upscaling X-ray imaging for biological tissues and soft materials and we offer an empirical foundation for their understanding and imaging protocol optimization. More importantly, our approaches establish a top-down scheme to decipher the complex, multiscale radiation-matter interactions in these applications. Significance statement: Better probing the X-ray radiation dose limit of bubble formation in biological tissue and developing mitigation methods is essential for improving imaging techniques involving X-ray, such as synchrotron X-ray tomography or crystallography. Here, we combined operando gas chromatography with in-line X-ray phase-contrast radiography on human lung and brain tissue to investigate bubble formation under high-energy X-ray irradiation. We demonstrate that vacuum degassing delays bubble nucleation up to a factor two, depending on the tissue type. Gas chromatography analysis showed increased solvent vaporization during bubble formation; however, the quantities of dissolved gases remained unchanged. Moreover, depending on the nucleation site, bubble growth can be geometrically constrained by sample microstructure, which influence its dynamics.


  • Open Access

    Preparation of large biological samples for high-resolution, hierarchical, multi-modal imaging

    by J. Brunet, C. L. Walsh, W. L. Wagner, A. Bellier, C. Werlein, S. Marussi, D. D. Jonigk, S. E. Verleden, M. Ackermann, Peter D. Lee, et al.

    Imaging the different scales of biological tissue is essential for understanding healthy organ behavior and pathophysiological changes. X-ray micro-tomography using both laboratory (µCT) and synchrotron sources (sCT) is a promising tool to image the 3D morphology at the macro- and micro-scale of large samples, including intact human organs. Preparation of large samples for high resolution imaging techniques remains a challenge due to limitations with current methods, such as sample shrinkage, insufficient contrast, movement of the sample and bubble formation during mounting or scanning. Here, we describe a protocol to prepare, stabilize, and image large soft-tissue samples with X-ray microtomography. We demonstrate the protocol using intact human organs and Hierarchical Phase-Contrast Tomography (HiP-CT) imaging at the European Synchrotron Radiation Facility, but the protocol is equally applicable to a range of biological samples, including complete organisms, for both laboratory and synchrotron source tomography. Our protocol enhances the contrast of the sample, while preventing sample motion during the scan, even in case of different sample orientations. Bubbles trapped during mounting and those formed during scanning (in case of synchrotron X-ray imaging) are mitigated by multiple degassing steps. The sample preparation is also compatible with magnetic resonance imaging (MRI), CT, and histological observation. We describe a protocol for sample preparation and mounting which requires 25 to 34 days for a large organ such as an intact human brain or heart. This preparation time varies depending on the composition, size, and fragility of the tissue. Use of the protocol enables scanning of intact organs with a diameter of 150 mm with a local pixel size of one micron using HiP-CT.


  • Open Access

    A multiscale X-ray phase-contrast tomography dataset of whole human left lung

    by R. Patrick Xian, Claire L. Walsh, Stijn E. Verleden, Willi L. Wagner, Alexandre Bellier, Sebastian Marussi, Maximilian Ackermann, Danny D. Jonigk, Joseph Jacob, Peter D. Lee, et al.

    Technological advancements in X-ray imaging using bright and coherent synchrotron sources now allows to decouple sample size and resolution, while maintaining high sensitivity to the microstructure of soft, partially dehydrated tissues. The recently developed imaging technique, hierarchical phase-contrast tomography, is a comprehensive approach to address the challenge of organ-scale (up to tens of centimeters) soft tissue imaging with resolution and sensitivity down to the cellular level. Using this technique, we imaged ex vivo an entire human left lung at an isotropic voxel size of 25.08 μ m along with local zooms down to 6.05 - 6.5 μ m and 2.45 - 2.5 μ m in voxel size. The high tissue contrast offered by the fourth-generation synchrotron source at the European Synchrotron Radiation Facility reveals complex multiscale anatomical constitution of the human lung from the macroscopic (centimeter) down to the microscopic (micrometer) scale. The dataset provides complete organ-scale 3D information of the secondary pulmonary lobules and delineates the microstructure of lung nodules with unprecedented detail.

  • Open Access

    Multiscale three-dimensional imaging of intact human organs down to the cellular scale using hierarchical phase-contrast tomography

    by C. Walsh, P. Tafforeau, Willi L. Wagner, D. J. Jafree, A. Bellier, C. Werlein, M. P. Kühnel, E. Boller, S. Walker-Samuel, J. L. Robertus, et al.

    Human organs are complex, three-dimensional and multiscale systems. Spatially mapping the human body down through its hierarchy, from entire organs to their individual functional units and specialised cells, is a major obstacle to fully understanding health and disease. To meet this challenge, we developed hierarchical phase-contrast tomography (HiP-CT), an X-ray phase propagation technique utilising the European Synchrotron Radiation Facility’s Extremely Brilliant Source: the world’s first high-energy 4 th generation X-ray source. HiP-CT enabled three-dimensional and non-destructive imaging at near-micron resolution in soft tissues at one hundred thousand times the voxel size whilst maintaining the organ’s structure. We applied HiP-CT to image five intact human parenchymal organs: brain, lung, heart, kidney and spleen. These were hierarchically assessed with HiP-CT, providing a structural overview of the whole organ alongside detail of the organ’s individual functional units and cells. The potential applications of HiP-CT were demonstrated through quantification and morphometry of glomeruli in an intact human kidney, and identification of regional changes to the architecture of the air-tissue interface and alveolar morphology in the lung of a deceased COVID-19 patient. Overall, we show that HiP-CT is a powerful tool which can provide a comprehensive picture of structural information for whole intact human organs, encompassing precise details on functional units and their constituent cells to better understand human health and disease.


  • Parvovirus B19-induced angiogenesis in fulminant myocarditis

    by Maximilian Ackermann, Willi L Wagner, Philipp Rellecke, Payam Akhyari, Udo Boeken, Petra Reinecke


  • Glycoconjugate Expression in the Tissue-Engineered Lung Scaffold after Murine Pneumonectomy

    by Robert D. Bennett, Alexandra B. Ysasi, Janeil M. Belle, Willi L. Wagner, Maximilian Ackermann, Moritz A. Konerding, Akira Tsuda, Steven J. Mentzer