Sam Keshen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sam Keshen has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Johnathan Robert Lex
Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
2 shared publications - Stephen J. Lewis
Toronto Western Hospital
2 shared publications - Amir Khoshbin
Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
1 shared publication - Amit Atrey
Division of Orthopaedic Surgery, University of Toronto, Toronto, Canada
1 shared publication - Behdad Ravarian
Hand Program, Division of Plastic, Reconstructive and Aesthetic Surgery, Toronto Western Hospital, University Health Network, Department of Surgery, affiliated with Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
1 shared publication - Bheeshma Ravi
Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
1 shared publication
Latest Publications
- Open Access
- 1 April 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (2)
Analysis of Trends in FDA-Recalled Hip Arthroplasty Devices
Background: Hip arthroplasty implants are classified as Class III medical devices by the US Food and Drug Administration (FDA), requiring rigorous evaluation to ensure safety and efficacy. While these standards aim to ensure safety, device recalls remain an essential component of postmarket surveillance to address unforeseen performance issues. The objective of this study was to characterize the frequency, causes, and regulatory origins of FDA-recalled hip arthroplasty implants, identifying trends in device failure and implications for patient safety. Methods: A retrospective review of the FDA's medical device recall database was conducted, focusing on implantable hip arthroplasty devices and assistive technology from 2002 to 2024. Data were categorized by device type, recall class, reason for recall, and regulatory approval pathway. Trends over time were analyzed using negative binomial regression. Results: Of 1,863 hip-related recall records screened, 771 implantable devices met inclusion criteria. Design flaws accounted for the most recalls (35.8%), followed by packaging (24.9%) and labelling errors (11.7%). Most recalls were Class II (94.3%) and approved through the 510(k) pathway (94.7%). The number of recalls peaked in 2014 and has declined in recent years (p < 0.001). Robotic-assisted and navigation-related systems accounted for 1.8% of recalls and were frequently associated with software-related design problems (57.1%). Conclusion: Most recalled hip implants were approved through the 510(k) pathway. However, this likely reflects the high volume of devices approved through this mechanism rather than inherent pathway risk. Design-related failures were most prevalent, often involving modular junctions or material degradation. Although robotic and navigation systems currently account for a small minority of recalls, they introduce novel, distinct software-related failure modes that warrant continued postmarket surveillance as these technologies evolve. Level of Evidence: Level III . See Instructions for Authors for a complete description of levels of evidence.
- 1 April 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (2)
Open AccessAnalysis of Trends in FDA-Recalled Hip Arthroplasty Devices
Background: Hip arthroplasty implants are classified as Class III medical devices by the US Food and Drug Administration (FDA), requiring rigorous evaluation to ensure safety and efficacy. While these standards aim to ensure safety, device recalls remain an essential component of postmarket surveillance to address unforeseen performance issues. The objective of this study was to characterize the frequency, causes, and regulatory origins of FDA-recalled hip arthroplasty implants, identifying trends in device failure and implications for patient safety. Methods: A retrospective review of the FDA's medical device recall database was conducted, focusing on implantable hip arthroplasty devices and assistive technology from 2002 to 2024. Data were categorized by device type, recall class, reason for recall, and regulatory approval pathway. Trends over time were analyzed using negative binomial regression. Results: Of 1,863 hip-related recall records screened, 771 implantable devices met inclusion criteria. Design flaws accounted for the most recalls (35.8%), followed by packaging (24.9%) and labelling errors (11.7%). Most recalls were Class II (94.3%) and approved through the 510(k) pathway (94.7%). The number of recalls peaked in 2014 and has declined in recent years (p < 0.001). Robotic-assisted and navigation-related systems accounted for 1.8% of recalls and were frequently associated with software-related design problems (57.1%). Conclusion: Most recalled hip implants were approved through the 510(k) pathway. However, this likely reflects the high volume of devices approved through this mechanism rather than inherent pathway risk. Design-related failures were most prevalent, often involving modular junctions or material degradation. Although robotic and navigation systems currently account for a small minority of recalls, they introduce novel, distinct software-related failure modes that warrant continued postmarket surveillance as these technologies evolve. Level of Evidence: Level III . See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 1 January 2026
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 16 (1)
Masquelet Technique for Salvage of Failed Vascularized Fibular Graft Nonunion After Humeral Tumor Resection
Case: Diaphyseal nonunions after bone tumor resection present a significant reconstructive challenge. We report a 39-year-old woman who developed a diaphyseal humeral nonunion after giant cell tumor resection and reconstruction with vascularized fibula graft. She presented with symptomatic segmental bone loss and hardware failure. Two-stage Masquelet-induced membrane procedure was performed, resulting in complete union and excellent functional recovery at 12 months postoperatively. Conclusion: This case highlights the potential of the Masquelet technique in reconstruction of refractory nonunions despite previous failed reconstructive attempts.
- 1 January 2026
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 16 (1)
Open AccessMasquelet Technique for Salvage of Failed Vascularized Fibular Graft Nonunion After Humeral Tumor Resection
Case: Diaphyseal nonunions after bone tumor resection present a significant reconstructive challenge. We report a 39-year-old woman who developed a diaphyseal humeral nonunion after giant cell tumor resection and reconstruction with vascularized fibula graft. She presented with symptomatic segmental bone loss and hardware failure. Two-stage Masquelet-induced membrane procedure was performed, resulting in complete union and excellent functional recovery at 12 months postoperatively. Conclusion: This case highlights the potential of the Masquelet technique in reconstruction of refractory nonunions despite previous failed reconstructive attempts.
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (3)
Open Pelvic Ring Injury Following Childbirth Treated with External Fixation
Case: Labor-induced pelvic injuries are uncommon but associated with significant morbidity. We present a case of a 39-year-old primigravida woman who sustained an intrapartum open pelvic ring injury during vaginal delivery. The patient was treated with irrigation and debridement, external fixation, and a short course of prophylactic antibiotics with good result. Conclusion: Management of peripartum pelvic injuries should begin with standard trauma protocols for resuscitation. Surgical management is indicated for pelvic diastasis greater than 40 mm and for open injuries. Irrigation and debridement, followed by definitive fixation with an external fixator, is an effective treatment modality and avoids leaving implanted hardware.
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (3)
Open Pelvic Ring Injury Following Childbirth Treated with External Fixation
Case: Labor-induced pelvic injuries are uncommon but associated with significant morbidity. We present a case of a 39-year-old primigravida woman who sustained an intrapartum open pelvic ring injury during vaginal delivery. The patient was treated with irrigation and debridement, external fixation, and a short course of prophylactic antibiotics with good result. Conclusion: Management of peripartum pelvic injuries should begin with standard trauma protocols for resuscitation. Surgical management is indicated for pelvic diastasis greater than 40 mm and for open injuries. Irrigation and debridement, followed by definitive fixation with an external fixator, is an effective treatment modality and avoids leaving implanted hardware.
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 11 (3)
Use of an Intramedullary Nail to Guide Distal Femoral Resection in Primary Total Knee Arthroplasty
Case: A 67-year-old female patient presented for total knee arthroplasty (TKA) 4 years after receiving an antegrade femoral nail for bisphosphonate-induced femur fracture. She underwent a single-stage procedure with retention of femoral hardware. The femoral nail was used as a surrogate guide to reference the anatomical axis of the femur to position the distal femoral cutting block with good results. Conclusion: TKA is possible in patients with femoral intramedullary hardware without the need for hardware removal or extramedullary referencing. This report highlights a technique for the alignment of the femoral component by using the implanted femoral nail as an in situ guide for the placement of the distal femoral cutting block.
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 11 (3)
Use of an Intramedullary Nail to Guide Distal Femoral Resection in Primary Total Knee Arthroplasty
Case: A 67-year-old female patient presented for total knee arthroplasty (TKA) 4 years after receiving an antegrade femoral nail for bisphosphonate-induced femur fracture. She underwent a single-stage procedure with retention of femoral hardware. The femoral nail was used as a surrogate guide to reference the anatomical axis of the femur to position the distal femoral cutting block with good results. Conclusion: TKA is possible in patients with femoral intramedullary hardware without the need for hardware removal or extramedullary referencing. This report highlights a technique for the alignment of the femoral component by using the implanted femoral nail as an in situ guide for the placement of the distal femoral cutting block.
- 28 September 2020
- Published by Springer Nature in Spine Deformity
- Vol. 9 (2) , 609-614
Lumbosacral osteotomy to correct PI-LL mismatch in the presence of abnormally high pelvic incidence
Study design A case report. Summary of background data It is important to achieve optimal sagittal balance in spinal deformity surgery by matching LL to PI. A Lumbar osteotomy to increase lordosis is often the method used to achieve this in adult patients. However, in patients with high PI with compensatory lumbar hyperlordosis, providing further lordosis does not address the root cause. The paper will describe a technique of lumbosacral osteotomy to address sagittal malalignment with associated coronal imbalance and pelvic incidence (PI)—lumbar lordosis (LL) mismatch. Methods A 16-year-old female patient presented with low back pain and right leg pain. Standing anteroposterior X-ray showed scoliosis with a Cobb angle of 34º and 5.7 cm of coronal imbalance. Lateral X-ray showed a sacralized L5 with a PI of 85º and LL of 47º. Pedicle subtraction osteotomy through the sacralized L5 addressed the malalignment secondary to a high PI-LL mismatch of 38º. Results Following alar resection, an osteotomy was performed below the L5 pedicles. The cranial parts including the superior endplate and intervertebral disc were removed. Osteotomy closure was achieved using the central rod technique. L5 incidence was reduced from 59º to 33º with reduced coronal malalignment. Back pain was significantly improved and PI-LL mismatch was improved to 10º two years post-operatively with no local loss of sagittal correction. Conclusions A lumbosacral osteotomy at the lumbosacral junction is useful to improve high PI – LL mismatch in patients with abnormally high PI with compensatory lumbar hyperlordosis.
- 28 September 2020
- Published by Springer Nature in Spine Deformity
- Vol. 9 (2) , 609-614
Lumbosacral osteotomy to correct PI-LL mismatch in the presence of abnormally high pelvic incidence
Study design A case report. Summary of background data It is important to achieve optimal sagittal balance in spinal deformity surgery by matching LL to PI. A Lumbar osteotomy to increase lordosis is often the method used to achieve this in adult patients. However, in patients with high PI with compensatory lumbar hyperlordosis, providing further lordosis does not address the root cause. The paper will describe a technique of lumbosacral osteotomy to address sagittal malalignment with associated coronal imbalance and pelvic incidence (PI)—lumbar lordosis (LL) mismatch. Methods A 16-year-old female patient presented with low back pain and right leg pain. Standing anteroposterior X-ray showed scoliosis with a Cobb angle of 34º and 5.7 cm of coronal imbalance. Lateral X-ray showed a sacralized L5 with a PI of 85º and LL of 47º. Pedicle subtraction osteotomy through the sacralized L5 addressed the malalignment secondary to a high PI-LL mismatch of 38º. Results Following alar resection, an osteotomy was performed below the L5 pedicles. The cranial parts including the superior endplate and intervertebral disc were removed. Osteotomy closure was achieved using the central rod technique. L5 incidence was reduced from 59º to 33º with reduced coronal malalignment. Back pain was significantly improved and PI-LL mismatch was improved to 10º two years post-operatively with no local loss of sagittal correction. Conclusions A lumbosacral osteotomy at the lumbosacral junction is useful to improve high PI – LL mismatch in patients with abnormally high PI with compensatory lumbar hyperlordosis.
- Open Access
- 1 March 2020
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 63 (2) , 210-217
Accuracy Analysis of Iliac Screw Using Freehand Technique in Spinal Surgery : Relation between Screw Breach and Revision Surgery
Objective : To analyze the accuracy of iliac screws using freehand technique performed by the same surgeon. We also analyzed how the breach of iliac screws was related to the clinical symptoms resulting in revision surgery. Methods : From January 2009 to November 2015, 100 patients (193 iliac screws) were analyzed using postoperative computed tomography scans. The breaches were classified based on the superior, inferior, lateral, and medial iliac wall violation by the screw. According to the length of screw extrusion, the classification grades were as follows : grade 1, screw extrusion <1 cm; grade II, 1 cm <= screw extrusion <2 cm; grade III, 2 cm <= screw extrusion <3 cm; and grade IV, 3 cm <= screw extrusion. We also reviewed the revision surgery associated with iliac screw misplacement. Results : Of the 193 inserted screws, 169 were correctly located and 24 were misplaced screws. There were eight grade I, six grade II, six grade III, and four grade IV screw breaches, and 11, 8, 2, and 3 screws violated the medial, lateral, superior, and inferior walls, respectively. Four revision surgeries were performed for the grade III or IV iliac screw breaches in the lateral or inferior direction with respect to its related symptoms. Conclusion : In iliac screw placement, 12.4% breaches developed. Although most breaches were not problematic, symptomatic violations (2.1%) could result in revision surgery. Notably, the surgeon should keep in mind that lateral or inferior wall breaches longer than 2 cm can be risky and should be avoided.
- 1 March 2020
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 63 (2) , 210-217
Open AccessAccuracy Analysis of Iliac Screw Using Freehand Technique in Spinal Surgery : Relation between Screw Breach and Revision Surgery
Objective : To analyze the accuracy of iliac screws using freehand technique performed by the same surgeon. We also analyzed how the breach of iliac screws was related to the clinical symptoms resulting in revision surgery. Methods : From January 2009 to November 2015, 100 patients (193 iliac screws) were analyzed using postoperative computed tomography scans. The breaches were classified based on the superior, inferior, lateral, and medial iliac wall violation by the screw. According to the length of screw extrusion, the classification grades were as follows : grade 1, screw extrusion <1 cm; grade II, 1 cm <= screw extrusion <2 cm; grade III, 2 cm <= screw extrusion <3 cm; and grade IV, 3 cm <= screw extrusion. We also reviewed the revision surgery associated with iliac screw misplacement. Results : Of the 193 inserted screws, 169 were correctly located and 24 were misplaced screws. There were eight grade I, six grade II, six grade III, and four grade IV screw breaches, and 11, 8, 2, and 3 screws violated the medial, lateral, superior, and inferior walls, respectively. Four revision surgeries were performed for the grade III or IV iliac screw breaches in the lateral or inferior direction with respect to its related symptoms. Conclusion : In iliac screw placement, 12.4% breaches developed. Although most breaches were not problematic, symptomatic violations (2.1%) could result in revision surgery. Notably, the surgeon should keep in mind that lateral or inferior wall breaches longer than 2 cm can be risky and should be avoided.