Ding Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ding Wu has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Cong Li
Dalian University of Technology
20 shared publications - Hongbin Ding
Key Laboratory of Materials Modification by Laser, Ion and Electron Beams, Chinese Ministry of Education, School of Physics, Dalian University of Technology, Dalian, 116024, China
14 shared publications - Ran Hai
Dalian University of Technology
12 shared publications Huace Wu
Key Laboratory of Materials Modification by Laser, Ion and Electron Beams (Dalian University of Technology), Ministry of Education, School of Physics, Dalian 116024, China
11 shared publicationsHongbin Ding
10 shared publicationsChunlei Feng
9 shared publications
Latest Publications
- 1 November 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 35 (11) , 115007
Early nitrogen emission and charge-state separation in nanosecond laser-produced tin plasma under varying pressures
The spatiotemporal evolution of nanosecond laser-produced Sn plasma was investigated under N 2 pressures from 10 −3 to 10 4 Pa using ICCD imaging and time- and space-resolved optical emission spectroscopy. The plasma evolution exhibits an early ‘fast’ process (100 ns)(10–10 3 Pa). The ‘fast’ process is characterized by continuum radiation and spatially extended N 2 /N 2 + emissions reaching several centimeters, likely arising from VUV/EUV-induced photoionization of ambient N 2 and subsequent collisional excitation by photoelectrons and secondary electrons. The ‘slow’ process is dominated by sequential emissions from Sn ions and neutral atoms. Spatially resolved spectra reveal clear charge-state-dependent separation (<∼50 Pa), with higher-charge-state ions located closer to the plume front and lower-charge-state ions and neutral atoms distributed farther behind. Self-electrostatic acceleration and pressure-dependent collisional and recombination processes are discussed as possible contributors to this ordering. Electron density ( n e ) and electron temperature ( T e ) were determined by Stark broadening and a spectral matching algorithm, respectively. Within the measured time delay range, n e decreases from approximately 3.0 × 10 25 to 4.0 × 10 23 m −3 , while T e decreases from approximately 3.2–1.0 eV. T e shows an apparent transition around 100 ns, corresponding to the fast-to-slow transition, whereas the late-stage decay of n e is strongly regulated by pressure-induced collisional confinement. These results provide a pressure-resolved picture of early background-gas activation and charge-state-dependent transport in laser-produced Sn plasma.
- 1 November 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 35 (11) , 115007
Early nitrogen emission and charge-state separation in nanosecond laser-produced tin plasma under varying pressures
The spatiotemporal evolution of nanosecond laser-produced Sn plasma was investigated under N 2 pressures from 10 −3 to 10 4 Pa using ICCD imaging and time- and space-resolved optical emission spectroscopy. The plasma evolution exhibits an early ‘fast’ process (100 ns)(10–10 3 Pa). The ‘fast’ process is characterized by continuum radiation and spatially extended N 2 /N 2 + emissions reaching several centimeters, likely arising from VUV/EUV-induced photoionization of ambient N 2 and subsequent collisional excitation by photoelectrons and secondary electrons. The ‘slow’ process is dominated by sequential emissions from Sn ions and neutral atoms. Spatially resolved spectra reveal clear charge-state-dependent separation (<∼50 Pa), with higher-charge-state ions located closer to the plume front and lower-charge-state ions and neutral atoms distributed farther behind. Self-electrostatic acceleration and pressure-dependent collisional and recombination processes are discussed as possible contributors to this ordering. Electron density ( n e ) and electron temperature ( T e ) were determined by Stark broadening and a spectral matching algorithm, respectively. Within the measured time delay range, n e decreases from approximately 3.0 × 10 25 to 4.0 × 10 23 m −3 , while T e decreases from approximately 3.2–1.0 eV. T e shows an apparent transition around 100 ns, corresponding to the fast-to-slow transition, whereas the late-stage decay of n e is strongly regulated by pressure-induced collisional confinement. These results provide a pressure-resolved picture of early background-gas activation and charge-state-dependent transport in laser-produced Sn plasma.
- 2 July 2026
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 28 (7) , 074002
Pure-element spectral matching for full-spectrum quantitative LIBS under vacuum toward fusion plasma–wall interaction diagnostics
Quantitative Laser-Induced Breakdown Spectroscopy (LIBS) under high vacuum is important for in situ diagnostics of plasma–wall interactions (PWI) in nuclear fusion devices. In this work, we proposed a Pure-Element Spectral Matching (PESM) method for full-spectrum quantitative LIBS analysis under vacuum conditions. In PESM, LIBS spectra of pure Fe, Cr, Ni, and Mo acquired under identical conditions were used as basis components, and alloy spectra were reconstructed through global spectral fitting to directly estimate elemental atomic fractions. The method was validated using Mo-containing Ni-based alloy reference materials at a pressure of 5×10−3 Pa. Compared with the univariate calibration method and Partial Least Squares (PLS) models, PESM achieved superior quantitative performance for four-element analysis, with an overall RMSE of 1.55%, MAE of 1.33%, and MAPE of 7.01% (averaged over all elements). By operating on the full spectrum, PESM avoids manual spectral-line selection and peak integration, thereby reducing operator-dependent uncertainty while retaining broader spectral information. These results demonstrated that PESM was a practical and calibration-light strategy for vacuum LIBS quantification and showed strong potential for fusion-relevant PWI diagnostics.
- 2 July 2026
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 28 (7) , 074002
Pure-element spectral matching for full-spectrum quantitative LIBS under vacuum toward fusion plasma–wall interaction diagnostics
Quantitative Laser-Induced Breakdown Spectroscopy (LIBS) under high vacuum is important for in situ diagnostics of plasma–wall interactions (PWI) in nuclear fusion devices. In this work, we proposed a Pure-Element Spectral Matching (PESM) method for full-spectrum quantitative LIBS analysis under vacuum conditions. In PESM, LIBS spectra of pure Fe, Cr, Ni, and Mo acquired under identical conditions were used as basis components, and alloy spectra were reconstructed through global spectral fitting to directly estimate elemental atomic fractions. The method was validated using Mo-containing Ni-based alloy reference materials at a pressure of 5×10−3 Pa. Compared with the univariate calibration method and Partial Least Squares (PLS) models, PESM achieved superior quantitative performance for four-element analysis, with an overall RMSE of 1.55%, MAE of 1.33%, and MAPE of 7.01% (averaged over all elements). By operating on the full spectrum, PESM avoids manual spectral-line selection and peak integration, thereby reducing operator-dependent uncertainty while retaining broader spectral information. These results demonstrated that PESM was a practical and calibration-light strategy for vacuum LIBS quantification and showed strong potential for fusion-relevant PWI diagnostics.
- 16 June 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (24) , 245601
Effect of laser wavelength on the detection limits of trace elements in Al–Li alloy samples by vacuum laser-induced breakdown spectroscopy
Laser wavelength plays a critical role in laser-matter coupling, plasma formation, and the analytical sensitivity of laser-induced breakdown spectroscopy (LIBS). In this study, the influence of three laser wavelengths (1064, 532, and 355 nm) on emission characteristics, limits of detection (LoD) of trace elements, plasma parameters, and ablation volume of Al–Li alloy samples was systematically investigated under a vacuum of 5 × 10 −5 mbar. At a constant laser fluence of 4 J cm −2 , set according to the operating conditions of the in‐situ LIBS system used for monitoring deposited impurities on the inner wall of the EAST tokamak, excitation with the 355 nm laser produced significantly stronger atomic emission signals, higher electron temperature ( T e ) and electron density ( n e ), and lower LoDs. This improvement is attributed to more efficient energy coupling between the laser and the sample surface at shorter wavelengths. Specifically, the LoDs of Mg, Cu, and Cr decreased from 0.253, 0.684, and 0.303 a.t. % at 1064 nm to 0.066, 0.142, and 0.018 a.t. % at 355 nm, respectively. In contrast, irradiation at 1064 nm resulted in a larger ablation volume and deeper craters, indicating that enhanced spectral signal intensity is not determined solely by the amount of ablated material but is also strongly governed by plasma excitation efficiency. These results demonstrate that LIBS at 355 nm offers significant potential for high-sensitivity, low-damage, in-situ detection of trace impurities in fusion-relevant materials.
- 16 June 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (24) , 245601
Effect of laser wavelength on the detection limits of trace elements in Al–Li alloy samples by vacuum laser-induced breakdown spectroscopy
Laser wavelength plays a critical role in laser-matter coupling, plasma formation, and the analytical sensitivity of laser-induced breakdown spectroscopy (LIBS). In this study, the influence of three laser wavelengths (1064, 532, and 355 nm) on emission characteristics, limits of detection (LoD) of trace elements, plasma parameters, and ablation volume of Al–Li alloy samples was systematically investigated under a vacuum of 5 × 10 −5 mbar. At a constant laser fluence of 4 J cm −2 , set according to the operating conditions of the in‐situ LIBS system used for monitoring deposited impurities on the inner wall of the EAST tokamak, excitation with the 355 nm laser produced significantly stronger atomic emission signals, higher electron temperature ( T e ) and electron density ( n e ), and lower LoDs. This improvement is attributed to more efficient energy coupling between the laser and the sample surface at shorter wavelengths. Specifically, the LoDs of Mg, Cu, and Cr decreased from 0.253, 0.684, and 0.303 a.t. % at 1064 nm to 0.066, 0.142, and 0.018 a.t. % at 355 nm, respectively. In contrast, irradiation at 1064 nm resulted in a larger ablation volume and deeper craters, indicating that enhanced spectral signal intensity is not determined solely by the amount of ablated material but is also strongly governed by plasma excitation efficiency. These results demonstrate that LIBS at 355 nm offers significant potential for high-sensitivity, low-damage, in-situ detection of trace impurities in fusion-relevant materials.
- 5 September 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (11) , 3111-3119
Data fusion of laser-induced breakdown spectroscopy and diffuse reflectance spectroscopy for improved quantitative analysis of EAST-like plasma-facing materials
A novel LIBS-DRS data fusion model was developed to provide more accurate quantification of tungsten impurities deposited on tokamak first walls.
- 5 September 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (11) , 3111-3119
Data fusion of laser-induced breakdown spectroscopy and diffuse reflectance spectroscopy for improved quantitative analysis of EAST-like plasma-facing materials
A novel LIBS-DRS data fusion model was developed to provide more accurate quantification of tungsten impurities deposited on tokamak first walls.
- Open Access
- 26 August 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (10)
Towards ultra-sensitive in-situ helium retention monitoring in high-Z fusion materials via combined LIBS and LID-QMS
In-situ monitoring of helium (He) retention in plasma-facing materials (PFMs) of nuclear fusion devices is critical for understanding plasma-wall interactions (PWIs). This study introduces a transformative approach to optimize He detection in high-Z materials—tungsten (W) and molybdenum (Mo)—using laser-induced breakdown spectroscopy (LIBS) under vacuum conditions. The He I 587.56 nm spectral line was identified as the optimal analytical signal for LIBS due to its dominant intensity and resilience to spectral interference from high-Z elements. By systematically optimizing gate delay timing and leveraging spatial plasma emission characteristics, a threefold improvement in signal-to-noise ratio (S/N) was achieved through the exclusion of core plasma emissions, where bremsstrahlung background and matrix interference are most pronounced. Quantitative calibration curves were established using laser-induced desorption quadrupole mass spectrometry (LID-QMS) as a reference, with internal standardization reducing prediction errors to ≤10%—significantly enhancing accuracy in the face of variable laser ablation rates. The achieved limits of detection (LODs) for He in Mo and W co-deposited layers are 0.72×1014 He/mm2 (0.09 at.%) and 0.84×1014 He/mm2 (0.11 at.%), respectively—the lowest reported values for high-Z materials to date. This work delivers critical calibration parameters and a robust methodology for in-situ LIBS diagnostics, addressing the long-standing challenge of real-time He retention monitoring in fusion devices. The proposed approach paves the way for practical applications in tokamaks such as ITER and EAST, enabling precise characterization of plasma-wall interactions and facilitating advancements in plasma-facing component design.
- 26 August 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (10)
Open AccessTowards ultra-sensitive in-situ helium retention monitoring in high-Z fusion materials via combined LIBS and LID-QMS
In-situ monitoring of helium (He) retention in plasma-facing materials (PFMs) of nuclear fusion devices is critical for understanding plasma-wall interactions (PWIs). This study introduces a transformative approach to optimize He detection in high-Z materials—tungsten (W) and molybdenum (Mo)—using laser-induced breakdown spectroscopy (LIBS) under vacuum conditions. The He I 587.56 nm spectral line was identified as the optimal analytical signal for LIBS due to its dominant intensity and resilience to spectral interference from high-Z elements. By systematically optimizing gate delay timing and leveraging spatial plasma emission characteristics, a threefold improvement in signal-to-noise ratio (S/N) was achieved through the exclusion of core plasma emissions, where bremsstrahlung background and matrix interference are most pronounced. Quantitative calibration curves were established using laser-induced desorption quadrupole mass spectrometry (LID-QMS) as a reference, with internal standardization reducing prediction errors to ≤10%—significantly enhancing accuracy in the face of variable laser ablation rates. The achieved limits of detection (LODs) for He in Mo and W co-deposited layers are 0.72×1014 He/mm2 (0.09 at.%) and 0.84×1014 He/mm2 (0.11 at.%), respectively—the lowest reported values for high-Z materials to date. This work delivers critical calibration parameters and a robust methodology for in-situ LIBS diagnostics, addressing the long-standing challenge of real-time He retention monitoring in fusion devices. The proposed approach paves the way for practical applications in tokamaks such as ITER and EAST, enabling precise characterization of plasma-wall interactions and facilitating advancements in plasma-facing component design.
- 8 July 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (9) , 2362-2372
Dynamics of laser-ablated molybdenum plasma in vacuum: a novel spectral matching algorithm based on Saha–Boltzmann equilibrium for ne and Te determination in fusion wall diagnostics
A spectral matching algorithm based on the Saha–Boltzmann distribution is proposed to determine the spatio-temporal evolution of Te and ne in laser-ablated molybdenum plasma in vacuum.
- 8 July 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (9) , 2362-2372
Dynamics of laser-ablated molybdenum plasma in vacuum: a novel spectral matching algorithm based on Saha–Boltzmann equilibrium for ne and Te determination in fusion wall diagnostics
A spectral matching algorithm based on the Saha–Boltzmann distribution is proposed to determine the spatio-temporal evolution of Te and ne in laser-ablated molybdenum plasma in vacuum.
- Open Access
- 12 June 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (7) , 075609
Thomson scattering diagnostics of electron density and electron temperature in cascade arc argon-helium and argon-neon mixture plasmas
The cascaded arc plasma source is a significant plasma-generating device capable of producing high-density, steady-state plasma in a low-pressure environment. The two most crucial physical parameters of the plasma are the electron density (n e ) and electron temperature (T e ). The laser Thomson scattering (LTS) technique provides an accurate method for measuring both n e and T e . In this study, we conducted diagnostic measurements of n e and T e for cascaded arc argon-helium (Ar-He) and argon-neon (Ar-Ne) mixture plasmas utilizing LTS technology. Furthermore, we explored the local thermodynamic equilibrium (LTE) state of the plasma by comparing the electron excitation temperature (T exc ) obtained through optical emission spectroscopy (OES) with T e measured via LTS. Our results indicate that varying the dopant ratios of the gas mixtures, alongside the experimental currents and background pressures, influences both n e and T e . Specifically, these parameters are inversely proportional to the dopant ratio, while they are directly proportional to the background pressure and discharge current. Notably, at the same dopant ratios, n e and T e are slightly elevated in the presence of Ne dopants compared to those with He dopants. Additionally, the observed differences between T exc and T e suggest that the cascaded arc mixture plasma deviates significantly from the LTE state. This deviation is directly proportional to the dopant ratio and inversely proportional to the discharge current. The findings contribute to a deeper understanding of multicomponent plasmas and potentially enhance the applications of cascaded arc mixture plasmas.
- 12 June 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (7) , 075609
Open AccessThomson scattering diagnostics of electron density and electron temperature in cascade arc argon-helium and argon-neon mixture plasmas
The cascaded arc plasma source is a significant plasma-generating device capable of producing high-density, steady-state plasma in a low-pressure environment. The two most crucial physical parameters of the plasma are the electron density (n e ) and electron temperature (T e ). The laser Thomson scattering (LTS) technique provides an accurate method for measuring both n e and T e . In this study, we conducted diagnostic measurements of n e and T e for cascaded arc argon-helium (Ar-He) and argon-neon (Ar-Ne) mixture plasmas utilizing LTS technology. Furthermore, we explored the local thermodynamic equilibrium (LTE) state of the plasma by comparing the electron excitation temperature (T exc ) obtained through optical emission spectroscopy (OES) with T e measured via LTS. Our results indicate that varying the dopant ratios of the gas mixtures, alongside the experimental currents and background pressures, influences both n e and T e . Specifically, these parameters are inversely proportional to the dopant ratio, while they are directly proportional to the background pressure and discharge current. Notably, at the same dopant ratios, n e and T e are slightly elevated in the presence of Ne dopants compared to those with He dopants. Additionally, the observed differences between T exc and T e suggest that the cascaded arc mixture plasma deviates significantly from the LTE state. This deviation is directly proportional to the dopant ratio and inversely proportional to the discharge current. The findings contribute to a deeper understanding of multicomponent plasmas and potentially enhance the applications of cascaded arc mixture plasmas.
- 5 June 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (8) , 2026-2037
Layer-resolving ability and model analysis of LIBS for multilayer samples with a four-layer structure under different focusing conditions
Research on LIBS depth profiling and modeling of multilayered deposited layers, as well as the resolving ability of Ni interlayers, provides data references and a parameter optimization scheme for in situ LIBS diagnosis.
- 5 June 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (8) , 2026-2037
Layer-resolving ability and model analysis of LIBS for multilayer samples with a four-layer structure under different focusing conditions
Research on LIBS depth profiling and modeling of multilayered deposited layers, as well as the resolving ability of Ni interlayers, provides data references and a parameter optimization scheme for in situ LIBS diagnosis.
- Open Access
- 22 January 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (3) , 762-774
Spatio-temporal evolution of laser ablation W plasma under low-pressure Ar gas and Ar plasma ambients
The spatio-temporal evolution of laser ablation W plasma under low-pressure conditions in a continuous Ar plasma ambient was investigated and compared to that in Ar gas ambient.
- 22 January 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (3) , 762-774
Open AccessSpatio-temporal evolution of laser ablation W plasma under low-pressure Ar gas and Ar plasma ambients
The spatio-temporal evolution of laser ablation W plasma under low-pressure conditions in a continuous Ar plasma ambient was investigated and compared to that in Ar gas ambient.