John A. Kramar
Research Subjects
Research Interests
John A. Kramar has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Natalia Farkas
USDA Forest Products Laboratory
4 shared publications - Antonio R. Montoro Bustos
Chemical Sciences Division, Material Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899-1070, United States
1 shared publication - Elijah Joel Petersen
National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
1 shared publication George Caceres
Chemical Sciences Division, Material Measurement Laboratory
1 shared publication- George W. Mulholland
Materials Research Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
1 shared publication - Hiromu Sakurai
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan
1 shared publication
Latest Publications
- Open Access
- 16 May 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (21) , 10999-11006
Derivation of Particle Number Concentration from the Size Distribution: Theory and Applications
The particle number concentration (PNC) in a suspension is a key measurand in nanotechnology. A common approach for deriving PNC is to divide the total mass concentration by the per-particle mass, calculated as density times volume. The volume is most frequently derived from the arithmetic mean diameter (AMD) of the size distribution. The harmonic mean volume (HMV) has also been used. Given a known size distribution, we show that the correct PNC is obtained by using the arithmetic mean volume (AMV). The AMD-based volume results in an overestimate in PNC that increases superlinearly with increasing coefficient of variation (CV), reaching 12% at CV = 0.2 for a normal distribution. HMV would yield a much greater overestimate, exceeding 50%. The error in the AMD-derived PNC shows only weak skew dependence, suggesting a simple approximate correction as a function of CV in the common situation where AMD and CV are known but the overall size distribution is unknown. Using published data sets of gold nanoparticles, we demonstrate an overall consistency of ±1.1% in comparing the PNC directly determined by single-particle inductively coupled plasma-mass spectrometry (spICP-MS) and the PNCs derived from AMV using size distributions independently measured by high-resolution scanning electron microscopy and spICP-MS. We further compare AMV and AMD-derived PNCs for well-characterized polystyrene nanoparticle standards, illustrating sensitivity to distributional characteristics along with common errors to avoid. Nanoparticles in environmental samples, food additives, and nanomedicines often have CVs greater than 0.3, for which uncorrected AMD-derived PNC errors can exceed 35%.
- 16 May 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (21) , 10999-11006
Open AccessDerivation of Particle Number Concentration from the Size Distribution: Theory and Applications
The particle number concentration (PNC) in a suspension is a key measurand in nanotechnology. A common approach for deriving PNC is to divide the total mass concentration by the per-particle mass, calculated as density times volume. The volume is most frequently derived from the arithmetic mean diameter (AMD) of the size distribution. The harmonic mean volume (HMV) has also been used. Given a known size distribution, we show that the correct PNC is obtained by using the arithmetic mean volume (AMV). The AMD-based volume results in an overestimate in PNC that increases superlinearly with increasing coefficient of variation (CV), reaching 12% at CV = 0.2 for a normal distribution. HMV would yield a much greater overestimate, exceeding 50%. The error in the AMD-derived PNC shows only weak skew dependence, suggesting a simple approximate correction as a function of CV in the common situation where AMD and CV are known but the overall size distribution is unknown. Using published data sets of gold nanoparticles, we demonstrate an overall consistency of ±1.1% in comparing the PNC directly determined by single-particle inductively coupled plasma-mass spectrometry (spICP-MS) and the PNCs derived from AMV using size distributions independently measured by high-resolution scanning electron microscopy and spICP-MS. We further compare AMV and AMD-derived PNCs for well-characterized polystyrene nanoparticle standards, illustrating sensitivity to distributional characteristics along with common errors to avoid. Nanoparticles in environmental samples, food additives, and nanomedicines often have CVs greater than 0.3, for which uncorrected AMD-derived PNC errors can exceed 35%.
- 12 February 2024
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 58 (3) , 323-333
Measurement of 100 nm monodisperse particles by four Accurate methods: Traceability and uncertainty
- 12 February 2024
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 58 (3) , 323-333
Measurement of 100 nm monodisperse particles by four Accurate methods: Traceability and uncertainty
- Top Cited PapersOpen Access
- 21 May 2021
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 23 (5) , 1-11
Dynamic light scattering distributions by any means
Dynamic light scattering (DLS) is an essential technique for nanoparticle size analysis and has been employed extensively for decades, but despite its long history and popularity, the choice of weighting and mean of the size distribution often appears to be picked ad hoc to bring the results into agreement with other methods and expectations by any means necessary. Here, we critically discuss the application of DLS for nanoparticle characterization and provide much-needed clarification for ambiguities in the mean-value practice of commercial DLS software and documentary standards. We address the misleading way DLS size distributions are often presented, that is, as a logarithmically scaled histogram of measured relative quantities. Central values obtained incautiously from this representation often lead to significant interpretation errors. Through the measurement of monomodal nanoparticle samples having an extensive range of sizes (5 to 250 nm) and polydispersity, we similarly demonstrate that the default outputs of a frequently used DLS inversion method are ill chosen, as they are regularizer-dependent and significantly deviate from the cumulant z-average size. The resulting discrepancies are typically larger than 15% depending on the polydispersity index of the samples. We explicitly identify and validate the harmonic mean as the central value of the intensity-weighted DLS size distribution that expresses the inversion results consistently with the cumulant results. We also investigate the extent to which the DLS polydispersity descriptors are representative of the distributional quality and find them to be unreliable and misleading, both for monodisperse reference materials and broad-distribution biomedical nanoparticles. These results overall are intended to bring essential improvements and to stimulate reexamination of the metrological capabilities and role of DLS in nanoparticle characterization.
- 21 May 2021
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 23 (5) , 1-11
Top Cited PapersOpen AccessDynamic light scattering distributions by any means
Dynamic light scattering (DLS) is an essential technique for nanoparticle size analysis and has been employed extensively for decades, but despite its long history and popularity, the choice of weighting and mean of the size distribution often appears to be picked ad hoc to bring the results into agreement with other methods and expectations by any means necessary. Here, we critically discuss the application of DLS for nanoparticle characterization and provide much-needed clarification for ambiguities in the mean-value practice of commercial DLS software and documentary standards. We address the misleading way DLS size distributions are often presented, that is, as a logarithmically scaled histogram of measured relative quantities. Central values obtained incautiously from this representation often lead to significant interpretation errors. Through the measurement of monomodal nanoparticle samples having an extensive range of sizes (5 to 250 nm) and polydispersity, we similarly demonstrate that the default outputs of a frequently used DLS inversion method are ill chosen, as they are regularizer-dependent and significantly deviate from the cumulant z-average size. The resulting discrepancies are typically larger than 15% depending on the polydispersity index of the samples. We explicitly identify and validate the harmonic mean as the central value of the intensity-weighted DLS size distribution that expresses the inversion results consistently with the cumulant results. We also investigate the extent to which the DLS polydispersity descriptors are representative of the distributional quality and find them to be unreliable and misleading, both for monodisperse reference materials and broad-distribution biomedical nanoparticles. These results overall are intended to bring essential improvements and to stimulate reexamination of the metrological capabilities and role of DLS in nanoparticle characterization.
- 25 February 2020
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 38 (2) , 023211
Tip-induced deformation of polystyrene latex reference nanoparticles in atomic force microscopy
The measurement approach typically prescribed for sizing polystyrene latex (PSL) reference nanoparticles by atomic force microscopy (AFM) is based on a single value of the height obtained from a three-dimensional image of the particle. A major challenge is that PSLs reportedly deform during sample preparation as well as imaging. While the particle-substrate deformation is controlled by adhesive contact forces, the tip-induced deformation may vary to a large degree depending on the operational conditions and the geometrical constraints imposed by the instrument. In this paper, the authors are mainly concerned with the effect of cantilever tilt, tip shape, and setpoint voltage on tip-induced deformation of PSL reference nanoparticles. Tips are characterized by scanning electron microscopy and using a multilayer Si/SiO2 tip characterizer. The authors find that the plastic flow of materials, induced by the asymmetric imaging geometry, shifts the position of the maximum particle height away from the center. This shape-change often leads to an initial height increase for PSLs that are smaller than 40 nm. Since AFM height analysis algorithms often equate apparent particle height with the highest measured point of the particle, these results have implications from the perspective of AFM-based nanoparticle metrology.
- 25 February 2020
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 38 (2) , 023211
Tip-induced deformation of polystyrene latex reference nanoparticles in atomic force microscopy
The measurement approach typically prescribed for sizing polystyrene latex (PSL) reference nanoparticles by atomic force microscopy (AFM) is based on a single value of the height obtained from a three-dimensional image of the particle. A major challenge is that PSLs reportedly deform during sample preparation as well as imaging. While the particle-substrate deformation is controlled by adhesive contact forces, the tip-induced deformation may vary to a large degree depending on the operational conditions and the geometrical constraints imposed by the instrument. In this paper, the authors are mainly concerned with the effect of cantilever tilt, tip shape, and setpoint voltage on tip-induced deformation of PSL reference nanoparticles. Tips are characterized by scanning electron microscopy and using a multilayer Si/SiO2 tip characterizer. The authors find that the plastic flow of materials, induced by the asymmetric imaging geometry, shifts the position of the maximum particle height away from the center. This shape-change often leads to an initial height increase for PSLs that are smaller than 40 nm. Since AFM height analysis algorithms often equate apparent particle height with the highest measured point of the particle, these results have implications from the perspective of AFM-based nanoparticle metrology.