CLChang Liu

Chang Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chang Liu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Active Explicit Model Predictive Current Control of Power Conversion System in Grid-Connected BESS

    by Mingming Zhang, Chang Liu, Mian Li

    An active explicit model predictive current controller (APCC) is developed for the power conversion system (PCS) in grid-connected battery energy storage systems (BESS). The accurate discrete-time model of the PCS is derived, with both the system and input matrices expressed as scaled rotation matrices, significantly simplifying controller design. The current reference tracking problem, considering BESS dc-link voltage variations, is formulated as a multiparametric quadratic program, where the feasible current domain is divided into multiple critical regions. The optimal control law in each region is shown to be a piecewise affine function of the current tracking error and can be pre-computed explicitly, enabling efficient real-time implementation in industrial power drives. A disturbance observer is combined with the explicit predictive controller to reject lumped disturbances, and the offset-free tracking capability of the APCC has been theoretically proven. The proposed controller is validated on a 20 kVA experimental platform using an industrial DSP (TMS320F28335). Experimental results demonstrate that the APCC achieves prompt transient response, offset-free tracking performance in steady state, and enhanced robustness against grid variations and system uncertainties.


  • Main Circuit's Parametric Optimal Design Counting Inconsistent Battery Parameters and Control of 35 kV Large-Capacity Transformer-Less BESS

    by Chang Liu, Xianqiang Shi, Rui Li, Xu Cai

    A large quantity of battery cells are required by each phase of the 35 kV large-capacity transformer-less battery energy storage system (LCTL-BESS) based on cascaded H-bridge converter (CHBC) and the parameters of battery cells are inconsistent. The inconsistencies of battery parameters should be fully considered in main circuit parameter design to improve the system's adaptability to them, thus delaying the aging rate of battery and ensuring the safety and high efficiency utilization during the whole life cycle of battery. The cascaded number of power modules in per phase is the most important main circuit parameter of system and has a significant influence on system performance, which should be optimized by considering system efficiency and safety comprehensively. Since the system efficiency and safety evaluation model are closely related to inconsistent battery parameters, it is impossible to establish them under different number of power modules based on the detailed parameters of each battery cell. Therefore, a method to establish system efficiency and safety evaluation model based on the capacity distribution of the battery cells is proposed. The massive battery cell parameter identifications and data processing are avoided. Our proposed method provides theoretical guidance for the optimization design of main circuit for LCTL-BESS. Additionally, the power and energy balancing control of 35 kV LCTL-BESS are investigated, and a novel energy balancing control strategy among modules considering the DC link voltage and state of charge (SOC) are proposed under the nearest level modulation (NLM), which can promise both the balancing effect and AC side output performance. Finally, the validity of the proposed parameter design method and the control strategy are proved through off-line simulation model.


  • Four Quadrant Operation Control for Cascade H-Bridge Converter-Based Battery Energy Storage System

    by Xiqi Wu, Chang Liu, Rui Li, Fubao Wu, Xu Cai

    Exposure to battery microcycles under low power factor for cascaded H-bridge (CHB) converter-based battery energy storage system (BESS) increases additional charge throughput and may accelerate lithium-ion battery cycle-aging. Aiming to eliminating battery microcycles current and further extend operating range, this paper proposes a complete four-quadrant operation control strategy for CHB-based BESS to avoid detrimental effects on cells. First, the battery current components with LC filter are decomposed quantitatively and feasible range of avoiding microcycles under four-quadrant operation are obtained theoretically. By vector decomposition of closed-loop generated modulation phase voltage, the grid-side power factor is not unaffected and all submodules power factor are compensated without exceeding the microcycles boundary. Besides, unified modulation strategy considering eliminating microcycles and inner-phase state of charge (SOC) equalization is analyzed and the system control diagram is given. At last, a 35kV/12MW/24MWh BESS simulation model and a downscaled prototype system with four cascaded 25.6V-rated Lithium-battery modules are built for principal validation. The experimental results at two different low power factor cases verify the feasibility of the proposed control strategy.


  • Low-Frequency Current Ripple Minimization of Single-Star Bridge Cells-Based Battery Energy Storage System Using Optimal Third Harmonic Voltage Injection

    by Xianqiang Shi, Chang Liu, Chen Zhang, Rui Li, Xu Cai

    Single-star bridge cell (SSBC) based multilevel converters are a promising solution for constructing high-voltage and large-capacity battery energy storage systems (BESSs) in power systems. Nevertheless, an undesirable second harmonic current (SHC) will be generated in the battery units since the single-phase instantaneous power of the SSBC pulsates at twice the line frequency. Such SHC-dominated low-frequency current ripple not only shortens the lifespan of the BUs but also degrades the system's efficiency. However, this intrinsic issue is overlooked in recent studies. To this end, an SHC suppression scheme that makes full use of the residual modulation index of the system to inject an optimal third harmonic voltage (THV) is proposed. The phase of the THV is determined first, followed by a closed-loop control strategy to regulate its magnitude dynamically for achieving a minimum SHC within the modulation constraints. The scheme is implemented with the variables that already existed in the main control system, resulting in a low increase in cost. The adverse impact of the technique on the AC-side output characteristics is investigated quantitatively, and a modified design procedure for the DC filter network is presented to address this issue. Hardware-in-the-loop experiments are carried out to validate the technique.


  • Approach to Inertial Compensation of HVdc Offshore Wind Farms by MMC With Ultracapacitor Energy Storage Integration

    by Wu Zeng, Rui Li, Lei Huang, Chang Liu, Xu Cai

    Recent studies have shown that the grid connection of offshore wind farms through modular multilevel converter–high voltage direct current (MMC-HVdc) transmission system has brought low inertia issue. It is an urgent requirement for offshore wind farms to compensate for the inertia. After analysis and evaluation in this article, it is found that integrating an ultracapacitor energy storage system (UESS) into an MMC has an advantage comprehensively considering cost, size, and dynamic. Based on the evaluation, this article proposes an approach to inertial compensation of HVdc offshore wind farms by MMC-UESS integration. An ultracapacitor is selected as an energy storage element (ESE) for its high power density since the inertial response is a short-term response and it is hoped that added ESE does not significantly increase the size of an MMC submodule. Batteries with high energy density but low power density are not suitable for such applications. The optimal operating voltage of a UESS and the control scheme between MMC loops and inertial emulation are proposed in this article. Experimental results from real-time simulation and a downscaled prototype are presented to verify the effectiveness of the proposed method.


  • Open Access

    Application of new intelligent double end grounding circuit breaker circuit resistance measurement technology

    by Sui Dongpeng, Huang Fucu, Liu Chang, Zhao Ye, Wang Yanan, Guo Zhinan

    According to actual needs of the circuit breaker field measurement, by using induction coil as the basic principle of the proposed at both ends of the breaker is connected with the loop resistance test method. In this paper, we mainly study the circuit breakers at both ends of the ground state, circuit breaker loop resistance test design principle and theory model, solution method for the measurement of the small current signal criterion, research and development of the testing device, and through the two ends of the two devices on circuit breaker and GIS combination electric appliance grounding field test. Finally, to test this method and the traditional methods of test results were compared and analyzed, it is concluded that the two ends of the grounding circuit breaker loop resistance method can completely meet the needs of field maintenance and can improve the detection accuracy and instead of the traditional test methods.

  • Open Access

    Optimal short‐circuit current control of the grid‐forming converter during grid fault condition

    by Chang Liu, Xu Cai, Rui Li, Renxin Yang

    A considerable amount of rotating synchronous machines are being replaced by the increasing capacity of converter‐based resources, which has stimulated a demand for grid‐forming converters (GFCs) for grid supporting. The inertia and frequency responses of GFC are remarkably similar to those of synchronous generator (SG), but the inadequate capability of sourcing short‐circuit current of GFCs during grid fault can lead to several serious consequences. The low short‐circuit current level fails to trigger protection relays and cannot provide sustained voltage support during the fault or more effectively support the recovery of voltage after fault clearance. The short‐term overcurrent capability of GFC can be promoted either from the point of view of the power devices or from the topology of it. The overcurrent capability of converter is hard‐earned, so full use of it should be made. This paper proposes an optimal control strategy of short‐circuit current of GFC, which can enable the GFC to source the short‐circuit current with an optimal angle within the allowable magnitude. A detailed simulation model of the proposed method here is set up in PSCAD/EMTDC. The simulation results show that the proposed method can achieve better voltage supporting results compared with the traditional reactive support control.


  • Differentiation Power Control of Modules in Second-Life Battery Energy Storage System Based on Cascaded H-Bridge Converter

    by Chang Liu, Ning Gao, Xu Cai, Rui Li

    There is a possibility that second-life power batteries, which can store and deliver substantial energy, could satisfy the requirements of stationary energy storage applications. In this article, split second-life battery modules with good performance have been directly introduced to the dc sides of the H-bridges in cascaded H-bridge converter (CHBC) without complex manual dismantling, screening, and recombination of the battery cells. However, the severe discrepancies of the second-life battery modules' parameters can lead to overcharge, overdischarge, and underutilization of some battery modules' effective capacity simultaneously. To suitably integrate and control these widely different battery modules, a differentiation power control strategy based on the online battery parameter estimation method is proposed. Real-time online power allocation of the independent power modules according to the parameters of the battery modules is conducted by the strategy, which ensures that the charging/discharging trajectories of the second-life battery modules during a charging/discharging cycle will all arrive at their maximum/minimum values at the same time, whether the battery modules are in the same phase or different phases. The control range and capability of the strategy are also analyzed quantitatively. Finally, modeling, analysis, and experimental validation are performed on a downscaled prototype in the laboratory.